Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA

Cliente:
Revisión:
A Hoja 1 De 40

MEMORIA DE CÁLCULO

REFORZAMIENTO HOTEL MONSERRAT SPA


Cra 3 N° 20-35

BOGOTÁ D.C. - CUNDINAMARCA

A 20-12-2016 EMISIÓN PARA REVISIÓN


W.PIRACOCA D.NAVAS J. CALA J. CALA
REVISIÓN FECHA DE REVISIÓN DESCRIPCIÓN DE LA REVISIÓN PREPARÓ CHEQUEÓ APROBÓ AUTORIZÓ
Revision Revision Date Revision Description Prepared by Checked by Approved by Authorized by

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 2 De 40

1 ALCANCE ........................................................................................................................... 3
2 DESCRIPCIÓN DEL PROYECTO ...................................................................................... 3
3 DOCUMENTOS DE REFERENCIA .................................................................................... 3
4 ESTUDIOS DE REFERENCIA ............................................................................................ 4
5 UNIDADES DE MEDIDA ..................................................................................................... 4
7 EVALUACIÓN DE CARGAS ............................................................................................... 6
8 COMBINACIONES DE CARGA ........................................................................................ 14
9 MODELO MATEMÁTICO .................................................................................................. 14
10 ANÁLISIS SÍSMICO....................................................................................................... 15
11 DEFLEXIONES MÁXIMAS ............................................................................................ 22
12 DERIVAS DE PISO........................................................................................................ 24
13 RESUMEN DE PARÁMERTOS SÍSMICOS DE DISEÑO .............................................. 26
14 REVISIÓN DE FLEXIÓN DE ELEMENTOS horizontales ............................................... 28
15 REVISIÓN A CORTANTE DE VIGAS ........................................................................... 30
16 DISEÑO DE COLUMNAS .............................................................................................. 33
17 LOCALIZACION DE ELEMENTOS ................................................................................ 35
18 EVALUACIÓN DEL ESTADO ACTUAL DE LA EDIFICACIÓN ...................................... 38
19 RECOMENDACIONES Y MODIFICACIONES A LA ESTRUCTURA ............................. 39
20 ANEXOS ........................................................................................................................ 40

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 3 De 40

1 ALCANCE

El alcance de este documento es realizar el reforzamiento estructural del proyecto HOTEL MONSERRAT SPA,
ubicado en la Carrera 3 N° 20-35, Barrio Las Aguas, en la ciudad de Bogotá D.C.- Cundinamarca según NSR-10
A.2 se encuentra clasificada como zona de amenaza sísmica intermedia.
La edificación es una estructura 6 pisos, altillo y cubierta, diseñada y analizada realizada en sistema de pórticos de
concreto reforzado del nivel de sotano hasta quinto piso y acero en los pisos sexto y septimo, con capacidad
moderada de disipación de energía (DMO), los entrepisos son losas aligeradas nervadas en una dirección y para
las cubiertas se utiliza teja de fibrocemento dispuestas sobre estructura metálica. El sistema de cimentación consta
de zapatas y vigas de amarre de concreto reforzado.

2 DESCRIPCIÓN DEL PROYECTO

Nombre: REFORZAMIENTO MONSERRAT HOTEL SPA

Propietario:

Ciudad BOGOTÁ D.C.

Destinación: COMERCIO

Área de construcción aproximada 240 m2

Número de pisos: 6 PISOS, ALTILLO Y CUBIERTA

Altura: 23.40 m

Cubierta:

Tipo cimentación: Zapatas y vigas de amarre

3 DOCUMENTOS DE REFERENCIA

REGULACIONES LOCALES

- Reglamento Colombiano de Diseño y Construcción Sismo Resistente, NSR-10


- Normas Técnicas Colombianas, NTC ( 121,321,174,3459,2289,1925,2310,161,1920)

CÓDIGOS INTERNACIONALES DE DISEÑO

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 4 De 40

- ASCE 7-10 Minimum Design Loads for Buildings and Other Structures
- ASCE 7-10 Guide to the Seismic Load Provisions – American Society of Civil Engineers
- ASCE 7-10 Guide to the Wind Load Provisions – American Society of Civil Engineers
- IBC-12 International Building Code – International Code Council
- ACI 318-08 Building Code Requirements for Structural Concrete - American Concrete Institute
- ACI 224.1 Causes, Evaluation, and Repair of Cracks in Concrete Structures – American Concrete
Institute
- AISC 325-10 Steel Construction Manual, 13th Edition (5th Printing)
- AISC 327-05 AISC Seismic Design Manual

4 ESTUDIOS DE REFERENCIA

Se cuenta con los planos arquitectónicos y estructurales copia de los originales radicados en 1966 en la División
de Control de Obras Publicas Distritales de Bogotá, suministrados por GCM Ingenieria LTDA. Los parámetros
sísmicos se obtuvieron de la NSR-10 y el Decreto 523 de 2010 de microzonificación sísmica de Bogotá, con los
siguientes datos:

PARÁMETROS SÍSMICOS

Aa coeficiente que representa la aceleración horizontal pico efectiva 0.15

Av coeficiente que representa la velocidad horizontal pico efectiva 0.20

Nivel de amenaza sísmica INTERMEDIA

Perfil de suelo PIEDEMONTE B

PARÁMETROS GEOTÉCNICOS

Tipo de cimentación Zapatas y vigas de amarre

Capacidad portante

5 UNIDADES DE MEDIDA

Los diseños y cálculos serán desarrollados usando las siguientes Unidades:

