ATRONIC OXYGEN™ Cabinet

Installation Manual

Rev. 1.1
April 2010
Release Info
ATRONIC OXYGEN™ Cabinet
Installation Manual

Rev. 1.1

Rel.: April 2010

Copyright Notice:
© 2010, ATRONIC. All rights reserved.
No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval
system, or translated into any human or computer language, in any form or by any means, electronic,
mechanical, magnetic, manual, or otherwise, or disclosed to third parties without the express written
permission obtained from a properly authorized official of ATRONIC.

DISCLAIMER
ATRONIC makes no representation or warranties, express or implied, with respect to this publication,
or any product of ATRONIC, including but not limited to warranties of merchantability or fitness for any
particular purpose. ATRONIC reserves the right to make changes, enhancements, revisions and altera-
tions of any kind to this publication or the product(s) it covers without obligation to notify any person,
institution or organization of such changes, enhancements, revisions and alterations.

TRADEMARKS
This document may contain trademarks of ATRONIC. All other brand and product names are trademarks
or registered trademarks of their respective companies.

OXYGEN™ - Installation Manual 2


Table of Contents
1. About this Manual...................................................................................................... 4
1.1 Scope................................................................................................................... 4
1.2 Target Audience............................................................................................... 4
1.3 Included Software Releases........................................................................ 4
1.4 Related Publications...................................................................................... 5

2. Safety Instructions..................................................................................................... 7
2.1 Safety Instructions - Electrical.................................................................... 7
2.2 Safety Instructions - Mechanical............................................................... 8
2.3 Safety Instructions - Other........................................................................... 8
2.4 Environmental.................................................................................................. 8

3. Technical Data.............................................................................................................. 9
3.1 Specifications................................................................................................... 9
3.2 Dimensions.....................................................................................................10
3.3 Minimum Clearance.....................................................................................10
3.4 Footprint / Drill Pattern...............................................................................11
3.5 Ergonomics.....................................................................................................12

4. Machine Components............................................................................................13
4.1 Cabinet Closed...............................................................................................13
4.2 Main Door Opened.......................................................................................14
4.3 Belly Door Opened.......................................................................................15
4.4 Logic Box..........................................................................................................16

5. Machine Installation...............................................................................................18
5.1 Inspect the Machines..................................................................................19
5.2 Machine Mounting.......................................................................................20
5.3 Install Top Light or Topper.........................................................................21
5.4 Replace Shipping Locks..............................................................................22
5.5 Prepare Coin Acceptor (MC-62)...............................................................22
5.6 Check Cables and Connectors..................................................................22
5.7 Check Game Cards........................................................................................22
5.8 Install Operator Specific Components..................................................23
5.9 Connect to Floor Network.........................................................................24
5.9.1 CRYSTAL.net™.................................................................................24
5.9.2 CRYSTAL WEB™...............................................................................24
5.9.3 Non ATRONIC SMIBs.....................................................................24
5.9.4 System Connectors Pinout........................................................25

6. Bringing into Service..............................................................................................26


6.1 Initial Power-up.............................................................................................26
6.2 Basic Setup......................................................................................................27

7. Technical Support.....................................................................................................28

OXYGEN™ - Installation Manual 3


1. About this Manual

1.  About this Manual


1.1  Scope
The OXYGEN™ Installation Manual describes how to install
an ATRONIC OXYGEN™ gaming machine featuring ATRONIC’s
sensys EP™ electronic platform.

It describes how to mount the machine to a base and relevant


procedures to be carried out before the machine can be put
into operation. Further it contains important safety instruc-
tions, technical data and cabinet drawings.

Note: This document contains only procedural guideline for the


OXYGEN™ cabinet. Each regulatory jurisdiction and gaming site
have their own internal controls, policies and procedures that
must be followed when accessing machines and setting configu-
ration options. You are responsible for understanding and abid-
ing by the rules that apply in your environment.

1.2  Target Audience


Technical Personnel
We address qualified technical personnel, who are involved in
installation, setup and configuration of ATRONIC gaming ma-
chines. With this user group we assume that they are basically
familiar with gaming machines and casino related terminol-
ogy.
Please read this document and the contained safety instruc-
tions carefully before you start machine installation.

Floor Personnel
Further we address floor personnel that is allowed to open the
machine‘s main door for maintenance purposes.
Please read the contained safety instructions before you open
the main door.

1.3  Included Software Releases


The installation procedures described in this manual do not
relate to a certain software version.

