Você está na página 1de 7

Innovation Beyond Technology

Boiler Water Treatment


Chemicals

TM

Alkalinity Builder and Sludge Conditioner

FEATURES :
The control of boiler water pH and Ÿ Superior quality pH control agent
alkalinity levels are important issue steam boilers
affecting the operation and Ÿ Excellent performance with high
maintenance of boiler systems. temperature applications
Ÿ Maintain a protective coating of
iron oxides over the metals and
Contraxide is formulated using thereby prevent certain types of
strong alkaline treatment that can corrosion
be used in control of feedwater pH,
also contains sludge conditioning TYPICAL DOSAGE RANGE :
and scale preventing polymers. Contraxide is continuously dosed via
the feed tank, the rate of addition
being adjusted to maintain the correct
pH and alkalinity.
MECHANISM BASED ON :
DIRECTION :
Strong alkaline property of Contraxide
neutralizes any acid present and Allow the boiler to be conditioned for
contributing suitable alkalinity level to meet 24 hours then test the Alkalinity and
ideal condition of the boiler water. pH value. The boiler water must be
always conditioned as follows :
Contraxide also provide a proper Ÿ pH : 10-11.5
environment for precipitation of desirable Ÿ Total Alkalinity : 200-700 ppm
sludge materials.
MORE INFORMATION :
Email : pgt@patramasgroup.co.id
Website : www.patramasgroup.co.id
Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo


Innovation Beyond Technology

Boiler Water Treatment


Chemicals

TM

Super-catalyzed oxygen scavenger to prevent


corrosion in boiler and feedwater system

Corrosion by oxygen in the boiler


can be controlled by the addition of FEATURES :
Deox+ to the preboiler section of Ÿ Super fast oxygen removal just in
the steam generating systems. seconds
Ÿ Low cost and easy to handle
Ÿ Ideal treatment for low and medium
Deox+ is a powerful oxygen pressure boilers
scavenger that scientically Ÿ Ideal application for used in the
formulated from supercatalyzed food industry
sodium sulte to deliver protection
for both low and medium pressure TYPICAL DOSAGE RANGE :
steam boilers. Deox+ should be dosed at the rate
10 ppm for every ppm of dissolved
oxygen in the feedwater. A reserve of
approx. 50 ppm of sulte should be
MECHANISM BASED ON : maintained in the boiler water.
Deox+ is a high performance oxygen
scavenger that rapidly reacts with oxygen FEEDING :
ensuring efcient protection of feedlines Feed continuously and proportionally
and boilers from corrosion and enhancing into the feed water line. Use a
protection against caustic embrittlement. chemical injection pump for maximum
and stable treatment performance.
The oxygen scavenging property is
illustrated by the following reaction : MORE INFORMATION :
Email : pgt@patramasgroup.co.id
2Na2SO3 + O2 → 2Na2SO4 Website : www.patramasgroup.co.id
Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo


Innovation Beyond Technology

Boiler Water Treatment


Chemicals

TM

A unique blending technology of selected


boiler compound ingredients, oxygen
scavenger, scale inhibitors, corrosion
inhibitors and sludge dispersants
Boiler water treatment chemicals is
FEATURES :
necessary to prevent or control Ÿ Multifunctional properties within
corrosion and scale formation a single liquid product
Ÿ Ensures reliable effects against
Corrosion and scale-deposit corrosion, scaling and sludge
formation can causes tube failures, accumulation problems
restrict circulation, reduce system Ÿ Provides excellent corrosion control,
efciency and compromise your oxygen scavenging, scale inhibition
boiler system’s reliability. and sludge dispersion properties

TYPICAL DOSAGE RANGE :


Will vary depending upon system
characteristics, operation condition
MECHANISM BASED ON : and water qualities. An initial dosage
Corrover will stabilize the hardness salts up to 500 ppm is recommended.
present in the feed water, it will hydrolyse in
the boiler to form orthophosphates, then FEEDING :
combine with the calcium-magnesium Feed continuously and proportionally
compounds in the water to form insoluble into the feed water line. Use a
that can be blown down as sludge. chemical injection pump for maximum
and stable treatment performance.
The polyelectrolytes and hydrazine provide
synergistic protection against corrosion due MORE INFORMATION :
to chlorides, carbon dioxide and oxygen. Email : pgt@patramasgroup.co.id
Website : www.patramasgroup.co.id
Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo


Innovation Beyond Technology

Boiler Water Treatment


Chemicals

TM

Formulated for the cleaning of boiler


and treating of boiler-water
Boiler water treatment chemicals is
FEATURES :
necessary to prevent or control scale
Ÿ Multi-metal protection
and deposit formation.
Ÿ Excellent scale inhibition
Ÿ Cleans and treats boiler system
The formation of scale and sludge Ÿ Excellent thermal chemical stability
can causes tube failures, restrict
circulation, reduce system efciency ADVANTAGES :
and compromise your boiler Ÿ No handling of aggresive acids
system’s reliability. (such as HCl, HF, etc.)
Ÿ Reduced risk of corrosion of the
base-material required no
chloride-induced stress-corrosion
cracking of stainless steel parts
MECHANISM BASED ON :
Ÿ High iron-dissolving capacity
Treatment with sequestering agent,
Ÿ Short cleaning time
ethylene diaminetetra acetic acid to form
stable, water-soluble complexes with all TYPICAL DOSAGE RANGE :
metal ions normally present in boiler-scales Descal : 5-10% (mass/mass)
(Ca, Mg, Fe, Cu, Co, and Ni).