- Longitud: Metro m
Milímetro mm
- Área: Metro cuadrado m2
Milímetro cuadrado mm2
- Volumen: Metro cúbico m3

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 5 De 40

Milímetro cúbico mm3


- Fuerza: Kilo newton kN
Kilogramo kg
- Masa: Kilogramo kg
- Presión: Kilo pascal kPa=KN/m2
Mega pascal Mpa=N/mm2
- Peso específico: Kilo newton/ metro cúbico kN/m3

6 CARACTERÍSTICAS DE LOS MATERIALES

Las propiedades de los materiales usados para el diseño de la estructura se resumen a continuación:

CONCRETO

Vigas, losas, columnas 21 N/ mm2

Muros 28 N/ mm2

ACERO DE REFUERZO

- Acero corrugado, Grado 60, con límite de Fluencia fy = 420 N/mm2 para todos los diámetros, NTC 2289
(ASTM A-706).
- Malla acero corrugado para todos los diámetros, con límite de Fluencia fy=485 N/mm2

ACERO PARA PERFILES TUBULARES

- Acero ASTM A 53 Gr B

ACERO PARA PERFILES LAMINADOS EN CALIENTE

- Acero ASTM A 572 Gr 50

ACERO PARA TENSORES

- Acero ASTM A 36

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 6 De 40

7 EVALUACIÓN DE CARGAS

Los tipos de cargas que serán consideradas en el diseño se describen a continuación

- Carga Muerta (D)

- Cargas por fluidos (F) (NO APLICA)

- Presión de Tierras (H) (NO APLICA)

- Carga Viva (L)

- Carga Viva de cubierta (Lr)

- Carga por Granizo (G)

- Carga de Viento (W)

- Carga de Sismo (E)

7. 1 CARGA MUERTA (D)

Corresponde a las solicitaciones transmitidas por el peso propio de la estructura, y por el peso de todos los
materiales permanentemente fijados a ésta o soportados por la misma. El peso propio de los muros y losas fue
calculado y distribuido manualmente a partir de la geometría y propiedades asignadas.
Cubierta: 0.3 KN/m2

7. 1.1 AVALÚO DE CARGAS NO ESTRUCTURALES

Teniendo en cuenta la disposición de los elementos no estructurales, muros ventanas, acabados de piso, paredes
y demás se realiza el siguiente avaluó de cargas por piso:
Para todos los pisos la carga de acabados y revestimientos es de 1.6 KN/m2

Carga muros Total


(KN/m2) Carga(KN/m2)

Primer Piso 1.92 3.52

Segundo Piso 1.92 3.52

Tercer Piso 2.15 3.75

Cuarto Piso 2.62 4.22

Quinto Piso 5.0 Losa entrepiso 6.63


(KN/m2)

Sexto Piso 2.66 2.0 6.26

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 7 De 40

Septimo Piso 2.18 2.0 5.78

7.2 CARGA VIVA

Las cargas vivas utilizadas corresponden a solicitaciones de uso reunión, residencial y oficinas por tanto se utilizan
de acuerdo al tipo de área a utilizar:
Habitaciones: 1.8 KN/m2
Balcones: 5.0 KN/m2
Corredores: 5.0 KN/m2
Baños: 2.0 KN/m2
Oficinas: 2.0 KN/m2
Restaurante: 5.0 KN/m2
Escaleras: 3.0 KN/m2
Gimnasio: 5.0 KN/m2

7.3 CARGA VIVA DE CUBIERTA (LR)

Corresponde a las solicitaciones transmitidas por la ocupación y uso de la estructura de cubierta de pendiente
menor de 15°.
 Carga viva de cubierta: 0.50 KN/m2 Según Tabla B.4.2.1-25

7.4 CARGAS DE GRANIZO

La ciudad de Bogotá se encuentra localizado a una altura superior a los 2000 msnm por tanto se debe tener en
cuenta cargas de granizo, con la inclinación de la cubierta se establece un valor de carga de:
 Carga de granizo: 1.00 KN/m2

7.5 CARGA DE SISMO (E)

Para este apartado se usa el espectro de diseño elástico, encontrado en NSR-10 A.2, y remplazando con los
parámetros sísmicos definidos por el estudio de suelos se obtiene:

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 8 De 40

En el NSR 10 en la Tabla No. A.3-1 (Sistema de pórticos de concreto y de acero resistentes a momentos) con
capacidad moderada moderada de disipación de energía (DMO), se establecen los valores del coeficiente de
disipación de energía para los diferentes sistemas de resistencia sísmica, y zonas de amenaza sísmica. La
estructura se encuentra ubicada en Zona de amenaza sismica Intermedia y debido al detallamiento que se le va a
dar a los elementos se usará un coeficiente de disipación de energía para una estructura de este tipo es Ro=5.0.

