Você está na página 1de 103

product catalogue

Camfil Farr Air Filter Products and Services

Air Filtration Solutions

Camfil Farr – clean air solutions

Cover 1_4 UK 080612.indd 2 2008-06-16 13:38:12


Dear Customers,
I am pleased to present to you this latest edition of the Camfil Farr air filter
solutions catalogue. We have made every effort to make it more practical and
fully comprehensive. We are also making it available to you in the form of the
enclosed CD-Rom.

The catalogue contains up to date information and technical performance


data on our range of air filtration products. This issue also contains summary
information of the various test standards that need to be considered when All HEPA filters are
individually tested to
making your selection. We have also included an application guideline section EN 1822
which will enable you to quickly identify the correct air filter for your application.

Camfil Farr are the world leader in providing air filtration solutions and the
product range includes many world class benchmark filters. In addition to
providing a comprehensive range of quality products, we at Camfil Farr believe
that service is of paramount importance. In today’s fast moving industries the
ability to get goods to where they are needed quickly and correctly is vital.

To ensure that our “right first time” service matches our “best in class” products
we are developing our logistics and expanding our fleet of dedicated delivery
vehicles. This unique service will ensure that your goods arrive where you want
them, when you want them. Finally, I would strongly recommend that you visit
the www.camilfarr.co.uk website where you can access much more detailed Advanced fabrication
information about our products and services, and the latest news on our capability

“CLEAN AIR SOLUTIONS”.

Enjoy your reading K


ANY SC
RL APE : 748
- Code

Bill Wilkinson
COMP 363 460
ATION is B 393
RTIFIC
NT CE RCS Par
EUROVE is FRANCE -
N° :
iploma
Par
l 75003
ation D
astopo

Certific
Séb
62 Bd de

Managing Director 34
07.01.3

fies that
ny certi
Compa
-F9
lass F5
fication
NT Certi
EUROVE ers C
Fin e Air Filt from P
ROU
F ARR G
CAMFIL Located at OSA Sw
eden
933 TR
3 , 61
igatan me
Industr Trade na
Camfil

ard
ng stand
of followi
ments
require
ing the
1-2006
cord
ssed ac
have be
en asse OM-1
d at :
displaye
ucts is n.com
fied prod ificatio Comprehensive stocks
The list
of certi
urov ent-cert
http:// www.e backed by integrated
P ance wi
th the ru
les inhouse logistics
GROU accord
L FARR mark in
CAMFI fication ual
NT Certi al Man
e th e EUROVE in the Operation
us d 2006
ised to specifie OM-11-
is author

31/01/07
al date
: 31/12/07
IST Approv
31/03/09
:
s BENO cked on
Jacque certification Re-che til :
Directo
r of Valid un

Cover page 2 UK 080612.indd 1 2008-06-16 13:27:43


Index - Camfil Farr

Camfil Farr Solutions


Pre-Filtration, Class G3 to F5 Carbon and Chemical Filters

30/30 ............................................................18 CityFlo ............................................................ 62


Aeropleat PP .......................................................19 CityCarb® .......................................................... 63
Camglass GP .......................................................20 CitySorb ............................................................ 64
Pad Holding Frame ..............................................21 Camcarb Green ................................................... 65
EcoFlo ............................................................22 Camcarb Mounting Frames ................................... 66

Pre-Filtration, Class G3 to F5
Cam Glass Media .................................................23 Camsure ............................................................ 67
Synthetic Media Rolls ..........................................24
Fan Coil Filter .....................................................25 Housings, frames & special applications
Hi-Cap® 30P, 40P, 50P ......................................26
Absolute Filter Holding Frame .............................. 70
Bag and Compact Filters, Class F5 to F9 Type 8 - Filter Holding Frame ............................... 71
FCB-P ............................................................ 72
Hi-Flo® M-Series .................................................29 FCBS-HF ............................................................ 73
Hi-Flo® P, PL-Series ...........................................30 FCBS-A ............................................................ 74
Hi-Flo® U-Series .................................................31 FCBL-CC ............................................................ 75

Bag and Compact Filters,


Hi-Flo® A-Series .................................................32 FCBL-CS ............................................................ 76
Hi-Flo® T-Series .................................................33 FCBL-HF ............................................................ 77

Class F5 to F9
S-Flo W P Series ..................................................34 Pharmaseal ......................................................... 78
S-Flo W U Series .................................................35 Camsafe ............................................................ 79
S-Flo W A Series ..................................................36 Termikfil 2000 ................................................... 80
Opakfil Green ......................................................37 Absolute® 1FRK ................................................. 81
Ecopleat & Ecopleat MCTA ...................................38 Paint Extract Filters ............................................. 82
Riga-Flo ............................................................39 Airopac® HT-HF ................................................. 83
OpakAir ............................................................40 Panolair SSI - Micretain H10 ............................... 84
Airopac® ............................................................41 CDM Media ........................................................ 85

H E PA / U L PA F i l t e r s , C l a s s
Cam GT® ........................................................... 86
HEPA / ULPA Filters, Class H10 to U17 Campulse EF ...................................................... 87

H10 to U17
Hi-Flo® T ........................................................... 88
Sofilair - H10 to H14 ...........................................45 Gold Series ......................................................... 89
Sofilair Green ......................................................46 HemiPleat Cartridges ........................................... 90
Close Pleat - H13 ................................................47
Opakfil G Micretain - H10 ....................................48
Megalam MD, MX, MG .........................................49
Megalam MX & MG - H14 ....................................50
Megalam MD - H10 & H14 ...................................51

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Megalam MD & MG - U15 ....................................52


Megalam (Laminator) MDL & MXL - U15 & U16 .....53
Silent Hood Diffuser - H14 ...................................54
Megalam U (Gel) - H14 & U15 .............................55
Megalam T (Gel) - H14 & U15 ..............................56
Megalam MD & MX e-PTFE - U15 .........................57
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

1
Camfil Farr Solutions

Quick Selection Guide


Filter Grade Air Filter Selection

Primary Filters

G2 ≥ 65%

Medium Efficiency

Primary Filters

EN 779:2002
G3 ≥ 80%
Primary Filtration

G4 ≥ 90%
EN 779:2002
Average Arrestance

Fine Filters

F5 ≥ 40%
High Efficiency

EN 779:2002
F6 ≥ 60%
Fine Filters
Pre-Filtration for HEPA/
Conditioning Systems.

F7 ≥ 80%
F8 ≥ 90%
Filtration for Air

F9 ≥ 95%
ULPA Filters

EN 779:2002
Average Efficiency

DOP 0,3 um MPPS (Most Penetrating Particle Size)


≥ 95% H10 ≥ 85%
Very High Efficiency
Class according to Fed. Std 209 E

≥ 99,9% H11 ≥ 95%


100 000
Clean Room Filters

HEPA

≥ 99,97% H12 ≥ 99,5%


EN 1822

≥ 99,99% H13 ≥ 99,95%


10 000
Final Filters /

100 to 1000

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
≥ 99,999% H14 ≥ 99,995%
U15 ≥ 99,9995%
ULPA

U16 ≥ 99,99995%
1 to 10

U17 ≥ 99,999995%
Molecular

CityFlo, CitySorb,
CityCarb, Camcarb
Filter Holding
Frames and
Casings

Filter Housings, Camseal, FC Casings,


Type 8 Frames etc.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

2
Camfil Farr Solutions

Caring for the Environment

“How will your filters help you to reduce


the environmental impact of your
installations?”
Camfil has been involved in air quality for over 40 years, and has to set
an example when it comes to the environment. It therefore has an
obligation to provide its customers with practical assistance on green
issues. With regard to complying with the law on waste disposal, Camfil
is with you all the way; in designing products and services, Camfil
shares your environmental concerns.
It is now widely acknowledged that air conditioning filters can be
considered ordinary industrial waste, whereas filters used in Follow up CFM
environments containing potentially hazardous products (e.g. return air
from clean rooms, spray booths and operating theatres) should be Conscious of the increasing importance attached by our customers to
considered special industrial waste and must be disposed of by an waste management, Camfil can support you and take charge of
approved route using accredited systems. replacing and organising the disposal of certain used filters as part of its
CAMFIL FILTER MANAGEMENT (CFM) programme. For more information
Please Note - your individual circumstances depend entirely on your and to find out whether this service might work for you, please contact
processes and we recommend that you approach your usual waste us.
disposal provider, who will be qualified to advise you on the matter.

In order to minimise waste, Camfil pay


close attention to the life cycle of the
product:
1. We make strenuous efforts to extend the lifespan of our filters and to
optimise their performance, which means that you reduce your
operating costs, the frequency with which you have to replace the filters
and the cost of their disposal.
Just look at the large filter surface used in many of our products and
remember large filter area is synonymous with long filter life.
2. We favour the use of recyclable or incinerable materials.
3. We are continually researching effective materials with low pressure
loss, a parameter that has a direct influence on the energy consumed
during the lifetime of the filter.
4. The Green CAMFIL range ensures that you can dispose of your used

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
filters with less hassle and at lower cost. The use of plastics or
cardboard lends itself to the incineration of used filters whilst ensuring
compliance with all provisions of environmental law.
5. We minimise the weight of materials used in the construction of our
filters which helps reduce the waste mass as far as possible when the
filter reaches the end of its life.
6. In our ISO 14001 certified factories, we are phasing out the use of
chloride solvents and hazardous products from our processes.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

4
Camfil Farr Solutions

Camfil Farr Solutions


Services

Camfil Academy: Filter installation upgrade service


Before After
Become the air filtration specialist in
your company

Pre-Filtration, Class G3 to F5
In addition to providing up to date air filtration solutions Camfil Farr can
provide a structured training program covering all aspects of air
filtration engineering. Adapted to suit your needs the training includes
information on how to specify and select air filters, air filter standards,
indoor air quality legislation, air filter application, and reducing energy Air filter system validation service
and environmental impact.

Bag and Compact Filters,


By fitting energy efficient filters and maintaining ventilation systems real
energy savings can be made quickly. Maintained correctly these will

Class F5 to F9
translate into long lasting real reductions in cost and environmental
impact. Camfil can provide a comprehensive package of air hygiene
services that will ensure your systems are healthy, legislation compliant,
and cost effective.

Camfil On-Site Expertise:

H E PA / U L PA F i l t e r s , C l a s s
Camfil Filter Management

H10 to U17
Camfil has a fresh approach to managing on-site air filtration services.
We understand that filtration is required for protecting people’s health,
ensuring legislative compliance and protecting valuable investments.
Performance Managed Supply
We have our own site service team that can manage all aspects of your Camfil complete the “cradle to grave” responsibility for all your filtration
air filter requirements by offering a wholly inclusive service package. needs by providing a unique logistics system at the centre of which is a
national transport fleet. This dedicated fleet of vehicles with trained
employees ensures that you get your goods when and where you need
them. To complete the service, we can remove and dispose of used

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

filters together with providing all of the required certification.

Ensuring safe and efficient running of effective air filtration systems


demands a multi-disciplined service solution. These extend beyond
comprehensive logistics to ensuring that filters are fitted correctly,
working efficiently, and optimised to reduce the overall cost of
ownership for the lifetime of the installation.
Filter Frames and Housings

In order to comply with current legislation and reduce cost of ownership


of some installations, upgrading work is required. Camfil can provide a
joined up solution which includes selection, supply, fitting,
A i r F i l t e r Te c h n o l o g y

commissioning and validation of any new or upgraded installations.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

3
Camfil Farr Solutions

Caring for the Environment

“How will your filters help you to reduce


the environmental impact of your
installations?”
Camfil has been involved in air quality for over 40 years, and has to set
an example when it comes to the environment. It therefore has an
obligation to provide its customers with practical assistance on green
issues. With regard to complying with the law on waste disposal, Camfil
is with you all the way; in designing products and services, Camfil
shares your environmental concerns.
It is now widely acknowledged that air conditioning filters can be
considered ordinary industrial waste, whereas filters used in Follow up CFM
environments containing potentially hazardous products (e.g. return air
from clean rooms, spray booths and operating theatres) should be Conscious of the increasing importance attached by our customers to
considered special industrial waste and must be disposed of by an waste management, Camfil can support you and take charge of
approved route using accredited systems. replacing and organising the disposal of certain used filters as part of its
CAMFIL FILTER MANAGEMENT (CFM) programme. For more information
Please Note - your individual circumstances depend entirely on your and to find out whether this service might work for you, please contact
processes and we recommend that you approach your usual waste us.
disposal provider, who will be qualified to advise you on the matter.

In order to minimise waste, Camfil pay


close attention to the life cycle of the
product:
1. We make strenuous efforts to extend the lifespan of our filters and to
optimise their performance, which means that you reduce your
operating costs, the frequency with which you have to replace the filters
and the cost of their disposal.
Just look at the large filter surface used in many of our products and
remember large filter area is synonymous with long filter life.
2. We favour the use of recyclable or incinerable materials.
3. We are continually researching effective materials with low pressure
loss, a parameter that has a direct influence on the energy consumed
during the lifetime of the filter.
4. The Green CAMFIL range ensures that you can dispose of your used

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
filters with less hassle and at lower cost. The use of plastics or
cardboard lends itself to the incineration of used filters whilst ensuring
compliance with all provisions of environmental law.
5. We minimise the weight of materials used in the construction of our
filters which helps reduce the waste mass as far as possible when the
filter reaches the end of its life.
6. In our ISO 14001 certified factories, we are phasing out the use of
chloride solvents and hazardous products from our processes.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

4
Camfil Farr Solutions

Camfil Farr Solutions


Would you like to reduce your energy outgoings?

70% of the total cost comes from energy


costs
Calculations show that energy normally accounts for 70% of the total
cost of the life cycle of an air treatment system. Energy consumption is

Pre-Filtration, Class G3 to F5
in direct proportion to the filter’s average pressure loss.

100

80
70
60

40

15 20
Economic optimisation of air filtration 8 5

Bag and Compact Filters,


2 %
The price of crude oil has more than doubled in recent years and the

Class F5 to F9
cost of electricity is rising throughout the world. The World Bank’s t t t t t
y Cos r Cos g Cos r Cos l Cos
Energy Group has predicted that total energy consumption is set to rise erg i l t e i n b o u o s a
En F a n La p
at the current rate for at least the next 50 years. Cle Dis
The cost of ventilation
Ventilating buildings, as we know, can be a very expensive business. The
Choosing the right filter saves energy
average energy cost of filters is around 30% of the total costs of the In order to optimise the lifespan of the filter and to reduce energy
system. By choosing the right filter, for example the F7 for its efficiency consumption, it is important to bear in mind the extent to which their
and its very low average pressure loss, energy savings can be made configuration and their structure influence the average pressure loss.
whilst maintaining a high level of IAQ. When you consider that the air

H E PA / U L PA F i l t e r s , C l a s s
filter is the most inexpensive and simplest component to change,
savings can be made quickly.
Tapered pockets

H10 to U17
Parallel pockets

Blocked surface = high energy consumption

Carbon and Chemical Filters


Software aimed at helping select the
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

right filter = optimising energy costs


For over 40 years, Camfil Farr has played a pioneering role in designing
filters with low average pressure loss for all efficiency levels for air
conditioning and ventilation systems. Camfil Farr was the first filter
manufacturer to develop sophisticated software that calculates the
overall cost for the complete life cycle of air filters. As part of our
Typical pressure loss (Pa) in a ventilation system with 2 stage filtration continuous improvement, this software has evolved over time and it
uses real life data collected from numerous tests in real use conditions.
This enables us to calculate the pressure loss of the filter and its actual
Filter Frames and Housings

1Pa = 1 euro lifespan, rather than relying on theoretical calculations.

A rule of thumb, for a typical installation running for half of the time over For more information and assistance, please contact your
one year, is that one additional Pascal in pressure drop adds 1 euro per nearest branch of Camfil Farr.
filter in extra energy cost.
A badly designed filter construction could add 50 Pascal compared to a
well engineered filter, even if it claims to have the same efficiency. In
other words it adds 50 euros to the annual energy bill, for every filter.
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

5
Camfil Farr Solutions

Energy & Air Quality Rating

We have made choosing filters as easy as cases we have seen that air filters may be responsible for as much as
30 percent of the total energy consumption in an air-handling unit.
ABC. Consequently, there is substantial profit to be made by choosing wisely.
The newly developed Energy & Air Quality Rating makes it easy to The Energy & Air Quality Rating helps you control your energy
reduce energy consumption and at the same time, it guarantees the air consumption. That will save you money. Actually, a lot of money.
quality. These two critical factors were taken into consideration during
the development of our new classification system. If a filter achieves a Why one of the leading filter companies
good grade, it is because it cuts costs and makes the air clean. It’s as
simple as that. cares.
We believe in transparency and honesty. The filter industry is clouded by
Honestly, how did you choose filters numbers and figures, making it virtually impossible to compare different
filters. We want to clean up the mess. Surely, the customer will profit
before? from having all the facts when deciding which filter to
Selecting the correct air filter has never been easy but choose. We believe that the industry itself will benefit from a common
the Energy & Air Quality Rating changes that. Using the standard, since it puts pressure on developers to make energy efficient
rating system, it’s easy to choose the right air filter for filters. When a company develops an excellent filter, we think it should
your needs. It’s important however, to be aware that an be rewarded with an “A”.
A-filter is not always the right choice for you. The top
rating may be appropriate for a medical or food
application where the demand for air quality is critical.
Conversely, a G-filter may be the best choice for a low-
Objectively tested.
grade storeroom. Whatever your budget and your Filter efficiency in actual use was an essential parameter when
requirement for air quality, there will be a rating letter to developing the Energy & Air Quality Rating. To guarantee independent
meet your needs. The selection process will be both verification of the discharged efficiency value, we collaborated with the
easy and precise. Technical Research Institute of Sweden (SP) - a leading organisation in
the development of sustainable energy and environmental technology in
Europe. The data was obtained through long-term measurements,
performed under realistic conditions.
It’s not just about new EU energy

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
concepts, it’s about your grandchildren. As you can see, the advantages are
The new and more stringent requirements aim to make your company obvious.
more energy efficient but the most important aspect is much closer to
home. At Camfil Farr, we are constantly striving to develop new
technologies and methods that make us even more environmentally
friendly. We want to give our children and our grandchildren the
opportunity to grow up in a clean environment. At the end of the day,
that’s what matters most.
Well, maybe not crystal clear. Differentiating air filters is a complex
matter. Many variables impact a comparison study, and not all are self-
This symbol will speak volumes in your evident. Laboratory tests are made under controlled conditions and test
protocols are an imperfect compromise of actual conditions. In actual
annual report. use, most air filters will remain in a system for months or even years.
During that time, an air filter will see hundreds of environmental changes
such as temperature, humidity, airflow velocity and particle load. Add to
this the fact that it is not impossible for suppliers to manipulate
observations or data to best suit their needs. With the Energy & Air
Quality Rating all you really need to look at is a single letter. All in all, we
like to think the advantages are quite obvious.

The cost of energy is at an all-time high and will continue to increase. It


has never been more important to strive for energy efficiency. In some

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

6
Camfil Farr Solutions

Camfil Farr Solutions


Indoor Air Quality (IAQ)

Environmental Health hydrocarbons are emitted by the incomplete burning of fuels or carbon,
which can usually be found in the air, linked to particles. Some of them
Environmental health is becoming a central concern at national and are known to be highly carcinogenic.
international levels. Indoor Air Quality (IAQ) is an area that focuses on
providing a comfortable and healthy indoor environment which is
important to the well being of people. We spend 80% of our time in

Pre-Filtration, Class G3 to F5
indoor spaces and, as such, the issue of IAQ is a key aspect of public
health, especially since this affects the entire population, particularly the
most sensitive and vulnerable.
The industrialised world is a very different place compared to 50 years
ago and one major difference is that the air we breathe is now more
heavily and more diversely polluted than at any time in the past.
Although natural sources of pollution exist, the greater concerns arise
as a result of mans own activities which have increased both the amount
and the complexity of pollutants found in the atmosphere. There are tens
of thousands of synthetic chemicals (not found in nature) made today
with an estimated annual production rate in excess of a billion tonnes.

Bag and Compact Filters,


These chemicals are released to the atmosphere during
manufacture use and can subsequently travel vast distances. They are Secondary pollutants

Class F5 to F9
an inevitable part of our lives Secondary pollutants are substances whose presence in the
. atmosphere is the result of chemical transformations related to the
interaction of compounds known as precursors. Ozone is the main
secondary pollutant, it is formed as a result of a photochemical process
in the presence of certain primary pollutants (carbon monoxide, nitric
oxide and volatile organic compounds). This is a gas that is naturally
present in the atmosphere in low concentrations at high altitude. At low
altitude, on the other hand, the development of the concentration is
primarily the result of human activity. Sulphuric acid and nitric acid form

H E PA / U L PA F i l t e r s , C l a s s
in the atmosphere as a result of humidity from sulphur dioxide and nitric
oxide respectively.

H10 to U17
Solid pollutants
Solid pollutants usually in the form of small (fine) particles are very
important and from a cleanliness point of view, these particles deserve
particular attention. These are capable of acting as vectors to other
substances, such as carcinogenic polycyclic aromatic hydrocarbons,
Atmospheric pollution which is particularly worrying given the capacity of the finest particles (<

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1μm) to find their way into the lungs and even to penetrate into the
Atmospheric pollution can be categorised in two different ways. The bloodstream. Effective solutions aimed at combating such particle
simplest is measurement (a physical categorisation) to distinguish pollution are now widely known. The development of the main standards
gaseous pollutants from solid, dust and particulate pollutants. The and recommendations governing the manufacture and use of modern air
second is based on the origin of pollutants and is divided into primary filters is clearly geared towards much higher filtration levels than have
and secondary pollutants. been permitted in the past

Primary pollutants City


Primary pollutants are substances present in the atmosphere, in the Our range of ‘CITY’ filters has been developed with the sole purpose of
form in which they are emitted. Of these pollutants, some are especially combating atmospheric pollution and its major components.
Filter Frames and Housings

prominent:
Sulphur dioxide (SO2) emitted by certain industrial processes, such as CITYCARB and CITYFLO combine particulate filtration with pollution
paper-making and refining, and in particular by the use of sulphurous and odour filtration. They are suitable for any new installation and can be
fossil fuels. SO2 is one of the main causes of acid rain on account of its readily installed to upgrade and improve systems currently equipped
transformation in the atmosphere into sulphuric acid (H2 SO4). Nitric with standard filters.
oxides (NOX), and in particular nitrogen dioxide (NO2), which is usually With its higher molecular adsorption, CITYSORB is ideal for highly
emitted from the burning of fossil fuels (particularly vehicles), contribute polluted urban environments. CITYSORB must be fitted in conjunction
towards the formation of ozone in the atmosphere. Polycyclic aromatic with a particulate filter above F7 efficiency, HIFLO or OPAKFIL type.
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

7
Camfil Farr Solutions

AT E X

ATEX Directive: Explosive atmospheres biopharmaceutical applications, some procedures must use ATEX-
classified filters in certain places (please see table). Camfil Farr in
Two important new safety directives have entered into force in Europe. Europe has developed HEPA filters and ATEX accredited housings for
These new regulations come under the title of ATEX Directives and apply use in biopharmaceutical installations in order to prevent electrostatic
to manufacturers, suppliers and users of equipment intended for use in dangers caused by gas or dust in an ATEX area. Camfil Farr has
potentially explosive atmospheres (dangerous areas). An explosive developed specific versions of ATEX for most filters and housings used
atmosphere is defined as a mixture with air, under atmospheric in biopharmaceutical installations in order to prevent electrostatic
conditions, of hazardous substances in the form of gases, vapours, dangers caused by gas or dust in an ATEX area. Camfil Farr’s ATEX
mists or dusts in which, after ignition has occurred, combustion spreads solutions are entirely certified in accordance with the requirements of
to the entire unburned mixture. The 99/92/EC (ATEX 137) Directive, the ATEX Directives with the appropriate EX marking, the ATEX
known as the ‘User Directive’ requires employers to protect their conformity statement and the instructions for use.
employees from the risks posed by explosive atmospheres. The 94/9/
EC (ATEX 95 or ATEX 100A) Directive on ‘Equipment and protective
systems intended for use in potentially explosive atmospheres’ covers Key to the table:
electrical and non-electrical products intended for use in hazardous Definition of ATEX areas and corresponding product categories.
places (gases, vapours, mists). Conformity with the ATEX Directives has
Definitions of areas
been a legal requirement in all EU Member States since 1 July 2003. In

Dust Category
Gas Definitions Typical suitability of place
Areas ATEX
0 20 1G Equipment adapted to 0 areas
Place where an explosive atmosphere is permanently present
1D Equipment adapted to 20 areas
1 21 Place where an explosive atmosphere is probable occasionally under normal 2G Equipment adapted to 1 areas
operating conditions 2D Equipment adapted to 21 areas
2 22 Place where an explosive atmosphere is improbable under normal operating 3G Equipment adapted to 2 areas
conditions, but, where applicable, only lasts a short time. 3D Equipment adapted to 22 areas

All Camfil Farr ATEX air filtering solutions


All Camfil Farr ATEX air filtering solutions are certified for use in explosive gas atmospheres (Classes 1 and 2) and explosive dust atmospheres (Classes
21 and 22). They comply with European Standard EN 13463-2001 Annex C Non-electrical equipment for potentially explosive atmospheres, as attested
by the conformity statement attached to these products.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

8
Camfil Farr Solutions

Camfil Farr Solutions


Public Buildings

Concerns over public health have resulted in increased awareness about indoor air quality (IAQ). We now spend approximately 80% of our time in indoor
spaces and legislation now requires that these spaces are comfortable, safe and without risk to health. Camfil Farr filters for air conditioning systems
help to safeguard human health by preventing airborne contamination from entering these environments. In addition correctly selected and maintained air
filters keep air conditioning systems clean ensuring that they perform in accordance with design parameters. Camfil Farr’s extensive range of comfort air

Pre-Filtration, Class G3 to F5
filters, are typically used in offices, schools and shopping centres etc.

1, 2, 6, 7 or 8 1, 2, 3, 4, 5 or 6

5 or 9 5

5
5 or 9
1, 2, 6, 7 or 8

Bag and Compact Filters,


3 or 4

Class F5 to F9
5 3, 10

H E PA / U L PA F i l t e r s , C l a s s
IAQ recommendations

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1. Hi-Flo 2. Opakfil Green 3. Citycarb 4. City-Flo 5. Ecopleat

Filter Frames and Housings

6. S-Flo 7. Hi-Cap 8. 30/30 9. Fan Coil Filter 10. Eco-Flo


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

9
Camfil Farr Solutions

Hospitals and Healthcare

Nowhere is air filtration more important than in health care facilities. Air filters offer excellent protection from airborne diseases in health care facilities,
provided that they form part of an overall air quality control programme. Camfil Farr provides a comprehensive solution that ensures the provision of this
quality. Our extensive scope of supply ranges from providing air filters to satisfy the most demanding standards, air filter housings, system validation and
monitoring, filter management, and specialist consultancy services. Our products provide safe and comfortable environments for patients, visitors and
healthcare professionals.
1 2

3, 4
5, 6 5, 6
6, 8

7, 9 7, 9

Hospital and Healthcare recommendations

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1. Hi-Flo F7 2. Opakfil Green F8 3. Sofilair H13 4. FC-Filter Casing 5. Sofdistri

6. Megalam MDA 7. Ecopleat 8. CamHOSP2 9. Sofdistri Exhaust


details on request

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

10
Camfil Farr Solutions

Camfil Farr Solutions


Pharmaceutical Industry

For more than forty years Camfil Farr has been a leading supplier of air filter products and services to the Bio-Pharma Industry. Many of our clients have
multiple facilities located around the world. Camfil Farr is viewed by many of the largest pharmaceutical manufacturers as a partner and well positioned
to support their air filtration demands on a local and global basis.

Pre-Filtration, Class G3 to F5
1 2 3, 14

6, 8 7, 8, 9, 10 4, 5

Bag and Compact Filters,


3, 12, 13

Class F5 to F9
8, 11 3, 11, 15

H E PA / U L PA F i l t e r s , C l a s s
Pharmaceutical Industry recommendations

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1. Hi-Flo F7 2. Opakfil Green F7 3. Sofilair H13 4. CamGrid 5. Megalam T "U"

Filter Frames and Housings

6. Pharmaseal 7. Softdistri 8. Megalam MD 9. Softdistri Polyester 10. Megalam Green

11. Sofdistri Exhaust 12. Camsafe 13. Airopac/Opakair 14. FC - Filter Casing 15. Ecopleat F6
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

11
Camfil Farr Solutions

Food Industry

Protecting human health is a major concern for governments throughout the world. In many countries agencies associated with food safety have the
authority to take direct action against manufacturers who fail to ensure the safety of foodstuffs that they produce. To prevent the air conditioning system
from becoming contaminated, temperature, humidity and cleanliness must be closely controlled. Talk with the experts in clean air solutions - Camfil Farr.

1, 2 3

3
4, 5
6, 7

8, 9, 10

Food Industry recommendations

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1. Hi Flo F7 2. S-Flo F7 3. Opakfil F8 4. Sofilair H13 5. FC - Filter Casing

6. Sofdistri 7. Megalam 8. Sofdistri Exhaust 9. 30/30 10. Ecopleat

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

12
Camfil Farr Solutions

Camfil Farr Solutions


Automotive Industry

Few industrial applications demand such a clean working environment as painting facilities. Paint spraying facilities require a constant supply of fresh air
for hygiene and safety reasons. We currently provide clean air and services to many major automotive plants throughout the world. We provide the best
possible cost effective clean air solutions, customised and performance-optimised to meet your demands. Supplied and delivered exactly according to
your needs – by Camfil Farr.

Pre-Filtration, Class G3 to F5
8, 9, 1, 2, 3 8, 9, 1, 2, 3 8, 9, 1, 2, 3 8, 9, 1, 2, 3

Bag and Compact Filters,


Class F5 to F9
5, 6 or 7 4

H E PA / U L PA F i l t e r s , C l a s s
Automotive Industry recommendations

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1. Hi-Flo 2. S-Flo 3. Opakfil 4. Airopac HT/Panolair HT 5. CDM-600

Filter Frames and Housings

6. Panolair 7. Camgrid SM 20 8. 30/30 9. Hi-Cap


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

13
Camfil Farr Solutions

Microelectronic Industry

Advanced production methods often require very clean air, and as technology advances these requirements look likely to increase. Camfil Farr is
recognised as the leading supplier of high efficiency filtration products for the microelectronics industry. HEPA/ULPA filters are produced within controlled
environments in our ISO 9000-certified plants and are individually tested and certifed to ensure compliance. Our large production capacity ensures the
availability of our products at all times throughout the world.

