Escolar Documentos
Profissional Documentos
Cultura Documentos
Ⅱ SPECIFICATIONS
Unless otherwise stated in the Contract, the Tenderer's quality system shall be based
on the appropriate ISO 9000 series standard and shall be described in a project-
specific Quality Plan, to be submitted when Tender Document is submitted.
The Tenderer shall confirm to all clauses of this specification. The Tenderer shall, for
this purpose, take all necessary measures, making use of suitable means, devices
and qualified personnel and enabling them to ensure the permanent and effective
control of the design & fabrication.
The successful Tenderer shall report to the Employer constantly for the result of all
inspection which shall be carried out by the successful Tenderer during fabrication.
These reports shall be submitted to the Employer upon the request of the Employer at
any time.
Only supplies fully fulfilled with the requirements of this specification shall be
presented to the Employer for final acceptance.
The Tenderer shall provide office space and inspection facilities, as required by the
Employer, in shops where the material are fabricated. Free access shall be allowed to
the Employer at all the times during fabrication and testing.
The “Inspection and Test Plan” with acceptance form shall be submitted within four (4)
weeks of the Contract signing for the Employer’s approval by the Tenderer. But
preliminary “Inspection and Test plan” shall be submitted with Tender Document.
The Employer's approved drawings, schedules and associated documents, and the
selected Tenderer's documents shall be used as the basis of the aforementioned tests
and inspections. No test or inspection shall be permitted until the schedule and test
forms are approved by the Employer.
All drawings and documents used during the inspection / tests shall be "highlighted"
and copies kept for the record.
The Tenderer shall also provide documentation for recording discrepancies, errors,
faults, component failure and changes. Each document shall be dated and signed by
the Employer's representative. This document shall be attached to the
drawings/documents used for the tests. The degree or re-testing required after a
fault/error rectification or component replacement shall be at the discretion of the
Employer's representative.
Any malfunction of the supplies shall be rectified and re-tested, to the satisfaction of
the Employer's representative, at the Tenderer's expense, as part of the acceptance
test.
After fault rectification, the decision whether to continue or revert to the start of testing
shall rest entirely with the Employer's representative.
1) Inspection
6) In addition, the presentation of drawings shall be such that all component parts
of items can be located and identified for maintenance purposes.
3.2 Manuals
The Tenderer shall submit the arrangement design manual and arrangement
manual of Keel block in accordance with the requirements of the tender document
upon delivery of the Keel Wooden Block inclusive as below contents.
1) Keel block arrangement design manual for each type of Keel block.
2) Typical Keel block arrangement method with drawing for each type of repair
ship
the material proof for Keel Wooden Block and accessories to the Employer
before deciding the technical configuration.
This specification describes minimum requirements for the material design and
all material for Keel Wooden Block shall be approved by the Employer to select
the most adequate Keel block and accessories for ship repair activities.
2) Coefficient of shrinkage
The Keel Wooden Block shall be able to endure safe load of design tolerance
and safety factor shall be over 10 unless otherwise specified.
General Keel Wooden Blocks are referenced in the chart below. Tenderer shall
design, manufacture and supply according to the detail drawing enclosed this
specification. All types of Wooden block shall be supplied in dry condition
according to maker drying procedure.
1400x350x60
ODC-DC-KB-03 Wood Block “A”
“APITONG”
1600x350x200
ODC-DC-KB-05 Wood Block “C”
“APITONG”
Round bar
ODC-DC-KB-06 Nail
Ø10
Iron bar
ODC-DC-KB-07 Clamp
Ø16
- Welding condition
- Fitting condition
- Edge condition
- Deformation or any defect
- Dimensional
- Painting and Galvanizing condition
- Others
Employer will be check quantity for the Keel Wooden Block received with the
specification sheets, material summary sheets and parking lists.
Tenderer shall carry out safety strength load test to authorized society in
accordance to this specification and shall submit to the Employer all test reports
and material certificates at the time of visual inspection with Employer.
The Employer can request sampling safety strength load test of Keel Wooden
Block.