7.6 CARGAS DE VIENTO

Se tienen cuenta las cargas de viento para una región 3, se realiza el método simplificado para hacer el análisis de
viento. El módulo de diseño es aquel con mayores posibilidades de exposición a las cargas de viento
Se utiliza el método simplificado para el sistema principal de resistencia para fuerzas de viento:

I DEFINICIONES

Altura media de cubierta, h — El promedio de la altura hasta la cornisa y la


altura hasta el punto más elevado de la cubierta. Para cubiertas con
ángulos de inclinación menores o iguales a 10o, la altura media de cubierta
será la altura de la cornisa.
Bcorto= 9.75 m
Llargo= 23.35 m
Mporcentaje= 0.15
hcornisa= 22.80 m
hcumbrera= 23.38 m
hmedia= 22.80 m

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 9 De 40

Edificio de diafragma simple — Un edificio en el cual las cargas de viento a


barlovento y sotavento se trasmiten a través de los diafragmas de piso y CUMPLE
cubierta hacia un mismo SPRFV, es decir no tiene separaciones

Edificio bajo — Edificio cerrado o parcialmente cerrado que cumpla con


las siguientes condiciones:
(a) Altura media de la cubierta (h) menor o igual a 18 m (60 ft). NO CUMPLE

(b) Altura media de la cubierta (h) no excede la menor dimensión NO CUMPLE


horizontal del edificio.

Edificio cerrado — Un edificio que no cumpla los requerimientos de CUMPLE


edificios abiertos o parcialmente cerrados.

Estructura o edificio de forma regular — Un edificio u otra estructura que CUMPLE


no tenga geometría irregular en su forma espacial.

Edificio u otra estructura flexible — Edificios u otras estructuras esbeltas


con frecuencia natural fundamental menor a 1 Hz.

Suponiendo que el sistema esta arriostrado o restringido suficientemente


para garantizar una frecuencia inferior a 1 Hz

fa= 6.25 Hz
EDIFICIO RIGIDO

II PROCEDIMIENTO DE DISEÑO

a) CALCULO DE LA VELOCIDAD DEL VIENTO (NSR-10 B.6.5.4)

B.2.4
28.00m/s
V
B.2.3
22.00m/s

NSR-10 Figura B.6.4-1

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 10 De 40

b) DETERMINACIÓN DEL FACTOR DE IMPORTANCIA (NSR-10 B.6.5.5)

Regiones no propensas a huracanes y Regiones con


CATEGOR
regiones con posibilidad de huracanes de posibilidades de
IA
V= 40 - 45 m/s huracanes y V>45
I 0.87 0.77
II 1 1.00
III 1.15 1.15
IV 1.15 1.15
NSR-10 Tabla B.6.5-1

CATEGORIA I

A.2.5.1.4 — Grupo I — Estructuras de ocupación normal — Todas la


edificaciones cubiertas por el alcance de este Reglamento, pero que no se
han incluido en los Grupos II, III y IV.

FACTOR I = 0.87

c) IDENTIFICACIÓN DE LA CATEGORIA DE EXPOSICIÓN (NSR-10 B.6.5.6)

RUGOSIDAD DEL TERRENO B.6.5.6.2 B


Rugosidad de Terreno B — Áreas urbanas y suburbanas, áreas boscosas
u otros terrenos con numerosas obstrucciones del tamaño, iguales o
mayores al de una vivienda unifamiliar y con poca separación entre
ellas.

CATEGORIA DE EXPOSICIÓN B.6.5.6.3 B


Exposición B — La categoría de exposición B aplica cuando la rugosidad
del terreno, como se define en Rugosidad de Terreno B, prevalece por
una distancia de al menos 800 m o 20 veces la altura del edificio, la que
sea mayor, en la dirección al viento.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 11 De 40

d) DEFINICIÓN DEL COEFICIENTE DE AJUSTE POR ALTURA Y EXPOSICIÓN λ


NSR-10 FIG. B.6.4-2.

Altura media Exposición


del edifcio (m) B C D
4.5 1.00 1.21 1.47
6 1.00 1.29 1.55
7.5 1.00 1.35 1.61
9 1.00 1.40 1.66
10.5 1.05 1.45 1.70
12 1.09 1.49 1.74
13.5 1.12 1.53 1.78
15 1.16 1.56 1.81
16.5 1.19 1.59 1.88
18 1.22 1.62 1.87

λ= 1.22

e) EFECTOS TOPOGRÁFICOS NSR-10 B.6.5.7

Se deben incluir en el diseño los efectos de aumento de


velocidad del viento sobre colinas aisladas, o escarpes, que
constituyan cambios abruptos en la topografía general. Los
edificios, las condiciones del sitio y la localización deben

(a) Que la colina, o escarpe esté aislada y sin obstrucciones en


barlovento, por otros accidentes topográficos de altura cercana
a 100 veces su altura (100H) o 3 km, la que sea menor. La
distancia se debe medir horizontalmente del punto desde el
cual la altura H de la loma, colina o escarpe se mide.
(b) Que la colina, o escarpe sobresalga por encima del terreno
viento arriba por un factor de 2 o más, dentro de un radio de 3
km.
(c) Que la estructura esté localizada en la mitad superior de la
colina o cerca de la cresta del escarpe, como se muestra en la
fig. B.6.5-1.
(d) Que H/Lh ≥ 0.2 .