1, 2 2, 3, 4

4, 5

7 6 8 1, 2 or 3
1, 2

2, 3, 4
4, 5 4, 5

Microelectronic Industry recommendations

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1. Hi-Flo F7/F8 2. Opakfil Green F8/H10 3. Camcarb 4. Sofilair H13/H14 5. Gigapleat

6. Silent Hood 7. Megalam MX MG 8. Megalam U

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

14
Camfil Farr Solutions

Camfil Farr Solutions


Gas Turbines, Air Filters and Systems

Camfil Farr provides systems solutions for the turbo machinery and power systems industry. Our solutions include filters, ducting, fans, silencers, and de-
icing. With more than 40 years of experience, Camfil Farr delivers value to customers worldwide whilst providing everyone with something essential -
clean air.

Pre-Filtration, Class G3 to F5
1, 2, 3, 4, 5, 8
6, 7

Bag and Compact Filters,


Class F5 to F9
H E PA / U L PA F i l t e r s , C l a s s
Gas Turbine, Air Filters and System recommendations

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1. 30/30 2. Hi-Flo 3. Hi-Cap 4. Ecopleat 5. Cam GT

Filter Frames and Housings

6. CamPulse EF 7. HemiPleat 8. Camclose


details on request Not availible in all countries
- see: www.camfilfarr.com
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

15
Camfil Farr Solutions

Camfil Farr Solutions


Gas Turbines, Air Filters and Systems

Camfil Farr provides systems solutions for the turbo machinery and power systems industry. Our solutions include filters, ducting, fans, silencers, and de-
icing. With more than 40 years of experience, Camfil Farr delivers value to customers worldwide whilst providing everyone with something essential -
clean air.

Pre-Filtration, Class G3 to F5
1, 2, 3, 4, 5, 8
6, 7

Bag and Compact Filters,


Class F5 to F9
H E PA / U L PA F i l t e r s , C l a s s
Gas Turbine, Air Filters and System recommendations

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1. 30/30 2. Hi-Flo 3. Hi-Cap 4. Ecopleat 5. Cam GT

Filter Frames and Housings

6. CamPulse EF 7. HemiPleat 8. Camclose


details on request details on request
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

15
Camfil Farr Solutions

Notes

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

16
Pre-Filtration, Class G3 to F5

Camfil Farr Solutions


Summary Pre-Filtration, Class G3 to F5

Pre-Filtration, Class G3 to F5
Pleated Filters Pleated Filters Panel Filters Pad Filters
30/30 Aeropleat PP Camglass GP Pad Holding Frame
Page 18 Page 19 Page 20 Page 21

Bag and Compact Filters,


Class F5 to F9
Metal Panels Media Rolls Media Rolls Fan Coil Filters
EcoFlo Cam Glass Media Synthetic Media Rolls Fan Coil Filter
Page 22 Page 23 Page 24 Page 25

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Primary Bag Filters


Hi-Cap® 30P, 40P, 50P
Page 26

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

17
Pre-Filtration, Class G3 to F5

Pleated Filters

30/30

Advantages
• High mechanical strength • Large media surface
• Fully supported media bonded • Unique radial pleat design
onto a wire support grid • Bonded into case to eliminate
• Rigid, water resistant cardboard air bypass
frame

Application: Primary filter for air conditioning systems.


Type: High performance disposable pleated panel filter.
Case: Rigid water resistant cardboard.
Media: Mixture of cotton and synthetic fibre.
EN 779:2002 efficiency: G4.
ER
TIFICAT Gravimetric efficiency: 92%.
E
C

EN 779:2002 Eurovent 4/5 efficiency: EU4.


IN

W
IE
DI

Recommended final pressure drop: 250 Pa.


VI F
TI
D
DU
ALLY CER

Temperature: 70°C maximum in continuous service.


Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

Filter Air flow/ Media Unit Unit


Dimensions
Reference Type Model classification pressure drop area weight volume Energy
(WxHxD) mm Rating
EN 779:2002 m³/hr/Pa m2 kg m3
049880-927 30/30 Panel 30/30-12122NOM 305x305x50 G4 864/70 0,39 0,24 0,01 F
049880-006 30/30 Panel 30/30-12242NOM 305x610x50 G4 1710/70 0,79 0,40 0,01 F
049880-001 30/30 Panel 30/30-16202NOM 406x508x50 G4 1890/70 0,94 0,44 0,01 F
049880-004 30/30 Panel 30/30-16252NOM 406x635x50 G4 2340/70 1,18 0,55 0,02 F
049880-002 30/30 Panel 30/30-20202NOM 508x508x50 G4 2340/70 1,12 0,55 0,02 F
049880-012 30/30 Panel 30/30-20242NOM 508x610x50 G4 2880/70 1,36 0,66 0,02 F
049880-003 30/30 Panel 30/30-20252NOM 508x635x50 G4 2970/70 1,42 0,70 0,02 F
049880-005 30/30 Panel 30/30-24242NOM 610x610x50 G4 3420/70 1,64 0,78 0,02 F

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
059413-002 30/30 Panel 30/30-12244NOM 305x610x100 G4 2070/90 1,28 0,75 0,02 E
059413-004 30/30 Panel 30/30-16204NOM 406x508x100 G4 2250/90 1,45 0,85 0,02 E
059413-005 30/30 Panel 30/30-16254NOM 406x635x100 G4 2880/90 1,82 1,05 0,04 E
059413-003 30/30 Panel 30/30-20204NOM 508x508x100 G4 2880/90 1,73 1,05 0,04 E
059413-008 30/30 Panel 30/30-20244NOM 508x610x100 G4 3420/90 2,09 1,25 0,04 E
059413-006 30/30 Panel 30/30-20254NOM 508x635x100 G4 3600/90 2,18 1,30 0,04 E
059413-001 30/30 Panel 30/30-24244NOM 610x610x100 G4 4140/90 2,56 1,45 0,04 E
054862-010 30/30 Panel 30/30-12241NOM 305x610x25 G4 1310/65 0,42 0,25 0,01 G
054862-001 30/30 Panel 30/30-16201NOM 406x508x25 G4 1460/65 0,45 0,30 0,01 G
054862-004 30/30 Panel 30/30-16251NOM 406x635x25 G4 1840/65 0,57 0,35 0,01 G
054862-002 30/30 Panel 30/30-20201NOM 508x508x25 G4 1800/65 0,56 0,35 0,01 G
054862-933 30/30 Panel 30/30-20241NOM 508x610x25 G4 2200/65 0,68 0,40 0,01 G
054862-003 30/30 Panel 30/30-20251NOM 508x635x25 G4 2300/65 0,71 0,45 0,01 G
054862-005 30/30 Panel 30/30-24241NOM 610x610x25 G4 2600/65 0,83 0,50 0,01 G
Other dimensions are available on request - All dimensions are nominal.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

18
Pre-Filtration, Class G3 to F5

Camfil Farr Solutions


Pleated Filters

Aeropleat PP

Advantages
• Moisture resistant cardboard • Fully supported media bonded

Pre-Filtration, Class G3 to F5
frame onto a wire support grid
• Comprehensive range of • Bonded into case to eliminate
standard and non standard air by-pass
sizes • Robust construction

Application: Pre filter for comfort air conditioning applications.


Type: Disposable pleated panel filter.
Case: Moisture resistant cardboard.
Media: Mixture of cotton and synthetic fibre.
ER
TIFICAT
Gravimetric efficiency: 92%.
E
C

Bag and Compact Filters,


EN 779:2002 EN 779:2002 efficiency: G4.
IN

D
IE
DI

VI
W
F
DU
ALLY CER
TI

D Eurovent 4/5 efficiency: EU4.

Class F5 to F9
Recommended final pressure drop: 250 Pa.
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

Filter Unit Unit


Dimensions flow/pressure Media
classification EN Airdrop volume Energy
Reference Type Model weight
(WxHxD) mm m³/hr/Pa area m 2 Rating
779:2002 kg m3

H E PA / U L PA F i l t e r s , C l a s s
PP12122NOM Aeropleat PP PP12122NOM 305x305x50 G4 820/70 0,26 0,20 0,01 G
PP12242NOM Aeropleat PP PP12242NOM 305x610x50 G4 1620/70 0,53 0,35 0,01 G

H10 to U17
PP16202NOM Aeropleat PP PP16202NOM 406x508x50 G4 1830/70 0,63 0,40 0,01 G
PP16252NOM Aeropleat PP PP16252NOM 406x635x50 G4 2300/70 0,79 0,50 0,02 G
PP20202NOM Aeropleat PP PP20202NOM 508x508x50 G4 2290/70 0,75 0,50 0,02 G
PP20242NOM Aeropleat PP PP20242NOM 508x610x50 G4 2750/70 0,91 0,55 0,02 G
PP20252NOM Aeropleat PP PP20252NOM 508x635x50 G4 2880/70 0,95 0,60 0,02 G
PP24242NOM Aeropleat PP PP24242NOM 610x610x50 G4 3240/70 1,10 0,65 0,02 G

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

PP12244NOM Aeropleat PP PP12244NOM 305x610x100 G4 1640/55 0,85 0,65 0,02 G


PP16204NOM Aeropleat PP PP16204NOM 406x508x100 G4 1830/55 0,96 0,75 0,02 G
PP16254NOM Aeropleat PP PP16254NOM 406x635x100 G4 2300/55 1,20 0,90 0,04 G
PP20204NOM Aeropleat PP PP20204NOM 508x508x100 G4 2290/55 1,15 0,90 0,04 G
PP20244NOM Aeropleat PP PP20244NOM 508x610x100 G4 2750/55 1,38 1,05 0,04 G
PP20254NOM Aeropleat PP PP20254NOM 508x635x100 G4 2880/55 1,44 1,10 0,04 G
PP24244NOM Aeropleat PP PP24244NOM 610x610x100 G4 3240/55 1,70 1,20 0,04 G
PP12241NOM Aeropleat PP PP12241NOM 305x610x25 G4 1310/75 0,28 0,25 0,01 G
PP16201NOM Aeropleat PP PP16201NOM 406x508x25 G4 1460/75 0,31 0,25 0,01 G
Filter Frames and Housings

PP16251NOM Aeropleat PP PP16251NOM 406x635x25 G4 1840/75 0,39 0,30 0,01 G


PP20201NOM Aeropleat PP PP20201NOM 508x508x25 G4 1800/75 0,38 0,30 0,01 G
PP20241NOM Aeropleat PP PP20241NOM 508x610x25 G4 2200/75 0,46 0,35 0,01 G
PP20251NOM Aeropleat PP PP20251NOM 508x635x25 G4 2300/75 0,48 0,40 0,01 G
PP24241NOM Aeropleat PP PP24241NOM 610x610x25 G4 2600/75 0,55 0,45 0,01 G
Other sizes are available on request - All dimensions are nominal.
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

19
Pre-Filtration, Class G3 to F5

Panel Filters

Camglass GP

Advantages
• Robust construction • Moisture resistant cardboard
• Comprehensive range of frame
standard and non standard • Gradual density media to
sizes improve dust holding capacity

Application: Pre filter for comfort air conditioning applications.


Type: Disposable panel filter.
Case: Moisture resistant cardboard.
Media: Glass fibre.
EN 779:2002 efficiency: G2, G3.
Gravimetric efficiency: 75% - 85%.
Eurovent 4/5 efficiency: EU2, EU3.
Recommended final pressure drop: 250 Pa.
ER
TIFICAT
Temperature: 70°C maximum in continuous service.
E
C

EN 779:2002 Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
IN

D
IE

W
DI

VI F
DU
ALLY CER
TI

D FC Housings.

Filter Air flow / Unit Unit


Dimensions Media pressure
Reference Type Model classification 2 drop volume weight
(WxHxD) mm area m
EN779:2002 m 3 /hr/Pa m3 kg
GP12242NOM Camglass GP GP12242NOM 305x610x50 G3 0.19 1200/50 0.01 0.20
GP15152NOM Camglass GP GP15152NOM 381x381x50 G3 0.15 990/50 0.01 0.15
GP15202NOM Camglass GP GP15202NOM 381x508x50 G3 0.19 1315/50 0.01 0.20
GP16202NOM Camglass GP GP16202NOM 406x508x50 G3 0.21 1400/50 0.01 0.20
GP16252NOM Camglass GP GP16252NOM 406x635x50 G3 0.26 1750/50 0.02 0.25
GP18182NOM Camglass GP GP18182NOM 457x457x50 G3 0.21 1400/50 0.02 0.20
GP20202NOM Camglass GP GP20202NOM 508x508x50 G3 0.26 1750/50 0.02 0.25
GP20242NOM Camglass GP GP20242NOM 508x610x50 G3 0.31 1460/50 0.02 0.30
GP20252NOM Camglass GP GP20252NOM 508x635x50 G3 0.32 2100/50 0.02 0.35

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
GP24242NOM Camglass GP GP24242NOM 610x610x50 G3 0.37 2400/50 0.02 0.40
GP12241NOM Camglass GP GP12241NOM 305x610x25 G2 0.19 1200/45 0.01 0.20
GP15151NOM Camglass GP GP15151NOM 381x381x25 G2 0.15 990/45 0.01 0.15
GP15201NOM Camglass GP GP15201NOM 381x508x25 G2 0.19 1315/45 0.01 0.20
GP16201NOM Camglass GP GP16201NOM 406x508x25 G2 0.21 1400/45 0.01 0.20
GP16251NOM Camglass GP GP16251NOM 406x635x25 G2 0.26 1750/45 0.01 0.25
GP18181NOM Camglass GP GP18181NOM 457x457x25 G2 0.21 1400/45 0.01 0.20
GP20201NOM Camglass GP GP20201NOM 508x508x25 G2 0.26 1750/45 0.01 0.25
GP20241NOM Camglass GP GP20241NOM 508x610x25 G2 0.31 1460/45 0.01 0.30
GP20251NOM Camglass GP GP20251NOM 508x635x25 G2 0.32 2100/45 0.01 0.35
GP24241NOM Camglass GP GP24241NOM 610x610x25 G2 0.37 2400/45 0.01 0.40
Other sizes are available on request. All dimensions are nominal.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

20
Pre-Filtration, Class G3 to F5

Camfil Farr Solutions


Pad Filters

Pad Holding Frame

Advantages
• Robust construction • Retaining wire for media pad

Pre-Filtration, Class G3 to F5
• Replaceable filter media • Suitable for commercial and
• Support mesh downstream industrial applications

Application: Pre filtration in air conditioning or industrial processing systems.


Type: Coarse grade filter.
Frame: Standard galvanised mild steel.
Media: Synthetic / glass fibre.
EN 779:2002 efficiency: G2, G3, G4.
Arrestance efficiency: 65% - 90%.
Eurovent 4/5 efficiency: EU2, EU3, EU4.

Bag and Compact Filters,


TIFICAT
ER
Temperature: 80°C maximum in continuous service.
E
C

EN 779:2002
Humidity: 100% RH.
IN

D
IE
DI

VI F

W
TI

Class F5 to F9
DU
ALLY CER

D Optional: Alternative frame materials available on request.

Filter Unit Unit


Dimensions Air flow/pressure Media
Reference Type Model classification EN weight volume
(WxHxD) mm drop m³/hr/Pa area m 2
779:2002 kg m3
AMZ24242 NOM PHF-2S 2" POLY 597x597x45 G3 / G4 3240/109 0,36 1,2 0,016
AMZ20242 NOM PHF-2S 2" POLY 495x597x45 G3 / G4 2700/109 0,30 1,0 0,013

H E PA / U L PA F i l t e r s , C l a s s
AMZ12242 NOM PHF-2S 2" POLY 292x597x45 G3 / G4 1620/109 0,18 0,6 0,007
AMZ24241 NOM PHF-1S T15-350 597x597x25 G3 / G4 1924/25 0,36 1,0 0,007

H10 to U17
AMZ20241 NOM PHF-1S T15-350 495x597x25 G3 / G4 1595/25 0,30 0,9 0,005
AMZ12241 NOM PHF-1S T15-350 292x597x25 G3 / G4 941/25 0,18 0,6 0,003
AMZ24242 NOM PHF-2G 2" GLASS 597x597x45 G3 3240/60 0,36 1,2 0,016
AMZ20242 NOM PHF-2G 2" GLASS 495x597x45 G3 2700/60 0,30 1,0 0,013
AMZ12242 NOM PHF-2G 2" GLASS 292x597x45 G3 1620/60 0,18 0,6 0,007
AMZ24241 NOM PHF-1G 1" GLASS 597x597x25 G2 3240/50 0,36 1,0 0,007

Carbon and Chemical Filters


AMZ20241 NOM PHF-1G 1" GLASS 495x597x25 G2 2700/50 0,30 0,9 0,005
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

AMZ12241 NOM PHF-1G 1" GLASS 292x597x25 G2 1620/50 0,18 0,6 0,003
Other sizes available on request - Alternative constructions also available.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

21
Pre-Filtration, Class G3 to F5

Metal Panels

EcoFlo

Advantages
• Totally washable • High mechanical strength
• Low pressure drop • Suitable for high air flow
• Support mesh on both sides conditions

Application: Kitchen extract systems, Pre filtration within air conditioning systems.
Type: Grease elimination or coarse dust removal.
Frame: Galvanised Mild Steel.
Media: Knitted or multilayer pad.
EN 779:2002 efficiency: G2, G3.
TIFICAT
ER
Arrestance efficiency: 65% - 80%.
E
C

EN 779:2002
Eurovent 4/5 efficiency: EU2, EU3.
IN

D
IE
DI

VI
W
F
DU TI
ALLY CER
D Temperature: 100°C maximum in continuous service.
Humidity: 100% RH.
Accessories: Handles and drain holes.
Optional: Alternate materials available on request e.g. Stainless Steel.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

Unit Unit
Dimensions Filter classification Air flow/pressure drop Media volume
Reference Type Model weight
WxHxD (mm) EN 779:2002 (m³/hr/Pa) area (m 2 ) (kg) (m 3 )
GFP12122NOM EcoFlo GFP12122NOM 292x292x45 G2 810/30 0,09 1,2 0,004
GFP12242NOM EcoFlo GFP12242NOM 292x596x45 G2 1620/30 0,18 2,3 0,005
GFP20202NOM EcoFlo GFP20202NOM 495x495x45 G2 2250/30 0,25 3,4 0,011
GFP20242NOM EcoFlo GFP20242NOM 495x596x45 G2 2700/30 0,30 4,0 0,013
GFP24242NOM EcoFlo GFP24242NOM 596x596x45 G2 3240/30 0,36 4,5 0,016
MMP12122NOM EcoFlo MMP12122NOM 292x292x45 G3 810/40 0,09 1,2 0,004
MMP12242NOM EcoFlo MMP12242NOM 292x596x45 G3 1620/40 0,18 2,3 0,005
MMP20202NOM EcoFlo MMP20202NOM 495x495x45 G3 2250/40 0,25 3,4 0,011

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
MMP20242NOM EcoFlo MMP20242NOM 495x596x45 G3 2700/40 0,30 4,0 0,013
MMP24242NOM EcoFlo MMP24242NOM 596x596x45 G3 3240/40 0,36 4,5 0,016
Other dimensions available on request - Alternative constructions also available.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

22
Pre-Filtration, Class G3 to F5

Camfil Farr Solutions


Media Rolls

Cam Glass Media

Advantages
• Continous filament glass fibres, • Full depth particle collection

Pre-Filtration, Class G3 to F5
resin bonded • Economical
• Smooth airflow through booths

Application: For use as a pre filter in air conditioning, and spraybooth extract systems.
Media: Glass Fibre.
TIFICAT
ER
EN 779:2002 efficiency: G2 / G3.
E
C

EN 779:2002
Arrestance efficiency: 75% - 85%.
IN

D
IE
DI

VI F
DU TI
ALLY CER

Eurovent 4/5 efficiency: EU2 / EU3.


Temperature: 120°C maximum in continuous service.
Humidity: 100% RH.

Bag and Compact Filters,


Class F5 to F9
Media Velocity/pressure drop m/ Dust Unit
Dimensions Filter classification EN
Reference Type Model 2 holding g/
(meters) 779:2002 area m s/Pa m² volume m3

PR5071020 50 mm PR 50 0.710 x 20 G2 14.20 1.8 / 30 600 0.71


PR5071040 50 mm PR 50 0.710 x 40 G2 28.40 1.8 / 30 600 1.42
PR50120 50 mm PR 50 1.0 x 20 G2 20.00 1.8 / 30 600 1.00
PR50140 50 mm PR 50 1.0 x 40 G2 40.00 1.8 / 30 600 2.00
PR50150020 50 mm PR 50 1.5 x 20 G2 30.00 1.8 / 30 600 1.5

H E PA / U L PA F i l t e r s , C l a s s
PR50150040 50 mm PR 50 1.5 x 40 G2 60.00 1.8 / 30 600 3.00
PR50182920 50 mm PR 50 1.829 x 20 G2 36.58 1.8 / 30 600 1.829

H10 to U17
PR50220 50 mm PR 50 2.0 x 20 G2 40.00 1.8 / 30 600 2.00
PR50230 50 mm PR 50 2.0 x 30 G2 60.00 1.8 / 30 600 3.00
PR7571040 75 mm PR 75 0.710 x 40 G2 28.40 1.8 / 35 750 2.13
PR10076220 100 mm PR 100 0.762 x 20 G2 15.24 1.8 / 40 900 1.524
PR100120 100 mm PR 100 1.0 x 20 G2 20.00 1.8 / 40 900 2.00
PR100140 100 mm PR 100 1.0 x 40 G2 40.00 1.8 / 40 900 4.00

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

PR100152420 100 mm PR 100 1.524 x 20 G2 30.48 1.8 / 40 900 3.048


PR100152440 100 mm PR 100 1.524 x 40 G2 60.96 1.8 / 40 900 6.096
PR100182920 100 mm PR 100 1.829 x 20 G2 36.58 1.8 / 40 900 3.658
GR5061040 50 mm GR50 0.610x40 G3 24.4 1.8 / 35 700 1.25
Other sizes and cut pads available on request.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

23
Pre-Filtration, Class G3 to F5

Media Rolls

Synthetic Media Rolls

Advantages
• Smooth airflow through booths • Progressively built up thermal
• Non toxic bonded polyester fibre

Application: For use as a pre filter in air conditioning, and spraybooth ventilation.
Flammability: (DIN 53438) self extinguishing.
Media: Synthetic.
EN 779:2002 efficiency: G2, G3, G4.
Arrestance efficiency: 65% - 92%.
Eurovent 4/5 efficiency: EU2, EU3, EU4.
ER
TIFICAT Temperature: 80°C - 100°C maximum in continuous service.
E
C

EN 779:2002 Humidity: 100% RH.


IN

D
IE
DI

VI F
DU TI
ALLY CER

Filter Velocity / Unit Dust


Dimensions
Reference Type Model classification Media area m 2 pressure drop volume holding g/ Pack
(metres) qty
EN779:2002 m/s/Pa m3 m²
T15150SI220 Roll T15-150 2.05 x 20 G2 41 1.5 / 15 0.53 410 1
T15150SI120 Roll T15-150 1.0 x 20 G2 20 1.5 / 15 0.26 410 1
PST290SI220 Roll PST 290 2.05 x 20 G4 41 1.10 / 41 0.82 350 1
PST290SI120 Roll PST 290 1.0 x 20 G4 20 1.10 / 41 0.40 350 1
PST290SI76020 Roll PST 290 0.76 x 20 G4 15 1.10 / 41 0.30 350 1
T15350SI220 Roll T15-350 2.05 x 20 G4 41 1.5 / 25 0.62 678 1
T15500SI220 Roll T15-500 2.05 x 20 G4 41 1.5 / 35 0.08 540 1
POLY220 Roll POLY 50 2.05 x 20 G3 41 1.5 / 45 2.05 550 1
POLYS210 Roll POLY SOFT 50 2.0 x 10 G3 20 1.5 / 52 1.00 673 1
POLYS220 Roll POLY SOFT 50 2.0 x 20 G3 40 1.5 / 52 2.00 673 1
HC80150 Roll HC - 80 1.0 x 50 G2 50 1.5 / 12 0.50 360 1
Other sizes and cut pads available on request.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

24
Pre-Filtration, Class G3 to F5

Camfil Farr Solutions


Fan Coil Filters

Fan Coil Filter

Advantages
• Available in a wide variety of • Low pressure drop

Pre-Filtration, Class G3 to F5
sizes • Light and robust
• Economical

Application: Prevention of dust and dirt build up on heating/cooling coils within ventilation
systems.
Type: Coarse dust removal.
Frame: Metal with downstream support.
Media: Synthetic.
EN 779:2002 efficiency: G2.
Arrestance efficiency: 65%.

Bag and Compact Filters,


Eurovent 4/5 efficiency: EU2.
Temperature: 70°C maximum in continuous service.

Class F5 to F9
Humidity: 100% RH.
TIFICAT
ER
E
C

EN 779:2002
IN

W
IE
DI

VI F
TI
D
DU
ALLY CER

Filter classification EN
Reference Type Model Dimensions (WxHxD) mm 779:2002
CircaSyn (size mm) T15-150 pad CircaSyn as required G2

H E PA / U L PA F i l t e r s , C l a s s
CircaFoam (size mm) 20PPI foam CircaFoam as required G2
Alternative filter materials also available - Other dimensions available on request - Alternative constructions also available.

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

25
Pre-Filtration, Class G3 to F5

Primary Bag Filters

Hi-Cap ® 30P, 40P, 50P

Advantages
• Rigid self supporting pockets • Welded pocket construction
• Robust metal header frame • High mechanical strength

Application: Comfort air conditioning applications, pre filter applications.


Type: Multi pocket bag filter.
Case: Galvanised steel.
Media: Synthetic fibres.
EN 779:2002 efficiency: G3, G4, F5.
Eurovent 4/5 efficiency: EU3, EU4, EU5
Recommended final pressure drop: 250 Pa.
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
ER
TIFICAT
FC Housings.
E
C

EN 779:2002
IN

D
IE
DI

VI F
DU TI
ALLY CER
W D

Number Media Air flow /


Filter Unit Unit
Dimensions pressure Energy
Reference Type Model classification of area volume weight
(WxHxD) mm EN 779:2002 pockets m2 drop Pa m3/hr/ Rating
m3 kg

2415630P25* Hi-Cap 30P 24/15/6/30P/25* 592x592x380 G3 6 2.7 3400/35 0.05 2.2 F


2015530P25* Hi-Cap 30P 20/15/5/30P/25* 490x592x380 G3 5 2.3 2800/35 0.05 2.0 F
1215330P25* Hi-Cap 30P 12/15/3/30P/25* 287x592x380 G3 3 1.4 1700/35 0.03 1.4 F
2420630P25* Hi-Cap 30P 24/20/6/30P/25* 592x592x500 G3 6 3.6 3400/30 0.05 2.7 F
2020530P25* Hi-Cap 30P 20/20/5/30P/25* 490x592x500 G3 5 3.0 2800/30 0.05 2.5 F
1220330P25* Hi-Cap 30P 12/20/3/30P/25* 287x592x500 G3 3 1.8 1700/30 0.03 1.6 F
2415640P25* Hi-Cap 40P 24/15/6/40P/25* 592x592x380 G4 6 2.7 3400/40 0.05 2.2 F

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
2015540P25* Hi-Cap 40P 20/15/5/40P/25* 490x592x380 G4 5 2.3 2800/40 0.05 2.0 F
1215340P25* Hi-Cap 40P 12/15/3/40P/25* 287x592x380 G4 3 1.4 1700/40 0.03 1.4 F
2420640P25* Hi-Cap 40P 24/20/6/40P/25* 592x592x500 G4 6 3.6 3400/35 0.05 2.7 F
2020540P25* Hi-Cap 40P 20/20/5/40P/25* 490x592x500 G4 5 3.0 2800/35 0.05 2.5 F
1220340P25* Hi-Cap 40P 12/20/3/40P/25* 287x592x500 G4 3 1.8 1700/35 0.03 1.6 F
2415650P25* Hi-Cap 50P 24/15/6/50P/25* 592x592x380 F5 6 2.7 3400/80 0.05 2.4 F
2015550P25* Hi-Cap 50P 20/15/5/50P/25* 490x592x380 F5 5 2.3 2800/80 0.05 2.2 F
1215350P25* Hi-Cap 50P 12/15/3/50P/25* 287x592x380 F5 3 1.4 1700/80 0.03 1.6 F
2420650P25* Hi-Cap 50P 24/20/6/50P/25* 592x592x500 F5 6 3.6 3400/75 0.05 3.0 F
2020550P25* Hi-Cap 50P 20/20/5/50P/25* 490x592x500 F5 5 3.0 2800/75 0.05 2.8 F
1220350P25* Hi-Cap 50P 12/20/3/50P/25* 287x592x500 F5 3 1.8 1700/75 0.03 1.8 F
Other sizes are available on request - 25* denotes a 25 mm header frame, if a 20 mm header frame is required please specify 20*.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

26
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Summary Bag and Compact Filters, Class F5 to F9

Pre-Filtration, Class G3 to F5
Bag Filters Glass Fibre Bag Filters Glass Fibre Bag Filters Glass Fibre Bag Filters Glass Fibre
® ® ®
Hi-Flo M-Series Hi-Flo P, PL-Series Hi-Flo U-Series Hi-Flo® A-Series
Page 29 Page 30 Page 31 Page 32

Bag and Compact Filters,


Class F5 to F9
Bag Filters Glass Fibre Bag Filters Synthetic Bag Filters Synthetic Bag Filters Synthetic
®
Hi-Flo T-Series Media Media Media
Page 33 S-Flo W P Series S-Flo W U Series S-Flo W A Series

H E PA / U L PA F i l t e r s , C l a s s
Page 34 Page 35 Page 36

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Compact Filter High Efficiency Panel Pleated Compact Filter Pleated Compact Filter
Opakfil Green Ecopleat & Ecopleat MCTA Riga-Flo OpakAir
Page 37 Page 38 Page 39 Page 40

Filter Frames and Housings

Pleated Compact Filter


Airopac®
Page 41
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

27
Bag and Compact Filters, Class F5 to F9

Eurovent Certified Performance

Air filter certification You can count on


us!
Camfil Farr, in conjunction with the main independent test laboratories in
Europe, is committed to bringing you the highest levels of transparency
with regard to the new test protocols for air filters.
The European Committee for Standardisation has recently published a
new standard on "Particulate air filters for general ventilation -
determination of filtration performance". One of the aims of this new
Independent test results
standard is to detail the in-situ performance of an air filter. Our Eurovent certification covers bag filters, compact filters and panel
This new test protocol provides accurate data on the effectiveness of filters in classes F5-F9, tested to EN 779:2002. The initial pressure
your air filters operating under real life conditions. Please always drop must remain within the tolerance levels set out in EN 779:2002.*
specify filters tested in accordance with EN 779:2002. Your Camfil All filters that we officially market in brochures or on our website in
representative is available to explain this standard in detail should you these filter classes are covered by the certification. Each class contains
require it - you can count on us! a range of product groups:
• Same filter media/material (such as fibreglass)
Air filter performance • Same basic design (such as bag filters, compact
filters etc)
At Camfil Farr we are going a step further to ensure the best possible
• Same or lower air speed/net filter area
performance for our customers. The European ventilation industry
• Same filter class: F5, F6, F7, F8, F9
organisation Eurovent, in collaboration with several European air-filter
manufacturers, has developed a certification programme to guarantee • Published data must be available, specifying the
that our products live up to our promises. model, type, filter material, filter class as per EN
779:2002,
The key elements of the programme are that:
• Nominal airflow and initial pressure drop at nominal

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
• Published data must be correct airflow.
• The products must comply with the EN 779:2002 The filters are tested at independent test laboratories - in Sweden, the
standard Technical Research Institute of Sweden, SP, in Borås; in Finland, VTT in
• Filters must be tested by independent laboratories - Espoo. These are the only laboratories in Europe that are accredited to
SP in Sweden and VTT in Finland ISO 17025.
• The test laboratories must be ISO 17025 certified The test laboratories are not told which company’s products they are
• We as manufacturers must be quality certified to ISO testing, but are only given a number that Eurovent assigns to each
9000 or a corresponding standard individual filter.
• Each year, Eurovent selects, at random, four new Tolerance levels for initial pressure drop defined in EN 779:2002:
filters from our range for inspection +(10%+Mt) or +(10Pa+Mt), whichever is highest. Mt = 5Pa (tolerance
Read more on Eurovent’s website: www.eurovent-certification.com level defined in EN 779:2002)

Eurovent’s certification of our fine-dust filters means that you can rest
assured that we live up to the performance requirements and the data TIFICAT
ER
E
C

we print in our official documentation. Our fine-dust filters are tested by


independent laboratories selected by Eurovent and that means security EN 779:2002
for you. Select Camfil air filters with Eurovent certification - its
IN

D
IE
DI

VI F
DU TI
guaranteed! ALLY CER

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

28
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Bag Filters Glass Fibre

Hi-Flo ® M-Series

Advantages
• Rubust construction • Comprehensive range of

Pre-Filtration, Class G3 to F5
• Save energy - optimised design standard sizes
(LCC) • Certified performance
• Controlled media spacing • Large surface area
(CMS)

Application: Air conditioning applications.


