Non-Destructive Inspection
of Storage Tanks
GINTRON!!Being one of leading suppliers of MFL inspection
equipment for steel ropes, INTRON PLUS has de-
veloped the instrument INTROCOR M-150 for
NDT of steel plates, which is applied tor inspec-
tion of tank floor. roof, wall and hull. The instru-
ment contains strong permanent magnets
which magnetize the steel plate to saturation
value. The magnetic flux travels through the
plate undisturbed. When the plate has loss of
metal due corrosion or contains cracks the mag-
netic flux is disturbed and Hall sensors acquire
this disturbance.
INTROCOR M-150 is a reliable and effective equipment to inspect integrity of storage
tanks. The tool acquires transverse oriented defects like cracks, pitting, and corrnsian In ad-
dition the instrument measures plate thickness and coating thickness. It is possible to in-
spect areas close to the plate welds.
The INTROCOR's performance corresponds to API 653 requirements. The instrument opera-
tion is based on well proved MFL inspection technology with implemented eddy-current
probes. The instrument is suited to inspect hard-to-reach areas of tank floor and roof
having practically no “dead” zone.
Ihe sophisticated software WINTKOCOR,
developed in-house, is a powerful tool to
sufficiently increase information value of
the inspection results.
After the inspection is completed the in-
spection results are handed over to the cus-
tomer along with the technical reportThe key features of INTROCOR M-150
Purpose
NDT of steel plates
Content
Principle of operation
Scarier M-150, data loyyer, softwere WINTROCOR |
Magnetic flux leakage
Control
Manual
Probes
48 Hall sensors, 3 EC probes
Thickness of steel plate
Maximum 14 mm
Test through coatings Yes
Maximum coating thickness 6mm
Scan width 150 mm
Limit of sensitivity 10% of the plate thickness
Operating speed 0-1 mis
Power supply Batteries
Test time 6 hours continuous working
Weight 21kg
Dimensions (L x W x H) 440 mm x 210 mm x 210 mm
“Dead” zone No
Inspection of liquid gas storage tank
Ves
bottom chime
Inspection of the tank wall close to tank
GINTIAON