Você está na página 1de 44

H13-511 (154 Questions)

Number: 000-000
Passing Score: 800
Time Limit: 120 min
File Version: 1.0

Vendor: HUAWEI

Exam Code: H13-511

Exam Name: HCNA-Cloud-BCCP (Building Cloud Computing Platform)


Innovior ITTech

Q&A

HCNA-Cloud-BCCP (Building Cloud Computing Platform)


H13-511

(154 Questions)

http://www.facebook.com/InnoviorITTech

We Offer Free Update Service


For One Year.

Sections
1. (none)
QUESTION 1
The failure of install multipath is mostly due to compatibility, which components mainly needs to consider
compatible when install multipath? (Select three Answers)

A. with OS specific version


B. with HBA card
C. server system hard disk drive
D. with iSCSI initiator software

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 2
How to troubleshooting whether there is impact performance of failure hard disk in storage system (slow)?

A. under CLI check RAID LUN state, whether if it is abnormal


B. in storage debug mode, through the command of iostat x d 1 to check IO of storage system, the average
service time of some disk (svctm) over a period of time is obviously more than other disk, %util is close to
100%, and other disk are free, can judge the hard disk performance
C. on host side check LUN IO state under multipath
D. check the link state in host side and ISM storage interface

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 3
About storage network management software, which description is wrong?

A. equipment management can manage storage array device


B. business management, business flow management
C. topology display, visual display device of the current topology connectionstatus
D. DHA service management, hard disk health data/performance data

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 4
For backup and disaster, what size of striping depth are recommended the common used?

A. 8K
B. 16K-128K
C. 64K
D. more than 64K

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 5
Which of the following command can check kernel version information in linux system?

A. showname
B. uname -a
C. ls
D. linux-release

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 6
In the synchronous remote copy of storage array, if copy link break, will lead to the corresponding business
interruption in host.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 7
When add LUN from S5000T configured asynchronous remote replication, Set the type to " timer wait begin at
the same time " Timing length is 720 minutes " Assuming 10:00 start synchronization, Synchronization process
takes 100 minutes, so what is the time for the start of the next synchronization?

A. 23:40:00
B. 22:00:00
C. next day at 11:40
D. next day at 10:00

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:
QUESTION 8
Multipath install failure in Windows platform in the case of old version do not completely uninstall, which of the
following method can solve the problem? (Select two Answers)

A. delete the current setup of UltraPath for Windows, restart the host and reinstall.
B. in the registry search 'UltraPath' registry key, delete the related keyvalues of UltraPath in registry
C. run Setup.exe in installation disk of SUPPORT\TOOLS, install reg.exe registry program
D. The PATH variable value in system add "%SystemRoot%\system32; %SystemRoot%" and reinstall

Correct Answer: AB
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 9
Compared with SCSI protocol in the actual application, which belongs to the advantage of the iSCSI? (Select
three Answers)

A. the cost is low


B. make full use of TCP/IP network
C. need parallel transmission cables
D. long transmission distance

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 10
Arbitration ring topology can extend the maximum number of equipment is ? (not include its node)?

A. 128
B. 127
C. 126
D. infinite

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 11
The operation process of the incremental of LUN copy in storage array, which is correct?

A. create LUN copy- > create resource pool- > select the source array and the source LUN- >select the target
array and the target LUN- > start LUN copy
B. create LUN copy- > select the source array and the source LUN- > select the target array and the target
LUN- > create resource pool- > start LUN copy
C. create resource pool- > create LUN copy- > select the source array and the source LUN- > select the target
array and the target LUN- > start LUN copy
D. all above statement are wrong

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 12
Create RAID group through SATA, two controllers at the same time can access to RAID groups may cause
degradation of the performance, what is the solution?

A. adjust LUN belong to the same controller of the same RAID group
B. adjust LUN writing strategy
C. upgrade multipath software
D. upgrade controller version

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 13
Incremental LUN copy about storage array, which of the following are correct? (Select two Answers)

A. support third-party array to third-party array


B. support huawei array to other manufacturers array
C. support copy in S5000 and S2600 array
D. don't support copy in S5000T and S5000 array

Correct Answer: BC
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 14
when SAN storage array power up, enter into MML mode, sys status check System Running Status: ( normal
mode ) normal mode shows power up successful for the system.If it is not normal mode, can judge power up
failure for the system.This judgment method of system startup anomaly is correct.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:
QUESTION 15
After the host start multipath failover, what abnormal phenomena may have?

A. ping-pong effect
B. can't eliminate the shadow of disk
C. path can't switch
D. system will turn blue

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 16
Two reliability for 80% of the components of a serial system, how much reliability of this system?

