Você está na página 1de 1

10' FOLDING PIKE POLE MOUNT 22' LITTLE GIANT STOKES STORAGE AUTO-EJECT AC CONDENSER

COLUMBIA FIRE DEPT.


POWERARC
AO-V2-M1503
BEACON
(SINGLES)
6000 PSI

LADDER CHUTE
WHELEN M9 14' COMBO R3 R2 11'-6"
R6 R5 R4
12V SCENE 16' ROOF SHELF ±2"
16' ROOF SHELF

R1
3/16" ALUMINUM

24' 2-SEC
MOUNTING PLATE

35' 2-SEC
SHELF
SHELF

A1
SLIDE-OUT
POWER ARC P14-PSK-6Y
SHELF

TRAFFIC ADVISOR

14°
SLIDE-OUT STEP
SUTPHEN SUTPHEN

W/GRIP STRUT

DIAMONDPLATE CAB ROOF HANNAY CORD REEL FRC SPECTRA


W/150' OF 10/4 240V LED SCENE

RIGID D2 LED
STOKES BOX
O

800' OF 5"
3 300 GALLON WATER TANK

D EMS
POWERARC
P14-SM-[R]

FRC SPECTRA 12V WHELEN M9 SMART POWER 8KW HYD GEN HANNAY CORD REEL FRC SPECTRA 240V
LED BROW 12V SCENE W/150' OF 10/4 LED TELE LIGHT
18"
168"

COLUMBIA FIRE DEPT.

L2
3/16" ALUMINUM
3/16" ALUMINUM L3 L4 L5 L6
MOUNTING PLATE
MOUNTING PLATE

L1 SHELF SHELF SHELF

POWERARC
C A B TILT IN ST R UC TION S

C A B TILT
IDLE PRESET
U P INC
C AB TILT LOC K

D ISE NGA GE E N GAGE SILEN CE


MO DE
DEC

D OWN

LED 210
PRIMER

PP-
8 02
HALE

POWERARC
LED 210

10°
POWERARC
P14-SM-[R]
12" 62" 194"
DUAL AIR HORNS FEDERAL Q2B SIREN 82" 236" 241"

46'-7"
DOOR OPENINGS COMPARTMENT DIMENSIONS DOOR OPENINGS COMPARTMENT DIMENSIONS
COMP'T. HEIGHT WIDTH HEIGHT WIDTH DEPTH COMP'T. HEIGHT WIDTH HEIGHT WIDTH DEPTH
L1 31 1/2 13 1/2 38 1/2 20 1/4 20 1/4 R1 31 1/2 33 1/2 38 1/2 40 27 1/2
L2 15 33 1/4 19 1/2 41 1/2 12 1/8 R2 15 33 1/4 19 1/2 41 1/2 26 1/2 TOTAL COMPARTMENT VOLUME- 265 CU FT. UPPER WARNING PACKAGE LOWER WARNING PACKAGE
L3 15 50 1/4 19 1/2 58 12 1/8 R3 15 50 1/4 19 1/2 58 26 1/2 POWER ARC LED LIGHTBAR POWER ARC LEDS
L4 40 1/2 38 3/4 48 1/2 45 3/4 26 1/2 R4 40 1/2 38 3/4 48 1/2 45 3/4 26 1/2 DOOR OPENINGS COMPARTMENT DIMENSIONS POWERARC LED BEACONS
L5 40 1/2 15 1/8 48 1/2 22 26 1/2 R5 40 1/2 38 3/4 48 1/2 45 3/4 26 1/2 COMP'T. HEIGHT WIDTH HEIGHT WIDTH DEPTH
L6 32 1/8 30 7/8 40 1/8 34 3/4 26 1/2 R6 32 1/8 30 7/8 40 1/8 34 3/4 26 1/2 A1 9 1/8 24 1/2 9 7/8 26 88
DIMENSIONS SHOWN ON THIS DRAWING ARE
CUSTOMER APPROVAL
DRAWN BY:
F UPDATES TO DWG AND CLARIFICATION NOTES ; SEE SO REVISION EMAIL FOR COMPREHENSIVE LIST RM 02/19/18
APPROXIMATE AND ARE SUBJECT TO MINOR R.MILLER
DEVIATIONS DURING CONSTRUCTION. E COMPONENTS ON RIGHT SIDE BODY TOPS HAVE BEEN REARRANGED FOR CLEARANCE ; OTHER MINOR CLARIFICATIONS RM 01/30/18
IN THE EVENT OF A DISCREPANCY BETWEEN THE NAME: DATE:
D MULTIPLE UPDATES, SEE SHOP ORDER REVISION EMAIL OR COMPONENT REPORT BELOW RM 11/04/17
SUTPHEN SPECIFICATIONS AND DRAWING, THE 08/10/17 COLUMBIA FIRE DEPARTMENT
SUTPHEN SPECIFICATIONS SHALL PREVAIL. TITLE: C MOVED SHORELINE INLET LOCATION ; ADDED CALL-OUTS FOR TIRE CHAINS AND ASR DISCN'T SWITCHES RM 10/13/17 COLUMBIA, MO
MFG. FACILITY:
DRAWING IS FOR REFERENCE ONLY. SOME ITEMS REV. DESCRIPTION BY DATE SPH100 AERIAL PLATFORM
PROPOSED MAY NOT BE SHOWN OR NOTED. DATE: THIS PRINT IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTEREST OF SUTPHEN CORPORATION.
DUBLIN
DWG. NO.: HS-6108

Você também pode gostar