Type: Extended surface multi pocket bag filter.
Case: Galvanised steel.
Media: Glass Fibre.
EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8/9 (90-95%).

Bag and Compact Filters,


TIFICAT
ER
Eurovent 4/5 efficiency: EU6, EU7, EU8.
E
C

EN 779:2002
Recommended final pressure drop: 450 Pa (suggested economical change point 250Pa).
IN

Class F5 to F9
IE
DI

VI F
DU TI
ALLY CER
D
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

EFFICIENCY
GUARANTEE

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Filter Unit Unit
Dimensions of Media Air flow/pressure
classification EN Number volume Energy
Reference Type Model weight
(WxHxD) pockets area m 2 drop m 3 /hr/Pa Rating
779:2002 kg m3
535025A1 Hi-Flo M6 592x592x635 F6 12 9.2 3400/65 3.3 0.05 B
535002A1 Hi-Flo N6 490x592x635 F6 10 7.7 2800/64 3.0 0.05 B
535026A1 Hi-Flo O6 287x592x635 F6 6 4.6 1700/65 1.9 0.03 B
535025A2 Hi-Flo M7 592x592x635 F7 12 9.2 3400/85 2.9 0.05 A

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

535002A2 Hi-Flo N7 490x592x635 F7 10 7.7 2800/83 2.5 0.05 A


535026A2 Hi-Flo O7 287x592x635 F7 6 4.6 1700/85 1.7 0.03 A
535025A3 Hi-Flo M9 592x592x635 F8/9 12 9.2 3400/130 2.9 0.05 A
535002A3 Hi-Flo N9 490x592x635 F8/9 10 7.7 2800/128 2.6 0.05 A
535026A3 Hi-Flo O9 287x592x635 F8/9 6 4.6 1700/130 1.8 0.03 A
Other sizes are available on request - *Supplied with a 25mm header frame as standard, 20mm header available on request.
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

29
Bag and Compact Filters, Class F5 to F9

Bag Filters Glass Fibre

Hi-Flo ® P, PL-Series

Advantages
• Large surface area • Comprehensive range of
• Rubust construction standard sizes
• Controlled media spacing • Low pressure drop
(CMS) • Certified performance

Application: Air conditioning applications.


Type: Extended surface multi pocket bag filter.
Case: Galvanised steel.
Media: Glass Fibre.
EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8/9 (90-95%).
TIFICAT
Eurovent 4/5 efficiency: EU6, EU7, EU8.
ER
E
C

EN 779:2002
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
Temperature: 70°C maximum in continuous service.
IN

D
IE
DI

W
VI F
DU TI

D
ALLY CER

Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

EFFICIENCY
GUARANTEE

Filter Unit Unit


Dimensions of Media Air flow/pressure
classification EN Number volume Energy
Reference Type Model weight
(WxHxD) pockets area m 2 drop m 3 /hr/Pa Rating
779:2002 kg m3
535027A1 Hi-Flo P6 592x592x534 F6 10 6.5 3400/70 2.9 0.05 B
535005A1 Hi-Flo Q6 490x592x534 F6 8 5.2 2700/70 2.4 0.05 B
535028A1 Hi-Flo R6 287x592x534 F6 5 3.2 2100/95 1.6 0.03 B
535027A2 Hi-Flo P7 592x592x534 F7 10 6.5 3400/105 2.6 0.05 B

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
535005A2 Hi-Flo Q7 490x592x534 F7 8 5.2 2700/105 2.4 0.05 B
535028A2 Hi-Flo R7 287x592x534 F7 5 3.2 1700/105 1.6 0.03 B
535027A3 Hi-Flo P9 592x592x534 F8 10 6.5 3400/150 2.4 0.05 B
535005A3 Hi-Flo Q9 490x592x534 F8 8 5.2 2700/150 2.4 0.05 B
535028A3 Hi-Flo R9 287x592x534 F8 5 3.2 1700/150 1.6 0.03 B
536004A1 Hi-Flo PL6 592x892x534 F6 10 9.7 5100/70 4.4 0.10 B
536005A1 Hi-Flo QL6 490x892x534 F6 8 7.8 4200/70 4.0 0.11 B
536006A1 Hi-Flo RL6 287x892x534 F6 5 4.8 2550/70 2.6 0.05 B
536004A2 Hi-Flo PL7 592x892x534 F7 10 9.7 5100/110 3.8 0.11 B
536005A2 Hi-Flo QL7 490x892x534 F7 8 7.8 4200/110 3.6 0.11 B
536006A2 Hi-Flo RL7 287x892x534 F7 5 4.8 2550/110 2.2 0.05 B
536004A3 Hi-Flo PL9 592x892x534 F8/9 10 9.7 5100/153 4.1 0.11 B
536005A3 Hi-Flo QL9 490x892x534 F8/9 8 7.8 4200/154 3.7 0.11 B
536006A3 Hi-Flo RL9 287x892x534 F8/9 5 4.8 2550/151 2.5 0.05 B
Other sizes are available on request - *Supplied with a 25mm header as standard. 20mm header available on request.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

30
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Bag Filters Glass Fibre

Hi-Flo ® U-Series

Advantages
• Large surface area • Controlled media spacing

Pre-Filtration, Class G3 to F5
• Comprehensive range of (CMS)
standard sizes • High dust holding capacity
• Rubust construction • Certified performance

Application: Comfort air conditioning applications, pre filter applications.


Type: Multi pocket bag filter.
Case: Galvanised steel.
Media: Glass Fibre.
TIFICAT
ER
EN 779:2002 efficiency: F5 (40-50%), F6 (55-65%), F7 (80-85%), F8 (90-95%).
E
C

EN 779:2002
Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8.

Bag and Compact Filters,


IN

W
IE
DI

VI F
DU TI
ALLY CER
D Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
Temperature: 70°C maximum in continuous service.

Class F5 to F9
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

EFFICIENCY
GUARANTEE

H E PA / U L PA F i l t e r s , C l a s s
Dimensions Filter classification Number of Media Air flow/pressure drop Unit Unit volume Energy
Reference Type Model (WxHxD) EN 779:2002 pockets area m 2 m 3 /hr/Pa weight kg m3 Rating

H10 to U17
*35606060U Hi-Flo *3U-4050/6060/60 592x592x600 F5 8 6.0 3400/50 2.8 0.05 C
*35606038U Hi-Flo *3U-4050/6060/38 592x592x380 F5 8 3.8 2700/75 2.3 0.05 C
*35506060U Hi-Flo *3U-4050/5060/60 490x592x600 F5 6 4.6 2800/55 2.4 0.05 C
*35506038U Hi-Flo *3U-4050/5060/38 490x592x380 F5 6 2.9 2250/80 1.9 0.05 C
*35306060U Hi-Flo *3U-4050/3060/60 287x592x600 F5 4 3.0 1700/50 1.6 0.03 C
*35306038U Hi-Flo *3U-4050/3060/38 287x592x380 F5 4 1.9 1350/75 1.4 0.03 C
*36606060U Hi-Flo *3U-65/6060/60 592x592x600 F6 8 6.0 3400/80 2.8 0.05 B

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

*36606038U Hi-Flo *3U-65/6060/38 592x592x380 F6 8 3.8 2700/95 2.3 0.05 B


*36506060U Hi-Flo *3U-65/5060/60 490x592x600 F6 6 4.6 2600/80 2.4 0.05 B
*36506038U Hi-Flo *3U-65/5060/38 490x592x380 F6 6 2.9 2250/100 1.9 0.05 B
*36306060U Hi-Flo *3U-65/3060/60 287x592x600 F6 4 3.0 1700/80 1.6 0.03 B
*36306038U Hi-Flo *3U-65/3060/38 287x592x380 F6 4 1.9 1350/95 1.4 0.03 B
*37606060U Hi-Flo *3U-85/6060/60 592x592x600 F7 8 6.0 3400/125 2.8 0.05 B
*37606038U Hi-Flo *3U-85/6060/38 592x592x380 F7 8 3.8 2700/150 2.3 0.05 B
*37506060U Hi-Flo *3U-85/5060/60 490x592x600 F7 6 4.6 2600/125 2.4 0.05 B
*37506038U Hi-Flo *3U-85/5060/38 490x592x380 F7 6 2.9 2250/165 1.9 0.05 B
Filter Frames and Housings

*37306060U Hi-Flo *3U-85/3060/60 287x592x600 F7 4 3.0 1700/125 1.6 0.03 B


*37306038U Hi-Flo *3U-85/3060/38 287x592x380 F7 4 1.9 1350/150 1.4 0.03 B
*38606060U Hi-Flo *3U-95/6060/60 592x592x600 F8 8 6.0 3400/185 2.8 0.05 B
*38606038U Hi-Flo *3U-95/6060/38 592x592x380 F8 8 3.8 2700/195 2.3 0.05 B
*38506060U Hi-Flo *3U-95/5060/60 490x592x600 F8 6 4.6 2600/185 2.4 0.05 B
*38506038U Hi-Flo *3U-95/5060/38 490x592x380 F8 6 2.9 2250/200 1.9 0.05 B
*38306060U Hi-Flo *3U-95/3060/60 287x592x600 F8 4 3.0 1700/185 1.6 0.03 B
*38306038U Hi-Flo *3U-95/3060/38 287x592x380 F8 4 1.9 1350/195 1.4 0.03 B
Other sizes are available on request - *3 denotes a 25mm header frame, if a 20mm header frame is required please specify *2.
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

31
Bag and Compact Filters, Class F5 to F9

Bag Filters Glass Fibre

Hi-Flo ® A-Series

Advantages
• High dust holding capacity • Robust construction
• Controlled media spacing • Comprehensive range of
(CMS) standard sizes

Application: Comfort air conditioning applications, pre filter applications.


Type: Multi pocket bag filter.
Case: Galvanised steel.
Media: Glass Fibre.
EN 779:2002 efficiency: F5 (40-50%), F6 (55-65%), F7 (80-85%), F8 (90-95%).
Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8.
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
ER
TIFICAT Temperature: 70°C maximum in continuous service.
E
C

EN 779:2002 Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
IN

W
IE
DI

VI

FC Housings.
F

D
DU TI
ALLY CER

EFFICIENCY
GUARANTEE

Dimensions Filter classification Number of Media Air flow/pressure drop Unit Unit volume Energy
Reference Type Model
(WxHxD) EN 779:2002 pockets surface m 2 m 3 /hr/Pa weight kg m3 Rating

*35606060A Hi-Flo *3A-4050/6060/60 592x592x600 F5 6 4.7 3400/70 2.4 0.05 D


*35606038A Hi-Flo *3A-4050/6060/38 592x592x380 F5 6 2.9 2700/70 2.0 0.05 D
*35506060A Hi-Flo *3A-4050/5060/60 490x592x600 F5 5 3.9 2800/70 2.1 0.05 D
*35506038A Hi-Flo *3A-4050/5060/38 490x592x380 F5 5 2.4 2250/75 1.8 0.05 D
*35306060A Hi-Flo *3A-4050/3060/60 287x592x600 F5 3 2.3 1700/70 1.5 0.03 D

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
*35306038A Hi-Flo *3A-4050/3060/38 287x592x380 F5 3 1.5 1350/70 1.3 0.03 D
*36606060A Hi-Flo *3A-65/6060/60 592x592x600 F6 6 4.7 3400/70 2.4 0.05 B
*36606038A Hi-Flo *3A-65/6060/38 592x592x380 F6 6 2.9 2700/95 2.0 0.05 B
*36506060A Hi-Flo *3A-65/5060/60 490x592x600 F6 5 3.9 2800/75 2.1 0.05 B
*36506038A Hi-Flo *3A-65/5060/38 490x592x380 F6 5 2.4 2250/100 1.8 0.05 B
*36306060A Hi-Flo *3A-65/3060/60 287x592x600 F6 3 2.3 1700/70 1.5 0.03 B
*36306038A Hi-Flo *3A-65/3060/38 287x592x380 F6 3 1.5 1350/95 1.3 0.03 B
*37606060A Hi-Flo *3A-85/6060/60 592x592x600 F7 6 4.7 2700/105 2.4 0.05 C
*37606038A Hi-Flo *3A-85/6060/38 592x592x380 F7 6 2.9 2150/135 2.0 0.05 C
*37506060A Hi-Flo *3A-85/5060/60 490x592x600 F7 5 3.9 2250/100 2.1 0.05 C
*37506038A Hi-Flo *3A-85/5060/38 490x592x380 F7 5 2.4 1800/130 1.8 0.05 C
*37306060A Hi-Flo *3A-85/3060/60 287x592x600 F7 3 2.3 1350/115 1.5 0.03 C
*37306038A Hi-Flo *3A-85/3060/38 287x592x380 F7 3 1.5 1100/145 1.3 0.03 C
*38606060A Hi-Flo *3A-95/6060/60 592x592x600 F8 6 4.7 2700/175 2.4 0.05 C
*38606038A Hi-Flo *3A-95/6060/38 592x592x380 F8 6 2.9 2150/220 2.0 0.05 C
*38506060A Hi-Flo *3A-95/5060/60 490x592x600 F8 5 3.9 2250/180 2.1 0.05 C
*38506038A Hi-Flo *3A-95/5060/38 490x592x380 F8 5 2.4 1800/225 1.8 0.05 C
*38306060A Hi-Flo *3A-95/3060/60 287x592x600 F8 3 2.3 1350/170 1.5 0.03 C
*38306038A Hi-Flo *3A-95/3060/38 287x592x380 F8 3 1.5 1100/215 1.3 0.03 C
Other sizes are available on request - *3 denotes a 25mm header frame, if a 20mm header frame is required please specify *2.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

32
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Bag Filters Glass Fibre

Hi-Flo ® T-Series

Advantages
• Large surface area • Controlled media spacing

Pre-Filtration, Class G3 to F5
• Ultra compact (CMS)
• Low pressure drop • High dust holding capacity

Application: Air conditioning applications.


Type: Compact multi-pocket bag filter.
Case: Galvanised steel.
Media: Glass Fibre.
EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8/9 (90-95%).
Eurovent 4/5 efficiency: EU6, EU7, EU8.
TIFICAT Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).

Bag and Compact Filters,


ER
E
C

EN 779:2002 Temperature: 70°C maximum in continuous service.


IN

D
IE

W
DI

VI

Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
F
DU TI

Class F5 to F9
ALLY CER

FC Housings.

EFFICIENCY
GUARANTEE

Dimensions Filter classification Number of Media Air flow/pressure Unit Unit


Reference Type Model

H E PA / U L PA F i l t e r s , C l a s s
(WxHxD) EN 779:2002 pockets area m 2 drop m 3 /hr/Pa weight kg volume m 3
535023A1 Hi-Flo *TM6 592x592x380 F6 12 5.5 3400/90 2.3 0.05

H10 to U17
535024A1 Hi-Flo TN6 490x592x380 F6 10 4.5 2800/90 2.2 0.05
535022A1 Hi-Flo TO6 287x592x380 F6 6 2.7 1700/90 1.4 0.03
535023A2 Hi-Flo TM7 592x592x380 F7 12 5.5 3400/130 2.3 0.05
535024A2 Hi-Flo TN7 490x592x380 F7 10 4.5 2800/130 2.1 0.05
535022A2 Hi-Flo TO7 287x592x380 F7 6 2.7 1700/130 1.4 0.03
535023A3 Hi-Flo TM9 592x592x380 F8/9 12 5.5 3400/205 2.3 0.05

Carbon and Chemical Filters


535024A3 Hi-Flo TN9 490x592x380 F8/9 10 4.5 2800/205 2.0 0.05
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

535022A3 Hi-Flo TO9 287x592x380 F8/9 6 2.7 1700/205 1.4 0.03


Other sizes are available on request - *Supplied with a 25mm header frame as standard. 20mm header available on request.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

33
Bag and Compact Filters, Class F5 to F9

Bag Filters Synthetic Media

S-Flo W P Series

Advantages
• Extended surface multi-pocket • High efficiency
filter • Large surface area
• Comprehensive range of • Controlled media spacing
standard sizes (CMS)
• Unique pocket design

Application: Air conditioning applications.


Type: Extended surface multi pocket bag filter.
Case: Galvanised steel.
Media: Synthetic Fibres.
EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8 (90-95%).
ER
TIFICAT Eurovent 4/5 efficiency: EU6, EU7, EU8.
E
C

EN 779:2002 Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
IN

D
IE
DI

VI

Temperature: 70°C maximum in continuous service.


F
TI
W
DU

D
ALLY CER

Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

Filter Air flow/ Unit


Dimensions of Media weight Unit
classification EN pressure drop Number Energy
Reference Type Model 2
(WxHxD) mm 779:2002 m³/hr/Pa pockets area m kg volume m3 Rating

*36606053PW S-Flo-W *P6 592x592x534 F6 3400/45 10 6,5 2,7 0,05 D


*36506053PW S-Flo-W *Q6 490x592x534 F6 2800/45 8 5,2 2,4 0,05 D
*36306053PW S-Flo-W *R6 287x592x534 F6 1700/45 5 3,2 1,6 0,03 D
*37606053PW S-Flo-W *P7 592x592x534 F7 3400/75 10 6,5 2,7 0,05 E

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
*37506053PW S-Flo-W *Q7 490x592x534 F7 2800/75 8 5,2 2,4 0,05 E
*37306053PW S-Flo-W *R7 287x592x534 F7 1700/75 5 3,2 1,6 0,03 E
*38606053PW S-Flo-W *P8 592x592x534 F8 3400/95 10 6,5 2,7 0,05 E
*38506053PW S-Flo-W *Q8 490x592x534 F8 2800/95 8 5,2 2,4 0,05 E
*38306053PW S-Flo-W *R8 287x592x534 F8 1700/95 5 3,2 1,6 0,03 E
Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specify *2.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

34
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Bag Filters Synthetic Media

S-Flo W U Series

Advantages
• Multi-pocket bag filter • Unique pocket design

Pre-Filtration, Class G3 to F5
• Comprehensive range of • Large surface area
standard sizes • Controlled media spacing
• Robust metal header frame (CMS)

Application: Air conditioning applications.


Type: Extended surface multi pocket bag filter.
Case: Galvanised steel.
Media: Synthetic Fibres.
EN 779:2002 efficiency: F6 (55-65%), F7 (80-85%), F8 (90-95%).
Eurovent 4/5 efficiency: EU6, EU7, EU8.

Bag and Compact Filters,


ER
TIFICAT
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
E
C

EN 779:2002
Temperature: 70°C maximum in continuous service.
IN

Class F5 to F9
IE
DI

VI F
TI
W
DU
ALLY CER
D Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
FC Housings.

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Dimensions Filter classification Air flow/pressure drop Number of Media Unit weight Unit volume Energy
Reference Type Model
(WxHxD) mm EN 779:2002 m³/hr/Pa pockets area m 2 kg m3 Rating

*35606060UW S-Flo-W *UF5 592x592x600 F5 3400/46 8 6 2,8 0,05 F


*35606038UW S-Flo-W *UF5/38 592x592x380 F5 2550/33 8 3,8 2,3 0,05 F
*35506060UW S-Flo-W *UG5 490x592x600 F5 2800/46 6 4,6 2,4 0,05 F
*35506038UW S-Flo-W *UG5/38 490x592x380 F5 2100/33 6 2,9 1,9 0,05 F
*35306060UW S-Flo-W *UH5 287x592x600 F5 1700/46 4 3 1,6 0,03 F

Carbon and Chemical Filters


*35306038UW S-Flo-W *UH5/38 287x592x380 F5 1275/33 4 1,9 1,4 0,03 F
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

*36606060UW S-Flo-W *UF6 592x592x600 F6 3400/50 8 6 2,8 0,05 E


*36606038UW S-Flo-W *UF6/38 592x592x380 F6 2550/37 8 3,8 2,3 0,05 E
*36506060UW S-Flo-W *UG6 490x592x600 F6 2800/50 6 4,6 2,4 0,05 E
*36506038UW S-Flo-W *UG6/38 490x592x380 F6 2100/37 6 2,9 1,9 0,05 E
*36306060UW S-Flo-W *UH6 287x592x600 F6 1700/50 4 3 1,6 0,03 E
*36306038UW S-Flo-W *UH6/38 287x592x380 F6 1275/37 4 1,9 1,4 0,03 E
*37606060UW S-Flo-W *UF7 592x592x600 F7 3400/60 8 6 2,8 0,05 E
*37606038UW S-Flo-W *UF7/38 592x592x380 F7 2550/61 8 3,8 2,3 0,05 E
*37506060UW S-Flo-W *UG7 490x592x600 F7 2800/60 6 4,6 2,4 0,05 E
Filter Frames and Housings

*37506038UW S-Flo-W *UG7/38 490x592x380 F7 2100/61 6 2,9 1,9 0,05 E


*37306060UW S-Flo-W *UH7 287x592x600 F7 1700/60 4 3 1,6 0,03 E
*37306038UW S-Flo-W *UH7/38 287x592x380 F7 1275/61 4 1,9 1,4 0,03 E
*38606060UW S-Flo-W *UF8 592x592x600 F8 3400/80 8 6 2,8 0,05 E
*38606038UW S-Flo-W *UF8/38 592x592x380 F8 3400/140 8 3,8 2,3 0,05 E
*38506060UW S-Flo-W *UG8 490x592x600 F8 2800/80 6 4,6 2,4 0,05 E
*38506038UW S-Flo-W *UG8/38 490x592x380 F8 2800/140 6 2,9 1,9 0,05 E
*38306060UW S-Flo-W *UH8 287x592x600 F8 1700/80 4 3 1,6 0,03 E
*38306038UW S-Flo-W *UH8/38 287x592x380 F8 1700/140 4 1,9 1,4 0,03 E
Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specify *2.
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

35
Bag and Compact Filters, Class F5 to F9

Bag Filters Synthetic Media

S-Flo W A Series

Advantages
• Multi-pocket bag filter • Unique pocket design
• Comprehensive range of • Available in a range of
standard sizes efficiencies
• Robust metal header frame

Application: Comfort air conditioning applications, pre filter applications.


Type: Multi pocket bag filter.
Case: Galvanised steel.
Media: Synthetic Fibres.
EN 779:2002 efficiency: F5 (40-50%), F6 (55-65%), F7 (80-85%), F8 (90-95%).
Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8.
TIFICAT
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
ER
E
C

EN 779:2002
Temperature: 70°C maximum in continuous service.
Holding frames: Front and side access housings and frames are available, Type 8, Type L, and
IN

D
IE
DI

VI
W
F
DU TI
ALLY CER
D
FC Housings.

Filter Unit Unit


Dimensions Air flow/pressure Number of Media volume
Reference Type Model classification EN weight
(WxHxD) mm drop m³/hr/Pa pockets area m 2
779:2002 kg m3
*35606060AW S-Flo-W *A5 592x592x600 F5 3400/50 6 4,70 2,40 0,050
*35606038AW S-Flo-W *A5/38 592x592x380 F5 2250/36 6 2,90 2,00 0,050
*35506060AW S-Flo-W *B5 490x592x600 F5 2800/50 5 3,90 2,00 0,050
*35506038AW S-Flo-W *B5/38 490x592x380 F5 2100/36 5 2,40 1,80 0,050
*35306060AW S-Flo-W *C5 287x592x600 F5 1700/51 3 2,30 1,50 0,030
*35306038AW S-Flo-W *C5/38 287x592x380 F5 1275/36 3 1,50 1,30 0,030

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
*36606060AW S-Flo-W *A6 592x592x600 F6 3400/55 6 4,70 2,40 0,050
*36606038AW S-Flo-W *A6/38 592x592x380 F6 2550/40 6 2,90 2,00 0,050
*36506060AW S-Flo-W *B6 490x592x600 F6 2800/55 5 3,90 2,00 0,050
*36506038AW S-Flo-W *B6/38 490x592x380 F6 2100/40 5 2,40 1,80 0,050
*36306060AW S-Flo-W *C6 287x592x600 F6 1700/55 3 2,30 1,50 0,030
*36306038AW S-Flo-W *C6/38 287x592x380 F6 1275/40 3 1,50 1,30 0,030
*37606060AW S-Flo-W *A7 592x592x600 F7 2550/52 6 4,70 2,40 0,050
*37606038AW S-Flo-W *A7/38 592x592x380 F7 2550/80 6 2,90 2,00 0,050
*37506060AW S-Flo-W *B7 490x592x600 F7 2100/52 5 3,90 2,00 0,050
*37506038AW S-Flo-W *B7/38 490x592x380 F7 2100/80 5 2,40 1,80 0,050
*37306060AW S-Flo-W *C78 287x592x600 F7 1275/52 3 2,30 1,50 0,030
*37306038AW S-Flo-W *C7/38 287x592x380 F7 1275/80 3 1,50 1,30 0,030
*38606060AW S-Flo-W *A8 592x592x600 F8 3400/100 6 4,70 2,40 0,050
*38606038AW S-Flo-W *A8/38 592x592x380 F8 3400/195 6 2,90 2,00 0,050
*38506060AW S-Flo-W *B8 490x592x600 F8 2800/100 5 3,90 2,00 0,050
*38506038AW S-Flo-W *B8/38 490x592x380 F8 2800/195 5 2,40 1,80 0,050
*38306060AW S-Flo-W *C8 287x592x600 F8 1700/100 3 2,30 1,50 0,030
*38306038AW S-Flo-W *C8/38 287x592x380 F8 1700/195 3 1,50 1,30 0,030
Other sizes are available on request - *Supplied with a 25mm header frame, if a 20mm header frame is required please specificy *2.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

36
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Compact Filter

Opakfil Green

Advantages
• Less frequent changes • Large surface area

Pre-Filtration, Class G3 to F5
• Long operating life • Certified performance
• Light and robust optimised for LCC

Application: Air conditioning applications and preparatory filtration in clean rooms.


Type: High efficiency, incinerable filter.
Frame: 25mm thick flange, polypropylene and ABS.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
EN 779:2002 efficiency: F6, F7, F8, F9.

Bag and Compact Filters,


ER
TIFICAT Opacimetric efficiency: 65, 85, 95, 98%.
E
C

EN 779:2002 EUROVENT 4/5 efficiency: EU6, EU7, EU8, EU9.

Class F5 to F9
IN

D
IE

Recommended final pressure drop: 450 Pa (suggested economical change point 350 Pa).
DI

W
VI F
DU TI

D
ALLY CER

Temperature: 70°C maximum in continuous service.


Mounting system: Front and side access housing and frames are available, Type 8, Type L
and FC housings.

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
EFFICIENCY
GUARANTEE

Filter Media Air flow/pressure Unit Unit


Dimensions area volume Energy
Reference Type Model classification weight
(WxHxD) mm drop m 3 /h/Pa Rating
EN 779:2002 m2 kg m3

Carbon and Chemical Filters


1511.11.50 OPAKFIL-G -65 3OPGHF-242412-60 592x592x290 F6 19.0 4250/100 5 0.11 B
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1511.21.50 OPAKFIL-G -65 3OPGHF-242012-60 592x490x290 F6 15.0 3400/100 4 0.09 B


1511.51.50 OPAKFIL-G -65 3OPGHF-241212-60 592x287x290 F6 9.0 2125/100 3 0.05 B
1511.12.50 OPAKFIL-G -85 3OPGHF-242412-90 592x592x290 F7 19.0 4250/110 5 0.11 A
1511.22.50 OPAKFIL-G -85 3OPGHF-242012-90 592x490x290 F7 15.0 3400/110 4 0.09 A
1511.52.50 OPAKFIL-G -85 3OPGHF-241212-90 592x287x290 F7 9.0 2125/135 3 0.05 A
1511.13.50 OPAKFIL-G -95 3OPGHF-242412-95 592x592x290 F8 19.0 4250/130 5 0.11 A
1511.23.50 OPAKFIL-G -95 3OPGHF-242012-95 592x490x290 F8 15.0 3400/130 4 0.09 A
1511.53.50 OPAKFIL-G -95 3OPGHF-241212-95 592x287x290 F8 9.0 2125/150 3 0.05 A
Filter Frames and Housings

1511.17.50 OPAKFIL-G-98 3OPGHF-242412-98 592x592x290 F9 19.0 4250/160 5 0.11 B


1511.24.50 OPAKFIL-G-98 3OPGHF-242012-98 592x490x290 F9 15.0 3400/160 4 0.09 B
1511.57.50 OPAKFIL-G-98 3OPGHF-241212-98 592x287x290 F9 9.0 2125/160 3 0.05 B
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

37
Bag and Compact Filters, Class F5 to F9

High Efficiency Panel

Ecopleat & Ecopleat MCTA

Advantages
• Large surface area • Ultra compact
• Savings in operating costs • High dust holding capacity
• 10 times more filtration surface • Less frequent changes

Application: Air conditioning or industrial processing systems and for mini air conditioning
systems, individual modules.
Type: High efficiency compact filter.
Frame: Galvanised steel.
Media: Glass fibre paper.
TIFICAT
Separator: Hot-melt beads.
ER
E
C

EN 779:2002
EN 779:2002 efficiency: F6, F7.
Opacimetric efficiency: 65, 85%.
IN

W
IE
DI

VI F
DU TI
ALLY CER
D
Eurovent 4/5 efficiency: EU6, EU7.
Recommended final pressure drop: Ecopleat: 350 Pa - Ecopleat MCTA: 250 Pa.
Temperature: 70°C maximum in continuous service.