OXYGEN™ - Installation Manual 4


1. About this Manual

1.4  Related Publications


More detailed information about the OXYGEN™ cabinet, the
­sensys EP™ electronic platform and the diversity™ multi-game
software can be found in the following publications:

• Software Manual
Manual diversity™ Software (D.3.x.x STD)

• Operating Manual
Manual OXYGEN™ - Operating (D.3.x.x STD)

• Peripherals (coin- and bill acceptors, hopper, etc.)


-> See folder “Peripherals” on the Service Manual CD.

• Spare Parts
Manual OXYGEN™ - Parts Catalogue

Note: All mentioned manuals can be found on a CD-ROM titled


“ATRONIC Service CD Manual 2010“ or www.atronic.com*

If this manual did not came on this CD-ROM, please ask ATRONIC
Technical Service for a free copy of the latest revision.
* to gain access an active Gamebook account is necessary.

Service Manual CD 2010


ENG v1.0

OXYGEN™ - Installation Manual 5


- blank page -

OXYGEN™ - Installation Manual 6


2. Safety Instructions

2.  Safety Instructions

Observe this safety instructions, to avoid per-


sonal injury or a possible damage to hard-
ware, software, or data.

As this machine has to be opened for maintenance, refill and


emptying, operators have to make sure the involved person-
nel takes note of this safety instructions.

2.1  Safety Instructions - Electrical


Warning! Risk of Electric Shock
Always switch off the machine and unplug the power cable
before servicing high voltage components.

Be sure to ground this machine to prevent a current leak.


ATRONIC makes no warranty as to the accidents (including
failures) caused by improper grounding.

Do not expose the power cable to mechanical load such as


contusion or tension. Damaged power cables can lead to fire
or shortcuts.

Use the specified fuses only. If the specified fuses easily blow
out, please consult ATRONIC Technical Services.

Always switch off the machine before removing or servicing


electronic components and before connecting/disconnecting
a connector.

Check that all connectors are seated correctly. False connec-


tions can cause irreparable damage, not covered by warranty.

Always take precautions against electrostatic discharges (ESD)


when handling circuit boards. Wear a grounded wrist strap
and avoid placing circuit boards on static generating surfaces
as carpet or upholstered chairs.

continued on next page...

OXYGEN™ - Installation Manual 7


2. Safety Instructions

2.2  Safety Instructions - Mechanical


Warning! Tip Hazard!
To avoid personal injury, the OXYGEN cabinet must be securely
attached to the base, and the base must be securely attached
to the floor or wall. See also section 5.2 Installation / Machine
Mounting.

Do not install the machine on unstable floor.

The machine is heavy. Always use appropriate equipment for


transportation and installation.

Caution! Moving Parts


Make sure to disable the hopper, when working on it.

2.3  Safety Instructions - Other


Only qualified personnel can assemble, install, maintain, in-
spect, and troubleshoot the machine.

Use only original ATRONIC parts for replacement.

Do not use chemical duster, thinner, benzine, alcohol, or syn-


thetic detergent for cleaning the machine. They can damage
the surface of the machine.

Please refer to relevant ATRONIC service manuals for further


instructions on setup, operation and maintenance.

2.4  Environmental
Adhere to the environmental specifications stated in section
3. Technical Data (next page).

Do not install this machine outdoors, or in areas with large


variation in temperature or excessive dust pollution.

The machine may only be installed or operated in dry condi-


tions.

The machine must not be cleaned using a high pressure clean-


er or a vapor jet and must not be installed or operated in areas
where high pressure cleaners or vapor jets are used.

If the machine was exposed to low temperatures, do not pow-


er on the machine until it has acclimatized to ambient tem-
perature and no condensing is present.

OXYGEN™ - Installation Manual 8


3. Technical Data

3.  Technical Data


3.1  Specifications
Manufacturer: ATRONIC Austria GmbH
Seering 13 - 14
A-8141 Unterpremstaetten

Model: SEPOXG / OXYGEN

Dimensions in mm: 613 / 1520 / 590 (w/o topper)


(max. w/h/d)

Weight: 97 kg (coin-less)
104 kg (coin-on)

Electrical Specification
Required Voltage: 100V to 240V AC
50Hz / 60Hz
Use earthed power outlet rated min. 8A / 115V, 4A / 230V.