Como el edificio en estudio no cumple todas las condiciones

Kzt= 1.00

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 12 De 40

f) PRESION DE DISEÑO P S10 PARA ESTADOS LÍMITES DE SERVICIO

Velocidad Básica de Angulo de


Viento m/s Inclinación de la
22.00m/s 8.531

Caso de Presiones Horizontales Presiones Verticales


Carga A B C D E F G H
1 0.204 -0.093 0.134 -0.053 -0.230 -0.137 -0.160 -0.107
2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

Caso de Aleros
Carga EOH GOH
1 -0.320 -0.250
2 0.000 0.000

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 13 De 40

g) PRESION DE VIENTO DE DISEÑO SIMPLIFICADO P S kN/m 2 PARA EL


ESTADO LÍMITE DE SERVICIO

Caso de Presiones Horizontales Presiones Verticales


Carga A B C D E F G H
1 0.217 -0.099 0.142 -0.056 -0.244 -0.145 -0.170 -0.114
2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

Caso de Aleros
Carga EOH GOH
1 -0.340 -0.265
2 0.000 0.000

h) PRESION DE VIENTO DE DISEÑO SIMPLIFICADO P S kN/m 2 PARA EL


ESTADO LÍMITE DE SERVICIO

Caso de Presiones Horizontales Presiones Verticales


Carga A B C D E F G H
1 0.271 -0.123 0.178 -0.070 -0.305 -0.182 -0.212 -0.142
2 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

Caso de Aleros
Carga EOH GOH
1 -0.425 -0.332
2 0.000 0.000

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 14 De 40

8 COMBINACIONES DE CARGA

COMBINACIONES DE CARGA PARA LA VERIFICACIÓN DEL ESTADO LIMITE DE SERVICIO (MÉTODO DE


ESFUERZOS DE TRABAJO)

Las siguientes combinaciones serán utilizadas para el análisis de estabilidad de estructuras y fundaciones, y la
evaluación de la presión de suelo bajo fundaciones.
D B.2.3-1
D+L B.2.3-2
D+Lr B.2.3-3
D+0.75L+0.75Lr ó G B.2.3-4
D±0.7E B.2.3-6
D±0.75L+0.75Lr ó G B.2.3-7
D+0.75(0.7E)+0.75L+0.75Lr ó G B.2.3-8
0.6D B.2.3-9
0.6D±0.7E B.2.3-10

NOTAS:
- Fuerza sísmica reducida E = Fs / R = Fs/(Ro*∅a*∅p*∅r)

- Para la obtención de las derivas con estas combinaciones (ASD) debe emplearse la fuerza sísmica Fs sin haber sido dividida por R y
con un coeficiente de 1.0 en vez de 0.7 (i.e. ΔDERIVAS-SISMO = ΔASD*R*1.428)

COMBINACIONES DE CARGA PARA ESTADO LIMITE DE RESISTENCIA (LRFD)

Las estructuras de concreto o mampostería estructural, sus componentes y su cimentación deben diseñarse de tal
manera que sus resistencias de diseño excedan los efectos de las cargas mayoradas de acuerdo con las siguientes
combinaciones de carga por el método Estado límite de Resistencia, para:
1.4D B.2.4-1
1.2D+1.6L+0.5Lr B.2.4-2
1.2D+1.6(Lr o G o Le)+(1.0L o 0.5W) B.2.4-3
1.2D+1.0W+1.0L+0.5(Lr o G o Le) B.2.4-4
1.2D+1.0E+1.0L B.2.4-5
0.9D+1.0W B.2.4-6
0.9D+1.0E B.2.4-7

NOTA:
Fuerza sísmica reducida E = Fs / R = Fs/(Ro*∅a*∅p*∅r)

9 MODELO MATEMÁTICO

Con el análisis de las cargas actuantes, la definición de los materiales a emplear, la geometría del edificio, se
procede a su modelación matemática mediante el uso del software SAP2000 programa de análisis que mediante
métodos matriciales y aplicando análisis dinámico de espectro de respuesta, calcula los centros de masas y de
rigidez de la estructura tomando en cuenta una excentricidad mínima del 5%.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 15 De 40

Modelo matemático

10 ANÁLISIS SÍSMICO

Con las dimensiones de los elementos estructurales definidos, se procede a realizar una modelación matemática
usando las dimensiones ya citadas, así como las cargas definidas, y las características sísmicas del sitio.
Obteniendo los siguientes resultados:

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 16 De 40

INDICE DE PARTICIPACION DE MASA


Modo Periodo UX UY Sum UX Sum UY RX RY Sum RX Sum RY
20 0.210866 0.0000256 0.00026 0.86596 0.79083 0.00229 0.07053 0.43233 0.40541
21 0.207667 0.00454 0.00003224 0.87049 0.79087 0.00026 0.00412 0.4326 0.40953
22 0.204034 0.01121 0.00096 0.88171 0.79183 0.00034 0.00084 0.43294 0.41037
23 0.198845 0.0007 0.0026 0.88241 0.79443 0.00173 0.01808 0.43467 0.42845
24 0.194271 0.00001181 0.05185 0.88242 0.84628 0.04268 0.00166 0.47735 0.43011
25 0.192378 0.00026 0.00165 0.88268 0.84793 0.00125 0.00014 0.4786 0.43025
26 0.187518 0.00301 0.0005 0.88569 0.84843 0.00539 0.00001659 0.48399 0.43026
27 0.180423 0.00015 0.00004139 0.88584 0.84847 0.01139 0.00072 0.49538 0.43099
28 0.17891 0.00162 0.00039 0.88746 0.84886 0.00034 0.00407 0.49572 0.43506
29 0.176946 0.00056 0.00057 0.88802 0.84943 0.00093 0.00012 0.49665 0.43518
30 0.172407 0.000002335 0.00003528 0.88802 0.84947 1.165E-07 0.00092 0.49665 0.4361
31 0.16816 0.00054 0.00117 0.88857 0.85064 0.00028 0.02942 0.49693 0.46552
32 0.167891 0.00104 0.00076 0.8896 0.8514 0.0049 0.01832 0.50183 0.48384
33 0.166061 0.00031 0.00617 0.88991 0.85757 0.03581 0.00009962 0.53764 0.48394
34 0.164297 0.000002703 0.0006 0.88991 0.85818 0.00116 0.01085 0.5388 0.49479
35 0.163679 8.985E-09 0.0007 0.88991 0.85888 0.00238 0.00846 0.54118 0.50325
36 0.161891 0.000001735 0.000004203 0.88992 0.85888 0.00223 0.00689 0.54341 0.51013
37 0.158922 0.000007817 0.00095 0.88992 0.85983 0.00047 0.00323 0.54388 0.51337
38 0.156197 0.00023 0.00008053 0.89015 0.85991 0.00244 0.00014 0.54632 0.51351
39 0.15584 0.0008 0.00037 0.89095 0.86028 0.00509 0.00283 0.55142 0.51634
40 0.154175 0.00014 0.00032 0.89109 0.8606 0.00621 0.00104 0.55763 0.51738

Donde se verifica que la participación modal es aproximadamente 90% como determina NSR 10 A.5.4.2.

A Si mismo se evalúa el periodo límite del edificio como si se tuviera en cuenta la contribución de parte de los
elementos no estructurales de la siguiente manera:

En este caso dada la condición de reforzamiento, no se llevara hasta el 100% del cumplimiento esta estructura.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 17 De 40

Pórticos resistentes a momentos de concreto reforzado que


resisten la totalidad de las fuerzas sísmicas y que no están
limitados o adheridos a componentes más rígidos.

h 22.80 m Cu 1.054 Ta 0.78 s


Ct 0.047 α 0.9 CuTa 0.83 s
T 0.794 s Sa 0.394

 AJUSTE DEL ESPECTRO DE DISEÑO

El valor del cortante dinámico en el modelo es mayor al analizado, por lo que se deben cumplir los requisitos del
título A.5.4.5 de la NSR10, para el ajuste del cortante dinámico en la Base en relación al cortante basal de la fuerza
horizontal equivalente.

Ecuación. Ajuste de los resultados del cortante dinámico en la base.

Donde Vtj es el cortante Dinámico en cualquiera de las dos direcciones principales, y Vs el cortante Basal por el
método de FHE.

El peso de la estructura se calcula a continuación y se compara con el obtenido a través del programa e calculo

 IRREGULARIDAD TORSIONAL Y EVALUACIÓN DE DERIVAS

Esta se evalúa comparando los desplazamientos en cada esquina de la edificación, siguiendo los requerimientos
de NSR 10 A.3.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 18 De 40

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 19 De 40

1
3 4

2
Di < 1.2 ((D1+D2)/2)
Di < 1.4 ((D1+D2)/2)

1 2
Desplazamientos en x (cm)
Piso N1 dx 1 N2 dx 2 N3 dx 3 N4 dx 4
N+22.80 1462 4.82 1470 4.821 1461 4.047 1459 4.052
N+20.15 1380 4.55 1401 4.549 1377 3.588 1398 3.590
N+17.00 1285 3.64 1298 3.780 1292 2.446 1295 2.473
N+13.70 1060 2.79 1059 2.929 1040 1.859 1039 1.900
N+11.1 144 2.12 165 2.219 149 1.414 163 1.443
N+8.65 115 1.51 136 1.587 127 1.046 134 1.030
N+5.90 85 0.89 96 0.945 68 0.623 94 0.615
N+2.75 36 0.32 50 0.345 18 0.236 42 0.218
N+0.0 36 0.32 50 0.345 18 0.236 42 0.218
N-1.0 35 0.00 49 0.000 17 0.000 45 0.000