EFFICIENCY
GUARANTEE

Filter Air flow/pressure Unit Unit


Dimensions Media Energy
Reference Type Model classification EN 3
2 drop at 0.45 m/s m / weight volume
(WxHxD) area m Rating
779:2002 h/Pa kg m3
1020.07.00 ECOPLEAT Ecopleat F6 287x592x48 F6 2.85 1500/105 2 0.01 D
1020.08.00 ECOPLEAT Ecopleat F6 592x592x48 F6 5.89 3000/100 3 0.02 D
1020.05.00 ECOPLEAT Ecopleat F6 305x610x48 F6 3.13 1700/110 2 0.01 D
1020.06.00 ECOPLEAT Ecopleat F6 610x610x48 F6 6.25 3400/110 3 0.02 D
1020.16.00 ECOPLEAT Ecopleat F6 610x610x98 F6 14.1 4000/85 4 0.04 D

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1020.80.02 ECOPLEAT Ecopleat F6 560x190x48 F6 1.8 715/65 1.5 0.01 D
1020.80.03 ECOPLEAT Ecopleat F6 255x480x48 F6 2.1 665/55 1.5 0.01 D
1020.80.04 ECOPLEAT Ecopleat F6 255x830x48 F6 3.6 1100/45 2 0.01 D
1020.80.05 ECOPLEAT Ecopleat F6 255x1130x48 F6 4.8 1570/50 3 0.01 D
1021.07.00 ECOPLEAT Ecopleat F7 287x592x48 F7 2.85 1500/175 2 0.01 B
1021.08.00 ECOPLEAT Ecopleat F7 592x592x48 F7 5.89 3000/160 3 0.02 B
1021.05.00 ECOPLEAT Ecopleat F7 305x610x48 F7 3.13 1700/175 2 0.01 B
1021.06.00 ECOPLEAT Ecopleat F7 610x610x48 F7 6.25 3400/175 3 0.02 B
1021.16.00 ECOPLEAT Ecopleat F7 610x610x98 F7 14.1 4000/120 4 0.04 B
1020.80.01 ECOPLEAT MCTA 352x225x48 F6 1.3 350/38 1 0.01 D
1020.80.10 ECOPLEAT MCTA 400x240x48 F6 1.6 340/25 1.2 0.01 D
1020.80.11 ECOPLEAT MCTA 470x240x48 F6 1.9 680/50 1.3 0.01 D
1020.80.12 ECOPLEAT MCTA 550x240x48 F6 2.2 680/42 1.4 0.01 D
Other dimensions available - Other models available, contact us - Also available in incinerable version: Ecopleat Green.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

38
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Pleated Compact Filter

Riga-Flo

Advantages
• Range of standard sizes • High efficiency

Pre-Filtration, Class G3 to F5
• Rigid design concept • Suitable for turbulent airflow

Application: Air conditioning applications.


Type: Rigid pleated filter.
Case: Galvanised steel.
Media: Glass fibre.
EN 779:2002 efficiency: F5 (40-45%), F6 (55-65%), F7 (80-85%), F8 (90-95%).
Eurovent 4/5 efficiency: EU5, EU6, EU7, EU8.
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
Temperature: 70°C maximum in continuous service.

Bag and Compact Filters,


Holding frames: Front and side access housings and frames are available.

Class F5 to F9
TIFICAT
ER
E
C

EN 779:2002
IN

D
IE
DI

VI F
TI
W
DU
ALLY CER
D

H E PA / U L PA F i l t e r s , C l a s s
EFFICIENCY
GUARANTEE

H10 to U17
Filter classification EN Media surface Air flow/presure drop at m 3 / Unit weight kg
Reference Type Model Dimensions (WxHxD) mm Unit volume m 3
779:2002 m2 h/Pa
060558-007 Riga Flo Riga Flo 10 594x594x292 F5 5.4 3420/65 7.70 0.11
060558-012 Riga Flo Riga Flo 10 492x594x292 F5 4.4 2790/65 5.77 0.11
060558-008 Riga Flo Riga Flo 10 289x594x292 F5 2.6 1710/65 4.55 0.06
078367-007 Riga Flo Riga Flo 10 594x594x152 F5 2.7 2070/55 3.42 0.06
078367-016 Riga Flo Riga Flo 10 492x594x152 F5 2.2 1710/55 2.57 0.06

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

078367-008 Riga Flo Riga Flo 10 289x594x152 F5 1.3 990/55 2.21 0.03
060558-001 Riga Flo Riga Flo 15 594x594x292 F6 5.4 3420/70 7.70 0.11
060558-009 Riga Flo Riga Flo 15 492x594x292 F6 4.4 2790/70 5.77 0.11
060558-004 Riga Flo Riga Flo 15 289x594x292 F6 2.6 1710/70 4.55 0.06
078367-001 Riga Flo Riga Flo 15 594x594x152 F6 2.7 2070/65 3.42 0.06
078367-013 Riga Flo Riga Flo 15 492x594x152 F6 2.2 1710/65 2.57 0.06
078367-004 Riga Flo Riga Flo 15 289x594x152 F6 1.3 990/65 2.21 0.03
060558-002 Riga Flo Riga Flo 100 594x594x292 F7 5.4 3420/90 7.70 0.11
060558-010 Riga Flo Riga Flo 100 492x594x292 F7 4.4 2790/90 5.77 0.11
060558-005 Riga Flo Riga Flo 100 289x594x292 F7 2.6 1710/90 4.55 0.06
Filter Frames and Housings

078367-002 Riga Flo Riga Flo 100 594x594x152 F7 2.7 2070/90 3.42 0.06
078367-014 Riga Flo Riga Flo 100 492x594x152 F7 2.2 1710/90 2.57 0.06
078367-005 Riga Flo Riga Flo 100 289x594x152 F7 1.3 990/90 2.21 0.03
060558-003 Riga Flo Riga Flo 200 594x594x292 F8 5.4 3420/130 7.70 0.11
060558-011 Riga Flo Riga Flo 200 492x594x292 F8 4.4 2790/130 5.77 0.11
060558-006 Riga Flo Riga Flo 200 289x594x292 F8 2.6 1710/130 4.55 0.06
078367-003 Riga Flo Riga Flo 200 594x594x152 F8 2.7 2070/175 3.42 0.06
078367-015 Riga Flo Riga Flo 200 492x594x152 F8 2.2 1710/175 2.57 0.06
078367-006 Riga Flo Riga Flo 200 289x594x152 F8 1.3 990/175 2.21 0.03
Other sizes are available on request - PH version also available (with header frame)
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

39
Bag and Compact Filters, Class F5 to F9

Pleated Compact Filter

OpakAir

Advantages
• Large surface area • Less frequent changes
• Up to 6000 m 3 /hr air flow • Low pressure drop

Application: High air flow air conditioning and process air applications.
Type: High capacity compact filter.
Case: Galvanised steel.
Gasket: Half round EDPM.
Media: Glass fibre paper.
Separator: Hot-melt beads.
TIFICAT
ER
Sealant: Polyurethane.
E
C

EN 779:2002
EN 779:2002 efficiency: F8.
IN

D
IE
DI

VI F
W
DU TI
D
ALLY CER

Opacimetric efficiency: 95%.


Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).
Temperature: 70°C maximum in continuous service.
Mounting System: Front and side access housings and safechange systems are available.
EFFICIENCY
GUARANTEE

Dimensions Filter classification Air flow/pressure drop Media Unit Unit


Reference Type Model (WxHxD) mm EN 779:2002 m³/hr/Pa area m 2 weight kg volume m 3
1514.13.05 OPAKAIR -95 OPR-E-F8 610x610x292 F8 4500/110 19,0 18,00 0,11
1514.53.05 OPAKAIR -95 OPR-E-F8 305x610x292 F8 2250/110 10,0 9,00 0,06

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

40
Bag and Compact Filters, Class F5 to F9

Camfil Farr Solutions


Pleated Compact Filter

Airopac ®

Advantages
• Low pressure drop • Large surface area

Pre-Filtration, Class G3 to F5
• Robust metal header frame • Rigid design concept
• High dust holding capacity

Application: Air conditioning applications and preparatory filtration in clean rooms.


Type: High efficiency compact filter, HF model with header frame.
Case: Galvanised steel.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
EN 779:2002 efficiency: F7.

Bag and Compact Filters,


W D Opacimetric efficiency: 85%.
Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).

Class F5 to F9
Temperature: 70°C maximum in continuous service.
Mounting system: Front and side access housing and frames are available, type 8, type L and
FC housings.

EFFICIENCY
GUARANTEE

H E PA / U L PA F i l t e r s , C l a s s
Dimensions Air flow/nominal Media area Unit Unit Energy
Reference Type Model (WxHxD) mm pressure drop m³/h/Pa m2 weight kg volume m 3 Rating

H10 to U17
304215 Airopac-90 3GGM-24246-90 610x610x150 3600/105 12,3 6,8 0,06 B
304219 Airopac-90 3GGM-12246-90 305x610x150 1800/110 6,1 4,0 0,03 B
301732 Airopac-HF-90 3GGMHF-24245-90 592x592x135 3600/135 10,3 6,8 0,05 B
301739 Airopac-HF-90 3GGMHF-12245-90 287x592x135 1800/160 4,5 3,8 0,02 B

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

41
Bag and Compact Filters, Class F5 to F9

Notes

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

42
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


Summary HEPA / ULPA Filters, Class H10 to U17

Pre-Filtration, Class G3 to F5
Filters for High Efficiency Filters for High Efficiency Filters for High Efficiency Filters for High Efficiency
Sofilair - H10 to H14 Sofilair Green Close Pleat - H13 Opakfil G Micretain - H10
Page 45 Page 46 Page 47 Page 48

Bag and Compact Filters,


Class F5 to F9
HEPA/ULPA Panels HEPA/ULPA Panels HEPA/ULPA Panels HEPA/ULPA Panels
Megalam MD, MX, MG Megalam MX & MG - H14 Megalam MD - H10 & H14 Megalam MD & MG - U15
Page 49 Page 50 Page 51 Page 52

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

HEPA/ULPA Panels HEPA/ULPA Panels HEPA/ULPA Panels HEPA/ULPA Panels


Megalam (Laminator) MDL & Silent Hood Diffuser - H14 Megalam U (Gel) - H14 & U15 Megalam T (Gel) - H14 & U15
MXL - U15 & U16 Page 54 Page 55 Page 56
Page 53
Filter Frames and Housings

HEPA/ULPA Panels
Megalam MD & MX e-PTFE -
U15
Page 57
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

43
HEPA / ULPA Filters, Class H 10 to U 1 7

European Standard EN 1822

EN1822

All HEPA / ULPA filters produced by The CAMFIL extra:


Camfil are supplied fully in accordance • Individual test results are recorded on a unique
with the European Standard EN 1822 product label. The label has a detachable copy which
can be used to record the position of the individual
filters within your process.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
SOFILAIR and MEGALAM… what you can • It can also be used as part of the validation process
expect: 100% control of everything we ensuring regulatory compliance of your installation.

produce.
• Qualified personnel responsible for testing. In short EN 1822 means:
• Unique serial number for each filter.
• Individually certified filters
• Clear, unambiguous control procedures specifying test
• Tested using MPPS (Most Penetrating Particle Size)
conditions, target values and actual performance of
our filters. challenge.
• Explicit, standardised test procedures.
• Complete traceability of materials and operations.
• Full traceability of materials and test data.
• Equipment and systems certified by accredited
bodies. • NB: the filter grades EU13 etc, are incompatible with
• Tested performance verified by installation testing
EN 1822.
and validation.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

44
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


Filters for High Efficiency

Sofilair - H10 to H14

Advantages
• High air flow rates, up to 5000 • New ergonomic handle to assist

Pre-Filtration, Class G3 to F5
m 3 /hr with filter changes
• Tested in accordance with • Low pressure drop
EN 1822

Application: Very high efficiency final filtration in air conditioning systems, housings and
diffusers.
Type: High air flow HEPA filter.
Frame: Galvanised steel.
Media: Glass fibre paper.
Separator: Hot-melt beads.

Bag and Compact Filters,


Sealant: Polyurethane.
EN1822 Gasket: One piece half round continuous gasket.

Class F5 to F9
W D EN 1822 efficiency: H10, H12, H13, and H14.
MPPS efficiency: H10:>85%, H12:>99.5%, H13:>99.95%, H14:> 99.995%.
Recommended final pressure drop: 600 Pa.
Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 80°C maximum in continuous service.
Mounting systems: Front and side access filter frames, FC Housings, terminal housings and
safe change systems.

H E PA / U L PA F i l t e r s , C l a s s
Dimensions Filter classification Media Air flow/preassure Unit Unit
Reference Type Model (WxHxD) mm EN 1822 area m 3 drop m 3 /h/Pa weight kg volume m 3

H10 to U17
1575.02.00 Sofilair H10 SFR-E-2000-H10 305x610x292 H10 14 2000/230 8 0,06
1573.02.00 Sofilair H10 SFR-E-4000-H10 610x610x292 H10 21 4000/230 13 0,11
1570.01.00 Sofilair H10 SFR-E-5000-H10 610x610x292 H10 35 5000/230 16,5 0,11
1585.01.00 Sofilair H12 SFR-E-1500-H12 305x610x292 H12 16 1500/250 8,5 0,06
1580.01.00 Sofilair H12 SFR-E-3400-H12 610x610x292 H12 33 3400/250 16,5 0,11
1580.02.00 Sofilair H12 SFR-E-4000-H12 610x610x292 H12 40 4000/250 16,5 0,11

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

1568.01.00 Sofilair H13 SFR-E-1300-H13 289x595x292 H13 16 1300/250 8,5 0,06


1565.01.00 Sofilair H13 SFR-E-1500-H13 305x610x292 H13 16 1500/250 8,5 0,06
1567.01.00 Sofilair H13 SFR-E-3200-H13 595x595x292 H13 38 3200/250 15,5 0,11
1560.01.00 Sofilair H13 SFR-E-3400-H13 610x610x292 H13 33 3400/250 16,5 0,11
1560.02.00 Sofilair H13 SFR-E-4000-H13 610x610x292 H13 40 4000/250 16,5 0,11
1560.02.20 Sofilair H13 SFR-E-5000-H13 610x610x292 H13 40 5000/400 16,5 0,11
1400/280
1565.01.02 Sofilair H14 SFR-E-1400-H14 610x305x292 H14 16 8,5 0,06
1500/310*
3500/270
Filter Frames and Housings

1560.02.06 Sofilair H14 SFR-E-3500-H14 610x610x292 H14 40 16,5 0,11


4000/310*
*Maximum airflow
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

45
HEPA / ULPA Filters, Class H 10 to U 1 7

Filters for High Efficiency

Sofilair Green

Advantages
• Totally incinerable • New ergonomic handle to assist
• High air flow rates with filter changes
• Light weight construction • Corrosion resistant

Application: High efficiency final filtration in air conditioning systems, extraction from corrosive
or hazardous environments.
Type: High air flow incinerable HEPA filter.
Frame: ABS.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Gasket: One piece half round continuous gasket.
EN1822 EN 1822 efficiency: H10, H12, H13, H14.
W D MPPS efficiency: H10:>85%, H13:>99.95 & H14:>99.995%.
Recommended final pressure drop: 600 Pa.
Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 60°C maximum in continuous service.
Mounting systems: Front and side access filter frames. Terminal housings and safe change
systems.

Dimensions Filter Unit Unit


Reference Media area Airflow/pressure
Type Model (LxHxD) classification weight volume
m2 drop m 3 /h/Pa
mm EN 1822 kg m3
1575.82.00 Sofilair Green H10 SFRG-P-2000-H10 305x610x292 H10 13 2000/230 6 0,06
1570.81.00 Sofilair Green H10 SFRG-P-5000-H10 610x610x292 H10 33 5000/230 12 0,11
1585.81.00 Sofilair Green H12 SFRG-P-1500-H12 305x610x292 H12 15 1500/250 10 0,06
1580.82.00 Sofilair Green H12 SFRG-P-4000-H12 610x610x292 H12 38 4000/250 13,5 0,11
1565.81.00 Sofilair Green H13 SFRG-P-1500-H13 305x610x292 H13 15 1500/250 6 0,06
1560.82.00 Sofilair Green H13 SFRG-P-4000-H13 610x610x292 H13 38 4000/250 12 0,11

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1400/280
1565.81.02 Sofilair Green H14 SFRG-P-1400-H14 305x610x292 H14 15 6 0,06
1500/310*
3500/270
1560.82.06 Sofilair Green H14 SFRG-P-3500-H14 610x610x292 H14 38 12 0,11
4000/310*

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

46
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


Filters for High Efficiency

Close Pleat - H13

Advantages
• Range of standard sizes • Very high efficiency

Pre-Filtration, Class G3 to F5
• Compact design concept

Application: Very high efficiency final filtration in air conditioning systems, housings, ducts and
diffusers.
Type: Close pleated very high efficiency filter.
Frame: Galvanised steel / MDF.
Gasket: Half round continuous expanded polyurethane.
Media: Pleated glass paper.
Separator: Hot melt beads.
Sealant: Polyurethane.

Bag and Compact Filters,


EN 1822 efficiency: H13.
EN1822 MPPS efficiency: ≥ 99.95%.
W

Class F5 to F9
D DOP efficiency ≈ 0.3 μm: ≥ 99.99%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Mounting systems: FCB Housings, Ducts, Diffusers, CAMSAFE.

Dimensions Filter classification Air flow/pressure drop Media area Unit Unit

H E PA / U L PA F i l t e r s , C l a s s
Reference Type Model (WxHxD) mm EN 1822 m³/hr/Pa m2 weight kg volume m 3
229004A1 Steel case HEPA TREA-1000 610x610x292 H13 2700 / 250 23,5 13 0,13

H10 to U17
229002A1 Steel case HEPA TREA-450 305x610x292 H13 1350 / 250 11,7 7 0,07
231007A1 Steel case HEPA MXEA-600 610x610x150 H13 1625 / 250 13,4 12 0,07
231004A1 Steel case HEPA MXEA-220 305x610x150 H13 820 / 250 6,7 6 0,04
226001A1 MDF case HEPA TRSA-1000 610x610x292 H13 2450 / 250 21,4 13 0,13
226003A1 MDF case HEPA TRSA-450 305x610x292 H13 1160 / 250 10,1 7 0,07
225006A1 MDF case HEPA MXSA-600 610x610x150 H13 1475 / 250 12,1 12 0,07

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

225007A1 MDF case HEPA MXSA-220 305x610x150 H13 690 / 250 5,7 6
Alternative models, sizes and constructions are available.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

47
HEPA / ULPA Filters, Class H 10 to U 1 7

Filters for High Efficiency

Opakfil G Micretain - H10

Advantages
• Easy to install • Up to 4000 m 3 /hr air flow
• Incinerable

Application: Final filtration in air conditioning systems, industrial processes.


Type: Very high efficiency, incinerable, compact filter.
Frame: 25 mm thick flange, polypropylene and ABS.
Gasket: Half round continuous expanded polyurethane. Position: 01- rear, 10- front.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
EN 1822 efficiency: H10.
MPPS efficiency: ≥ 85%.
Recommended final pressure drop: 450 Pa.
W
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
D
occur.
Temperature: 70°C maximum in continuous service.
Holding Frames: Front and side access housings and frames are available. Type 8, Type L and
FC housings.

Filter Air flow / Unit Unit


Dimensions Media pressure
Reference Type Model classification EN 2 drop weight volume
(WxHxD) mm area m
1822 m 3 /hr/Pa kg m3
1511.36.51 70PGHF-241212 Opakfil-G Micretain 592x287x290-01 H10 9.0 1700/250 3 0.06
1511.35.51 70PGHF-242412 Opakfil-G Micretain 592x592x290-01 H10 19.0 4000/250 6 0.11
1511.36.52 70PGHF-241212 Opakfil-G Micretain 592x287x290-10 H10 9.0 1700/250 3 0.06
1511.35.52 70PGHF-242412 Opakfil-G Micretain 592x592x290-10 H10 19.0 4000/250 6 0.11

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

48
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


H E PA / U L PA P a n e l s

Megalam MD, MX, MG

Advantages
• Less pressure drop • Longer operating life

Pre-Filtration, Class G3 to F5
• Quieter • Higher flow rate

Example: Megalam H14 / 6P6


MD MX MG
2 2
Filter area 10m 12.5m 18m2

Pressure drop 0.45 m/s (600m3/h) 120 Pa 90 Pa (-25%) 70 Pa (-40%)


3 3
Maximum pressure drop 900 m /h (190 Pa) 600 m /h (90 Pa) 2000 m3/h (250 Pa)
EN1822
W Energy -25% -42%

Bag and Compact Filters,


D
Lifespan x 1.5 x 2.5

Class F5 to F9
Less pressure loss More Flow

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Lower pressure drop


Higher airflow rate
More energy savings
Longer operating life
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

49
HEPA / ULPA Filters, Class H 10 to U 1 7

H E PA / U L PA P a n e l s

Megalam MX & MG - H14

Advantages
• Low pressure drop • Longer operating life
• Quiet: LW = 35dB • Individually scanned in
• Higher flow rate accordance with EN 1822

Application: Final or return filtration for clean rooms with turbulent flow.
Type: HEPA filtering panel with seal for mechanical clamping systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
EN1822
Sealant: Polyurethane.
W D
Grid: Mild steel painted grille upstream and downstream.
EN 1822 efficiency: H14.
MPPS efficiency: ≥ 99.995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: see table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housing.

Filter Med Air flow/ Air flow/ Unit


Dimensions classifica ia pressure pressure Unit volu
Reference Type Model weig
(WxHxD) mm tion EN area drop m/s drop max me
ht kg
1822 m2 m 3 /h/Pa m 3 /h/Pa m3
3440.00.20 MEGALAM MXA 3P6 305x610x90 H14 6.3 300/90 650/195 3.0 0.02
3440.00.30 MEGALAM MXA 6P6 610x610x90 H14 12.7 600/90 1300/195 6.0 0.05
3440.00.40 MEGALAM MXA 9P6 915x610x90 H14 19.1 900/90 1950/195 9.0 0.05
3440.00.50 MEGALAM MXA 12P6 1220x610x90 H14 28.3 1200/90 2500/195 12.0 0.07
3444.00.20 MEGALAM MGA 3P6 305x610x110 H14 9.8 300/70 1000/220 5.0 0.02

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3444.00.30 MEGALAM MGA 6P6 610x610x110 H14 19.8 600/70 2000/220 8.0 0.04
3444.00.40 MEGALAM MGA 9P6 915x610x110 H14 27.0 900/70 3000/220 10.0 0.06
3444.00.50 MEGALAM MGA 12P6 1220x610x110 H14 36.3 1200/70 4000/220 13.0 0.08
Other dimensions available on request - Also available with laminator

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

50
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


H E PA / U L PA P a n e l s

Megalam MD - H10 & H14

Advantages
• Low pressure drop • Guaranteed performance

Pre-Filtration, Class G3 to F5
• Protection via 2 grids

Application: Final or return filtration for clean rooms with turbulent flow.
Type: HEPA filtering panel with seal for mechanical clamping mounting systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Grid: Mild steel painted grille upstream and downstream.

Bag and Compact Filters,


EN 1822 efficiency: H10 / H14.
EN1822 MPPS efficiency: H10: ≥ 85%, H14: ≥99.995%.
W

Class F5 to F9
D DOP efficiency: H10: ≥ 95%, H14: ≥ 99.999%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: : 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housings.

H E PA / U L PA F i l t e r s , C l a s s
Filter Air flow / pressure Unit Unit
Dimensions Media
Reference Type Model classification EN drop at 0.45 m/s weight volume
(WxHxD) mm area m 2
1822 m 3 /h/Pa kg m3

H10 to U17
3401.61.11 MEGALAM MDM 3P6 305x610x66 H10 4.6 300/70 2.0 0.02
3401.62.08 MEGALAM MDM 6P6 610x610x66 H10 9.3 600/70 4.0 0.03
3401.63.01 MEGALAM MDM 9P6 915x610x66 H10 14.0 900/70 6.0 0.05
3401.64.07 MEGALAM MDM 12P6 1220x610x66 H10 18.5 1200/70 9.0 0.07
3423.00.10 MEGALAM MDA 3P3 305x305x66 H14 2.4 150/140 1.0 0.01
3423.00.20 MEGALAM MDA 3P6 305x610x66 H14 4.8 300/130 3.0 0.02

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

3423.00.30 MEGALAM MDA 6P6 610x610x66 H14 10.0 600/120 5.0 0.03
3423.00.90 MEGALAM MDA 7P6 762x610x66 H14 12.3 750/120 5.0 0.04
3423.00.40 MEGALAM MDA 9P6 915x610x66 H14 14.8 900/120 6.0 0.05
3423.00.50 MEGALAM MDA 12P6 1220x610x66 H14 19.8 1200/120 9.0 0.07
3423.00.60 MEGALAM MDA 15P6 1525x610x66 H14 24.9 1500/120 10.0 0.07
3423.01.00 MEGALAM MDA 9P7 915x762x66 H14 18.6 1125/120 7.5 0.06
3423.01.10 MEGALAM MDA 12P7 1220x762x66 H14 24.9 1500/120 10.0 0.07
3423.01.20 MEGALAM MDA 15P7 1525x762x66 H14 31.0 1875/120 12.5 0.09
Filter Frames and Housings

3423.01.30 MEGALAM MDA 18P7 1830x762x66 H14 37.2 2250/120 12.5 0.12
3423.01.40 MEGALAM MDA 3P9 305x915x66 H14 7.4 450/120 3.0 0.03
3423.01.50 MEGALAM MDA 9P9 915x915x66 H14 22.3 1350/120 9.0 0.06
3423.01.60 MEGALAM MDA 12P9 1220x915x66 H14 30.0 1800/120 12.0 0.08
Other dimensions available on request
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

51
HEPA / ULPA Filters, Class H 10 to U 1 7

H E PA / U L PA P a n e l s

Megalam MD & MG - U15

Advantages
• Guaranteed performance • Protection via 2 grids
• 100% individual scanning test • Very high efficiency
according to standard EN 1822

Application: Final or return filtration for clean rooms with turbulent flow.
Type: ULPA filtering panel with seal for mechanical clamping systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Grid: Mild steel painted grille upstream and downstream.
EN1822 EN 1822 efficiency: U15.
W D MPPS efficiency: ≥ 99.9995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housings.

Air flow / Unit Unit


Dimensions Filter classification Media pressure drop volume
Reference Type Model weight
(WxHxD) mm EN 1822 area m 2 m 3 /hr/Pa kg m3
3445.00.30 MEGALAM MGGS 6P6 610x610x110 U15 8.0
3418.00.10 MEGALAM MDGS 3P3 305x305x66 U15 2,8 150/140 1.0 0,01
3418.00.20 MEGALAM MDGS 3P6 305x610x66 U15 5,5 300/140 2.0 0,02
3418.00.30 MEGALAM MDGS 6P6 610x610x66 U15 11,2 600/140 4.0 0,03
3418.00.90 MEGALAM MDGS 7P6 762x610x66 U15 14 750/140 5.0 0,04
3418.00.40 MEGALAM MDGS 9P6 915x610x66 U15 16,9 900/140 6.0 0,05

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3418.00.50 MEGALAM MDGS 12P6 1220x610x66 U15 22,5 1200/140 8.0 0,07
3418.00.60 MEGALAM MDGS 15P6 1525x610x66 U15 28,3 1500/140 10.0 0,07
3418.00.80 MEGALAM MDGS 3P7 305x762x66 U15 7 375/140 2.5 0,02
3418.01.00 MEGALAM MDGS 9P7 915x762x66 U15 21,1 1125/140 7.5 0,06
3418.01.10 MEGALAM MDGS 12P7 1220x762x66 U15 28,3 1500/140 10.0 0,07
3418.01.20 MEGALAM MDGS 15P7 1525x762x66 U15 35,3 1875/140 12.5 0,09
3418.01.40 MEGALAM MDGS 3P9 305x915x66 U15 8,3 450/140 3.0 0,03
3418.01.50 MEGALAM MDGS 9P9 915x915x66 U15 25,3 1350/140 9.0 0,06
3418.01.60 MEGALAM MDGS 12P9 1220x915x66 U15 33,9 1800/140 12.0 0,08

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

52
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


H E PA / U L PA P a n e l s

Megalam (Laminator) MDL & MXL - U15 & U16

Advantages
• Laminarity better than +/- 20% • Integrated laminator screen

Pre-Filtration, Class G3 to F5
• 100% individual scanning test • ULPA U15 and U16
according to standard EN 1822

Application: Final filtration for clean rooms, clean devices and units with laminar flow.
Type: ULPA filtering panel with laminator and gasket for mechanical clamping systems.
Frame: Extruded and anodised aluminium.
Gasket: Half round continuous expanded polyurethane.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.

Bag and Compact Filters,


Laminator: Screen bonded downstream for laminar diffusion.
EN1822 Grid: Mild steel painted grille placed upstream.
W

Class F5 to F9
D EN 1822 efficiency: U15 / U16.
MPPS efficiency: U15: ≥99.9995%, U16: ≥99.99995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned to EN 1822.
Mounting system: Mechanical clamping structure, Terminal housings.

H E PA / U L PA F i l t e r s , C l a s s
Filter Unit
Dimensions Media Air flow/pressure Unit weight volume
Reference Type Model classification EN area

H10 to U17
(WxHxD) mm m² drop m³/h/Pa kg
1822 m3
3449.20.40 MEGALAM MDLGS 9P6-01 915x610x66 U15 16.9 900/150 6.0 0.05
3449.00.40 MEGALAM MDLGS 9P6-10 915x610x66 U15 16.9 900/150 6.0 0.05
3449.20.50 MEGALAM MDLGS 12P6-01 1220x610x66 U15 22.5 1200/150 8.0 0.07
3449.00.50 MEGALAM MDLGS 12P6-10 1220x610x66 U15 22.5 1200/150 8.0 0.07
3450.20.40 MEGALAM MDLSGS 9P6-01 915x610x66 U16 18.4 900/165 6.0 0.05

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

3450.00.40 MEGALAM MDLSGS 9P6-10 915x610x66 U16 18.4 900/165 6.0 0.05
3450.00.50 MEGALAM MDLSGS 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07
3450.20.50 MEGALAM MDLSGS 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07
3425.20.30 MEGALAM MXLGS 6P6-01 610x610x90 U15 15.4 600/120 5.6 0.05
3425.00.30 MEGALAM MXLGS 6P6-10 610x610x90 U15 15.4 600/120 5.6 0.05
Other dimensions available on request
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

53
HEPA / ULPA Filters, Class H 10 to U 1 7

H E PA / U L PA P a n e l s

Silent Hood Diffuser - H14

Advantages
• H14 compact filter-diffuser for • Quiet: LW = 35 dB
clean room • Laminarity +/- 20%
• Ready to install

Application: Final filtration for clean rooms.