Power Consumption
Idle Mode: 1,9A / 115V, 0,8A / 230V

Payout Mode: 2,4A / 115V, 1,2A / 230V

Max. Power: 450 Watt
(without internal power outlets)

Power Supply
Secondary Voltage: +24V / 5A; +12V / 17A;
- 12V / 0,5A; +5V / 20A;
+3.3V / 7A

Fuses (all glas fuses 5 x 20mm)


Main Fuse: T5A / 250V
Peripheral Board: F100 (+5 V0) = T 5A F100 F107

(secondary voltages) F102 (+12 VP_1) = T 5A


F103 (+12 VP_2) = T 5A F102 F104 F105 F103

F104 (+12 VP_3) = T 5A


F105 (+12 VP_4) = T 5A Secondary voltage fuses on the Peripheral
F107 (+24 V) = T 4A Board

Environmental Specifications
Operating Temperature: 0°C - 45°C (32°F - 113°F)
Operating Humidity: 0% to 85% (non condensing)

OXYGEN™ - Installation Manual 9


3. Technical Data

3.2  Dimensions
1520 (mm)
1390

510 348
560 492
613 590

3.3  Minimum Clearance


• Each OXYGEN™ machine should have a minimum base width of 720 mm, to fully open the main
door without touching the adjacent machine. This translates to a minimum space clearance of 210
mm between two OXYGEN™ machines (body side to body side).
• Leave a minimum space clearance of 245 mm to a wall (body side to wall).
720 720
245 210

OXYGEN™ - Installation Manual 10


3. Technical Data

3.4 Footprint / Drill Pattern

(105)* 330 (105)*


* This dimension * This dimension
depends on the
base width
223 depends on the
base width

67 REAR OF CABINET

37
67,5

57

Ø 12 mm (4x)

228,5
271,5 (mm)

CABLE DROP
Ø 64mm

296,5

336,5
COIN DROP
Ø 80mm
DRILL PATTERN
OXYGEN™ CABINET

67
297

ATRONIC 302,5
STANDARD
BASE (720mm) 510

(720)*

OXYGEN™ - Installation Manual 11


3.5  Ergonomics
The OXYGEN™ cabinet is designed to provide a maximum of playing comfort. For an optimal seating
and playing comfort, the difference between the base height and the seating height should be approxi-
mately 150 mm.

Based on a 1,75 m tall player this results in


• the natural line of sight is directed towards the center of the main monitor
• the arms are positioned in parallel to the floor and supported by the arm rests
• the legs are in a comfortable 90° angle
150 mm

Examples:
Height of available base is 24” / 60 cm --> use chair height 75 cm
Height of available base is 18” / 45 cm --> use chair height 60 cm
Height of available chair is 65 cm --> use 18” / 45 cm bases

OXYGEN™ - Installation Manual 12


4. Machine Components

4.  Machine Components


4.1  Cabinet Closed
Top Light

Topper

Top Box

Upper Loudspeakers Air Outlet

JACKPOT Key Switch


Upper Monitor AUDIT Key Switch
Main Monitor
Mechanical Meters

Player Tracking Area


(here with Card Reader)
Main Door Lock(s)
Loudspeaker
Ticket Outlet Main Door Release
Coin In
CASH OUT Button
BET - Button CALL ATTENDANT Button
BET + Button Name Plate
START / TAKE WIN Button Bill In
AUTOPLAY Button
MENU Button Belly Door Release /
GAMBLE Button Belly Door Lock
START / TAKE WIN Button

Coin Bowl

OXYGEN™ - Installation Manual 13


4. Machine Components

4.2  Main Door Opened

Top Box

Top Box Release

Logic Box
Logic Box Lock
Card Slot Cover

Peripheral Board

Main Door Switch


Mounting Bracket for
additional Equipment
Main Door Lock(s)
Ticket Printer Main Door Release

Bill Acceptor

Bill Door Lock


Power Outlets
Bill Door
Power Switch
Power Supply

Hopper Board Sub Woofer


Hopper

Cable Drop Hole


Coin Drop Hole

OXYGEN™ - Installation Manual 14


4. Machine Components

4.3  Belly Door Opened

Coin In - LED Board

Belly Door Switch


Bill In - LED Board

Coin Acceptor Belly Door Lock /


Coin Channels Belly Door Release
Diverter Solenoid Bill Door Lock
Bill Door
Pneumatic Spring

Coin In Bill In
/ Ticket Outlet

OXYGEN™ - Installation Manual 15


4. Machine Components

4.4  Logic Box

Figure shows logic box with the card slot cover removed

Fan (Air Outlet)

Peripheral Board
Connectors

HDMI Video Out (Upper)


HDMI Video Out (Main)

Game Smart Card


Logic Box Cover
Release
Game Compact Flash Card

Logic Box Switch


Audio Line In
USB Ports

LAN Port 1
LAN Port 2 (not used)

VGA (not used)


COM2
COM1 (GAT Port)

HDMI Audio Out

Power Supply
Connector

OXYGEN™ - Installation Manual 16


- blank page -

OXYGEN™ - Installation Manual 17


5. Machine Installation

5.  Machine Installation


This section should only be carried out by qualified service
personnel.

