Você está na página 1de 1

ALUMINUM HOSEBED COVER 2-1/2" DIRECT TANK FILL

2-1/2" DISCHARGE WHELEN L31 RED BEACONS 3" DISCHARGE (2) 2" CROSSLAYS

2-1/2" PRE-CONNECT 2-1/2" DISCHARGE FRC FOCUS 240V/750W TELES

FRC SPECTRA 12V FIXED SCENES

24' 2-SECTION
14' ROOF LADDER
10' FOLDING LADDER
(3) PIKE POLE TUBES R3 R2 R1
BACK BOARD STORAGE 9'-8"
±2"
SHELF SHELF

60" SHELF

A1
81"
5' - 8"
57" 600# TRAY

11° 14°
SUTPHEN SUTPHEN
120VAC 44"

RUNNING BOARD HOSE TROUGHS 3" DECK GUN DISCHARGE

CORD REEL
77"
LEFT SIDE COMPARTMENTATION
COMPT DOORS OPENING DIMENSIONS INSIDE DIMENSIONS VOLUME
L1 DOUBLE 24 3/4"w X 62 3/4"h 28 3/4"w X 66"h X 27 1/4"d 30 CU. FT.
O 2 6
L2 LIFT-UP 57 1/2"w X 32 1/4"h 61 1/2"w X 36 1/2"h X 27 1/4"d 30 CU. FT.
L3 DOUBLE 48 1/2"w X 62 3/4"h 53 1/2"w X 66"h X 27 1/4"d 55 CU. FT.

RIGHT SIDE COMPARTMENTATION


550' OF 5"
COMPT DOORS OPENING DIMENSIONS INSIDE DIMENSIONS VOLUME
EMS 550' OF 2-1/2"
R1 DOUBLE 24 3/4"w X 62 3/4"h 28 3/4"w X 66"h X 27 1/4"d (10 1/2"d upper) 20 CU. FT.
550' OF 2-1/2"
R2 LIFT-UP 57 1/2"w X 32 1/4"h 61 1/2"w X 36 1/2"h X 10 1/2"d 13 CU. FT.
R3 DOUBLE 48 1/2"w X 62 3/4"h 53 1/2"w X 66"h X 27 1/4"d (10 1/2"d upper) 43 CU. FT.
250' OF 1-3/4"

REAR STEP COMPARTMENTS


COMPT DOORS OPENING DIMENSIONS INSIDE DIMENSIONS VOLUME
D 1 5
A1 ROLL-UP 37 1/2"w X 37"h 46"h X 40"w X 30 1/2"d 33 CU. FT.
TOTAL: 224 CU. FT.

1,000 GALLON WATER TANK

WHELEN PFP2 WHELEN FREEDOM IV SMART POWER GENERATOR


12V LED BROW LED LIGHTBAR
AIR CONDITIONING TWO-TONE CAB PAINT 2-1/2" DISCHARGES BOOSTER HOSE ROLLERS

BREAKER PANEL

L1 L2 L3
87"
AUTO

SLIDE-OUT / TILT-DOWN DRAWER


EJECT

SHELF SHELF

WHELEN LED
IDLE PRESET INC

S I
LE NCE
MODE DEC

TURN SIGNALS SHELF SHELF

WHELEN 600
RED LEDS 600# TRAY 600# TRAY

12" 18"
FEDERAL Q2B AUTO EJECT 62" QMAX-1500

DUAL AIR HORNS (2) SIREN SPEAKERS 82" 173" 106"


30'-1"

DIMENSIONS SHOWN ON THIS DRAWING ARE


CUSTOMER APPROVAL
DRAWN BY:
E POST PRODUCTION REVISION TO REFLECT FINAL PRODUCT RM 05/31/18
APPROXIMATE AND ARE SUBJECT TO MINOR R.MILLER
DEVIATIONS DURING CONSTRUCTION. D RADIO AND ANTENNA CLARIFICATIONS RM 05/08/18
IN THE EVENT OF A DISCREPANCY BETWEEN THE NAME: DATE:
C SEVERAL CLARIFICATIONS - SEE SO REVISION EMAIL OR COMPONENT REPORT BELOW RM 04/18/18
SUTPHEN SPECIFICATIONS AND DRAWING, THE 08/02/17 DURHAM FIRE DEPARTMENT
SUTPHEN SPECIFICATIONS SHALL PREVAIL. TITLE: B CHANGED TO A TRIANGULAR TOP OVER EMS CABINET RM 11/08/17 DURHAM, NC
MFG. FACILITY:
DRAWING IS FOR REFERENCE ONLY. SOME ITEMS REV. DESCRIPTION BY DATE CUSTOM PUMPER - S2/S4 SPECIAL DURHAM BODY
PROPOSED MAY NOT BE SHOWN OR NOTED. DATE: THIS PRINT IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTEREST OF SUTPHEN CORPORATION.
DUBLIN
DWG. NO.: HS-6097