Type: Ready to install HEPA/ULPA filter diffuser.
Frame: Extruded and anodised aluminium, galvanised steel cover.
Gasket: 10x5mm neoprene, self adhesive ready for installation.
Media: Glass fibre paper.
Separator: Hot melt beads.
Sealant: Polyurethane.
Connection: Spigot with outer dia. 315mm or 250mm depending on the model.
Grid: Downstream in painted mild steel.
EN 1822 efficiency: H14.
MPPS efficiency: ≥99.995%.
Recommended final pressure drop: 600 Pa.
Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.
Mounting system: Mechanical clamping structures.

Air flow/nominal
Dimensions (WxHxD) Filter classification media Unit Unit volume
Reference Type Model pressure drop
mm EN 1822 area m 2 m³/h/Pa weight kg m3

5970.00.21 Silent Hood MDSHA RF1 300x600x116/250 H14 4.2 300/140 10 0.03
5975.00.31 Silent Hood MDSHA RF1 600x600x116/315 H14 9.2 600/140 13 0.06
5975.00.41 Silent Hood MDSHA RF 905x600x116/335 H14 14 900/140 16 0.09
5975.00.51 Silent Hood MDSHA RF1 1210x600x116/315 H14 19 1200/140 19 0.13
5975.00.20 Silent Hood MDSHA RF1 305x610x116/250 H14 4.3 300/140 10 0.03
5975.00.30 Silent Hood MDSHA RF1 610x610x116/315 H14 9.4 600/140 13 0.06

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
5975.00.40 Silent Hood MDSHA RF 915x610x116/315 H14 14.6 900/140 16 0.09
5975.00.50 Silent Hood MDSHA RF 1220x610x116/315 H14 19.5 1200/140 19 0.13
Other dimensions available on request. Available in other grades and with a laminator

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

54
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


H E PA / U L PA P a n e l s

Megalam U (Gel) - H14 & U15

Advantages
• Leaktightness by means of gel • Can be assembled without

Pre-Filtration, Class G3 to F5
• 100% individual control clamping

Application: Final filtration for clean rooms and housings.


Type: HEPA/ULPA filter with gel seal.
Frame: Anodized aluminium.
Gasket: PU gel.
Media: Glass fibre paper.
Separator: Hot melt beads.
Sealant: Polyurethane.
Grid: Mild steel white epoxy paint upstream and downstream.

Bag and Compact Filters,


EN 1822 efficiency: H14 and U15.
EN1822 MPPS efficiency: H14 = 99.995%, U15 = 99.9995%.
W

Class F5 to F9
D Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.

Filter Air flow / Unit


Dimensions Media Air flow/pressure Unit
Reference Type classification pressure drop weight
EN 1822 (WxHxD)mm area m² drop m³/h/Pa max m³/h/Pa volume m³ kg
3413.08.96 MEGALAM MDA U H14 305x305x78 2.4 150/120 250/200 0.01 2.0

H E PA / U L PA F i l t e r s , C l a s s
3413.08.89 MEGALAM MDA U H14 305x610x78 4.8 300/120 300/200 0.02 4.0
3413.08.79 MEGALAM MDA U H14 610x610x78 10.0 600/120 1000/200 0.03 6.0
3413.08.87 MEGALAM MDA U H14 915x610x78 14.8 900/120 1500/200 0.05 8.0

H10 to U17
3413.08.90 MEGALAM MDA U H14 1220x610x78 19.8 1200/120 2000/200 0.06 11.0
3413.08.97 MEGALAM MDA U H14 305x762x78 6.1 375/120 625/200 0.02 4.5
3413.08.98 MEGALAM MDA U H14 915x762x78 18.6 1125/120 1875/200 0.05 9.0
3413.08.91 MEGALAM MDA U H14 1220x762x78 24.9 1500/120 2500/200 0.07 13.0
3413.08.88 MEGALAM MDA U H14 915x915x78 22.3 1350/120 2250/200 0.06 12.0
3413.08.95 MEGALAM MDA U H14 1220x915x78 29.0 1800/120 3000/200 0.08 15.0

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

3413.08.82 MEGALAM MDGS U U15 762x610x78 14.0 750/140 - 0.04 6.5


3413.08.81 MEGALAM MDGS U U15 915x610x78 16.9 900/140 - 0.05 8.0
3413.18.02 MEGALAM MDGS U U15 915x762x78 21.1 1125/140 - 0.05 9.0
3413.08.84 MEGALAM MDGS U U15 1220x762x78 28.3 1500/140 - 0.07 13.0
3413.08.80 MEGALAM MDGS U U15 915x915x78 25.3 1350/140 - 0.06 12.0
Other dimensions available on request.
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

55
HEPA / ULPA Filters, Class H 10 to U 1 7

H E PA / U L PA P a n e l s

Megalam T (Gel) - H14 & U15

Advantages
• Compact design • 100% individually scann tested
• Secure protection of the filter in accordance with EN 1822
media • Laminar air flow distribution

Application: Gel seal filter for terminal housings and laminar flow environments.
Type: HEPA/ULPA filter with gel seal.
Frame: Extruded anodised aluminium.
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Gasket: PU Gel.
EN1822
W EN 1822 efficiency: H14 and U15.
D
MPPS efficiency: H14 = 99.995%, U15 = 99.9995%.
Recommended final pressure drop: 600 Pa.
Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.
Mounting systems: Ceiling mounted grid systems and terminal housings.

Dimensions Media
Filter classification area Air flow/pressure Unit weight
Reference Type Model (WxHxD) Unit volume m 3
mm
EN 1822
m2 drop m 3 /h/Pa kg

3471.x0.10 MEGALAM MDT14 U-305x305x71-2G 305x305x71 H14 2,4 150/120 1 0,01


3471.x0.20 MEGALAM MDT14 U-305x610x71-2G 305x610x71 H14 4,8 300/120 2 0,02
3471.x0.30 MEGALAM MDT14 U-610x610x71-2G 610x610x71 H14 10 600/120 4 0,03
3471.x0.90 MEGALAM MDT14 U-762x610x71-2G 762X610X71 H14 12,3 750/120 5 0,04
3471.x0.40 MEGALAM MDT14 U-915x610x71-2G 915x610x71 H14 14,8 900/120 6 0,05
3471.x0.50 MEGALAM MDT14 U-1220x610x71-2G 1220x610x71 H14 19,8 1200/120 8 0,06
3471.x0.80 MEGALAM MDT14 U-305x762x71-2G 305x762x71 H14 6 375/120 2,5 0,02
3471.x1.00 MEGALAM MDT14 U-915x762x71-2G 915x762x71 H14 18,6 1125/120 7,5 0,06

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3471.x1.10 MEGALAM MDT14 U-1220x762x71-2G 1220x762x71 H14 24,9 1500/120 10 0,07
3471.x1.50 MEGALAM MDT14 U-915x915x71-2G 915x915x71 H14 22,3 1350/120 9 0,06
3471.x1.60 MEGALAM MDT14 U-1220x915x71-2G 1220x915x71 H14 30 1800/120 12 0,08
3472.x0.20 MEGALAM MDT15 U-305x610x71-2G 305x610x71 U15 5,5 300/140 2 0,017
3472.x0.30 MEGALAM MDT15 U-610x610x71-2G 610x610x71 U15 11,2 600/140 4 0,034
3472.x0.90 MEGALAM MDT15 U-762x610x71-2G 762X610X71 U15 14 750/140 5 0,042
3472.x0.40 MEGALAM MDT15 U-915x610x71-2G 915x610x71 U15 16,9 900/140 6 0,051
3472.x0.50 MEGALAM MDT15 U-1220x610x71-2G 1220x610x71 U15 22,5 1200/140 8 0,068
3472.x0.80 MEGALAM MDT15 U-305x762x71-2G 305x762x71 U15 7 375/140 2,5 0,021
3472.x1.00 MEGALAM MDT15 U-915x762x71-2G 915x762x71 U15 21,1 1125/140 7,5 0,064
3472.x1.10 MEGALAM MDT15 U-1220x762x71-2G 1220x762x71 U15 28,3 1500/140 10 0,069
3472.x1.50 MEGALAM MDT15 U-915x915x71-2G 915x915x71 U15 25,3 1200/140 9 0,062
Please Note:
Seal Position "01" : x = 2
Seal Position "10" : x = 3
Other dimensions available on request

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

56
H E PA / U L PA F i l t e r s , C l a s s H 1 0 t o U 1 7

Camfil Farr Solutions


H E PA / U L PA P a n e l s

Megalam MD & MX e-PTFE - U15

Advantages
• Very high efficiency • Chemical resistance

Pre-Filtration, Class G3 to F5
• High mechanical strength • No outgassing

Application: Very high efficiency final filter for clean environments and LAF benches.
Type: ULPA filter.
Frame: Extruded anodised aluminium.
Media: e PTFE (Teflon).
Separator: Hot-melt beads.
Sealant: Polyurethane.
Gasket: Half round continuous expanded polyurethane.
EN 1822 efficiency: U15

Bag and Compact Filters,


MPPS efficiency: > 99.9995%
EN1822 Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency may
W

Class F5 to F9
D occur.
Temperature: 70°C maximum in continuous service.
Test: 100% individually scanned in accordance with EN 1822.
Mounting system: Ceiling mounted grid systems, terminal housings and clean devices.

Filter classification Dimensions Media Air flow/Preassure Unit Unit


Reference Type EN 1822 (WxHxD)mm area m² drop m³/h/Pa volume m³ weight kg

H E PA / U L PA F i l t e r s , C l a s s
1645020Z MD15/PTFE-305×610 U15 305x610x66 4,80 300/105 0,017 2,00
1645050B MD15/PTFE-610×610 U15 610x610x66 9,70 605/100 0,034 4,00
1645150 MD15/PTFE-1220×610 U15 1220x610x66 19,50 1205/100 0,068 8,00

H10 to U17
164550P1 MD15/PTFE-1220×915 U15 1220x915x66 29,20 1810/100 0,083 12,00

164902 MX15/PTFE-305×610 U15 305x610x90 6,60 300/85 0,023 2,80


164907 MX15/PTFE-610×610 U15 610x610x90 13,20 605/80 0,046 5,60
1649000 MX15/PTFE-1220×610 U15 1220x610x90 26,60 1205/80 0,092 11,20
16490000 MX15/PTFE-1220×915 U15 1220x915x90 40,10 1810/80 0,112 16,80

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

57
HEPA / ULPA Filters, Class H 10 to U 1 7

Notes

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

58
Carbon and Chemical Filters

Camfil Farr Solutions


Summary Carbon and Chemical Filters

Pre-Filtration, Class G3 to F5
Compact 2 in 1 solution Compact 2 in 1 solution Compact Carbon Filter Carbon Cylinders
CityFlo CityCarb ® CitySorb Camcarb Green
Page 62 Page 63 Page 64 Page 65

Bag and Compact Filters,


Class F5 to F9
Carbon Cylinders Bonded and Loose Filled
Camcarb Mounting Frames Carbon Panels
Page 66 Camsure

H E PA / U L PA F i l t e r s , C l a s s
Page 67

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

59
Carbon and Chemical Filters

I n d o o r a i r q u a l i t y, E N 1 3 7 7 9

The industrialised world pollution does not pass us by. It takes numerous different forms, for
example vehicle exhaust gas, factory chimneys, the dust raised by car
The industrialised world has changed immeasurably over the past 50 traffic and cigarette smoke. It has been known for some time that
years. One very real difference is that the air that we breathe is more exposure to pollution has an impact on human beings. The common
heavily, and more diversely, polluted. Although there are natural sources symptoms are headaches, watering eyes and lower performance at
of pollution, the main concern is pollution caused by human activity. work. Such symptoms are traditionally referred to as Sick Building
Tens of thousands of synthetic chemicals (which do not exist in any Syndrome or similar terms.
natural state) are now manufactured at an estimated rate of more than a
billion tons per year. These chemicals are released into the atmosphere
when they are produced, and when they are used they can travel great
distances. They inevitably form part of our lives. Our lifestyles (work and
leisure) mean that we spend more and more time inside buildings. The
fact that buildings have to be ventilated means that we are increasingly
exposed to particulate and gas pollution from the outdoor air.

The new European Standard for


Ventilation
European Standard EN 13779 is aimed at achieving a comfortable,
healthy indoor environment in all seasons with acceptable installation
The impact of pollution on our health and running costs. EN 13779 has now been adopted as a national
standard in all countries. It specifies the required filter performance in a
Air pollution can be categorised as either particulate (dust) or gas system to achieve good IAQ taking into consideration contamination in
(molecular). Particles enter the body and the respiratory system via the outdoor air. Outdoor air is split into five categories, from ODA 1, in
breathing. Gas or molecular pollution also penetrates the body via the which the air is pure apart from temporary pollution such as pollen, up
air we breathe, but from the lungs it enters the bloodstream and in turn to ODA 5 with high concentrations of gas and particles. This elevated
infiltrates the whole body. Though these chemicals may be invisible, pollution level ODA 5 is now typical of the contamination in urban areas.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Recommendations in EN 13779 for air filters

IAQ
Outdoor air quality Indoor Air Quality
IDA 1 (High) IDA 2 (Medium) IDA 3 (Moderate) IDA 4 (Low)
ODA 1 F9 F8 F7 F6
ODA 2 F7 / F9 F6 / F8 F6 / F7 G4 / F6
ODA 3 F7 / F9 F8 F7 F6
ODA 4 F7 / F9 F6 / F8 F6 / F7 G4 / F6
ODA 5 F6 / GF / F9 F6 / GF / F9 F6 / F7 G4 / F6
Table refering to appendix "A3. Use of Air Filters" in The European Standard EN 13779.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

60
Carbon and Chemical Filters

Camfil Farr Solutions


Adsorption index of activated carbon

Key:
4. A very high level of adsorption, in the order of 20 - 40% by weight of
dry carbon.
3. Good index with a capacity of 10 - 20%.
2. Mediocre index that may require a particularly long contact time,

Pre-Filtration, Class G3 to F5
requires case by case study.
1. Practically no adsorption, another solution must be sought.

Adsorption index of Activated Carbon for various types of odour

2 Acetaldehyde 1 Carbon monoxide 3 Ethyl bromide 4 Lubricants 3 Pentylene


4 Acetic acid 4 Carbon tetrachloride 1 Ethylene 4 Medicinal odours 3 Pentyne
4 Acetic anhydride 3 Chlorine 4 Ethylene dichloride 4 Menthol 4 Perchloroethylene
3 Acetone 4 Chlorobenzene 3 Ethylene oxide 4 Mercaptan 4 Perfumes, cosmetics

Bag and Compact Filters,


1 Acetylene 4 Chloroform 2 Ethyl mercaptan 1 Methane 4 Perspiration

Class F5 to F9
3 Acids 4 Chloronitropropane 4 Ethyl silicate 3 Methyl acetate 4 Petrol
3 Acrolein 4 Chloropicrin 4 Eucalyptol 4 Methyl acrylate 4 Phenol
4 Acrylic acid 4 Chloroprene 4 Faecal odours 3 Methyl alcohol 3 Phosgene
4 Acrylonitrile 3 Cigarette smells 3 Farmyard smells 3 Methyl bromide 4 Plastics
4 Adhesives 4 Cleaning solvents 4 Fertiliser 4 Methyl butyl ketone 2 Propane
4 Alcohol 3 Cooking smells 3 Film developing 3 Methyl chloride 4 Propanol
4 Amines 4 Creosote 2 Fish odours 4 Methylcyclohexane 2 Propylene

H E PA / U L PA F i l t e r s , C l a s s
2 Ammonia 4 Cresol 4 Floral odours 4 Methylcyclohexanol 4 Propyl mercaptan
2 Amyl acetate 4 Cyclohexane 2 Formaldehyde 4 Méthylcyclohexanone 4 Resins

H10 to U17
4 Amyl alcohol 4 Cyclohexanol 3 Formic acid 4 Methylene chloride 4 Rubber
4 Amyl ether 4 Cyclohexanone 3 Freon 3 Methyl ether 2 Slaughterhouse
3 Anaesthetics 4 Cyclohexene 4 Gangrene smell 4 Methyl ethyl ketone 3 Soap
4 Aniline 4 Deodorants 4 Garlic 4 Methyl isobutyl ketone 3 Solvents
4 Animal carcases 4 Detergents 4 Heptane 4 Methyl mercaptan 4 Styrene monomer
3 Animal odours 4 Dibromoethane 4 Heptylene 4 Monochlorobenzene 2 Sulphur components
4 Antiseptics 4 Dichlorobenzene 3 Hexane 4 Naphtha (coal tar) 2 Sulphur dioxide

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

4 Asphalt fumes 4 Dichloroethane 3 Hexylene 4 Naphtha (oil) 4 Sulphuric acid


3 Bathroom smells 4 Dichloroethylene 3 Hospital odours 4 Naphthalene 3 Sulphur trioxide
4 Benzene 4 Diesel fumes 4 Household smells 4 Nicotine 4 Tar
3 Bleaching solutions 3 Diethylamine 1 Hydrogen 3 Nitric acid 4 Tetrachloroethane
2 Body odours 3 Diethyl ketone 2 Hydrogen bromide 4 Nitrobenzene 4 Tetrachloroethylene
4 Bromine 4 Dimethylaniline 2 Hydrogen chloride 4 Nitroethane 3 Tetrahydrofuran
4 Burnt flesh 4 Dimethylsulfate 2 Hydrogen cyanide 2 Nitrogen dioxide 4 Tobacco odours
3 Butadiene 4 Dioxane 2 Hydrogen fluoride 4 Nitroglycerine 4 Toilet smells
Filter Frames and Housings

2 Butane 4 Dipropyl ketone 3 Hydrogen iodide 4 Nitromethane 4 Toluene


4 Butanone 4 Disinfectants 2 Hydrogen sulphide 4 Nitropropane 4 Trichlorethylene
4 Butyl acetate 4 Embalming products 4 Incense 4 Nitrotoluene 4 Urea
4 Butyl alcohol 4 Essential oils 3 Industrial waste 4 Nonane 4 Uric acid
4 Butyl chloride 1 Ethane 4 Iodine 4 Octane 4 Vehicle exhaust
2 Butylene 3 Ether 4 Iodoform 4 Onions 4 Vinegar
4 Butyric acid 4 Ethyl acetate 3 Isoprene 4 Ozone 3 Vinyl chloride
4 Camphor 4 Ethyl acrylate 4 Isopropyl acetate 4 Paint odours 3 Wood alcohol
4 Caprylic acid 4 Ethyl alcohol 4 Isopropyl alcohol 4 Paradichlorobenzene 4 Xylene
3 Carbon disulphide 3 Ethylamine 4 Kerosene 3 Pentane
A i r F i l t e r Te c h n o l o g y

1 Carbon dioxide 4 Ethylbenzene 4 Lactic acid 4 Pentanone

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

61
Carbon and Chemical Filters

Compact 2 in 1 solution

CityFlo

Advantages
• Double action: particle and • Ideal for filtering most low
odour filtration concentration interior and
• Range of standard sizes exterior pollutants
• Can be used to upgrade existing • Robust metal header frame
installations • Compact “2 in 1” solution

Application: Particle and odour removal in Hospitals, Offices, Airports etc.


Type: Multi pocket particle and gas filter.
Frame: Galvanised steel.
Media: Glass fibre and broad spectrum carbon.
ER
TIFICAT EN 779:2002 efficiency: F7 (80-85%).
E
C

EN 779:2002 Temperature: 50°C maximum in continuous service.


IN

Humidity: 70% RH maximum.


IE
DI

VI F
TI
W
DU
ALLY CER
D
Holding frames: Front and side access holding frames are available: Type 8, Type L and FC
Housings.

Filter Unit
Dimensions Number of Carbon Air flow/pressure Unit Energy
Reference Type classification EN
(WxHxD) mm pockets mass kg drop m³/hr/Pa weight kg volume m 3 rating
779:2002
604001 CITYFLO 592x592x534 F7 10 2 3400/140 6 1,2 B
604002 CITYFLO 287x592x534 F7 5 1 1700/145 3,5 0,6 B
604003 CITYFLO 490x592x537 F7 8 1.5 2550/140 4.6 0.9 B

Two filters in one


Well known bag filter construction is now available with a particle and gas filtration layer. The frame components are made of galvanized sheet metal to
ensure a robust construction.

Ultimate solution
City-Flo is the ultimate solution when a high performance bag filter and a high performance odour removal filter are needed in the same encapsulated

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
space. The filter can be easily fitted into new or existing standard filter frames. High performance Camfil Farr glass fibre media is now combined with an
exclusive broad spectrum carbon media that utilises the benefits of RAD (Rapid Adsorption Dynamics) to remove a wide range of VOCs and odours.

High perfomance by using RAD


The RAD characteristics ensure effective collection of gases within a bag filter design. The carbon also provides high efficiency removal of ozone, a
major pollutant in city environments.

Service life
The filter can be replaced when pressure loss exceeds the maximum allowed value for the ventilation system or after a maximum of one year.

Maintenance
Following good practice for all filters, used City-Flo filters should be bagged immediately after removal from the unit and disposed of by the appropriate
route.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

62
Carbon and Chemical Filters

Camfil Farr Solutions


Compact 2 in 1 solution

CityCarb ®

Advantages
• Compact “2 in 1” solution • 100% incinerable

Pre-Filtration, Class G3 to F5
• Ideal for filtering most low • Can be used to upgrade existing
concentration interior and installations
exterior pollutants • Double action: particle and
• Range of standard sizes odour filtration

Application: High efficiency particle filtration for deodorisation and purification of gas
pollutants, used for filtration in offices, airports and industrial workshops.
Type: High efficiency, activated carbon, incinerable filter.
Frame: Polypropylene.
Media: Synthetic fibre.

Bag and Compact Filters,


W D EN 779:2002 efficiency: F7 with very fine grains of activated carbon.
Maximum flow rate: 4000m3/h.

Class F5 to F9
Mounting system: "Camfil universal frame" frames in kit form, FC type housings.

Dimensions Filter Air flow pressure drop Unit Unit


Carbon Type of for contact time = 0.1 weight Volume
Reference Type Model (WxHxD) classification mass carbon
mm EN 779:2002 s m 3 /h/Pa kg m3

H E PA / U L PA F i l t e r s , C l a s s
5716522 CITYCARB OPKCC-242412-85-0 592x592x290 F7 3 RAD 3400/120 7.5 0.11
5716532 CITYCARB OPKCC-242012-85-0 592x490x290 F7 2.5 RAD 2800/120 6.1 0.09

H10 to U17
5716542 CITYCARB OPKCC-241212-85-0 592x287x290 F7 1.5 RAD 1700/120 3.8 0.05

Citycarb has been specifically designed to easily improve the quality of indoor air due to
its "2 in 1" concept:
1. Highly effective filtration: Classed as F7 according to EN 779:2002, it stops 85% of 1 micron particles and meets the recommendations of UNICLIMA
and EUROVENT 12/1-92.
2. Adsorption of odours and pollution: This specifically designed product can provide efficiencies as high as 99% for Sulphur Dioxide, the main pollutant

Carbon and Chemical Filters


in urban environments.
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Citycarb is easy to use


Citycarb is designed to fit in place of the existing pocket or compact filter within an air handling system. The existing frames can be used because the
filter fixings are the same and as you are not adding an extra filter stage, the pressure drop remains low.

Citycarb uses a special ingredient - RAD


The RAD or Rapid Adsorption Dynamic ensures the optimum efficiency of CityCarb. Rather than the amount of carbon (the traditional measure), it is the
capacity of this new form to rapidly trap gasses which ensures the advanced performance of CityCarb. The carbon is in the form of very small granules
into which gas molecules can rapidly diffuse.
Filter Frames and Housings

Citycarb eliminates the harmful effects of urban pollution


CityCarb is specifically designed to handle common substances found in atmospheric contamination:
NOX is caused by traffic, power stations and industrial plants.
Sulphur Dioxide is mainly produced by power station emissions however traffic pollution greatly adds to the problem.
Ammonia is caused by agriculture and industrial processes.
Hydrochloric acid is a by product from incineration plants.
Volatile Organic Compounds (VOC’s) are casued by vehicle exhaust, solvents and aerosols.
Butadiene 1.3 is caused by vehicle emissions.
Some of these molecules are included in the calculation of the atmospheric pollution index.
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

63
Carbon and Chemical Filters

Compact Carbon Filter

CitySorb

Advantages
• Range of standard sizes • High efficiency
• Rigid design concept • Large air flow capacity

Application: Adsorption of odours and gasses in air conditioning applications.


Type: Rigid pleated filter.
Case: Polystyrene.
Media: Multilayer carbon media.
Sealant: Polyurethane.
Separators: Hot-melt.
Gasket: One piece PU gasket.
Recommended temperature range: 0-40°C.
W D Recommended relative humidity: < 70% RH.
Holding frames: Front and side access housings and frames are available, Type 8, Type L and
FC Housings.

Dimensions Air flow / pressure drop Unit weight Unit Volume


Reference Type Model (WxHxD) Media area m 2
mm m 3 /hr/Pa kg m3

5718522 CITYSORB OPKCS-242412-01 PU 592x592x292 8.0 3400/80 10.8 0.02


5718532 CITYSORB OPKCS-242012-01 PU 592x490x292 6.6 2800/80 9.2 0.04
5718542 CITYSORB OPKCS-241212-01 PU 592x287x292 3.5 1500/80 5.4 0.02

Citysorb is a high-efficiency compact molecular filter for addressing IAQ issues in public and commercial buildings. This filter satisfies
demands to tackle nuisance odours and provide occupants with the highest indoor air quality as specified in the European Standard EN
13779. The material selection and construction method ensures that Citysorb is a clean, light filter that is both quick and easy to
maintain.

Also available, Citysorb Acid, for more efficient treatment of specific acid molecules.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Temperature 23º C
efficiency %

Humidity 50%
Concentration 80ppm
Airflow 3400 m3/h
Citysorb dP. 91 Pa

adsorbed toluene

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

64
Carbon and Chemical Filters

Camfil Farr Solutions


Carbon Cylinders

Camcarb Green

Advantages
• Completely incinerable • Conical inlet

Pre-Filtration, Class G3 to F5
• Low pressure drop • Rapid bayonet fitting system
• Reduced weight • Corrosion resistant
• Two integral moulded TPE • High performance
gaskets

Application: Adsorption of odours, VOC’s and / or low toxicity gases for airports, museums,
kitchens, hospitals or clean room industry.
Type: Cylindrical activated carbon cartridge in ABS and HDPE.
Temperature: 40°C maximum in continuous service.
Mounting System: Camcarb mounting frame, FC-CC housings.

Bag and Compact Filters,


Cylinders: ABS plastic.
Carbon: "Broad Spectrum" activated carbon, adsorption of odours, ozone and organic gases,

Class F5 to F9
impregnated activated carbon, adsorption of non-organic gases.
Media: Coconut shell carbon CM05.

Carbon * Airflow/ Unit Unit


Dimensions Carbon weight Carbon pressure volume
Reference Type Model thickness weight
(WxHxD) mm kg type
mm drop m 3 /h/Pa kg m3
571750 Camcarb Green Cylinder 2600 147x93x450 26 2,3 CM 05 80/30 2,7 0,007

H E PA / U L PA F i l t e r s , C l a s s
571760 Camcarb Green Cylinder3500 147x93x600 26 3,1 CM 05 100/30 3,7
* Based on a contact time of 0.2 sec. Alternative models are also available.

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Air flow and air distribution of CAMCARB Green


Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

65
Carbon and Chemical Filters

Carbon Cylinders

Camcarb Mounting Frames

Advantages
• Modular design adaptable for • Rapid fitting system via
all types of installations bayonet fitting
• Reduced weight • Quick and easy service

Application: Assembly of Camcarb activated carbon cylinders.


Type: Quick bayonet-mounted support frame for Camcarb cylinders.
Design: Galvanised steel or stainless steel.
For filters: Camcarb activated carbon cylinders.
Mounting: Bayonet locking.

W D

Dimensions Unit volume


Reference Type Model (WxHxD) Cylinder capacity Unit weight kg
mm m3

1618.60.00 Camcarb Frame G8 305x610x70 8 3.0 0.02


1618.62.00 Camcarb Frame G16 610x610x70 16 4.8 0.04
1618.57.00 Camcarb Frame G8 SS 305x610x70 8 4.0 0.02
1618.59.00 Camcarb Frame G16 SS 610x610x70 16 5.0 0.04

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

66
Carbon and Chemical Filters

Camfil Farr Solutions


Bonded and Loose Filled Carbon Panels

Camsure

Advantages
• Range of standard and non • Clean, dust free construction

Pre-Filtration, Class G3 to F5
standard sizes • Suitable for a wide range of air
• High performance volumes

Application: Adsorption of odours and gases in air conditioning applications.


Type: Bonded and granular carbon panels.
Case: Galvanised steel.
Media: Wide spectrum carbon.
W D
Temperature: 40°C maximum in continuous service.
Mounting systems: Front and side access housings and frames are available.

Bag and Compact Filters,


Nominal size (WxHxD)
Reference Type Air flow / pressure drop m 3 /h/Pa Unit weight kg Unit volume m 3

Class F5 to F9
mm
CPB60060030NOM Bonded Carbon Panel 600x600x30 324/160 6.0 0.012
CPB60030030NOM Bonded Carbon Panel 600x300x30 160/160 3.0 0.006

CPG60060030NOM Granular Carbon Panel 600x600x30 324/127 6.0 0.012


CPG60030030NOM Granular Carbon Panel 600x300x30 160/127 3.0 0.006
Air volume required to give a contact time of 0.1 second.

H E PA / U L PA F i l t e r s , C l a s s
Above are sample sizes, filters are available in a comprehensive range of sizes, please specify.
Also available with stainless steel case.