Review the list below and perform as needed. Explanations are Note: Depending on machine con-
located on the following pages and in additional manuals. figuration or jurisdictional require-
ments, additional tasks may have to
Inspect machines for transport damage. Any transport be carried out before the machine can
damage should be noted and witnessed by the freight be put into operation (e.g. acceptance
forwarder. The manufacturer accepts no responsibility for inspection, logic box sealing, etc.).
transport damage.

Check machines for the correct hardware configuration.



Prepare the stand by drilling the mounting holes, cable
drop and coin drop (if necessary).

Mount the machine to the base.

Install top light or topper

Replace shipping locks with casino specific locks.

Prepare the coin acceptor and the hopper.

Check that cables and connectors are seated correctly.

Check that the game cards are seated correctly.

Install operator specific components

Connect to the floor network (if applicable)

Apply power to the machine.

Load paper into the printer (if available).

Execute basic machine setup, if necessary (RAM Clear, Ini-


tial Setup and Jackpot Configuration).

Configure game (Service Menu / Settings).

Test bill and coin handling (Service Menu / Diagnostics).

OXYGEN™ - Installation Manual 18


5. Machine Installation

5.1  Inspect the Machines


(a) Unpack the machines and inspect them for transport dam-
age.

Any transport damage should be noted and witnessed by the


freight forwarder. The manufacturer accepts no responsibility
for transport damage.

(b) Check the machines for the correct hardware configuration


(bill acceptor, coin acceptor, hopper, and printer type)

OXYGEN™ - Installation Manual 19


5. Machine Installation

5.2 Machine Mounting

Warning! Tip Hazard!


To avoid personal injury, the OXYGEN™ cabinet
must be securely attached to the base using all
four mounting bolts, and the base must be se-
(105)* 330 (105)*
* This dimension * This dimension
depends on the
base width
223 depends on the
base width

67 REAR OF CABINET

curely attached to the floor or wall.

37
67,5

57
Ø 12 mm (4x)

228,5
271,5 (mm)
CABLE DROP

1. Obtain a suitable stand upon which to install the ­OXYGEN™. Ø 64mm

296,5

336,5
The drill pattern and the recommended minimum clear-
ance to the adjacent machines are provided in section 3.4 COIN DROP
Ø 80mm
DRILL PATTERN

Technical Data / Footprint/Drill Pattern.


OXYGEN™ CABINET

67
297

ATRONIC 302,5
STANDARD

2. Drill four mounting holes and a cable hole in the top of


BASE (720mm) 510

the base. If the machine will be using a coin drop bucket


inside the stand, then a coin drop hole must also be cut. (720)*

3. Place the machine on the base.

Caution! The machine is heavy.


Use a lift truck to transport and lift the machine.
Never use the arm rest to lift the machine!

If no lift truck is available, use the recessed grip at the low-


er side of the coin bowl to lift the machine. Do not use the
arm rest to lift or carry the machine.
Recessed Grips
4. Place the machine so that the holes on the bottom of the
machine are aligned with the holes on the base. You have
to remove the hopper (if installed) and the coin drop plas-
tic frame to get access to the mounting holes.

Warning! Hand or Head Injury!


The main door can slam closed, when the ma-
chine is moved jerkily.

5. Insert all four mounting bolts through the bottom of the


machine. Place a washer and nut on each of the four bolts
inside the base and tighten them. Ensure that no wires are
trapped when the bolts are tightened. Ensure that the ma-
chine is securely attached to the base, and that the base is
securely attached to the floor or wall.

6. Install the hopper and the coin drop frame, if previously


removed.

OXYGEN™ - Installation Manual 20


5.3  Install Top Light or Topper

To install the top light or the topper

1. Open the main door and press the top box release up-
wards to open the top box door.

Top Box Release

2. Unfasten, unplug and remove the upper monitor.

Note: When removing the monitor, make sure to lay it down


with the front side facing upwards, to avoid scratches in the
monitor surface.

