Você está na página 1de 4

Medium voltage power cable

RHZ1-OL 12/20 kV
Article number: 54186 11-09-2018

Description
1 X 400 K Al + H16

TWENPOWER - single core medium voltage cables - 12/20 kV -


RHZ1-OL

Trading information
Product group Medium voltage power cable

Series Medium voltage power cable

Type RHZ1-OL 12/20 kV

Net. Weight 2,291 kg/m

Sheath marking {Length} TKF - RHZ1-OL 12/20 kV 1 x 400 K AL + H16 - HD620-S1-5E -


{Year} {Batch}

Trade lengths
(54186 / 8713182091941)

www.tkf.eu Subject to technical modifications | No rights can be derived from this information

Spinnerstraat 15 | P.O. Box 6 | 7481 KJ Haaksbergen | Nederland | Phone: +31 (0)53 573 22 55 | E-mail: info@tkf.nl Page 1 of 4
Medium voltage power cable

RHZ1-OL 12/20 kV
Article number: 54186 11-09-2018

Construction characteristics
Standardization HD 620 S1 - Part 5E

Radial water blocking No

Longitudinal water blocking conductors No

Longitudinal water blocking screen Yes

Armouring No

Number of cores 1

Nominal cross section conductor 400 mm²

Conductor material Al

Shape of conductor Round

Conductor category Class 2c = stranded & compacted

Nominal earthscreen cross section 16 mm²

Earthscreen construction Copper round wire + copper tape counter spiral

Core insulation XLPE (VPE)

Insulation shield Semiconductive strippable Compoundwith swellable tape

Material outer sheath MDPE

Colour outer sheath Red

www.tkf.eu Subject to technical modifications | No rights can be derived from this information

Spinnerstraat 15 | P.O. Box 6 | 7481 KJ Haaksbergen | Nederland | Phone: +31 (0)53 573 22 55 | E-mail: info@tkf.nl Page 2 of 4
Medium voltage power cable

RHZ1-OL 12/20 kV
Article number: 54186 11-09-2018

Properties
Halogen free IEC 60754-1 / IEC 60754-2

Conductor diameter 24.2 mm

Insulation thickness 5.5 mm

Diameter over insulation 36.4 mm

Diameter shield wires 0.8 mm

Diameter over shield 40 mm

Outer sheath thickness 3 mm

Outer diameter approx. 46 mm

Min. bending radius during installation 0.84 m

Min. bending radius after installation 0.7 m

Tensile force with pullinghead 12000 N

Technical characteristics
Nominal voltage U0 12 kV

Nominal voltage U 20 kV

Nominal voltage Umax 24 kV

Conductor DC resistance @ 20°C 0.0778 Ohm/km

Max. conductor temperature 90 °C

E-Min fieldstrength 1.79 kV/mm

E-Max fieldstrength 2.59 kV/mm

Shield DC resistance 1.0532 Ohm/km

Mutual capacitance (Nominal) 0.39 µF/km

Operating reactance trefoil arrangement 0.1 Ohm/km

Operating reactance flat arrangement 0.173 Ohm/km

Conductor AC resistance @ max. cont. 0.1 Ohm/km


Conductor temp.

Frequency 50 Hz

Charging current per core 1.47 A/km

www.tkf.eu Subject to technical modifications | No rights can be derived from this information

Spinnerstraat 15 | P.O. Box 6 | 7481 KJ Haaksbergen | Nederland | Phone: +31 (0)53 573 22 55 | E-mail: info@tkf.nl Page 3 of 4
Medium voltage power cable

RHZ1-OL 12/20 kV
Article number: 54186 11-09-2018

Maximum current buried trefoil 460 A


arrangement

Maximum current buried flat arrangement 495 A

Maximum current in air trefoil arrangement 675 A

Maximum current in air flat arrangement 825 A

Homopolaire resistance Ro (trefoil) *) 3.261 Ohm/km

Homopolaire resistance Ro (flat) *) 3.261 Ohm/km

Homopolaire reactance Xo (trefoil) *) 0.313 Ohm/km

Homopolaire reactance Xo (flat) *) 0.56 Ohm/km

Homopolaire impedance Zo (trefoil) *) 3.276 Ohm/km

Homopolaire impedance Zo (flat) *) 3.309 Ohm/km

max. thermal short-circuit current conductor 53.2 kA


0,5 sec

max. thermal short-circuit current conductor 37.6 kA


1 sec

max. short-circuit temperature conductor 90 °C

max. thermal short-circuit current shield 0,5 3.4 kA


sec

max. thermal short-circuit current shield 1 2.4 kA


sec

max. short-circuit temperature shield 250 °C

Minimum installation temperature 0 °C

Max. operation temperature 70 °C

*) Theoretical calculated values Depends on application

www.tkf.eu Subject to technical modifications | No rights can be derived from this information

Spinnerstraat 15 | P.O. Box 6 | 7481 KJ Haaksbergen | Nederland | Phone: +31 (0)53 573 22 55 | E-mail: info@tkf.nl Page 4 of 4