Figure 1.4 From Figure 5.6 - Snow load shape coefficients for cylindrical roof.
used is shown in Figure 5.6, case (i). The drifted load arrangement which should
be used is shown in Figure 5.6, case (ii), unless specified for local conditions.
where:
• s is the snow load shape coefficient due to sliding of snow from the
upper roof. For 15 , s = 0 . For 15 , s is determined from an
additional load amounting to 50% of the maximum total snow load, on
the adjacent slope of the upper roof calculated according to 5.3.3
• w is the snow load shape coefficient due to wind w = b 1 + b 2 2h h s k ,
where = 2 kN m 3 is the weight density of snow. An upper and a lower
value of w should be specified. The range for w may be fixed in the
National Annex. The recommended range is 0 8 w 4
• the drift length is determined as follows: l s = 2h . A restriction for l s may
be given in the National Annex. The recommended restriction is
5 l s 15 m .