Date 8/9/2018 Kruger Ventilation Industries Pte Ltd

Company - No. 17 Tuas Avenue 10


Attention - Singapore 639141
Project -
Reference Tel: +65 6861 1577 Fax: +65 6861 3577
Email: mktg@krugerasia.com

Fan Selection
Fan Type
Unit TDA900-12AA-12-12 / 16°
Operating Conditions Ducted
Required Volume 21,900 m³/h
Required Static Pressure 200 Pa
Air Volume 22,945 m³/h
Static Pressure 220 Pa
Velocity Pressure 30.9 Pa
Total Pressure 250 Pa
Outlet Velocity 10.02 m/s
Fan Total Efficiency 61.3 %
Fan Static Efficiency 53.8 %
Fan Speed 1450 rpm
Air Temperature 300 °C
Altitude 0m
Fan Absorbed Power 2.60 kW
Motor Selection
Recommended Motor D100L (3.00 kW)
Motor Speed 1450 rpm
Service Factor 15 %
Operating Limits
Max. Absorbed Power -
Max. Fan Speed -
Temperature (Min-Max) -

Hz 63 125 250 500 1k 2k 4k 8k Overall


Lwi(Lin) 92 93 101 94 92 89 86 83 103 dB
Lwi(A) 66 77 92 91 92 90 87 82 98 dB(A)
Lpi(A) 55 66 82 80 81 79 76 71 87 dB(A)
* Sound data is for the inlet side * Sound Pressure Level 1.5m, Room Conditions

A B C D N° Ø
900 945 1000 630 18 12