3. (a) Mount the top light and connect the top light signal
and the top light earthing cable.

(b) Mount the topper and connect the topper signal and
the topper earthing cable.

4. Re-install the upper monitor, fasten it with four srews and


close the top box.

OXYGEN™ - Installation Manual 21


5. Machine Installation

5.4  Replace Shipping Locks


(1)
If not ordered otherwise, ATRONIC machines are equipped (2)
with shipping locks for easy start-up. These locks have to be (3)
replaced by casino specific locks to provide appropriate secu-
rity.
(1) Jackpot Key Switch (4)
(2) Audit Key Switch (5)
(3) Logic Box Lock
(4) Main Door Lock (6)
(5) Belly Door Lock
(6) Bill Door Lock / Stacker Locks

5.5  Prepare Coin Acceptor (MC-62)


• Slide holder for reference coin rightwards, remove (plas-
tic) transport chip and replace it with appropriate refer-
ence coin.

• Check the reference coin for proper (parallel) seating.

-> See manuals Peripherals / Coin Acceptor for details.

5.6 Check Cables and Connectors


Check that all connectors are seated correctly, prior to initial
power up.

Important: False or loose connections can cause


irreparable damage, not covered by warranty.

5.7  Check Game Cards (1)

Make sure that the Platform Smart Card (1), the Game Smart
Card (2) and the Game CF Card (3) are seated correctly, prior to
initial power up. The cards may loose connection during trans-
portation.
(3)

(2)

OXYGEN™ - Installation Manual 22


5. Machine Installation

5.8  Install Operator Specific Components


Install the operator specific components such as SMIB (Slot
Machine Interface Board), fiber optics board, etc., and player
tracking components (if applicable).

The OXYGEN™ cabinet provides a mounting bracket to install


additional components (fig. A).

(fig. A): Mounting area for additional compo-


nents

Player tracking components are installed on customized player


tracking brackets (fig. B). These brackets are usually supplied
by your player tracking components manufacturer.

Please refer to the relevant mounting instructions that came


with the bracket and the player tracking components.

(fig. B): Player tracking bracket

OXYGEN™ - Installation Manual 23


5. Machine Installation

5.9  Connect to Floor Network


5.9.1  CRYSTAL.net™

A OXYGEN™ machine configured for CRYSTAL.net™ commu-


nications will have a CRYSTAL Module (CMOD) installed. Con-
nect the CMODs Ethernet port 1 to the CRYSTAL Base Socket
(CBSO) which is usually installed in the machine base.

See ATRONIC SYSTEMS / CRYSTAL.net™ Technical Manual for


details.

5.9.2  CRYSTAL WEB™

A OXYGEN™ machine configured for CRYSTAL WEB™ com-


munications will have a Machine Data Controller (MDC) and
a Earth Print (EP) installed. Connect the Earth Print to the Base
Socket (BSO) which is usually installed in the machine base.

See ATRONIC SYSTEMS / CRYSTAL WEB™ Technical Manual for


details.

5.9.3  Non ATRONIC SMIBs

Operator specific Slot Machine Interface Boards (SMIB) have


to be connected to the Peripheral Board. The Peripheral Board SAS2
provides three RS232 serial ports to communicate with the SAS3
SMIB. The three serial ports correspond to SAS channels 1, 2
and 3.
Accounting
The connector for SAS channel 1 (accounting channel) also (SAS1)
incorporates the door contacts and is therefore split into two
connectors. The connectors for SAS channels 2 and 3 provide
serial communication only.

See next page for a connectors pinout.

OXYGEN™ - Installation Manual 24


5. Machine Installation

5.9.4  System Connectors Pinout

The accounting system connection (SAS channel 1) is split into two connectors P220 and P221.

Accounting System 1 14 Accounting System 1 12


(Peripheral Board P220) (Peripheral Board P221)

1 +5V 1 Belly Door - Normally Close


2 +12V 2 Belly Door - Common
3 COM 0 / RS232 RxD 3 Belly Door - Normally Open
4 COM 0 / RS232 TxD 4 Drop Door - Normally Close
5 Main Door - Normally Close 5 Drop Door - Common
6 Main Door - Common 6 Drop Door - Normally Open
7 Main Door - Normally Open 7 Bill Stacker - Normally Close
8 Bill Door - Normally Close 8 Bill Stacker - Common
9 Bill Door - Common 9 Bill Stacker - Normally Open
10 Bill Door - Normally Open 10 NC
11 Logic Door - Normally Close 11 NC
12 Logic Door - Common 12 NC
13 Logic Door - Normally Open
14 Ground

Recommended Connector: Recommended Connector:


Molex 22-01-3147, Crimp Terminal 08-52-0123 Molex 22-01-3127, Crimp Terminal 08-52-0123
or Tyco 1-770602-4, Crimp Terminal 770666-1 or Tyco 1-770602-2, Crimp Terminal 770666-1

The connections for SAS channels 2 and 3 come as a D-Sub 9 male connector (serial connector).

