Flash Code 13 indicates that the Coolant Level Sensor (CLS) input to the ECM has dropped
below 5% (normally < 0.25 volts) of the sensor supply voltage. See Figure 13-1. This diagnostic
condition is typically:
Sensor signal is shorted to the sensor return circuit or to ground
Deteriorated coolant
The SAE J1587 equivalent codes for Flash Code 13 are p 111/4, coolant level circuit low;
(Refer to section 13.3.) and 111/6, ACLS failed low. Refer to section 13.4
[b] If terminals and connectors are not damaged, replace the CLS. Refer to section 13.3.4.
Troubleshooting 111/6, Flash Code 13 follows: Listed in Table 13-1, are the flash codes for
Add Coolant Level Sensor (ACLS) problems.
Flash PID
Description Typical Cause
Code FMI
13 111/6 ACLS failed low Signal wire (#906) shorted low (ground)
16 111/5 ACLS failed high Open or poor ground; open signal wire
43 111/1 Coolant level low (ACLS) Coolant level below probe
89 111/12 ACLS Fault Coolant reported low on main CLS, with ACLS
okay