Piso Dx1 Dx3 1.2∙((Δx1+Δx3 ))/2 1.4∙((Δx1+Δx3 ))/2 Dx2 Dx4 1.2∙((Δx2+Δx4 ))/2 1.4∙((Δx2+Δx4 ))/2
N+22.80 0.277 0.459 0.44184 0.51548 0.272 0.462 0.44016 0.51352 REGULAR
N+20.15 0.909 1.142 1.23066 1.43577 0.769 1.117 1.1316 1.3202 REGULAR
N+17.00 0.849 0.588 0.86196 1.00562 0.851 0.574 0.85452 0.99694 REGULAR
N+13.70 0.669 0.445 0.66816 0.77952 0.710 0.457 0.70002 0.81669 IRREGULAR
N+11.1 0.609 0.368 0.58608 0.68376 0.632 0.413 0.62694 0.73143 IRREGULAR
N+8.65 0.622 0.423 0.62736 0.73192 0.643 0.415 0.6345 0.74025 IRREGULAR
N+5.90 0.569 0.387 0.57354 0.66913 0.599 0.397 0.59778 0.69741 IRREGULAR
N+2.75 0.000 0.000 0 0 0.000 0.000 0 0 REGULAR
N+0.0 0.319 0.236 0.33288 0.38836 0.345 0.218 0.3381 0.39445 IRREGULAR
N-1.0 -0.319 -0.236 -0.33288 -0.38836 -0.345 -0.218 -0.3381 -0.39445 IRR EXTREMA
Desplazamientos en y (cm)
Piso N dy1 N dy 2 N dy 3 N dy 4
N+22.80 1462 3.125 1470 5.074 1461 6.494 1459 5.079
N+20.15 1380 2.752 1401 11.657 1377 6.315 1398 11.819
N+17.00 1285 1.301 1298 11.602 1292 4.440 1295 11.738
N+13.70 1060 0.976 1059 9.354 1040 2.476 1039 9.493
N+11.1 144 0.728 165 7.586 149 0.726 163 7.692
N+8.65 115 0.507 136 6.228 127 0.507 134 6.306
N+5.90 85 0.288 96 4.765 68 0.289 94 4.819
N+2.75 36 0.097 50 2.220 18 0.101 42 0.283
N+0.0 36 0.097 50 2.220 18 0.101 42 0.283
N-1.0 35 0.000 49 0.000 17 0.000 45 0.000

Piso Dy1 Dy2 1.2∙((Δy1+Δy2 ))/2 1.4∙((Δy1+Δy2 ))/2 Dy3 Dy4 1.2∙((Δy3+Δy4 ))/2 1.4∙((Δy3+Δy4 ))/2
N+22.80 0.373 -6.584 -3.72612 -4.34714 0.179 -6.740 -3.9366 -4.5927 REGULAR
N+20.15 1.450 0.055 0.90306 1.05357 1.876 0.081 1.1739 1.36955 REGULAR
N+17.00 0.325 2.248 1.54416 1.80152 1.964 2.245 2.52576 2.94672 IRR EXTREMA
N+13.70 0.248 1.768 1.2096 1.4112 1.750 1.801 2.13036 2.48542 IRR EXTREMA
N+11.1 0.222 1.358 0.948 1.106 0.219 1.386 0.96306 1.12357 IRR EXTREMA
N+8.65 0.219 1.463 1.00896 1.17712 0.218 1.487 1.02318 1.19371 IRR EXTREMA
N+5.90 0.191 2.544 1.64118 1.91471 0.187 4.536 2.83392 3.30624 IRR EXTREMA
N+2.75 0.000 0.000 0 0 0.000 0.000 0 0 REGULAR
N+0.0 0.097 2.220 1.39026 1.62197 0.101 0.283 0.23046 0.26887 IRR EXTREMA
N-1.0 0.097 -2.220 -1.2741 -1.48645 -0.101 -0.283 -0.23046 -0.26887 IRR EXTREMA

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 20 De 40

Dx : Deriva máxima en X en cm Dy : Deriva máxima en Y en cm

Piso Cota Altura Dx Dy Dmax Dper IF


N+22.80 22.80 2.65 0.4616 0.37 0.46 2.65 0.17 CUMPLE
N+20.15 20.15 3.15 1.1417 1.88 1.88 3.15 0.60 CUMPLE
N+17.00 17.00 3.30 0.8506 2.25 2.25 3.30 0.68 CUMPLE
N+13.70 13.70 2.60 0.7100 1.80 1.80 2.60 0.69 CUMPLE
N+11.1 11.10 2.45 0.6324 1.39 1.39 2.45 0.57 CUMPLE
N+8.65 8.65 2.75 0.6425 1.49 1.49 2.75 0.54 CUMPLE
N+5.90 5.90 3.15 0.5994 4.54 4.54 3.15 1.44 NO CUMPLE
N+2.75 2.75 2.75 0.0000 0.00 0.00 2.75 0.00 CUMPLE
N+0.0 0.00 1.00 0.3451 2.22 2.22 1.00 2.22 NO CUMPLE
N-1.0 -1.00 -1.00 -0.2184 0.10 0.10 1.00 0.10 CUMPLE

Deriva para secciones fisuradas

Dx : Deriva máxima en X en cm Dy : Deriva máxima en Y en cm

Piso Cota Altura Dx Dy Dmax Dper IF


N+22.80 22.80 2.65 0.46 0.37 0.46 3.79 0.17 CUMPLE
N+20.15 20.15 3.15 1.14 1.88 1.88 4.50 0.60 CUMPLE
N+17.00 17.00 3.30 0.85 2.25 2.25 4.71 0.68 CUMPLE
N+13.70 13.70 2.60 0.71 1.80 1.80 3.71 0.69 CUMPLE
N+11.1 11.10 2.45 0.63 1.39 1.39 3.50 0.57 CUMPLE
N+8.65 8.65 2.75 0.64 1.49 1.49 3.93 0.54 CUMPLE
N+5.90 5.90 3.15 0.60 4.54 4.54 4.50 1.44 NO CUMPLE
N+2.75 2.75 2.75 0.00 0.00 0.00 3.93 0.00 CUMPLE
N+0.0 0.00 1.00 0.35 2.22 2.22 1.43 2.22 NO CUMPLE
N-1.0 -1.00 -1.00 -0.22 0.10 0.10 1.43 0.10 CUMPLE