SAS Channel 3 6 SAS Channel 2 6


(Peripheral Board P210) 1
(Peripheral Board P206) 1

1 NC 1 NC
2 COM 4 / RS232 RxD 2 COM 1 / RS232 RxD
3 COM 4 / RS232 TxD 3 COM 1 / RS232 TxD
4 +5V 4 +5V
5 Ground 5 Ground
6 NC 6 NC
7 +12V 7 +12V
8 NC 8 NC
9 NC 9 NC

OXYGEN™ - Installation Manual 25


6. Bringing into Service

6.  Bringing into Service


6.1  Initial Power-up
Caution: If the machine was exposed to low temperatures, do
not power on the machine until it has acclimatized to ambient
temperature and no condensation is present.

1. Make sure that the power cable has not been damaged
during transport.

2. a) Route the power cable through the cable drop hole in


the bottom plate of the machine into the machine base.
b) If you want to use the cable access hole at the back of
the cabinet, first remove the hopper to get access to the
cable access cover. Then remove the fully closed cover and
replace it by a cover with cable recesses.

3. Make sure that the power outlet is grounded, in good con-


dition and not showing any signs of overheating or dam-
age. Then connect the power cable to the power outlet.

4. With the main door open, turn the power switch to the
“ON” position. The power up cycle will take some minutes,
because the machine checks the installed hardware, the
circuits boards firmware and security relevant circuits.

5. Check the voltage LEDs next to the corresponding fuses


on the Peripheral Board. The LED‘s should all be lit.

Proceed with the Basic Setup, as required. (RAM Clear, Initial


Setup and Service Menu settings)

For information on configuring the machine’s settings, refer


to the Software Manual for a particular software version (e.g.
Software Manual - diversity™ - (D3.0.x)) for further details.

OXYGEN™ - Installation Manual 26


6. Bringing into Service

6.2  Basic Setup


ATRONIC machines usually come configured as specified dur-
ing order processing. However it might be necessary to recon-
figure basic machine settings, such as denomination, meter-
ing, paytable, validation mode, etc. These settings can not be
altered during normal operation, as they require a machine
re-initialization for technical or jurisdictional reasons.

1. Carry out a RAM Clear


If required, carry out a critical data storage formatting us- Note: For information on configur-
ing the RAM Clear Smart Card. This will clear all machine ing the machine’s settings, refer to
data, statistics and settings, including progressive jackpot the Software Manual for a particular
configuration and allows for reconfiguration. software version (e.g. Software Man-
ual - diversity™ - (D3.0.x)) for further
2. Carry out the Initial Setup details.
After a RAM Clear the machine automatically enters the
Initial Setup menu. The Initial Setup allows to configure
basic machine setting.

3. Adjust game settings in the Service Menu


Enter the Service Menu to adjust operator selectable game
settings, such as money limits, game volume

To enter the Service Menu turn the Audit Key with the
main door open.

4. Test Money Handling


Select Diagnostics from within the Service Menu and carry
out the required tests.

5. Test Communication
Close the main door to switch to operation mode and test
the communication to the accounting system.

Note: After money handling and communication tests you may


want to carry out another RAM Clear to reset the machine statis-
tics.

OXYGEN™ - Installation Manual 27


7. Technical Support

7.  Technical Support


ATRONIC offers and provides technical support 24 hours a day, 7 days a week.

If technical assistance is required during normal business hours, please contact your local technical ser-
vices representative at one of the numbers below.

Technical Support Locations:


ATRONIC Germany (International Headquarter) (+49) 5741 24099 950
ATRONIC Peru (+51) 161 832 00

If technical assistance is required outside of normal business hours, please contact the ATRONIC Techni-
cal Hotline number below.

ATRONIC Technical Hotline:


For technical assistance in Europe,
South Africa, Asia, Central and South America
outside of normal business hours: (+49) 5741 24099 999

OXYGEN™ - Installation Manual 28

Você também pode gostar