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

67
Housings, frames & special applications

Summary Housings, frames & special applications

Filter Holding Frames Filter Holding Frames Filter Housing Filter Housing
Absolute Filter Holding Frame Type 8 - Filter Holding Frame FCB-P FCBS-HF
Page 70 Page 71 Page 72 Page 73

Filter Housing Filter Housing Filter Housing Filter Housing


FCBS-A FCBL-CC FCBL-CS FCBL-HF
Page 74 Page 75 Page 76 Page 77

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Terminal Filter Housings Filter Containment Filters for High Filters for High
Pharmaseal Systems Temperature Temperature
Page 78 Camsafe Termikfil 2000 Absolute® 1FRK
Page 79 Page 80 Page 81

Filters for Painting Booths Filters for Painting Booths Filters for Painting Booths Filters for Painting Booths
Paint Extract Filters Airopac® HT-HF Panolair SSI - Micretain H10 CDM Media
Page 82 Page 83 Page 84 Page 85

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

68
Housings, frames & special applications

Camfil Farr Solutions


Pre-Filtration, Class G3 to F5
Filters for Gas Turbines Filters for Gas Turbines Filters for Gas Turbines Dust Collector
Cam GT ® Campulse EF ®
Hi-Flo T Gold Series
Page 86 Page 87 Page 88 Page 89

Bag and Compact Filters,


Class F5 to F9
Dust Collector
HemiPleat Cartridges
Page 90

H E PA / U L PA F i l t e r s , C l a s s
H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

69
Housings, frames & special applications

Filter Holding Frames

Absolute Filter Holding Frame

Advantages
• Modular design adaptable for • Pre drilled for easy assembly
all types of installations • Filter holding clips can be
• Location dimples in frame easily replaced as required
ensure correct filter fitting

Application: Mounting very high efficiency filters in air conditioning units and systems.
Type: Front access filter holding frame.
Construction: Galvanised steel or stainless steel.
Filter Types: Absolute and Micretain very high efficiency filters.
Filter fixing: Using 4 corner mounted clamps.

W D

Exterior dimensions
Reference Type (WxHxD) mm Filter dimension (WxHxD) mm Unit weight kg Unit volume m 3

5107.06.01 Galvanised steel 626x626x335 610x610x292 12.5 0.13


5107.24.01 Galvanised steel 626x321x335 610x305x292 10.0 0.07
5107.60.01 Galvanised steel 610x610x335 595x595x292 12.3 0.12
5107.50.01 Galvanised steel 610x305x335 595x290x292 9.9 0.06
5107.06.02 Stainless steel 626x626x335 610x610x292 12.5 0.13
5107.24.02 Stainless steel 626x321x335 610x305x292 10.0 0.07
5107.60.02 Stainless steel 610x610x335 595x595x292 12.3 0.12
5107.50.02 Stainless steel 610x305x335 595x290x292 9.9 0.06
Other dimensions and arrangements available on request.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

70
Housings, frames & special applications

Camfil Farr Solutions


Filter Holding Frames

Type 8 - Filter Holding Frame

Advantages
• Robust rigid construction • Modular design adaptable for

Pre-Filtration, Class G3 to F5
• Pre drilled for easy assembly all types of installations
• Filter holding clips can be • Location dimples in frame
easily replaced as required ensure correct filter fitting

Application: Mounting air filters in air conditioning systems.


Type: Front access filter holding frame.
Construction: Galvanised steel.
Gasket: Expanded neoprene.
Filter Types: S-Flo W, Hi-Flo, Hi-Cap Bag Filters, 1", 2" and 4" Panel Filters, Opakfil, Airopac,
Rigaflo and Ecopleat.

Bag and Compact Filters,


Filter fixing: Using 4 corner mounted clips, to suit the installed filter.
Note: Remember to order the frame and the appropriate clips.

Class F5 to F9
Reference Type Model Exterior dimensions (WxH) mm Unit weight kg Unit volume m 3
079473-801 Type 8 610x610 610x610x68 2,4 0,04
079473-007 Type 8 508x610 508x610x68 2,2 0,03
079473-002 Type 8 508x508 508x508x68 2,0 0,03
079473-004 Type 8 305x610 305x610x68 1,8 0,02

H E PA / U L PA F i l t e r s , C l a s s
Other materials available on request other dimensions and arrangements available on request.

H10 to U17
Fixing Clips

Reference Type Model


050025-000 C-70 clip for 1" and 2" deep (25 & 50 mm) C-70
074437-000 C-86 clip for 3" deep (75 mm) C-86
059615-001 C-77 clip for 4" deep (100 mm) C-77
059920-006 C-78-5 clip for 5" deep (125 mm) C-78

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Order 4 clips per frame, other materials available on request, clips to suit alternative or combination filters, available on request.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

71
Housings, frames & special applications

Filter Housing

FCB-P

Advantages
• Easy to Install • Gasket to seal between door
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design

Housing: Galvanised steel.


Filter: Panel filters 25mm (1"), 50mm (2") and 95mm (4") deep.
Alternative: Possibility to switch the housings 180° (flexibility to acces from left or right side).
Please note: Stainless steel version is also available.

W D

Exterior dimensions Interior dimensions Number of filters Number of filters Unit volume
Reference Type Model Unit weight kg
(WxHxD) mm (WxH) mm 592x592 mm 287x592 mm m3

604001020 FCB-P 0510 05 10 399×744×202 309×614 - 1 0.06 7.3


604001040 FCB-P 1005 10 05 704×439×202 614×309 - 1 0.07 7.3
604001050 FCB-P 1010 10 10 704×744×202 614×614 1 - 0.12 9.5
604001060 FCB-P 1015 10 15 704×1055×202 614×925 1 1 0.17 15

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
604001070 FCB-P 1020 10 20 704×1360×202 614×1230 2 - 0.21 17
604001080 FCB-P 1025 10 25 704×1670×202 614×1540 2 1 0.26 21.5
604001090 FCB-P 1030 10 30 704×1975×202 614×1845 3 - 0.31 25
604001100 FCB-P 1510 15 10 1013×744×202 923×614 1 1 0.18 13.5
604001110 FCB-P 1520 15 20 1013×1360×202 923×1230 2 2 0.31 23
604001120 FCB-P 1530 15 30 1013×1975×202 923×1845 3 3 0.44 32.5
604001130 FCB-P 2010 20 10 1318×744×202 1228×614 2 - 0.22 15
604001140 FCB-P 2015 20 15 1318×1055×202 1228×925 2 2 0.31 25
604001150 FCB-P 2020 20 20 1318×1360×202 1228×1228 4 - 0.4 26.5
604001160 FCB-P 2025 20 25 1318×1670×202 1228×1540 4 2 0.49 35
604001170 FCB-P 2030 20 30 1318×1975×202 1228×1845 6 - 0.58 37
604001180 FCB-P 2510 25 10 1677×744×500 1537×614 2 0.28 19
604001190 FCB-P 2520 25 20 1677×1360×500 1537×1230 4 2 0.51 32.5
604001200 FCB-P 2530 25 30 1677×1975×500 1537×1845 6 3 0.74 46
604001210 FCB-P 3010 30 10 1982×744×500 1842×614 3 - 0.33 21.5
604001220 FCB-P 3015 30 15 1982×1055×500 1842×925 3 3 0.46 32.5
604001230 FCB-P 3020 30 20 1982×1360×500 1842×1230 6 - 0.6 36
604001240 FCB-P 3025 30 25 1982×1670×500 1842×1540 6 3 0.73 47.5
604001250 FCB-P 3030 3030 1982×1975×500 1842×1842 9 - 0.87 50.5
Other dimensions and arrangements available on request

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

72
Housings, frames & special applications

Camfil Farr Solutions


Filter Housing

FCBS-HF

Advantages
• Easy to Install • Gasket to seal between door

Pre-Filtration, Class G3 to F5
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design

Housing: Galvanised steel.


Filters: S-FLO-W, HI-CAP, Hi-FLO and OPAKFIL G.
Alternative: Possibility to switch the housings 180º (flexibility to access from left or right side).
Please note: Stainless steel version is also available.

Bag and Compact Filters,


Class F5 to F9
W D

Number of Number of
Exterior dimensions Interior dimensions filters Unit Unit

H E PA / U L PA F i l t e r s , C l a s s
Reference Type Model 592x592 filters 287x592 volume
(WxHxD) mm (WxH) mm m³ weight kg
mm mm
613002020 FCBS-HF 0510 05 10 399×744×500 309×614 _ 1 0.15 18

H10 to U17
613002040 FCBS-HF 1005 10 05 704×439×500 614×309 - 1 0.16 18
613002050 FCBS-HF 1010 10 10 704×744×500 614×614 1 - 0.27 24
613002060 FCBS-HF 1015 10 15 704×1055×500 614×925 1 1 0.38 38
613002070 FCBS-HF 1020 10 20 704×1360×500 614×1230 2 - 0.49 42
613002080 FCBS-HF 1025 10 25 704×1670×500 614×1540 2 1 0.6 54
613002090 FCBS-HF 1030 10 30 704×1975×500 614×1845 3 - 0.71 62

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

613002100 FCBS-HF 1510 15 10 1013×744×500 923×614 1 1 0.39 33


613002110 FCBS-HF 1520 15 20 1013×1360×500 923×1230 2 2 0.7 57
613002120 FCBS-HF 1530 15 30 1013×1975×500 923×1845 3 3 1.03 80
613002130 FCBS-HF 2010 2010 1318×744×500 1228×614 2 - 0.5 38
613002140 FCBS-HF 2015 20 15 1318×1055×500 1228×925 2 2 0.71 62
613002150 FCBS-HF 2020 20 20 1318×1360×500 1228×1228 4 - 0.92 65
613002160 FCBS-HF 2025 20 25 1318×1670×500 1228×1540 4 2 1.13 86
613002170 FCBS-HF 2030 20 30 1318×1975×500 1228×1845 6 - 1.33 92
613002180 FCBS-HF 2510 25 10 1677×744×500 1537×614 2 0.64 47
Filter Frames and Housings

613002190 FCBS-HF 2520 25 20 1677×1360×500 1537×1230 4 2 1.17 81


613002200 FCBS-HF 2530 25 30 1677×1975×500 1537×1845 6 3 1.7 114
613002210 FCBS-HF 3010 30 10 1982×744×500 1842×614 3 - 0.76 54
613002220 FCBS-HF 3015 30 15 1982×1055×500 1842×925 3 3 1.07 81
613002230 FCBS-HF 3020 30 20 1982×1360×500 1842×1230 6 - 1.38 89
613002240 FCBS-HF 3025 30 25 1982×1670×500 1842×1540 6 3 1.7 118
613002250 FCBS-HF 3030 30 30 1982×1975×500 1842×1842 9 - 2 126
Other dimensions and arrangements available on request
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

73
Housings, frames & special applications

Filter Housing

FCBS-A

Advantages
• Easy to Install • Gasket to seal between door
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design

Housing: Galvanised steel.


Filters: Absolute, AIROPAC, MICRETAIN and SOFILAIR.
Alternative: Possibility to switch the housings 180º (flexibility to access from left or right side).
Please note: Stainless steel version is also available.

W D

Interior Number of Number


Exterior dimensions Unit Unit
Reference Type Model dimensions WxH filters 592x592 of filters
(WxHxD) mm volume m³ weight kg
mm mm 287x592 mm
605003520 FCBS-A 0510 05 10 399×744×500 309×614 - 1 0.15 20
605003540 FCBS-A 1005 10 05 704×439×500 614×309 - 1 0.16 20
605003550 FCBS-A 1010 10 10 704×744×500 614×614 1 - 0.27 26
605003560 FCBS-A 1015 10 15 704×1055×500 614×925 1 1 0.38 41
605003570 FCBS-A 1020 10 20 704×1360×500 614×1230 2 - 0.49 46

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
605003580 FCBS-A 1025 10 25 704×1670×500 614×1540 2 0,6 59
605003590 FCBS-A 1030 10 30 704×1975×500 614×1845 3 - 0.71 68
605003600 FCBS-A 1510 15 10 1013×744×500 923×614 1 0.39 37
605003610 FCBS-A 1520 15 20 1013×1360×500 923×1230 2 2 0,7 62
605003620 FCBS-A 1530 15 30 1013×1975×500 923×1845 3 3 1.03 88
605003630 FCBS-A 2010 20 10 1318×744×500 1228×614 2 - 0,5 42
605003640 FCBS-A 2015 20 15 1318×1055×500 1228×925 2 2 0.71 68
605003650 FCBS-A 2020 20 20 1318×1360×500 1228×1228 4 - 0.92 72
605003660 FCBS-A 2025 20 25 1318×1670×500 1228×1540 4 2 1.13 95
605003670 FCBS-A 2030 20 30 1318×1975×500 1228×1845 6 - 1.33 101
605003680 FCBS-A 2510 25 10 1677×744×500 1537×614 2 1 0.64 51
605003690 FCBS-A 2520 25 20 1677×1360×500 1537×1230 4 2 1.17 89
605003700 FCBS-A 2530 25 30 1677×1975×500 1537×1845 6 3 1.7 126
605003710 FCBS-A 3010 30 10 1982×744×500 1842×614 3 - 0.76 59
605003720 FCBS-A 3015 30 15 1982×1055×500 1842×925 3 3 1.07 89
605003730 FCBS-A 3020 30 20 1982×1360×500 1842×1230 6 - 1.38 98
605003740 FCBS-A 3025 30 25 1982×1670×500 1842×1540 6 3 1.7 130
605003750 FCBS-A 3030 30 30 1982×1975×500 1842×1842 9 - 2 138
Other dimensions and arrangements available on request

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

74
Housings, frames & special applications

Camfil Farr Solutions


Filter Housing

FCBL-CC

Advantages
• Easy to Install • Easy servicing

Pre-Filtration, Class G3 to F5
• No tools needed to change • Stable and secure design
filters • Modular construction
• Gasket to seal between door
and filter housing

Housing: Galvanised steel.


Filters: Carbon cylinders 1000, 2000 or 2600.
Carbon CM05: For odours and VOC’s.
Carbon CM07: For gases as H2S, SO2, NH3.
Alternative: Possibility to switch the housings 180º (flexibility to access from left or right side).

Bag and Compact Filters,


Please note: Stainless steel version is also available

Class F5 to F9
W D

H E PA / U L PA F i l t e r s , C l a s s
Unit
Exterior dimensions (WxHxD) Interior dimension (WxH) Number of Unit weight
Reference Type Model volume
mm mm cylinders kg

H10 to U17

607002020 FCBL-CC 0510 05 10 399×744×750 309×610 8 0.23 25.5
607002040 FCBL-CC 1005 10 05 704×439×750 614×309 8 0.24 25.5
607002050 FCBL-CC 1010 10 10 704×744×750 614×614 16 0.4 33
607002060 FCBL-CC 1015 10 15 704×1055×750 614×925 24 0.57 49.5
607002070 FCBL-CC 1020 10 20 704×1360×750 614×1230 32 0.73 58.5

Carbon and Chemical Filters


607002080 FCBL-CC 1025 10 25 704×1670×750 614×1540 40 0.9 75
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

607002090 FCBL-CC 1030 10 30 704×1975×750 614×1845 48 1.06 82.5


607002100 FCBL-CC 1510 15 10 1013×744×750 923×614 24 0.58 45
607002110 FCBL-CC 1520 15 20 1013×1360×750 923×1230 48 1.05 75
607002120 FCBL-CC 1530 15 30 1013×1975×750 923×1845 72 1.53 110
607002130 FCBL-CC 2010 20 10 1318×744×750 1228×614 32 0.75 53
607002140 FCBL-CC 2015 20 15 1318×1055×750 1228×925 48 1.06 80.5
607002150 FCBL-CC 2020 20 20 1318×1360×750 1228×1228 64 1.37 91.5
607002160 FCBL-CC 2025 20 25 1318×1670×750 1228×1540 80 1.68 118
Filter Frames and Housings

607002170 FCBL-CC 2030 20 30 1318×1975×750 1228×1845 96 1.99 128.5


607002180 FCBL-CC 2510 25 10 1677×744×750 1537×614 40 0.95 65
607002190 FCBL-CC 2520 25 20 1677×1360×750 1537×1230 80 1.74 111
607002200 FCBL-CC 2530 25 30 1677×1975×750 1537×1845 120 2.53 157.5
607002210 FCBL-CC 3010 30 10 1982×744×750 1842×614 48 1.13 72.5
607002220 FCBL-CC 3015 30 15 1982×1055×750 1842×925 72 1.6 111
607002230 FCBL-CC 3020 30 20 1982×1360×750 1842×1230 96 2.06 124.5
607002240 FCBL-CC 3025 30 25 1982×1670×750 1842×1540 120 2.53 161.5
607002250 FCBL-CC 3030 30 30 1982×1975×750 1842×1842 144 2.99 175
Other dimensions and arrangements available on request
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

75
Housings, frames & special applications

Filter Housing

FCBL-CS

Advantages
• Easy to Install • Gasket to seal between door
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design

Housing: Galvanised steel.


Filter: Bonded and Granular Carbon Panels.
Standard Carbon: For odours and VOC’s.
Impregnated Carbon: For gases as H2S, SO2, NH3.
Alternative: Possibility to switch the housings to 180º (flexibility to access from left or right
side).
Please note: Stainless steel version is also available.

W D

Exterior dimensions (WxHxD) Interior dimensions (WxH) Number of Carbon Unit volume Unit weight
Reference Type Model mm mm panels m3 kg
611002040 FCBL-CS 1005 10 05 704x439x750 614x309 3 0.24 25.0
611002050 FCBL-CS 1010 10 10 704x744x750 614x614 6 0.40 32.5
611002060 FCBL-CS 1015 10 15 704x1055x750 614x925 9 0.57 51.5
611002070 FCBL-CS 1020 10 20 704x1360x750 614x1230 12 0.73 57.5
611002080 FCBL-CS 1025 10 25 704x1670x750 614x1540 15 0.90 73.5

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
611002090 FCBL-CS 1030 10 30 704x1975x750 614x1845 18 1.06 85.0
611002130 FCBL-CS 2010 20 10 1318x744x750 1228x614 12 0.75 51.5
611002140 FCBL-CS 2015 20 15 1318x1055x750 1228x925 18 1.06 84.0
611002150 FCBL-CS 2020 20 20 1318x1360x750 1228x1228 24 1.37 89.0
611002160 FCBL-CS 2025 20 25 1318x1670x750 1228x1540 30 1.68 117.5
611002170 FCBL-CS 2030 20 30 1318x1975x750 1228x1845 36 1.99 126.0
611002210 FCBL-CS 3010 30 10 1982x744x750 1842x614 18 1.13 73.5
611002220 FCBL-CS 3015 30 15 1982x1055x750 1842x925 21 1.60 111.0
611002230 FCBL-CS 3020 30 20 1982x1360x750 1842x1230 36 2.06 121.5
611002240 FCBL-CS 3025 30 25 1982x1670x750 1842x1540 45 2.53 162.0
611002250 FCBL-CS 3030 30 30 1982x1975x750 1842x1845 54 2.99 172.0
Other dimensions and arrangements available on request

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

76
Housings, frames & special applications

Camfil Farr Solutions


Filter Housing

FCBL-HF

Advantages
• Easy to Install • Gasket to seal between door

Pre-Filtration, Class G3 to F5
• Modular construction and filter housing
• No tools needed to change • Easy servicing
filters • Stable and secure design

Housing: Galvinised steel.


Filter: S-FLO-W, HI-FLO and HI-CAP.
Alternative: Possibility to switch the housings 180° (flexibility to access from left or right side).
Please note: Stainless steel version is also available.

Bag and Compact Filters,


Class F5 to F9
W D

H E PA / U L PA F i l t e r s , C l a s s
Interior Unit
Exterior dimensions dimensions (WxH) Number of filter Number of filter Unit

H10 to U17
Reference Type Model (WxHxD) mm mm 592x592 mm 287x592 mm weight kg volume m3

613003020 FCBL-HF 0510 05 10 399x744x750 309x614 - 1 25 0.23


613003040 FCBL-HF 1005 10 05 704x439x750 614x309 - 1 25 0.24
613003050 FCBL-HF 1010 10 10 704x744x750 614x614 1 - 32.5 0.4
613003060 FCBL-HF 1015 10 15 704x1055x750 614x925 1 1 51.5 0.57
613003070 FCBL-HF 1020 10 20 704x1360x750 614x1230 2 - 57.5 0.73

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

613003080 FCBL-HF 1025 10 25 704x1670x750 614x1540 2 1 73.5 0.9


613003090 FCBL-HF 1030 10 30 704x1975x750 614x1845 3 - 85 1.06
613003100 FCBL-HF 1510 15 10 1013x744x750 923x614 1 1 45 0.58
613003110 FCBL-HF 1520 15 20 1013x1360x750 923x1230 2 2 77.5 1.05
613003120 FCBL-HF 1530 15 30 1013x1975x750 923x1845 3 3 110 1.53
613003130 FCBL-HF 2010 20 10 1318x744x750 1228x614 2 - 51.5 0.75
613003140 FCBL-HF 2015 20 15 1318x1055x750 1228x925 2 2 84 1.06
613003150 FCBL-HF 2020 20 20 1318x1360x750 1228x1228 4 - 89 1.37
Filter Frames and Housings

613003160 FCBL-HF 2025 20 25 1318x1670x750 1228x1540 4 2 117.5 1.68


613003170 FCBL-HF 2030 20 30 1318x1975x750 1228x1845 6 - 126 1.99
613003180 FCBL-HF 2510 25 10 1677x744x750 1537x614 2 1 64 0.95
613003190 FCBL-HF 2520 25 20 1677x1360x750 1537x1230 4 2 110 1.74
613003200 FCBL-HF 2530 25 30 1677x1975x750 1537x1845 6 3 156 2.53
613003210 FCBL-HF 3010 30 10 1982x744x750 1842x614 3 - 73.5 1.13
613003220 FCBL-HF 3015 30 15 1982x1055x750 1842x925 3 3 111 1.6
613003230 FCBL-HF 3020 30 20 1982x1360x750 1842x1230 6 - 121.5 2.06
613003240 FCBL-HF 3025 30 25 1982x1670x750 1842x1540 6 3 162 2.53
613003250 FCBL-HF 3030 30 30 1982x1975x750 1842x1842 9 - 172 2.99
A i r F i l t e r Te c h n o l o g y

Other dimensions and arrangements available on request.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

77
Housings, frames & special applications

Te r m i n a l F i l t e r H o u s i n g s

Pharmaseal

Advantages
• Combines all the essential • Fully welded seams
functions required for • Controls and connections
pharmaceutical and accessible from room side
biotechnology facilities
• Capability to isolate the room
• Quick filter change during filter change

Application: Turbulent airflow clean rooms in pharmaceutical and bio-pharma.


Type: Terminal filter ducted ceiling exhaust housing for HEPA/ULPA filters in clean rooms, gel
seal, with individual bubble tight damper.
Construction: 1.6mm aluminium, continuously welded.
Duct connection: Round, fully welded ribbed inlet on top 305 diameter.
Damper: Individual adjustable bubble tight damper for airflow adjustment and hood bubble tight
isolation.
Included functions: Static pressure port.
Damper control with damper position indicator.
Overall efficiency test: downstream sample port.
Ports: Chrome-plates brass quick disconnect.
W
For filters: MEGALAM HFU H14 or U15 gel seal MD, MX and MG depth.
D
Filter seal: Immediate airtight seal by knife edge technology and gel seal filters.
Filter mounting: Quick filter change by pre-positioned rotating clamps.
Controls: Individual MPPS scanning, EN 1822 individual test report in the box.
Fastening: Suspended or fixed by 4 hanging pads.
Grille: Stainless steel 304 flush perforated hinged grille, 40% open with 38mm removable trim.

Supply Unit
With simplified control set: static pressure port, damper control, no aerosol dispersion port

Dimensions (WxHxD)
Reference Type Model Unit weight kg Unit volume m 3
mm
5502.03.12 Pharmaseal 6P6 PH-25D25D-12D-D-F-12-R-TS-A-C-2-D-2-A-2 641x641x311/305 13 0,17
5502.05.12 Pharmaseal 12P6 PH-25D49D-12D-D-F-12-R-TS-A-C-2-D-2-A-2 641x1251x311/305 25 0,34

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Exhaust Unit
With complete control set: static pressure port, damper control, overall efficiency port

Dimensions (WxHxD)
Reference Type Model Unit weight kg Unit volume m 3
mm
5502.03.50 Pharmaseal 6P6 PH-25D25D-12D-D-F-12-R-TS-A-C-0-C-2-A-2 641x641x311/305 13 0,17
5502.05.50 Pharmaseal 12P6 PH-25D49D-12D-D-F-12-R-TS-A-C-0-C-2-A-2 641x1251x311/305 25 0,34

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

78
Housings, frames & special applications

Camfil Farr Solutions


Filter Containment Systems

Camsafe

Advantages
• Contact free filter change • Sealed, welded, solid design

Pre-Filtration, Class G3 to F5
• Automatic tension regulating • Tightness class B as per EN
filter clamping device 1866 at 5000 Pa
• Fast secure filter installation, • Ready flanged
lever operated • CamSafe connecting pieces can
• Optional filter seal seating test be supplied in various designs
as per DIN 1946, Part 4

W D Application: CamSafe chambers are used when filtering radioactive, toxic or bacterial particles
and gasses and provide maximum safety for the operator. Areas of use include laboratories,
isolation wards and the pharmaceutical industry. The casings can be joined together so that

Bag and Compact Filters,


multi-stage filter systems with a volume flow of up to 24,000 m3/h can be achieved.
Epoxy coated casing: Epoxy resin coating in RAL 9010 which is capable of being

Class F5 to F9
decontaminated, clamping device made from high grade steel 1.4301.
Steel casing: Manufactured in high grade steel 1.4301.
Standard design: Material thickness 2mm, flange drilled ready for operation, service cover
with male thread hand knobs, changing bag, support shelf for contact free filter changing,
automative tension regulating filter clamping device.
Options: Filter seal seating test device in accordance with DIN 1946 Part 4, pressure
compensation device and pressure check points.
Filter cartridges:
Prefilter P1: 610x610x47mm .

H E PA / U L PA F i l t e r s , C l a s s
Prefilter P2: 610x610x292mm.
Main filter: 610x610x292mm.

H10 to U17
All main filters come equipped with straps to aid the handling, enabling them to be changed
easily.
The filters can be supplied with a variety of gaskets to suit the application.
The casing is suitable for different classes of filter, suitable for dealing with glasses or particle
contamination.
Accessories: Safe change bags, manometers and material for the flanged joints supplied on
request.

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Dimensions prefilter Dimensions second filter


Reference Type Dimensions (WxHxD*) mm (WxHxD) mm (WxHxD) mm Unit weight kg Unit volume m3

518010 Camsafe 1000, painted 730x535x725 (+ 90*) - 610x610x292 50 0,35


518014 Camsafe P1/1000, painted 730x790x725 (+ 90*) 610x610x47 610x610x292 80 0,55
518018 Camsafe P2/1000, painted 730x1020x725 (+ 90*) 610x610x292 610x610x292 90 0,7
5180101 Camsafe 1000 1.4301 730x535x725 (+ 90*) - 610x610x292 50 0,35
5180141 Camsafe P1/1000 1.4301 730x790x725 (+ 90*) 610x610x47 610x610x292 80 0,35
5180181 Camsafe P2/1000 1.4301 730x1020x725 (+ 90*) 610x610x292 610x610x292 90 0,7
* incl. male thread hand knobs + 90mm. Allow access of approximately 1m to change the filter.
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

79
Housings, frames & special applications

F i l t e r s f o r H i g h Te m p e r a t u r e

Termikfil 2000

Advantages
• Meets FDA requirements - • Exclusive precuring process
continuous 350°C, 99,99% at at 300°C carried out in the
0,3 μm plant
• Efficiency tested after • Ceramic frame
precuring

Application: Protection of ultra-clean processes at high temperature, sterilisation tunnels in the


pharmaceutical industry.
Type: Very high efficiency panel resistant to 350°C in continuous service.
Frame: Composite ceramic.
Gasket: Rolled glass fibre paper + 6mm dia glass braid.
Media: Glass fibre.
Separator: Glass strands.
W
Sealant: Ceramic.
D
Grid: Upstream and downstream in stainless steel.
DOP efficiency: ≥ 99.99%.
Authorised local penetration: 10 -4 maximum, (0.01% conforming to FDA).
Recommended final pressure drop: 350 Pa.
Temperature: Up to 350°C in continous service.
Test: 100% after thermal treatment at 300°C.
Mounting: A stainless steel compensating frame can be supplied to reach the thickness of
150mm or 292mm.
NB: To reduce fume emission when starting up, TERMIKFIL undergoes a specific precuring
cycle in the factory at 300°C using an exclusive CAMFIL FARR process.

Dimensions Media Air flow/pressure Unit Unit


References Filter classification
Type Model (WxHxD) weight
mm EN 1822 area m 2 drop m 3 /h/Pa kg volume m 3

3415.07.00 TERMIKFIL 4P4 457x457x84 99.9 5.0 675/250 3 0.04


3415.06.00 TERMIKFIL 3P3 305x305x84 99.9 2.9 300/250 2 0.01
3415.01.00 TERMIKFIL 3P6 305x610x84 99.9 5.9 600/250 4 0.02

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
3415.02.00 TERMIKFIL 6P6 610x610x84 99.9 12.1 1200/250 5 0.04
3415.05.00 TERMIKFIL 4P6 457x610x84 99.9 8.9 900/250 4 0.03
3415.03.00 TERMIKFIL 7P6 762x610x84 99.9 15.3 1500/250 6 0.05
3415.04.00 TERMIKFIL 9P6 915x610x84 99.9 18.5 1800/250 8 0.06

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

80
Housings, frames & special applications

Camfil Farr Solutions


F i l t e r s f o r H i g h Te m p e r a t u r e

Absolute ® 1FRK

Advantages
• 99.97% DOP • High temperature resistant (up

Pre-Filtration, Class G3 to F5
to 350°C)

Application: Protection of ultra-clean processes at high temperatures.


Frame: Stainless steel.
Gasket: Glass fibre.
Media: Glass fibre paper.
Separator: Aluminium.
Sealant: Ceramic, glass fibre.
DOP efficiency: 99.97% .
Temperature: 350°C in continuous service (400°C peak).