Estructura sufre de irregularidad torsional extrema en algunos niveles, por tanto, el coeficiente de irregularidad
torsional es:
∅ tx= 0.8
∅ ty= 0.8
 IRREGULARIDAD POR RETROCESOS EN LAS ESQUINAS EN PLANTA

Se determina que existe irregularidad en planta por retrocesos en las esquinas, por tanto el coeficiente por
irregularidad en planta es:

∅px= 0.9

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 21 De 40

∅py= 0.9

IRREGULARIDAD DEL DIAFRAGMA

Como el edificio no se ve influenciado por algún tipo de irregularidad en el diafragma, el coeficiente por irregularidad
en diafragma es:
∅p= 1

IRREGULARIDAD EN ALTURA

El edificio posee irregularidades en altura, por tanto:


a b REVISIÓN DE LA
PISO
m ∅ ay=0.9;
m ∅ ax=0.9IRREGULARIDAD
Cubierta 8.4 8.4 a<1.30b
Nivel 03 8.4 8.4 a<1.30b
Nivel 02 8.4 8.4 a<1.30b
Nivel 01 8.4 8.4 a<1.30b
Base DE CONSULTORIA Y SUPERVISIÓN
ESTE DOCUMENTO ES PROPIEDAD 8.4 DE ESTRUCTURAS
8.4 SAS Y NO DEBEa<1.30b
SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN

Base 8.4 8.4 a<1.30b


Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 22 De 40

AUSENCIA DE REDUNDANCIA EN EL SISTEMA ESTRUCTURAL DE RESISTENCIA SÍSMICA

Se determina que existe redundancia en el sentido X y en el sentido Y de la estructura, por tanto:

∅ rx=1.0
∅ ry=1.0

 COEFICIENTE DE DISIPACIÓN DE ENERGÍA


Con la evaluación de los factores de reducción de la capacidad de disipación de energía determinados, se procede
a evaluar el valor global R de la estructura. En este caso como el Ro es 5.0, no se aplican los coeficientes de
reducción φa, φp, y φr, ya que el valor mínimo para R es 1.

CALCULO DE R EN LA CALCULO DE R EN LA
DIRECCIÓN X DIRECCIÓN Y
∅p= 0.9 Ro= 5.0 ∅p= 0.9 Ro= 5.0
∅a= 0.9 ∅a= 0.9
∅r= 1 Rx= 4.1 ∅r= 1 Ry= 4.1

11 DEFLEXIONES MÁXIMAS

Se han revisado las máximas deflexiones para condiciones de servicios sobre la losa para verificar que estos no
sobrepasen los límites de servicio sugeridos por el C.9. De NSR-10, haciendo un análisis elástico de segundo orden
en el que se considera la influencia de las cargas axiales, la presencia de regiones agrietadas a lo largo del elemento
y los efectos de duración de las cargas como lo indica C.10.10.4.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 23 De 40

La deflexión máxima es 3.08 mm y la máxima recomendada según la tabla C.9.5 (b) de la NSR-10 es de
18.43mm (L/480).

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 24 De 40

La deflexión máxima es 3.40 mm y la máxima recomendada según la tabla C.9.5 (b) de la NSR-10 es de
18.43mm (L/480).

12 DERIVAS DE PISO

De acuerdo a los lineamientos de las condiciones de servicio del NSR-10 se revisan los máximos desplazamientos
para la edificación y se revisa si estos cumplen con la flexibilidad límite requerido.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 25 De 40

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 26 De 40

Dx : Deriva máxima en X en cm Dy : Deriva máxima en Y en cm

Piso Cota Altura Dx Dy Dmax Dper IF


N+22.80 22.80 2.65 0.4616 0.37 0.46 2.65 0.17 CUMPLE
N+20.15 20.15 3.15 1.1417 1.88 1.88 3.15 0.60 CUMPLE
N+17.00 17.00 3.30 0.8506 2.25 2.25 3.30 0.68 CUMPLE
N+13.70 13.70 2.60 0.7100 1.80 1.80 2.60 0.69 CUMPLE
N+11.1 11.10 2.45 0.6324 1.39 1.39 2.45 0.57 CUMPLE
N+8.65 8.65 2.75 0.6425 1.49 1.49 2.75 0.54 CUMPLE
N+5.90 5.90 3.15 0.5994 4.54 4.54 3.15 1.44 NO CUMPLE
N+2.75 2.75 2.75 0.0000 0.00 0.00 2.75 0.00 CUMPLE
N+0.0 0.00 1.00 0.3451 2.22 2.22 1.00 2.22 NO CUMPLE
N-1.0 -1.00 -1.00 -0.2184 0.10 0.10 1.00 0.10 CUMPLE

13 RESUMEN DE PARÁMERTOS SÍSMICOS DE DISEÑO

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 27 De 40

Municipio Bogotá D. C.
Departamento CUNDINAMARCA
PARÁMETROS SISMICOS GENERALES

Nivel de amenaza sísmica Intermedia


Uso permitido si
Altura máxima sin límite
Perfil de suelo D
Coeficiente de importacia I I
Coeficiente que representa la aceleración horizontal pico efectiva Aa 0.15
Coeficiente que representa la velocidad horizontal pico efectiva Av 0.2
Coeficiente de amplificación que afecta la aceleración en la zona de
1.50
períodos cortos Fa
Coeficiente de amplificación que afecta la aceleración en la zona de
2.00
períodos cortos Fv

