Você está na página 1de 13

DF-650 Super Surgical Suction Unit (digital)

DF-650

FEATURES :

 DIGITAL VACUUM MONITOR is used to show the suction power, so users can easily read it.

 The suction tube directly connects to the suction bottle, so users can easily wash it. It’s sanitary and

safe.

 The handle attached to the suction bottle makes users easily lift and wash it.

 The foot switch adopts air pressure type, so it is anti-moisture, insulating and safe.

 360 individual caster with locking brakes features easy movement and high safety.

 The fastening rack installed at the side makes the suction tube be easily put.

Standard Accessory

 Suction tube (S) 180 cm … 1 pc

 Suction catheter … 1 pc

 Foot switch … 1 pc

 Filter (L) … 2 pcs

 Max. HP. : 250W, 1/3HP

1
 Vacuum range : 10~720mmHg

 Max. flow : 80 liters/min

 Capacity : 3000C.C.x 2 pcs

 Net weight : 19 kg

 Gross weight : 25 kg

 Machine size : L45 x W35 x H84 (cm)

 Packing size: L54 x W44 x H95 (cm)

2
Dry-mist disinfection system / mobile
Aerosept 500

Characteristics
 Disinfection procedure:
dry-mist
 Other characteristics:
Mobile

Description
» High treatment capacity:
room from 30 to 300 m3.
» Process in compliance with standard
NF T 72-281, 2014 version.
» User-friendly operator touch screen.
» Traceability of the room and user via barcode.
» Recovery of data on USB drive.

INDICATIONS

Fully-automated stand-alone atomiser for the disinfection of


previously cleaned surfaces.

TECHNICAL CHARACTERISTICS

• Tank capacity: 5L can


• Average fl ow rate: 1L/hour
• Empty weight: ≈ 32 Kg
• Dimensions: H900 x W350 x D400
• Power supply: 240/110 V – 50/60 Hz – 5 A

3
Pressure infusion cuff
Switch 2.0 HPC

Description
The pressure infusion cuff from the ERKA SWITCH 2.0 family can be used repeatedly. Its ergonomic feature makes its use easy.
The outer cover is washable. The mesh fabric is long lasting and flexible. The bulb is made up of high quality PU and all the rubber
parts are latex free in a natural way.

4
Infusion warmer
QW618

Description
The QW618 blood and infusion warmer can be used for a variety of medical applications to include infusion for patients after or
during operation, blood transfusion, infusions for emergency treatments, infusion in clinical environments, normal infusion during
cold weather and neonates and children infusion. This blood and infusion warmer also assists with heating of the fluid for flushing
and is boasts a microprocessor system that renders accurate control, temperature monitoring and malfunction alarm.

This dry warmer also displays temperature in real time and has the ability to set temperature accordingly and infusion tubing and
normal tubing can be performed at a low rate. Some other specifications of the QW618 blood and infusion warmer include AC220V
power supply, Class I electric shock protection, 1.3 kg net weight and measures 100×170×210 mm.

5
Manual bed / height-adjustable / medical / on casters
APC-80781

Characteristics
 Operation:
manual
 Features:
height-adjustable
 Other characteristics:
medical, on casters
 Number of sections:
4-section
Description
Functions

Hi- Low: by 27cm adjustable from 45cm to 72cm (±5%).


Back rise by 85° (±5%).
Foot rise by 40° (±5%).
Removable Plastic head and foot board.

Specification

Complete unit made of powder coated steel.


Sleep surface: ABS plastic material, removable for cleaning.

Option Dimension

A: 214cmL x 100cmW with side rails (±5%).


B: 207cmL x 93cmW with side rails (±5%).

Standard accessories

One-piece typed foldable side rail.


One table board.
Two sections I.V. Stand.
5" braking wheels.

6
Multi-parameter transport monitor / EtCO2 / cardiac output / IBP
PM-9000 Express

Characteristics
 Applications:
transport
 Measured parameters:
EtCO2, cardiac output, IBP, NIBP, temperature, SpO2, ECG
 Configuration:
portable
 Other characteristics:
wireless

Description
The PM-9000 Express Patient Monitor is a state-of-the-art portable monitor featuring a large TFT color display. The 12.1" TFT
color display uses a large font display and has eight waveforms. It has up to 96 hours of graphic and tabular trends for all parameters.
It benefits from 12-lead ECG analysis and SpO2 pulse-tone modulation.

The device utilizes a wireless LAN card or a fixed compact flash for memory card. The compact unit uses multi-gas with O2
dependent on agent identification. The standard configuration of a PM-9000 Express Patient Monitor includes SpO2, dual
temperatures, respiration, ECG, NIBP and lead acid battery.

7
Ceiling-mounted surgical light / LED / with control panel
LED 5 MC Smart

Characteristics
 Configuration:
ceiling-mounted
 Light source:
LED
 Other characteristics:
with control panel
 Intensity at 1 m:
160000 lx

Description
Effective.

Our powerful LED-technology helps keeping a cool head through an almost inexistent heat development in the surgeon's head area
and wound field.

On the spot.

The built-in laser pointer always indicates the middle of the light field and helps the surgeon to find the optimal position of the OT-
light to the wound field. After a short time the laser pointer turns off automatically.

Functional.

All functions can be set by the sterilisable handle. Turning the handle or the ring at the top of the handle (depending on the model)
allows the surgeon to merge the light fields, change the colour temperature, illuminate in depth and activate the laser pointer. All
functions and settings take place in the sterile area.