Bag and Compact Filters,


Class F5 to F9
W D

Dimensions Filter Unit


Media Air flow/nominal Unit weight
Reference Type Model (WxHxD) classification volume
area m 2 pressure drop m 3 /h/Pa kg
mm EN 779:2002 m3
213612F2 Absolute 1 FRK 1FRK-220-10 305x610x150 99.97 5.1 580/250 6 0.04
213024F1 Absolute 1 FRK 1FRK-300-10 457x457x150 99.97 6.8 1125/250 8 0.05

H E PA / U L PA F i l t e r s , C l a s s
213014F2 Absolute 1 FRK 1FRK-150-10 457x610x150 99.97 8.0 900/250 10 0.07
213017F2 Absolute 1 FRK 1FRK-600-10 610x610x150 99.97 11.0 1245/250 12 0.07

H10 to U17
213019F2 Absolute 1 FRK 1FRK-980-01 914x610x150 99.97 16.8 1925/250 16 0.11
213003F2 Absolute 1 FRK 1FRK-450-01 305x610x150 99.97 10.4 950/250 9 0.06
213021F2 Absolute 1 FRK 1FRK-725-01 610x457x292 99.97 16.4 1500/250 13 0.08
213010F1 Absolute 1 FRK 1FRK-1250-01 762x610x292 99.97 28.4 2625/250 21 0.17
213008F2 Absolute 1 FRK 1FRK-1000-01 610x610x292 99.97 22.5 2050/250 17 0.12
Model 01 = seal on air inlet side - Model 02 = seal on air outlet side - Other dimensions available on request

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

81
Housings, frames & special applications

Filters for Painting Booths

Paint Extract Filters

Advantages
• Long lasting solution • Effective for a variety of
• Collapsible for transportation contaminants

Application: Collection of overspray particles, paint booth exhaust


Type: Concertina pleated cardboard filter
Case: Cardboard
Media: Cardboard or two stage cardboard and synthetic media
Efficiency: See table
Recommended final pressure drop: 130 Pa (suggested economical change point)
Temperature: 180°C maximum in continuous service (standard grade) 100°C maximum in
continuous service (two stage grades)
TIFICAT
ER
E
C

EN 779:2002
IN

D
IE
DI

VI F
DU TI
ALLY CER

Reference Type Model Dimensions (WxL) m Air flow/ Pressure drop m 3 /hr/Pa Unit weight kg
AND 1 Standard AND 1 - 3 x 30 0.9 x 9.15 2700 / 30 9.80
AF Basic Standard AF Basic 3 x 30 0.9 x 9.15 2700 / 30 9.80
HEF 1330 Two Stage HEF 1330 - 3 x 30 0.9 x 9.15 2700 / 40 11.20

Performance data Standard type Two stage type


Paint type Filtration efficiency (%) Holding capacity (kg) Filtration efficiency (%) Holding capacity (kg)
High Solids 97.0 - 98.1 14 - 18 98.75 - 99.1 16 - 24
Bake Enamel 93.0 - 94.5 6 - 11 97.8 - 91.15 7 - 14
Fast Dry Enamel 96.0 - 96.9 3-4 98.0 - 92.2 4-6
Two Component Epoxy 91.0 - 93.5 5-8 n/a n/a

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

82
Housings, frames & special applications

Camfil Farr Solutions


Filters for Painting Booths

Airopac ® HT-HF

Advantages
• High efficiency • Silicon free construction

Pre-Filtration, Class G3 to F5
• High temperature • Compact design

Application: Paint bake ovens.


Type: High efficiency, high temperature, silicon free compact filter.
Frame: Galvanised steel.
Gasket: Glass fibre.
Media: Glass fibre paper.
Separator: Corrugated aluminium.
Sealant: Glass fibre .
Grid: Galvanised steel grille upstream and downstream.

Bag and Compact Filters,


ER
TIFICAT EN 779:2002 efficiency: F6, F8.
E
C

EN 779:2002 Opacimetric efficiency: > 60%, >90%.

Class F5 to F9
IN

W
IE
DI

Recommended final pressure drop: 300 Pa.


VI F
TI
D
DU
ALLY CER

Temperature: 220°C maximum continuous, 250°C peak during 1 hour.

Dimensions Filter classification Media Air flow/nominal Unit unit


Reference Model (WxHxD) mm EN 779:2002 surface m 2 pressure drop m 3 /h/Pa weight kg volume m 3
1519.77.03 3CPMHT-HF-242412-60 592x592x292 F6 13.3 3600/110 9 0.10
1520.27.03 3CPMHT-HF-242412-90 592x592x292 F8 13.3 3600/155 9 0.10

H E PA / U L PA F i l t e r s , C l a s s
Other dimensions available on request.
Also available in version without flange, for more information please contact us.

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

83
Housings, frames & special applications

Filters for Painting Booths

Panolair SSI - Micretain H10

Advantages
• Compact design • Guaranteed silicone free
• Meets the requirements of the • Very high efficiency H10
surface treatment industry

Application: Final filtration in painting booths.


Type: High efficiency pleated paper filter.
Case: Anodised aluminium extrusion.
Media: Glass fibre.
Sealant: Polyurethane.
Separator: Strips of glass paper.
Grid: Painted steel grilles upstream and downstream.
EN 1822 efficiency: H10.
MPPS efficiency: ≥ 85%.
Efficiency DOP 0.3μ: ≥ 95%.
Temperature: 70°C in continuous service.
TIFICAT
ER
Holding frames: Mechanical clamping structure, terminal diffusers.
E
C

EN 779:2002
IN

D
IE
DI

W
VI F
DU TI

D
ALLY CER

Dimensions Filter classification Media Airflow / pressure Unit Unit


Reference Type Model (WxHxD) mm EN 1822 area m 2 drop / m 3 /h/Pa weight kg volume m 3
3409.48.00 Panolair Micretain 0.3 m/s 610x1285x44 H10 8.1 1000/110 8.0 0.04
3409.73.00 Panolair Micretain 0.5 m/s 610x610x44 H10 5.2 650/120 4.0 0.02
3409.31.00 Panolair Micretain 0.5 m/s 610x1220x44 H10 10.5 1200/120 6.5 0.04
3409.45.00 Panolair Micretain 0.5 m/s 610x1285x44 H10 11.1 1500/120 8.0 0.04
Other sizes available on request .
Also available in F8 and F9 grades.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

84
Housings, frames & special applications

Camfil Farr Solutions


Filters for Painting Booths

CDM Media

Advantages
• Thermal bonded polyester fibre • Enhances laminar air flow

Pre-Filtration, Class G3 to F5
• Treated with special adhesive to patterns
prevent dust loss due to • Non toxic
vibration

Application: For fine filtration in air conditioning devices and installations, particularly final
filtration in Automotive spraybooths and drying cabinets.
Flammability: (DIN 53438) F1 self extinguishing.
Colour: White.
Media: Synthetic.
EN 779:2002 efficiency: F5.

Bag and Compact Filters,


ER
TIFICAT
Arrestance efficiency: 95%.
E
C

EN 779:2002 Temperature: 80°C - 100°C maximum in continuous service.


IN

D
IE
DI

VI

Class F5 to F9
F
TI
Humidity: 80 - 100% RH.
DU
ALLY CER

Filter Media Dust Unit Rear


Dimensions Velocity/pressure drop
Reference Type Model classification holding support
(meters) EN 779:2002 area m 2 m/s/Pa g/m² volume m3 scrim
TA500220 Roll TA-500 2.0 x 20 F5 40 0.25 / 54 223 0.53 no
TA500120 Roll TA-500 1.0 x 20 F5 20 0.25 / 54 223 0.26 no

H E PA / U L PA F i l t e r s , C l a s s
TA600GI220 Roll TA-600 GI 2.0 x 20 F5 40 0.25 / 45 291 0.82 yes
TA600GI1620 Roll TA-600 GI 1.6 x 20 F5 32 0.25 / 45 291 0.4 yes

H10 to U17
TA600GI120 Roll TA-600 GI 1.0 x 20 F5 20 0.25 / 45 291 0.304 yes
SPEU480220 Roll SPEU-480 2.0 x 20 F5 40 0.25 / 23 399 0.615 yes
Other sizes and cut pads available on request.

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

85
Housings, frames & special applications

F i l t e r s f o r G a s Tu r b i n e s

Cam GT ®

Advantages
• Suitable for high humidity • Very robust construction
conditions • Corrosion resistant
• Burst pressure 7500 Pa • Can be used to upgrade existing
• Patented draining pleating installations

Application: Air intake for gas turbines, compressors and large engines.
Type: High efficiency, incinerable compact filter.
Frame: Polypropylene and ABS.
Gasket: Expanded polyurethane placed on the downstream side (code 01).
Media: Glass fibre paper.
Separator: Hot-melt beads.
Sealant: Polyurethane.
Grid: Glass fibre reinforcement grid placed downstream.
W D
EN 779:2002 efficiency: F7. F9.
EN 1822 efficiency: H10.
Recommended final pressure drop: 600 Pa.
Temperature: 80°C maximum in continuous service.
N.B: Burst pressure: > 7500 Pa.

EFFICIENCY
GUARANTEE

Dimensions Filter classification Media Air flow/pressure drop Unit weight Unit Volume Energy
Reference Unit Type Model (WxHxD) mm EN 779:2002 area m² m³/h/Pa kg m³ Rating

1530.12.50 CAM GT-F7 CAM GT F7-242412/01 592x592x290 F7 19 4250/120 7 0.11 B


1530.17.50 CAM GT-F9 CAM GT F9-242412/01 592x592x290 F9 19 4250/160 7 0.11 B
1530.18.50 CAM GT-H10 CAM GT H10-242412/01 592x592x290 H10 19 4250/230 7 0.11
1530.52.50 CAM GT-F7 CAM GT F7-241212/01 592x287x290 F7 9 2125/145 5 0.05 B
1530.57.50 CAM GT-F9 CAM GT F9-241212/01 592x287x290 F9 9 2125/180 5 0.05 B

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
1530.58.50 CAM GT-H10 CAM GT H10-241212/01 592x287x290 H10 9 2125/250 5 0.05
Available with gasket on upstream side (10). Available in reverse flow version.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

86
Housings, frames & special applications

Camfil Farr Solutions


F i l t e r s f o r G a s Tu r b i n e s

Campulse EF

Advantages
• Specially designed for very • Air intake for gas turbines,

Pre-Filtration, Class G3 to F5
dusty environments compressors and large engines
• Desert and arctic environments

Type: Single stage, high efficiency Pulse filter cartridge.


End Caps: Galvanised steel.
Liners: Expanded galvanised steel.
Media: Resin impregnated mixture of cellulose and synthetic fibres.
Separator: Hot melt beads.
Seal: Adhesive bonding layer.
Gasket: Closed cell neoprene or equivalent.

Bag and Compact Filters,


Eurovent 4/9 efficiency: F9.
TIFICAT
Recommended final pressure drop: 1000 Pa.
ER

Class F5 to F9
E
C

EN 779:2002 Recommended air flow per set of cartridges CY-2612/CO-2612: 2500 m3/h.
IN

Temperature: 80°C max.


IE
DI

VI I F
DU RT
ALLY CE

Degradation pressure: 10kPa.

Dimensions Shipping data


Model mm Media area Air flow/Pressure drop m 3 /h/Pa Filter classification
m 3 / Kg
CY-2612 660 324 21.40 1062/211 F9 0.076 7

H E PA / U L PA F i l t e r s , C l a s s
CO-2612 660 445/324 25.41 1261/211 F9 0.142 9

H10 to U17
Carbon and Chemical Filters
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Filter Frames and Housings


A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

87
Housings, frames & special applications

F i l t e r s f o r G a s Tu r b i n e s

Hi-Flo ® T

Advantages
• Reinforced filter media • Rigid design concept
• Suitable for turbulent air flow • High burst strength
conditions

Application: Turbo machinery.


Type: Multi pocket high efficiency bag filter.
Frame: 25mm thick steel header frame.
Media: Glass fibre.
EN 779:2002 efficiency: F6, F7, F8.
Arrestance efficiency: 55-65%, 80-85%, 90-95%.
Temperature: 70°C maximum in continuous service.
Humidity: 100% RH.
Burst Pressure: ~3000 Pa.
W D

EFFICIENCY
GUARANTEE

Dimensions Media area Air flow / pressure drop Unit weight


Filter classification
Reference Type Model (WxHxD) Unit Volume m 3
mm EN 779:2002 m2 m 3 /hr/Pa kg

538012A1 Hi-Flo T 3 XMT-65 592x592x655 F6 7.8 3400/70 5.0 0.05


538013A1 Hi-Flo T 3 ZMT-65 287x592x655 F6 3.9 1700/70 3.0 0.03
538012A2 Hi-Flo T 3 XMT-85 592x592x655 F7 7.8 3400/90 5.0 0.05
538013A2 Hi-Flo T 3 ZMT-85 287x592x655 F7 3.9 1700/90 3.0 0.03

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
538012A3 Hi-Flo T 3 XMT-95 592x592x655 F8 7.8 3400/115 5.0 0.05
538013A3 Hi-Flo T 3 ZMT-95 287x592x655 F8 3.9 1700/115 3.0 0.03
Other dimensions available on request.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

88
Housings, frames & special applications

Camfil Farr Solutions


Dust Collector

Gold Series

Advantages
• High collector efficiency using • Modular design for optimum

Pre-Filtration, Class G3 to F5
HemiPleat cartridges flexibility
• Up to 25% smaller • Easy to install and maintain
• Customised for Original • Simple cartridge replacement
Equipment Manufacturers using quick release cam bars
(OEM)

Application: Gold Series cartridge dust and fume collectors may be used for a wide range of
pollution control and product recovery applications.
Type: Pulse cleaning, cartridge based dust collector with high performance filter elements.
Cleaning is accomplished by pulse waves that emanate from the centre of the filter providing

Bag and Compact Filters,


enhanced cleaning for a more efficient operation.
Construction: Strong modular construction using 4.5mm carbon steel for the frame and 3mm

Class F5 to F9
carbon steel for the doors, hopper and panels.
Finish: As standard in a green, durable, corrosion resistant powder coated finish. Alternative
construction and colours are also available.
Options: A wide variety of options are available including: Explosion Venting, Special Inlet
Designs, BIBO (bag in-bag out) for Pharmaceutical Applications, Custom Colours, Stainless
Steel Construction, Alternative Hopper Designs etc. please contact us with your specific
requirements.
Cartridges: Vertically mounted to shed dust readily for efficient cleaning and longer service life.
High filtration efficiency meeting the 5 mg/m3 or less emissions required to re-circulate the air

H E PA / U L PA F i l t e r s , C l a s s
back into the work place on non hazardous dusts.

H10 to U17
Easy Access Door
• No Knobs To Lose or Drop
Powerful Cleaning
• No Threads To Bind
System to Provide
• Mechanically Attached Seal
Long Filter Life
• Heavy 10 gauge Construction
• Lock-Out/Tag-Out Capability

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Easy Changeout
Gold Cone Cartridge with patented
Cambar action that positively seals High Entry Inlet
the cartridges without using Cross flow is created through the filters.
threads or knobs. Eliminates upward “can” velocities associated
with traditional hopper inlets.

Optional Quick Open


View Port in Hopper
Filter Frames and Housings
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

89
Housings, frames & special applications

Dust Collector

HemiPleat Cartridges

Advantages
• High efficiency, 99.999% at • Open pleat spacing to enhance
0.5μ and above cleaning cycle
• Low pressure drop • Easy to install using quick
• Reduced energy cost release cam bars
• Long filter life • Double seal gasket for added
security

Application: HemiPleat cartridges may be used for a wide range of pollution control and
product recovery applications.
Type: Pleated media cartridge with improved pleat spacing and media alignment.
Construction: Vertically mounted to shed dust readily for efficient cleaning and longer service
life. Features a cone in the centre of the cartridge to distribute the air pulse and enhance the
cleaning cycle.
Media: Several different types of filter media, pre-coat materials and over bags are available to
suit specific operating conditions. Please contact us to make this selection.
Efficiency: 99.999% at 0.5μ and above.
Options: Filter cartridge options are available to suit specific operating conditions. These
include Carbon Impregnated, Fire Retardant, Ultra High Efficiency, PTFE, and High Temperature.
Please contact us to make this selection.

Dimensions
Reference Type Model Media Type (dia. x L) mm Media area m 2 Unit weight kg

211497-001 HemiPleat HMPTS325 PolyTech Standard 380 x 1000 30.2 13.6


211497-002 HemiPleat HMPTC325 PolyTech Carbon Impregnated 380 x 1000 30.2 13.6
211497-004 HemiPleat HMPTF325 PolyTech Fire Retardant 380 x 1000 30.2 13.6
211497-005 HemiPleat HMPTU325 Poly Tech Ultra High Efficiency 380 x 1000 30.2 13.6
211497-006 HemiPleat HMPTUF325 Poly Tech Ultra High Efficiency Fire Retardant 380 x 1000 30.2 13.6

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

90
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Notes
Housings, frames & special applications

www.camfilfarr.co.uk
Knowsley Road, Haslingden, Lancashire, BB4 4EG
Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736

91
A i r F i l t e r Te c h n o l o g y Filter Frames and Housings Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s Bag and Compact Filters, Pre-Filtration, Class G3 to F5 Camfil Farr Solutions
H10 to U17 Class F5 to F9
A i r F i l t e r Te c h n o l o g y

Standards, Regulations and Recommendations


Ventilation filters Classification as per Eurovent 4/4
recommendation, NaCI method
Standards
EUROVENT 4/4 Initial efficiency Ei (%) Penetration Pi (%)
Year Reference Type of test Classification
Filter class Limits of filter classes
1968 ASHRAE ARRESTANCE EFFICIENCY
EU 10 95 ≤ Ei < 99.9 5 ≥ Pi > 0.1
1980 EUROVENT 4/5 ARRESTANCE EFFICIENCY EU1 to EU4 - EU5 to EU9
EU 11 99.9 ≤ Ei < 99.97 0.1 ≥ Pi > 0.03
1982 AFNOR NF X 44.012 ARRESTANCE EFFICIENCY
EU 12 99.97 ≤ Ei < 99.99 0.03 ≥ Pi > 0.01
1993 CEN EN 779 ARRESTANCE EFFICIENCY G1 to G4 - F5 to F9
EU 13 99.99 ≤ Ei < 99.999 0.01 ≥ Pi > 0.001
2003 CEN EN 779:2002 ARRESTANCE EFFICIENCY G1 to G4 - F5 to F9
EU 14 99.999 ≤ Ei 0.001 ≥ Pi
The new standard for general ventilation filters Clean rooms
EN 779:2002
Classification of different air qualities required
1. Measurement of filter efficiency using modern particle counting technique
2. The aerosol challenge is DEHS (the same as used with HEPA filters) for manufacture of sterile products
3. Classification based on a particle size of 0.4 μm
Maximum number of particles per m 3 of a size greater than
4. The test includes initiatives to determine the discharged efficiency of filters to or equal to
Max. nbr: of μorganisms per m³
better represent their performance in use. These are shown in Annexe A. 0.5 μm 5 μm 0.5 μm 5 μm (active)
inactive (b) active
Why a new standard? A 3.500 0 3.500 0 <1
B 3.500 0 350,000 2.000 10
Certain types of filter media rely on an electrostatic effect to achieve a high level of
C 350,000 2.000 3.500,000 20,000 100
efficiency whilst promising a low pressure drop for a given air volume.
D 3.500,000 20,000 not defined (c) not defined (c) 200
It is important that users are aware of filters that rely on this electrostatic effect
and are also informed about the degradation in efficiency once the electrostatic Pharmaceutical industry
effect dissipates. Guide to good Manufacturing Practice (2002)
(b) Corresponds approximately to the US Federal Standard 209 E and ISO as
This new test procedure describes in Annexe ’A’ a mechanism that removes the follows: classes A and B to class 100. M 3.5. ISO 5; class C to class 10,000. M
electrostatic effect by treating the filter material with Isopropanol. This discharges 5.5. ISO 7; class D to class 100.000. M 6.5 ISO 8.
the filter and enables the real efficiency to be determined. The average efficiency
of the filters after discharge is recorded on the certificate. Comparison of international classification
Filters are classified based on their performance against particles of 0.4 μm. standards
Filters in Group F must achieve an average efficiency greater than 40%; below this
EN ISO European Union
they are included in Group G. Nbr of part 0.5 μm/ US Fed. Std 209 E 14644-1 France AFNOR NF Pharma industry Nbr of part 0.1
m³ (approx.) 1992 X 44.101 1981 μm/ m³ (approx.)
1996 Guide GMP 1989
- - - ISO 1 - - 10
EN 779:2002 Classification 1 - - - - - 35
4 - - ISO 2 - - 100
EN 779:2002 Average arrestance Am Average efficiency Em EUROVENT 4/5 10 M1 - - - - 350
standard (%) (%) equivalent
35 M 1.5 1 ISO 3 - - 1,000
Filter Filter Filter class limits Filter class 100 M2 - - - - 3,500
group class
G2 65 ≤Am < 80 - EU 2 353 M 2.5 10 ISO 4 - - 10,000
Coarse 1,000 M3 - - - - 35,000
G3 80 ≤Am < 90 - EU 3
(G)* 3,530 M 3.5 100 ISO 5 4,000 A and B 100,000
G4 90 ≤Am - EU 4
10,000 M4 - - - - 350,000
F5 - 40 ≤Em < 60 EU 5
35,300 M 4.5 1.000 ISO 6 - - 1.000,000
F6 - 60 ≤Em < 80 EU 6 100,000 M5 - - - - -
Fine (F)
F7 - 80 ≤Em < 90 EU 7 353,000 M 5.5 10,000 ISO 7 400,000 C -
**

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
F8 - 90 ≤Em < 95 EU 8 1.000,000 M6 - - - - -
F9 - 95 ≤Em EU 9 3.530,000 M 6.5 100,000 ISO 8 4.000,000 D -

Initial efficiency (Ea) : * Ea < 20% ; ** Ea ≥20% 10,000,000 M7 - - - - -

Final pressure drop: * 250 Pa ; ** 450 Pa 35.000,000 - - ISO 9 - - -

Very high efficiency filters Permissible particle levels in different classes of


clean rooms and clean zones
Standards
Maximum permissible concentrations (particles/m³ of air) of particles of a
ISO classification size greater than or equal to the size shown below
Year Reference Type of test Classification CD 14644-1 (1996)
1956 MIL STD 282 DOP 0.3 μm - 0.1 μm 0.2 μm 0.3 μm 0.5 μm 1 μm 5 μm

1972 AFNOR NF X 44.011 Uranine 0.15 μm - ISO 1 10 2 - - - -

1976 EUROVENT 4/4 NaCl 0.65 μm EU10 to EU14 ISO 2 100 24 10 4 x -

HEPA: H10 to H14 ISO 3 1,000 237 102 35 8 -


1995 CEN EN 1822 MPPS 0.1 to 0.2 μm
ULPA: U15 to U17 ISO 4 10,000 2,370 1,020 352 83 -
ISO 5 100,000 23,700 10,200 3,520 832 29
EN 1822 Classification
ISO 6 1.000,000 237,000 102,000 35,200 8,320 293
MPPS integral values MPPS local values
ISO 7 - - - 352,000 83,200 2,930
Minimum Maximum Minimum Maximum
Filter Filter Minimum
efficiency penetration efficiency penetration Minimum ISO 8 - - - 3.520,000 832,000 29,300
group class P.C. P.C.
(%) (%) (%) (%)
ISO 9 - - - 35.200,000 8.320,000 293,000
HEPA (H) H10 85 15 6.7 - - -
H11 95 5 20 - - - C = 10N(0.1/D)2.08 part / m3
H12 99.5 0.5 200 - - -
H13 99.95 0.05 2.000 99.75 0.25 400
H14 99.995 0.005 20,000 99.975 0.025 4.000
ULPA (U) U15 99.9995 0.0005 200,000 99.9975 0.0025 40,000
U16 99.99995 0.00005 2.000,000 99.99975 0.00025 400,000
U17 99.999995 0.000005 20,000,000 99.9999 0.0001 1.000,000
HEPA : High Efficiency Particulate Air (filter)
ULPA : Ultra Low Penetration Air (filter)
P.C. : Purification Coefficient

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

92
A i r F i l t e r Te c h n o l o g y

Camfil Farr Solutions


Standards, Regulations and Recommendations
US Fed Std 209 E (1992) Operating life
Class Limits An air filter’s operating life is not directly proportional to its useful filtering surface.
Class Name 0.1 μm 0.2 μm 0.3 μm 0.5 μm 5 μm It is much better to opt for a model comprising 50% additional surface. This
Volume Units Volume Units Volume Units Volume Units Volume Units
increases its operating life by 100%, not 50%!
S1 English m3 m3 m3 m³ m³ Actual case study
M1 - 350 75.7 30.9 10.0 -
Initial pressure drop at
M 1.5 1 1,240 265 106 35.3 - Filter model Effective filtering surface Operating life*
3 600m³/ h

Pre-Filtration, Class G3 to F5
M2 - 3,500 757 309 100 - Hi-Flo 3P 85 6.5 m2 120 Pa 3.500 hours
M 2.5 10 12,400 2,650 1,060 353 -
Hi-Flo 3M 85 9.4 m2 100 Pa 6.500 hours
M3 - 35,000 7,570 3,090 1,000 -
Gain 3 m2 20 Pa 3.000 hours
M 3.5 100 - 26,500 10,600 3,530 -
+ 86% in operating life
M4 - - 75,700 30,900 10,000 - Conclusion + 46% in surface (x 1.5)** - 17% in energy
(x 1.9)**
M 4.5 1000 - - - 35,300 247
* Determined using the Camfil Farr calculation charts in the Hi-Flo brochure, for an average town
M5 - - - - 100,000 618 environment
M 5.5 10,000 - - - 353,000 2,470 ** factor of increase
M6 - - - - 1.000,000 6,180
Energy costs
M 6.5 100,000 - - - 3.530,000 24,700
Energy consumed by an air filter due to its pressure drop:
M7 - - - - 10,000,000 61,800
particles / m3 = 10M(0.5/d)2 . 2
particles / ft3 = Nc(0.5/d)2 . 2 The Efficiency %

Bag and Compact Filters,


Air-conditioning / Comfort The Penetration %

Class F5 to F9
Air quality of premises with non specific pollution
The Purification coefficient (no units)
Regulatory aspect Recommendations
Labour code / Circular of
application of decrees 84/1093- UNICLIMA Air-conditioning & Health guide (1993) q = flow rate (m3/s)
1094 dated 7/12/1984
dP = pressure drop (Pa)
Labour code Art. R235.2.6 Air-conditioning system inlet: 85% opacimetric (F7
Minimum arrestance according to EN 779:2002) Air-conditioning system
h = operating period (hours)
Fresh air ef = fan efficiency (generally 0.6 to 0.7)
efficiency 90% (G4 according outlet: 90% opacimetric (F8 according to EN
to EN 779:2002) 779:2002)
Labour code Art. R232.5.4 Acronyms and abrivations
Recycled Minimum opacimetric
85% opacimetric (F7 according to EN 779:2002)

H E PA / U L PA F i l t e r s , C l a s s
air efficiency 50% (F5 according AFNOR French standardisation body
to EN 779:2002) American Society of Heating, Refrigerating and Air-conditioning Engineers
ASHRAE
(USA)
FILTER ENGINEERING - Calculations ASPEC Association for prevention and study of contamination (France)

H10 to U17
An air filter’s efficiency is expressed in 3 forms: BSI British Standards Institute
CEN European standardisation body
formulas CETIAT Technical centre for air handing and thermal industries (France)
CNC Condensation Nucleus Counter
q x dP x h
E= = kWh VOC Volatile Organic Compounds
ef x 1000 CSTB Scientific and technical centre for construction (France)
DEHS Di-Etil-Hexil-Sebaçate (= DES = DOS)

Clearly the purification coefficient is the most representative expression for high DIN Deutsches Institut für Normung
levels of filtration. E.g.: DOP Di-Octil-Phtalate

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Efficiency 99.995 % : CE of 20,000 EUROVE


European Committee of Manufacturers of Air Handing Equipment
Efficiency 99.9998% : CE of 500 000 NT
The second filter is 25 times more efficient than the first. Arrest Arrestance efficiency
Nota : I = particle concentration upstream E = particle concentration downstream HEPA High Efficiency Particulate Air (filter)
ISO International Standards Organisation
Conversion table (%) MPPS Most Penetrating Particle Size
Efficienc Purification Opa Opacimetric efficiency
Penetration Purification Coefficient Efficiency Penetration
y Coefficient
ULPA Ultra Low Penetration Air (filter)
95 5 20 99.99 0.01 10,000
UNICLIM
99 1 100 99.995 0.005 20,000 Association for refrigeration equipment and air handing equipment (France)
A
99.5 0.5 200 99.999 0.001 100,000 VTT Technical research centre (Finland)
99.9 0.1 1.000 99.9995 0.0005 200,000 dP Pressure drop
99.95 0.05 2.000 99.9999 0.0001 1.000,000
Filter Frames and Housings

99.97 0.03 3 333 99.99995 0.00005 2.000,000


99.98 0.02 5 000 99.99999 0.00001 10,000,000

Comperative efficiencies
on 1 μm on 0.5 μm
E P PC E P PC
90% ARRESTANCE 10% 90% 1.1 5% 95% 1.05
50% EFFICIENCY 30% 70% 1.4 10% 90% 1.1
65% EFFICIENCY 45% 55% 1.8 25% 75% 1.3
85% EFFICIENCY 85% 15% 6.6 70% 30% 3.3
95% EFFICIENCY 95% 5% 20 90% 10% 10
95% 0.3 μm ≥ 98% < 2% ≥100 ≥98% <2% ≥ 50
E = Efficiency, P = Penetration, PC = Purification Coefficient
A i r F i l t e r Te c h n o l o g y

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

93
A i r F i l t e r Te c h n o l o g y

Standards, Regulations and Recommendations


Conversions EFFICIENCY TESTS (Not all the tests are
Speed
equivalent)
1 m/s = 3.6 km/h 1 km/h = 0.278 m/s 1 ft/min = 0.00508m/s 1 m/s = 196.85 ft/min
MPPS (Most Penetrating Particle Size)
Length
1 mile = 1.609 km 1 km = 0.621 mile 1 yd = 0.914 m 1 m = 1.09 yd
1 ft = 0.305 m 1 m = 3.28 ft 1 in = 25.4 mm 1 mm = 0.039 in 0.1 0.5
0.01 0.05 0.3
1 mm = 1.000 μm 1 μm = 0.001 mm 1 μm = 1.000 nm 1 nm = 0.001 μm
1 μm = 10,000 Å 1 Å = 0.0001 μm
Surface
1 ft² = 0.0929 m² 1 m² = 10.8 ft² 1 in² = 6.45 cm² 1 cm² = 0.155 in²
Volume
1 ft³ = 0.0283 m³ 1 m³ = 35.3 ft³ 1 ft³ = 28.3 litres
Flow rate
1 cfm = 0.472.10 -3 m³/s 1 m³/s = 3 600 m³/h 1 m³/h = 0.278.10 -3 m³/s
1 cfm = 1.699 m³/h 1 m³/s = 2 120 cfm
Weight
1 lb = 0.454 kg 1 kg = 2.20 lb 1 oz = 28.3 g 1 g = 0.0352 oz
Force
1 kgf = 9.80665 N 1 N = 0.102 kgf 1 lbf = 4.45 N 1 N = 0.225 lbf The NaCl test (EUROVENT 4/4) is less demanding than the DOP test, which in turn
Pressure is less demanding than the MPPS test
1 mmCE = 9.81 Pa 1 Pa = 0.102 mmCE 1 kPa = pz 1 kPa = 10.2 g/cm²
1 kg/cm² = 0.980665 bar 1 bar = 1.02 kg/cm² 1 kg/m² = 98.0665 kPa 1 kPa = 0.00987 atm Whitby diagram
1 psi = 6.89 kPa 1 bar = 101325 Pa 1 atm = 101.325 kPa 1 mb = 100 Pa
1 mmCE = 1kg/m² 1 kPa = 0.145 psi 1 Pa = 1 N/m² 1 in w.g. = 254 Pa
Distribution of particles in atmospheric air
Energy
1 kgm = 9.80665 J 1 J = 0.102 kgm 1 cal = 4.184 J 1 J = 0.239 cal
1 kWh = 3.6 MJ 1 MJ = 0.278 kWh 1 Btu = 1.055 kJ 1 J = 0.945.10-3 Btu
Power Number
Nombre (1)
(1) Surface (2)
1 CV = 0.736 1 kW = 1.36 CV 1 kcal/h = 1.16 W 1 W = 0.860 kcal/h
1 Btu/h = 0.292 W 1 W = 3.42 Btu/h
Temperature: conversion formulae
0 °C = 32 °F 0 °F = -17.8 °C Weight
Poids (3)
°F = (9/5) x °C +32 °C = (5/9) x °F -17.8

Temperature: conversion table


°F °C °F °C °F °C °F °C
0 -17,8 30 -1,1 50 10,0 80 26,7
10 -12,2 32 0 60 15,6 90 32,2
20 -6,7 40 4,4 70 21,1 100 37,8
Diameter of particles (µm)

Energy
1 kcal/kg = 4.19.103 J/kg 1 J/kg = 0.239.10-3 kcal/kg Diagram of Whitby: This diagram shows that more than 99.90% of airborne
particles are less than or equal to 1 μm in size.
Heat transmission Therefore, the essential part of air filtration’s activity takes place in the invisible
1 kcal/h.m².°C = 1.16 W/(m².°C) 1 W/(m².°C) = 0.86 kcal/h.m².°C domain (human ocular partition power: 30 μm).
1 Btu/(h.ft².°F) = 5.64 W/(m².°C) 1 W/(m².°C) = 0.177 Btu/(h.ft².°F)
Diagram of particle sizes
FILTER ENGINEERING - Theory

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
MPPS
Minimum efficiency of air filters

0.01 0.1 0.2

The overall efficiency of an air filter is the result of a combination of 4 basic


filtration mechanisms (sieving, inertia, interception and diffusion), so that the
efficiency curve of an air filter adopts a characteristic V shape showing a minimum
level of efficiency. This minimum efficiency corresponds to a particle size called
MPPS (Most Penetrating Particle Size). In other words, the MPPS is the particle
size that is the most difficult to stop. The MPPS is situated between 0.1 and 0.2
μm depending on the filter type, and the speed of air flow through the filtering
media

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

94
A i r F i l t e r Te c h n o l o g y

Camfil Farr Solutions


Standard terms & conditions for the sale of goods
1. Interpretation contrary.
1.1 In these terms and conditions the following words have the following meanings: “Business Days” any 4.8.2 Irrespective of condition 4.5, the Company shall not be liable for any non-delivery of Goods (even if
day other than a Saturday or Sunday or a public or bank holiday In England; “Buyer” the person(s) or caused by the Company’s negligence) unless written notice is given to the Company within 7 days of the
company whose order for the Goods is accepted by the Company; “Company” Camfil Limited t/a Camfil date when the Goods would in the ordinary course of events have been delivered.
Farr with company registration number 01404355 and with registered office at Knowsley Road, 4.8.3 Any liability of the Company for the Goods for non-delivery shall be limited to replacing the Goods
Haslingden, Lancashire BB4 4EG; “Contract” any contract between the Company and the Buyer for the within a reasonable time or at the option of the Company issuing of a credit note against any invoice
sale and purchase of the Goods; “Delivery Point” the place where delivery of the Goods is to take place raised for such Goods.
under condition 4; “Goods” any goods which the Company is to supply to the Buyer (including any of them 4.8.4 A signature of qualified acceptance on a carrier’s delivery note shall not be written notice to either
or any part of them); “Intellectual Property” all intellectual and industrial property rights, including without the carrier or the Company for the purpose of these terms and conditions.
limitation, patents, rights in Know-How, trade marks, registered designs, models, unregistered design 5. Services
rights, unregistered trade marks and copyright (whether in drawings (including manufacturing drawings), 5.1 The Services shall be performed in the manner set out in the Specification.