Since dissolution of Fe3O4 is rate


determining in the cleaning process.
Descal is the preferred sequestering agent, MORE INFORMATION :
since it effectively dissolves iron oxides. Email : pgt@patramasgroup.co.id
Website : www.patramasgroup.co.id
Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo


Innovation Beyond Technology

Boiler Water Treatment


Chemicals

TM

Heavy duty inhibited acid cleaner for boiler


scale removal and descaling HE which are
Contaminated boiler and steam choked with lime-scale and other deposits
systems require chemical cleaning FEATURES :
to remove contaminants that Ÿ Highly effective for removing most
impair heat transfer and leads calcium and iron deposits
ultimately cause tube failure. Ÿ Low cost and easy to handle
Ÿ Complete removal complex deposits
Chemical cleaning reveals the true FACT AT A GLANCE :
boiler metal condition, allowing
the systems to restore its maximum Thickness of Deposit Fuel Wasted
(mm) (%)
performance 0.85 7
1 9
1.3 11
MECHANISM BASED ON : 1.6 13
Descal is special formulated cleaner that 2.3 15
2.8 16
consists of inhibited acids and strong
chelants to aid in the removal of calcium, DIRECTION :
magnesium and iron deposits. Descal also Each chemical cleaning stage lasts for
accelerate the removal of certain complex approximately 6 to 24 hours.
and stubborn scales. Only qualied personnel should be
involved in solvent selection, planning
Most internal deposits can be removed by and supervision of the cleaning.
Descal by acid cleaning method. The
chemical cleaning is generally performed
MORE INFORMATION :
before initial operation to prevent Email : pgt@patramasgroup.co.id
contaminant damage or water chemistry Website : www.patramasgroup.co.id
upsets. Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo


Innovation Beyond Technology

Boiler Water Treatment


Chemicals

TM

Synergistic neutralizing amines


and special corrosion inhibitor
by forming protective lms
CO2 reacts with the condensate to
form carbonic acid. Without chemical FEATURES :
treatment, this acid reduces the pH of Ÿ Effective in many industrial
the condensate and leads to condensate systems
Ÿ Suitable for systems with medium to
corrosion attack of steam line.
long condensate runs
Ÿ Suitable for wide type of metals
The pH can be controlled within a
specied non-corrosive range by the TYPICAL DOSAGE RANGE :
continuous dosage of a neutralizing Termamine should be dosed at a rate
amine, such as Termamine. dependent on the amount of CO2
present in the steam and will be
established Patramas Group to suit
the particular circumstances.
MECHANISM BASED ON :
FEEDING :
Termamine is a blend of a synergistic
Termamine should be diluted with
neutralizing amines designed to control
clean water and injected continuously
corrosion in condensate systems by
by metering or dosing pump. For
providing correction of pH levels in
maximum effectiveness, condensate
condensate throughout the systems.
pH levels in range of 8 - 9 should be
maintained.
Termamine provides suitable pH to form
protective hydrophobic lm which effective
in isolating the metal surfaces from water. MORE INFORMATION :
Email : pgt@patramasgroup.co.id
Website : www.patramasgroup.co.id
Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo


Innovation Beyond Technology

Boiler Furnace
Fire-side Treatment

TM

Special formulated for safe removal of soot


and deposits from boilers and diesel engine
If deposits are allowed to form on exhaust systems
heat exchangers, the loss of
FEATURES :
efciency can be directly related to Ÿ Reduces soot and reside slag deposits
extra fuel consumption. Ÿ Reduces cold-end corrosion
Ÿ Improves heat transfer and reduces smoke
A 1 mm deposit is approximately Ÿ Assists soot blowing
equivalent to a 10% efciency loss, ADVANTAGES :
a 3 mm deposit can reduce Ÿ Increases boiler efciency
efciency by up to 50%. The normal Ÿ Reduces cleaning costs by decreasing
ignition temperature of soot is maintenance and frequency of cleaning
around 600°C. Ÿ No need to shut down boiler or plant
when dosing
TYPICAL DOSAGE RANGE :
Steam Raised Boiler Fuel TrueBurn Dose
MECHANISM BASED ON : (tons/hr) (tons/day) (kg/day)*
TrueBurn clean the soot layers at 12 21 3.5
combustion chamber and exhaust systems. 15 27 4.0
In normal conditions the ignition point of 23 41 4.5
o 31 55 5.0
soot and ashes are around 600 C.
46 82 5.5
62 110 6.5
Due to its catalytic action, continuous *spread through the ame path or mixed with fuel
dosing of TrueBurn drops the ignition point
of soot and ash to approx. 250oC. The soot
MORE INFORMATION :
and ash deposit thus ignited, leaving an Email : pgt@patramasgroup.co.id
easily removed ash. Website : www.patramasgroup.co.id
Phone : (+6221) 8795 3501

Innovation Beyond Technology PT Patramas Global Techindo

Você também pode gostar