8
HS-5020G(Gravity)

1. Strong and Sound Structure


This sterilizer, which has a practical medium sized chamber between
large and small sized sterilizer and is very effective to load the volumed
loads, uses the saturated vapor as sterilant supplied from the built-in
steam generator or external steam supply system. The cylindrical
chamber with jacket is the most sound structurally and the door is sealed
firmly by a locking system with radial levers. It is fully automated in all
processes by means of microprocessor. If a trouble takes place, it alarms
with digital display and buzzer through the self-diagnosis function, and
then stops the cycles. The door system shall consist of a door and an
opening/closing mechanism which shall be manually operable.

2. Variable Cycle Programs and Self-Diagnosis Program


4 kinds of optimized basic cycle program for sterilizing general medical
instruments are embedded in the controls of sterilizer. Therefore operator
can select a proper cycle conveniently for sterilizing a load and change
the parameters of program easily according to the sterilizing condition.
The self-diagnosis program generates the warning signal, displays the
error code on the control panel and aborts the executing cycle for safety
automatically in case that any operating error has occurred during cycle
executing.

3. Cycle Execution Data Storing and Retrieval Function


At least 11 years of cycle execution records are automatically stored on
the Flash memory of the control unit. The user can search and check the
results of a cycle performed in the past by input the date performed or
cycle count number on the touch screen, and print out the record by the
built-in panel printer for using as an evidence data of sterilization quality.
(optional specification)

4. Safety
The door would not be opened without power supplying and cycle does

9
not start unless the door is locked. The door locking system is designed
to seal the chamber simply by the radial lever type. To open the door
safely under chamber pressure, turn the door handle counter clockwise,
then the radial levers are released and the vapor is leaked through the
gap between chamber edge and door. Strong opening/closing
mechanism and heat-blocking door plate cover would protect the
operator from a possible accident during sterilizing. In case the chamber
pressure exceeds in the set value, the safety valve exhausts the vapor
from the chamber and then decreases the chamber pressure.

5. Built-in Printer
The built-in panel printer prints out the cycle performance record for
securing the traceability afterwards.

Model HS-5020G

Overall Dimension W760 x D1,334 x H1,695 ㎜

Chamber ø500 x D1,000 ㎜, Vol: 196ℓ, Material: STS 316L

Loading Shelf W480 x D975 x H22 ㎜ Q'ty: 1EA, W270 x D975 x H22 ㎜ Q'ty: 1 EA

Operating Temperature 121.0℃ ~ 135.0℃

Air Removal Gravity

Controls Microprocessor

Printer Direct Thermal Printing, Printing paper roll: W58 x Ø40 mm

AC 220V, 1ph, 50/60Hz, 45A

AC 220V, 3ph, 3wire, 50/60Hz, 25A


Power Source
AC 380V, 3ph, 4wire, 50/60Hz, 15A

External Steam Only : AC230V, 50/60Hz, 5A

Builtin Steam Generator; 6kW Heater

Steam Source External Steam System; Saturated Steam of 97% Dryness

3.5~5.0 Bar Pressure, Flow Rate: max. 20㎏/h

Net Weight 350 ㎏

* Altitudes up to 2,000 meters.


* Temperature range of +5℃ to +40℃.

Environment Conditions * Maximum relative humidity of 80%.


* Main supply voltage fluctuation of ±10% of nominal.
* Installation Category (Overvoltage Category) Ⅱ, Pollution Degree 2.

10
High Frequency Bipolar Electrosurgical Unit
Electrocautery Machine Guangzhou

Model: MCS-ESU-2000I

Highest output:300W

Six working modes:

Monopolar: pure cut,blend1, blend2,contact coagulation, forced


coagulation

Bipolar: bipolar coagulation


1. The electrosurgical generator is used to control bleeding and surgical
cutting in all general and open surgical procedures
2. Touch control panel, three-way power output, with different audible and
visual indication during the process of outputting.
3. Patient return electrode monitoring system and Power Peak System that
provides surgeons with improved performance at Lower power settings,
minimizing the risk of tissue damage.
4. Applicable for Prostate Vaporizing Surgical Operation(TUR), perfectly
used under water.
The electrosurgical generator can be cooperated with argon plasma
coagulator, endoscope and laparoscope.
5. Pencil Remoting Output. The output power can be controlled by the
remoting control pencil.

Technical Specifications
Power: 220V±22V, 50Hz±1Hz(110V±11V, 60Hz)
Operating frequency: 512KHz
Power rating: 880VA±10percent

Six working modes:


Monopolar Cut
a) Pure cut: 0W~300W( Load 800Ω)
b) Blend1: 0W~250W(Load 800Ω)
c) Blend2: 0W~150W(Load 800Ω)
Monopolar Coag
d) Contact Coag: 0W~80W( Load 800Ω)
e) Forced Coag: 0W~120W( Load 800Ω)
Bipolar
f) Bipolar Coagulation: 0W~50W( Load 100Ω)
Power Consumption: ≤880VA

Configuration Sheet
Electrosurgical Pencil: 5pcs

11
Power Control Pencil: 1pc
Electrosurgical Pad: 10pcs
Electrosurgical pad cable: 1pc
Footswitch: 1set
Bipolar Forceps and cable: 1set

12
Emergency stretcher trolley / manual / trauma / 2 sections
JE-100

Characteristics
 Type:
emergency
 Operation:
manual
 Other characteristics:
trauma
 Number of sections:
2 sections
Description
Overall Size: L1900 x W750 x H650mm
Frame is made of stainless steel 304#Backrest lifting are 0 ~ 80° (Hand-held)
Four 6" casters (Lockable x 2 & Directional x 2)
Joinable I.V. Pole x 2 (Each side)
Accessory: High density PU foam mattress covered with synthetic leather x 1

13