Pre-Filtration, Class G3 to F5
plans, specifications, designs and computer software or otherwise), database rights, topography rights, 5.2 The Company shall agree with the Buyer the date and the place at which the Goods shall be ready for
any rights in any invention, discovery or process, and applications for and rights to apply for any of the testing and commissioning as provided for in the Contract.
foregoing, in each case in the United Kingdom and all other countries in the world; “Operational 5.3 Any dates specified by the Company for testing and commissioning as provided for in the Contract
Parameters” operational conditions under which the Goods will operate safely and effectively as referred are approximate only and may not be made of the essence by notice.
to in the quotation; “Practical Completion” the completion of the provision of the agreed Services by the 5.4 Company’s Obligations
Company; “Services” any design work, assembly, installation, testing, commissioning and maintenance 5.4.1 Subject to the provisions of the Contract, the Company shall with due skill and care design,
services which the parties have agreed the Company is to supply to the Buyer (including any of them or manufacture and deliver to site, erect, test and commission the Goods, carry out the Services and
any part of them); “Site” the site at which the Company is to perform the Services; “Specification” the complete any tests provided for in the Contract.
written specification of technical requirements by the Buyer in relation to the provision of the Goods and/ 5.5 Buyer’s Obligations
or Services by the Company. 5.5.1 The Buyer shall provide (or shall procure the provision of) at its own expense and in a timely
1.2 The headings in these terms and conditions are for convenience only and shall not affect their manner the Company and its employees, agents and sub-contractors with:
interpretation. 5.5.1.1 all necessary access to the Site in reasonable time for the proper performance of the Contract
and to include access to such roads or other means of access as may be necessary;
2. Formation and incorporation 5.5.1.2 all relevant consents, wayleaves, approvals, import licences and permits as are required for the
2.1 Subject to any variation under condition 2.4, each Contract will be on these terms and conditions to provision of the Services by the Company;
the exclusion of all other terms and conditions (including any terms or conditions which the Buyer 5.5.1.3 all building structures, foundations, approaches or work equipment or materials within the time
purports to apply under any purchase order, confirmation of order or similar document). specified in the Contract and of the quantity specified and in a condition suitable for the efficient
2.2 The order for Goods and Services by the Buyer from the Company shall be deemed to be an offer by transportation, reception, installation and maintenance of the Goods and/or Services;
the Buyer to purchase such Goods and Services subject to these terms and conditions. 5.5.1.4 any suitable lifting equipment belonging to the Buyer that may be available on Site to operate for
the purposes of the Services;

Bag and Compact Filters,


2.3 No terms or conditions endorsed upon, delivered with or contained in the Buyer’s Specification,
purchase order or similar document will form part of any Contract simply as a result of a reference to 5.5.1.5 where agreed in the Contract, make available sufficiently skilled persons necessary to perform
such document being referred to in a Contract. the Services (including, without limitation, masons, joiners, builders and electricians);
2.4 Any variation to these terms and conditions and any representations about the Goods and Services 5.5.1.6 such supplies of electricity, water, gas, air and other substances or facilities at the Site for use

Class F5 to F9
shall have no effect unless expressly agreed in writing and signed by either the Commercial Manager or a by the Company that may be specified in the Contract;
Director of the Company. The Buyer must ensure that the terms of its purchase order and any applicable 5.5.1.7 where the Contract provides for any tests or commissioning on Site, unless otherwise stated in
Specification are complete and accurate. the Contract, such fuel, electricity and other services or materials that may reasonably be requested by
2.5 Acceptance of delivery of the Goods or commencement of the performance of the Services shall be the Company to enable such tests or commissioning to be carried out effectively;
deemed to be conclusive evidence of the Buyer’s acceptance of these terms and conditions. 5.5.1.8 access to a canteen or restroom (where available);
2.6 Any quotation is given on the basis that no Contract will come into existence until the Company 5.5.1.9 appropriate waste disposal facilities (including, without limitation, a designated waste point on
despatches a written acknowledgement of order to the Buyer. Any quotation is valid for a period of 30 Site); and
days only from its date provided the Company has not previously withdrawn it. 5.5.1.10 all assistance as may be reasonably required by the Company as necessary for the proper
2.7 No order which the Company has accepted may be cancelled by the Buyer except with the written performance of the Contract.
agreement of the Company in response to a written request of the Buyer and on terms that the Buyer
shall indemnify the Company in full against all losses (including loss of profit), costs, damages, charges
and expenses suffered or incurred by the Company as a result of such cancellation. 5.6 Where the Services are to be performed or the Goods are to be supplied outside the UK, the Buyer
will assist the Company to ascertain the nature and extent of and to comply with laws, regulations, orders
or by-laws of any local or national authority having the force of law in the country where the Services are
3. Description
to be performed or the Goods supplied, or which may affect the Company in the performance of its

H E PA / U L PA F i l t e r s , C l a s s
3.1 The description of the Goods and Services shall be as set out in the Company’s quotation. Any obligations under the Contract.
Specifications, drawings etc. intended to form part of the Contract will be referred to in the quotation. 5.7 Unless otherwise agreed in writing by the Company, any dates specified by the Company for
3.2 Except where express agreement to the contrary in writing has been made with the Buyer, the Practical Completion are approximate only and may not be made of the essence by notice. If no dates
Company may make any changes to the specification, design, materials or finishes of the Goods: are so specified, Practical Completion will be within a reasonable time of the Company being provided
3.2.1 which are required to conform with any applicable safety or other statutory requirements; or

H10 to U17
with suitable access to the Site.
3.2.2 which it deems desirable and which do not materially affect their quality or performance. 5.8 Subject to the other provisions of these terms and conditions the Company will not be liable for any
3.3 No variation in the specification or design of any Goods which, in the Company’s reasonable opinion, loss (including loss of profit), costs, damages, charges or expenses caused directly or indirectly by any
does not adversely affect the suitability of the Goods for the particular purpose for which they are delay in or failure to achieve the Practical Completion by any date or within any time period set out in the
supplied by the Company will constitute a breach of contract or impose any liability upon the Company. Contract (even if caused by the Company’s negligence).
5.9 Where the Company incurs extra cost during the provision of the Services resulting from suspension
4. Delivery of the goods of work, the Buyer’s instructions or lack of instructions, the Buyer’s act or omission, the Buyer’s failure or
4.1 Delivery of the Goods shall be made on the basis and at such place as agreed between the parties delay to comply with the obligations of condition 5.5 and 5.6, interruptions, delays, overtime, unusual
and as set out by the Company in the written acknowledgement of order in accordance with condition hours, mistakes, or work for which the Company is not responsible, such extra cost as well as the cost
2.6. incurred by keeping any of the workforce on Site after completion of the Services on Site, shall be added
4.2 The Buyer will take delivery of the Goods within 10 days of the Company giving it notice that the to the Contract price and be for the account of the Buyer and in accordance with the provisions of the
Goods are ready for delivery. The Buyer must accept delivery of the Goods and pay for them in full. Contract.
4.3 Notwithstanding condition 4.1, any dates specified by the Company for delivery of the Goods are 5.10 Where Services have been provided by the Company the Goods shall be deemed to be accepted by
approximate only and may not be made of the essence by notice. the Buyer at the earlier of:

Carbon and Chemical Filters


As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

4.4 If the Buyer fails to take delivery of the Goods when they are ready for delivery pursuant to condition 5.10.1 the Company certifying in writing that erection is complete, or where the Company is required to
4.1 or to provide any instructions, documents, licences or authorisations required to enable the Goods to test the Goods on Site, the Company certifying that the Goods have passed such tests; or
be delivered on time (except because of the Company’s fault) risk in the Goods will pass to the Buyer 5.10.2 the Buyer taking over the Goods.
(including, without limitation, for loss or damage caused by the Company’s negligence); the Goods will be 6. Force majeure
deemed to have been delivered and (without prejudice to its other rights) the Company may: 6.1 The Company shall not be liable to the Buyer in any manner or be deemed to be in breach of a
4.4.1 store or arrange for the storage of the Goods until actual delivery or sale and charge the Buyer for Contract (subject to condition 10) because of any delay in performing or any failure to perform any of the
all related costs and expenses (including, without limitation, storage and insurance); and/or Company’s obligations under this Contract if the delay or failure was due to any cause beyond the
4.4.2 following written notice to the Buyer, sell any of the Goods at the best price reasonably obtainable Company’s reasonable control.
in the circumstances and charge the Buyer for any shortfall below the price under the Contract. 6.2 Without prejudice to the generality of condition 6.1 the following shall be included as causes beyond
4.5 If carriage is required in accordance with condition the Company’s reasonable control:
4.5.1 the Goods shall be transported by such means as the Company thinks fit unless the Buyer has 6.2.1 governmental actions, war or threat of war, national emergency, riot, civil disturbance, sabotage,
specified in its order the details of the contract with a carrier which it reasonably requires having regard terrorism or threat of terrorism or requisition;
to the nature of the Goods and the other circumstances of the case. 6.2.2 Act of God, fire, explosion, flood, epidemic or accident;
4.6 Off-loading by the Buyer 6.2.3 import or export regulations or embargoes;
4.6.1 Where it is agreed that the Buyer shall off-load the Goods the Buyer will provide at its expense at 6.2.4 labour disputes not including disputes involving the Company’s work-force;
the Delivery Point adequate and appropriate equipment and manual labour for off-loading the Goods. 6.2.5 inability to obtain or delay in obtaining supplies of adequate or suitable material, fuel, parts,
4.6.2 Where condition machinery or labour; or
4.6.1 applies, the Buyer will indemnify the Company against any liability and expense (whether arising 6.2.6 any failure or negligence or breach of contract on the part of the Buyer or its sub-contractors,
Filter Frames and Housings

under statute or common law) caused by the Buyer’s failure to provide appropriate equipment and contractors, agents or employees.
manual labour for off-loading (whether or not the off-loading is supervised by or on behalf of the Buyer)
for: 7. Risk/Ownership
4.6.2.1 any personal injury to or death of any of the Company’s employees, agents or sub-contractors or
any third party; and 7.1 Risk or damage to or loss of Goods shall pass to the Buyer upon delivery of the Goods, (unless
4.6.2.2 any damage to or loss of any property of the Company, its employees, agents or sub-contractors otherwise agreed in writing by the parties).
or any third party. 7.2 Ownership of the Goods shall not pass to the Buyer until the Company has received in full (in cash or
cleared funds) all sums due to it in respect of:
4.7 Instalments 7.2.1 the Goods and Services; and
4.7.1 The Company may make delivery of the Goods by instalments. 7.2.2 all other sums which are or which become due to the Company from the Buyer on any account.
4.7.2 Each separate instalment shall be invoiced and paid for in accordance with the Contract. 7.3 Until ownership of the Goods has passed to the Buyer, the Buyer must:
4.7.3 Failure by the Company to deliver any one or more (but not all) instalments in accordance with a 7.3.1 hold the Goods on a fiduciary basis as the Company’s bailee;
Contract or any claim by the Buyer in respect of any one or more (but not all) instalments shall not entitle 7.3.2 store the Goods (at no cost to the Company) separately from all other goods of the Buyer or any
the Buyer to treat that Contract as repudiated. third party in such a way that they remain readily identifiable as the Company’s property;
4.7.4 Failure by the Buyer to pay for any one or more instalments in accordance with a Contract shall 7.3.3 not destroy, deface or obscure any identifying mark or packaging on or relating to the Goods;
entitle the Company (without prejudice to its other rights and remedies): 7.3.4 maintain the Goods in satisfactory condition insured on the Company’s behalf for their full price
4.7.4.1 to suspend without further notice deliveries of Goods or goods under any other contract between against all risks to the reasonable satisfaction of the Company. On request the Buyer shall produce the
the Company and the Buyer pending payment by the Buyer; and/or policy of insurance to the Company; and
4.7.4.2 to treat that Contract as repudiated by the Buyer. 7.3.5 hold the proceeds of the insurance referred to in condition 7.3.4 on trust for the Company and not
4.8 Non-Delivery of the Goods mix them with any other money, nor pay the proceeds into an overdrawn bank account.
4.8.1 Irrespective of condition 4.5, the quantity of any consignment of Goods as recorded by the 7.4 The Buyer may resell the Goods before ownership has passed to it solely on the following conditions:
A i r F i l t e r Te c h n o l o g y

Company upon despatch from the Company’s place of business shall be conclusive evidence of the 7.4.1 any sale shall be effected in the ordinary course of the Buyer’s business at full market value and the
quantity received by the Buyer on delivery unless the Buyer can provide conclusive evidence proving the Buyer shall account to the Company accordingly; and

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

95
A i r F i l t e r Te c h n o l o g y

Standard terms & conditions for the sale of goods


7.4.2 any such sale shall be a sale of the Company’s property on the Buyer’s own behalf and the Buyer
shall deal as principal when making such a sale. Company’s total liability arising in connection with the performance or contemplated performance of the
7.5 Where the Company is unable to determine whether any goods are the Goods, the Buyer shall be Contract by reason of any breach of contract or of statutory duty or tort (including but not limited to
deemed to have sold all goods of the kind sold by the Company to the Buyer in the order in which they negligence), or any failure to perform or delay in performing of any obligations by the Company under the
were invoiced to the Buyer. Contract shall be limited to the £[Contract Price]; and
7.6 The Company shall be entitled to recover payment for the Goods notwithstanding that ownership of 10.2.5.2 the Company shall not be liable by way of indemnity or by reason of any breach of contract or
any of the Goods has not passed from the Company. of statutory duty, by reason of tort (including but not limited to negligence) for any loss of profit, loss of
7.7 The Buyer grants the Company, its agents and employees an irrevocable licence at any time to enter use, loss of production, loss of contracts, loss of goodwill or for any financial or economic loss or for any
any premises where the Goods are or may be stored in order to inspect them, or, where the Buyer’s right indirect or consequential damage whatsoever that may be suffered by the Buyer.
to possession has terminated, to recover them.
11. Termination
8. Price 11.1 Each Contract will terminate immediately upon the happening of any one or more of the following
8.1 The price for the Goods and Services shall be the Company’s quoted price referred to in the events; the Buyer has a bankruptcy order made against him or makes an arrangement or composition
Company’s quotation which shall be binding upon the Company only if the Buyer accepts the Company’s with his creditors or otherwise takes the benefit of any Act for the time being in force for the relief of
quotation within 30 days (provided the quotation has not already been withdrawn by the Company) after insolvent debtors, or (being a body corporate) convenes a meeting of creditors (whether formal or
which time it may be altered by the Company without notice. informal) or enters into liquidation (whether voluntary or compulsory) except a solvent voluntary liquidation
8.2 Unless otherwise agreed in writing between the parties, the price for the Goods and Services is for the purpose only of reconstruction or amalgamation, or has a receiver, manager, administrator or
exclusive of any: administrative receiver appointed of its undertaking or any part thereof, or a resolution is passed or a
8.2.1 value added tax or other applicable tax; petition presented to any court for the winding-up of the Buyer or for the granting of an administration
8.2.2 transport, packaging, loading, unloading and insurance; order in respect of the Buyer or any proceedings are commenced relating to the insolvency or possible
8.2.3 in the case of export, import duties, dues, taxes and other charges; and insolvency of the Buyer.
8.2.4 cost of obtaining any applicable licences and permits necessary to perform the Contract, which the 11.2 Each Contract will terminate immediately upon service of written notice of termination by the
Buyer shall pay in addition when it is due to pay for the Goods and Services in accordance with the Company on the Buyer on the happening of any one or more of the following; the Buyer suffers or allows
Contract. any execution whether legal or equitable to be levied on his/its property or obtained against him/it, or
8.3 The Company may, by giving notice to the Buyer at any time increase the price of the Goods and fails to observe or perform any of his/its obligations or duties under the Contract or any other contract
Services to reflect any increase in the cost of manufacture or delivery of the Goods or performance of between the Company and the Buyer or is unable to pay its debts within the meaning of section 123 of
the Services which is due to: the Insolvency Act 1986 or the Buyer ceases to trade.
8.3.1 any factor beyond the reasonable control of the Company; this includes without limitation, foreign 11.3 The Company’s rights contained in condition 6, 7,9 and 10 (but not the Buyer’s rights) shall continue
exchange fluctuation, currency regulation, alteration of duties and taxes; beyond the discharge of the Buyer’s and the Company’s primary obligations under the Contract
8.3.2 any change in delivery dates, quantities or specifications for the Goods and Services requested by consequent upon its termination.
the Buyer; 11.4 The termination of the Contract howsoever arising shall be without prejudice to the rights and duties
8.3.3 any delay caused by any instructions of the Buyer or failure of the Buyer to give the Company of either the Buyer or the Company accrued prior to termination.
adequate information or instructions. Any dispute as to the amount of any increase in price shall be
determined by the Company’s auditors whose decision shall be conclusive and binding on the Company 12. Communication
and the Buyer. 12.1 All communications between the parties about any Contract must be in writing and delivered by
hand or sent by pre-paid first class post or sent by facsimile transmission or electronic mail:-
9. Payment 12.1.1 (in case of communications to the Company) to its registered office or such changed address as
9.1 The Company may invoice the Buyer for the Goods and Services in accordance with the terms set shall be notified to the Buyer by the Company; or
out in the Company’s quotation. 12.1.2 (in the case of the communications to the Buyer) to the registered office of the addressee (if it is
9.2 Time for payment shall be of the essence. a company) or (in any other case) to any address of the Buyer set out in any document which forms part
9.3 Payment of the price for the Goods and Services is due in sterling or such other agreed currency of the Contract or such other address as shall be notified to the Company by the Buyer.
within 10 (ten) Business Days of the date of receipt of the invoice. 12.2 Communications shall be deemed to have been received:
9.4 No payment shall be deemed to have been received until the Company has received cleared funds. 12.2.1 if sent by pre-paid first class post, 2 Business Days after posting (exclusive of the day of posting);
9.5 All payments payable to the Company under this Contract shall become due immediately upon 12.2.2 if delivered by hand, on the day of delivery;
termination of this Contract despite any other provision. 12.2.3 if sent by facsimile transmission or electronic mail on a working day prior to 4:00pm, at the time
9.6 The Buyer shall make all payments due under this Contract without any deduction whether by way of of transmission and otherwise on the next working day.
set-off, counterclaim or otherwise unless the Buyer has a valid court order requiring an amount equal to 12.3 Communications addressed to the Company shall be marked for the attention of the Commercial
such deduction to be paid by the Company to the Buyer. Manager or a Director of the Company.
9.7 If the Buyer fails to make any payment under this Contract on the due date then (without prejudice to
its other rights and remedies): 13. Intellectual property rights
9.7.1 the Company may charge the Buyer interest (both before and after judgement) on the amount 13.1 Where the Goods or any part of them are manufactured or any process is to be applied to the
unpaid at the annual rate of 4% above the base rate of SEB, Cannon Street, London, from time to time Goods by or on behalf of the Company to the Specification then the Buyer shall indemnify the Company
until payment is made in full (a part of a month being treated as a full month for the purpose of calculating against all liability, actions, proceedings, costs, claims, damages or demands in any way connected with
interest); and the Contract brought or threatened to be brought against the Company by any third party as a result of
9.7.2 the Company shall be entitled to suspend performance of any of its obligations under the Contract the infringement or alleged infringement of any third party’s Intellectual Property Rights. If any such claim
until the outstanding amount has been received by the Company from the Buyer. is brought or threatened against the Company then the Company shall be entitled to suspend deliveries of
the Goods and/or performance of the Services.
10. Quality 13.2 All information of any kind (including without limitation drawings, specifications, plans, descriptions,
10.1 Warranty blue prints, designs, documents and technical information) supplied by the Company to the Buyer is
10.1.1 The Company warrants that (subject to the other provisions of these terms and conditions) upon supplied on the strict understanding that the Intellectual Property Rights therein and in the Goods and the
delivery the Goods will, and for a period of 12 (twelve) months from the date of delivery, be of Services are vested in and shall remain the sole property of the Company. If the Buyer shall in any way
satisfactory quality within the meaning of the Sale of Goods Act 1994. acquire such rights then the Buyer shall immediately inform the Company and shall take such steps
10.1.2 The Company will, free of charge, within a period of 12 (twelve) months from the date of delivery immediately as may be required by the Company to assign such rights or vest title in such rights in the
(or deemed delivery under condition 4.4) repair or, at the option of the Company replace Goods (or the Company.
relevant part of the Goods) which are proved to the reasonable satisfaction of the Company to have been
at the time of delivery (a) damaged or defective; or (b) not complying with the Specification due to 14. General
defects in material, or workmanship or design (other than a design made, furnished or specified by the 14.1 Time for performance of all obligations of the Buyer is of the essence.

As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.
Buyer). This obligation will not apply where: 14.2 Each right or remedy of the Company under the Contract is without prejudice to any other right or
10.1.2.1 the Buyer has failed to notify the Company of any defect or suspected defect within 14 days of remedy of the Company whether under the Contract or not.
the delivery where the defect should be apparent on reasonable inspection, or within 14 days of the same 14.3 Any provision of the Contract which is held by any competent authority to be invalid, void, voidable,
coming to the knowledge of the Buyer (where the defect is not one which should be apparent on unenforceable or unreasonable (in whole or in part) shall to the extent of such invalidity, voidness,
reasonable inspection) and in any event no later than 12 (twelve) months from the date of delivery; or voidability, unenforceability or unreasonableness be deemed severable and the other provisions of the
10.1.2.2 the Buyer has failed to give the Company a reasonable opportunity of examining such Goods Contract and the remainder of such provision shall not be affected.
after receiving the notice of any defect or suspected defect; or 14.4 Failure by the Company to enforce or partially enforce any provision of the Contract will not be
10.1.2.3 the defect arises because the Buyer (or the Buyer’s customer) failed to follow the Company’s construed as a waiver of any of its rights under the Contract.
oral or written instructions as to the storage, installation, testing and commissioning (if applicable), use, 14.5 The Company may assign, license or sub-contract all or any part of its rights or obligations under
Operational Parameters or maintenance of the Goods or (if there are none) good trade practice; or the Contract without the Buyer’s consent.
10.1.2.4 the Buyer (or the Buyer’s customer) alters or repairs such Goods or without the written consent 14.6 The Contract is personal to the Buyer who may not assign, license or sub-contract all or any of its
of the Company; or rights or obligations under the Contract without the Company’s prior written consent.
10.1.2.5 the defect in such Goods arises from any defect in any drawing, design, Specification or 14.7 The Company and the Buyer do not intend that any of the terms of the Contract will be enforceable
instruction supplied or approved by the Buyer. Any Goods replaced will belong to the Company and any by virtue of the Contracts (Rights of Third Parties) Act 1999 by any person not a party to it.
repaired Goods or replacement Goods will be guaranteed on these terms and conditions for the 14.8 The formation, construction, performance, validity and all aspects of the Contract are governed by
unexpired portion of the 12 (twelve) month period from the original date of delivery of the replaced English law and the parties submit to the non-exclusive jurisdiction of the English Courts.
Goods.
10.1.3 Any Goods repaired or replaced by the Company pursuant to this condition 10 will be supplied to
these terms and conditions.
10.1.4 If the Company complies with condition 10.1.2 it shall have no further liability for a breach of
warranty in condition
10.1.5 in respect of the quality of such Goods.
10.2 Indemnity and Limitation of liability
10.2.1 The Buyer shall indemnify the Company against all liability, actions, proceedings, costs, claims,
damages or demands in any way connected with this Contract brought or threatened to be brought
against the Company by any third party except to the extent the Company is liable to the Buyer in
accordance with these terms and conditions.
10.2.2 Subject to condition 10.1.1 and to the maximum extent permissible in law, all conditions and
warranties which are implied by statute or otherwise by general law into any Contract or relating to the
Goods or the Services are hereby excluded.
10.2.3 The Company does not, unless otherwise expressly provided in the Contract, warrant that the
Services or the Goods as described or provided or the incorporation thereof within some larger project
will satisfy the Buyer’s requirements.
10.2.4 The Company will accept unlimited liability for:
10.2.4.1 death or personal injury caused by the negligence of the Company; and
10.2.4.2 any breach of its obligations implied by Section 12 of the Sale of Goods Act 1979 or Section 2
of the Supply of Goods and Services Act 1982; and
10.2.4.3 fraudulent misrepresentation.
THE BUYERS ATTENTION IS IN PARTICULAR DRAWN TO THE PROVISION OF CONDITION 10.2.5
10.2.5 Subject to conditions 10.2.2, 10.2.3 and 10.2.4:
10.2.5.1 except in the case of any liability on the part of the Company referred to in condition 10.2.4, the

Knowsley Road, Haslingden, Lancashire, BB4 4EG


Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk

96
As part of our continuous improvement, Camfil Farr reserve the right to change specifications without notice.

Notes
A i r F i l t e r Te c h n o l o g y

www.camfilfarr.co.uk
Knowsley Road, Haslingden, Lancashire, BB4 4EG
Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736

97
A i r F i l t e r Te c h n o l o g y Filter Frames and Housings Carbon and Chemical Filters H E PA / U L PA F i l t e r s , C l a s s Bag and Compact Filters, Pre-Filtration, Class G3 to F5 Camfil Farr Solutions
H10 to U17 Class F5 to F9
Cover 3_080616.pdf 2008-06-16 13:25:34

Head Office : Regional Centres :

MANCHESTER LONDON
Head Office & Manufacturing Plant
Camfil Limited MIDLANDS
Knowsley Road
Haslingden SCOTLAND
Lancashire
BB4 4EG
Tel: +44 (0) 1706 238000
Fax: +44 (0) 1706 226736

Industry Segment Specialists :

AIR HYGIENE
Viv Turner

AUTOMOTIVE
C Mark Taylor
M

COMFORT SEGMENT
Y

Glasgow David Moulton


CM

CONSULTANTS & SPECIFIERS


MY

CY

Peter Dyment
CMY

CONTAINMENT SYSTEMS
K

Mike Vinson

DUST CONTROL
Manchester
John Purvis/Matthew Brown

FOOD INDUSTRY
Birmingham
Tim Pagett

GAS TURBINE
Martin Stenton
London
HOSPITALS
Dave Rimmer

MOLECULAR FILTRATION
Chris Ecob

PHARMACEUTICAL
Neil Orrill

VEHICLE REFINISHING
www.camfilfarr.co.uk Gary Warrington
On world standards...

...Camfil Farr is the leader in clean air


technology and air filter production.
Camfil Farr has its own product
development, R&D and world wide local
representation.
Our overall quality goal is to develop,
produce and market products and services
of such a quality that we aim to exceed our
customers expectations.
We see our activities and products as an
expression of our quality.
To reach a level of total quality it is
necessary to establish an internal work
environment where all Camfil Farr
employees can succeed together. This
means an environment characterised by
openness, confidence and good business
understanding.

www.camfilfarr.co.uk

Camfil Limited
Knowsley Road
Haslingden
Lancashire
BB4 4EG
Tel: +44 (0) 1 706 238000
Fax: +44 (0) 1 706 226736
E-mail: sales@camfil.co.uk

Cover 1_4 UK 080612.indd 1 2008-06-16 13:38:02

Você também pode gostar