Você está na página 1de 2

RENR7273-01

January 2011
Harness And Wire Electrical Schematic Symbols
Symbols

Pressure Temperature Level Flow Circuit Breaker


Symbol Symbol Symbol Symbol Symbol

Symbols and Definitions


Fuse: A component in an electrical circuit that will open the circuit if too much current flows
through it.

Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The
circle indicates that the component has screw terminals and a wire can be disconnected from it.

Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.

Ground (Wired): This indicates that the component is connected to a grounded wire. The
grounded wire is fastened to the machine.

Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine.

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the
contacts of a normally open reed switch; it opens the contacts of a normally closed reed switch.

312C, 315C, 318C, 322C, 325C, and T


Sender: A component that is used with a temperature or pressure gauge. The sender
measures the temperature or pressure. Its resistance changes to give an indication to
the gauge of the temperature or pressure.
330C Excavator Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.

322C, 325C, and 330C Forest Machine It has a coil that makes an electromagnet when current flows through it. The
electromagnet can open or close the switch part of the relay.

325C and 330C Material Handler Solenoid: A solenoid is an electrical component that is activated by electricity. It has a
coil that makes an electromagnet when current flows through it. The electromagnet
can open or close a valve or move a piece of metal that can do work.

Electrical System Magnetic Latch Solenoid: A magnetic latch solenoid is an electrical component that is
activated by electricity and held latched by a permanent magnet. It has two coils (latch and unlatch)
that make electromagnet when current flows through them. It also has an internal switch that places
312C: 315C: 318C: 322C: the latch coil circuit open at the time the coil latches.
BNN1-UP ANF1-UP FAA1-UP BKJ1-UP
Harness and Wire Symbols
CBT1-UP BTG1-UP HEK1-UP Wire, Cable, or Harness Harness Identification Letter(s):
DAH1-UP Assembly Identification: Includes
Harness Identification Letters and
(A, B, C, ..., AA, AB, AC, ...)
Harness Connector Serialization Code:
Harness Connector Serialization
The "C" stands for "Connector" and the
325C: 330C: 322C FM: 325C FM: Codes (see sample).
number indicates which connector in the
AG-C4 L-C12 harness (C1, C2, C3, ...).
BFE1-UP DKY1-UP BPH1-UP M2K1-UP 111-7898 3E-5179
L-C12
3E-5179
M2H1-UP G1L1-UP Part Number: for Connector Plug 1
Part Number: for Connector Receptacle

325C MH: 330C MH: CAM1-UP S3M1-UP 2

S2C1-UP D3C1-UP SLX1-UP Plug Receptacle

CBY1-UP 330C FM: Pin or Socket Number


5A
1 Deutsch connector: Typical representation
B1K1-UP of a Deutsch connector. The plug contains all Fuse (5 Amps) 9X-1123
Component
Part Number
2 sockets and the receptacle contains all pins.
B2L1-UP 325-AG135 PK-14
Sure-Seal connector: Typical representation
B3M1-UP 1
of a Sure-Seal connector. The plug and receptacle
Harness identification code:
This example indicates wire group 325, Wire Gauge
2
Air Conditioning / Heating B4N1-UP contain both pins and sockets. wire 135 in harness "AG". Wire Color

© 2011 Caterpillar, All Rights Reserved Printed in U.S.A.

(Dimensions: 25 inches x 24 inches)


RENR7273-01
12 Page,
(Dimensions: 25 inches x 24 inches)
RENR7273-01

Standard Components
Item # Components Part #
1 Temperature Sensor (Evaporator) 133-9014
2 Temperature Sensor (Fresh Air) 147-0387
3 Temperature Sensor (Recirculating Air) 147-0387
4 Temperature Sensor (Outlet Air) 147-0387
5 High Pressure Switch 189-3157
6 Low Pressure Switch 189-3156
12 Page,

7 Actuator (Air Distribution) 177-6727


8 Condenser Fan (If Equipped) 155-2269
9 HVAC Controller 171-2545
10 Actuator (Air Mix) 177-6727
11 Actuator (Air Intake) 177-6727
12 Blower Motor 177-6728
13 Control Panel 168-4605
14 Sunlight Sensor 167-7083

THIS SCHEMATIC IS FOR THE 312C, 315C, 318C, 322C, 325C, AND 330C EXCAVATOR
322C, 325C, AND 330C FOREST MACHINE
325C AND 330C MATERIAL HANDLER
AIR CONDITIONING / HEATING ELECTRICAL SYSTEM
MEDIA NUMBER: RENR7273-01
Components are shown installed on a fully operable machine with the key and engine off,
and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.