Tabla A.3-3 Sistema estructural de pórtico resistente a


Sistema de resistencia sismica 2. Pórticos resistentes a momentos con capacidad
moderada de disipación de energía (DMO)
Sistema resistencia sísmica (fuerzas horizontales)
c. Mixtos con conexiones rígidas (DMO)

Sistema resistencia para cargas verticales Pórticos de acero o mixtos resistentes o no a momentos
SENTIDO X

Coeficiente de capacidad de disipación de energia básico R 0 5


Coeficiente de sobrerressitencia Ω0 3
Deriva máxima 0.61
Deriva permitida 21.00
Coeficiente de reducción de la capacidad de disipación de energía causado Irregularidad torsional
por irregularidades en planta de la edificación ∅p 0.90
Coeficiente de reducción de la capacidad de disipación de energía causado Geométrica
por irregularidades en altura de la edificación ∅a 0.90
Coeficiente de reducción de la capacidad de disipación de energía causado No
por ausencia de redundancia en el sistema de resistencia sísmica ∅r 1.00
Coeficiente de capacidad de disipación de energia R en el sentido X 4.05

Tabla A.3-3 Sistema estructural de pórtico resistente a momentos


Sistema de resistencia sismica 2. Pórticos resistentes a momentos con capacidad
moderada de disipación de energía (DMO)
Sistema resistencia sísmica (fuerzas horizontales) c. Mixtos con conexiones rígidas (DMO)

Sistema resistencia para cargas verticales Pórticos de acero o mixtos resistentes o no a momentos
SENTIDO Y

Coeficiente de capacidad de disipación de energia básico R 0 5


Coeficiente de sobrerressitencia Ω0 3
Deriva máxima 0.31
Deriva permitida 21.00
Coeficiente de reducción de la capacidad de disipación de energía causado Irregularidad torsional
por irregularidades en planta de la edificación ∅p 0.90
Coeficiente de reducción de la capacidad de disipación de energía causado Geométrica
por irregularidades en altura de la edificación ∅a 0.90
Coeficiente de reducción de la capacidad de disipación de energía causado No
por ausencia de redundancia en el sistema de resistencia sísmica ∅r 1.00
Coeficiente de capacidad de disipación de energia R en el sentido X 4.05

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 28 De 40

14 REVISIÓN DE FLEXIÓN DE ELEMENTOS HORIZONTALES

Se han revisado las cargas para estado límite de resistencia última y determinado el acero de flexión necesario
para resistidas según C.10. De NSR-10 obteniendo los resultados que se muestran a continuación.

Acero a flexión necesario piso 1.

Acero a flexión necesario Piso 2.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 29 De 40

Acero a flexión necesario Piso 3.

Acero a flexión Piso 4

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 30 De 40

Acero a flexión Piso 5

15 REVISIÓN A CORTANTE DE VIGAS

Se han revisado que la cantidad de acero a cortante sea el necesario para resistir las solicitaciones según
C.11. Y C.21 De NSR-10 obteniendo los resultados que se muestran a continuación.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 31 De 40

Acero a cortante necesario piso 1

Acero a cortante necesario piso 2

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 32 De 40

Acero a cortante necesario piso 3

Acero a cortante necesario piso 4

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 33 De 40

Acero a cortante necesario piso 5


.

16 DISEÑO DE COLUMNAS

Se han revisado que la cantidad de acero necesaria para las columnas según C.11. Y C.3.3.9. De NSR-10 con los
resultados dados en la imagen. Rx-y=1.44, y Ωo=2.5.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 34 De 40

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 35 De 40

17 LOCALIZACION DE ELEMENTOS

Secciones.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 36 De 40

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 37 De 40

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 38 De 40

18 EVALUACIÓN DEL ESTADO ACTUAL DE LA EDIFICACIÓN

En cuanto al estado actual de la edificación prsenta buenos acabados, adicionalmente se realizaron ensayos de
esclerometria que evidenciaron que los materiales presentan un buen comportamiento. A continuación se
presentan algunas imágenes de la toma de datos de esclerometria

Figura 1. Esclerometro

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 39 De 40

Figura 2. Valores de esclerometria en muro

Figura 3. Muestra para toma de valores de esclerometria

19 RECOMENDACIONES Y MODIFICACIONES A LA ESTRUCTURA

En los primeros pisos se recomienda recalzar y aumentar las secciones de columnas de concreto hasta el quiento
piso, en el sexto y séptimo piso se recomienda esquemas de marcos metálicos.

En cuanto a la rigidización de la estructura se debe diseñar un sistema de pantallas en el nucleo de la escalera y


el ascensor.

ESTE DOCUMENTO ES PROPIEDAD DE CONSULTORIA Y SUPERVISIÓN DE ESTRUCTURAS SAS Y NO DEBE SER COPIADO, REPRODUCIDO Y/O CIRCULADO SIN SU AUTORIZACIÓN
Proyecto: REFORZAMIENTO HOTEL MONSERRAT SPA
Cliente:
Revisión:
A Hoja 40 De 40

20 ANEXOS