A. 64%
B. 60%
C. 80%
D. 96%

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 17
In IP SAN network, eliminates the iSCSI storage and iSCSI host business IP network is unable to connect.The
main screen from which several aspects? (Select two Answers)

A. host iSCSI initiator file configure error


B. iSCSI initiator service did not start
C. LAN configuration if it is reasonable
D. configuration of IP, gateway and mask are reasonable

Correct Answer: CD
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 18
For S5000V1R2 old version, appear RAID fault, suggest to check its system have BST function, without this
feature, often need to upgrade the version with BST function (V1R5)

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 19
For solaris system, which of the following statement about STMS is true? (Select 3 Answers)

A. solaris 10 system can bring its own STMS package, do not need additional install.
B. use the command to enable port of STMS function will ask to restart the host
C. stmsboot is management programs of manage solaris multipath characteristiC.
D. install Ultrapath multipath software to support multipath function on the solaris

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 20
what are the main difference between optical fiber topology FC-AL and FC-SW? (Select three Answers)

A. topological structure of FC-AL is network, topological structure of of FC-SW is circular


B. FC-AL use AL-PA query equipment, FC-SW use Name Server query equipment
C. when there is new equipment join in, FC-AL need to interrupt network, FC-SW don't need to interrupt the
network
D. FC-AL through the hub as connection device, FC-SW optical switches as connected devices

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 21
About storage array resource pool the following error:

A. LUN in resource pool can mapping to host at the same timE.


B. LUN in resource pool in use process can't be deleted
C. Don't delete the snapshot and directly deleted the source of LUN
D. the affiliation of LUN belongs to the affiliation of the source of LUN

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 22
About the iSCSI protocol, which description of the following are right? (Select three Answers)

A. iSCSI is based on IP protocol proposed by Microsoft technical standards


B. iSCSI support users through its access IP SAN storage network
C. iSCSI essence is SCSI commands and data transmission in IP frame format
D. iSCSI protocol based on SCSI and TCP/IP

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 23
About virtual snapshot storage array configuration, which of the following statement are wrong? (Select 3
Answers)

A. snapshot function can not use the resource of LUN


B. can create a snapshot of two LUN
C. activate snapshot is the true copy of data
D. snapshot can be used to rollback after stop

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 24
Which are the common commands in the state of check storage side system?(Select 3 Answers)

A. showctrlinfo
B. showsys
C. showrg
D. showraid

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 25
Under the condition of Web application, Email, database application etc small file read and write , SAN
performance is mainly determined by the bandwidth.In vedio, survey and draw etc large files continue to read
and write condition, SAN performance is mainly determined by IOPS.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 26
which command can view the disk normal identified under solaris system?

A. lspv
B. format
C. fdisk
D. lsdev

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 27
At the core of performance in storage system, which of the following indicators are: (Select two Answers)

A. IOPS
B. volatility
C. bandwidth
D. the response time

Correct Answer: AC
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 28
Main technical or functional of S5000T storage systems to enhance the reliability of the data are cache may fall
protection, disk copy, global hot standby disk.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 29
In FC arbitration ring architecture, when the device is join or exit, do not have effect on other devices of the
ring.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 30
IP SAN network, what are the common faults?(Select 3 Answers)

A. IP can't be connected
B. port restriction
C. VLAN Set is not reasonable
D. FC port lack of light power

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 31
Multipath operation process is abnormal in Windows platform, which log files is suggested to main analysis?

A. cfg file
B. UPLOG_x.txt
C. InstallationLog.txt file
D. UPLOG.txt

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 32
For system performance test, what kinds of the tools are divided into? (Select three Answers)

A. benchmark test tools


B. business test tools
C. IO test tools
D. data consistency test tools

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 33
High Availability cluster, called HA cluster for short, this kind of cluster is committed to provide high
performance services

A. True
B. False
Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 34
The following which do not belong to the methods to improve the reliability of the data stored?

A. component redundancy
B. hot standby dis technology
C. cache mirroring technology
D. smart prefetching technique

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 35
About iSCSI protocol implementation of three parts, which describe are right? (Select three Answers)

A. initiator Portal: provide connection iscsi storage device and ISCSI packet parsing and the driver of data
reading andwriting.
B. Target Portal: iscsi storage devices, provide data storage services
C. Portal: by IP address and port (default of iSCSI is TCP3260), through the Portal to provide connectivity and
services
D. initiator Portal: iscsi storage devices, provide data storage services

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 36
When create copy of LUN, if the size of the source LUN is 500G, then the LUN of remote array capacity under
the target can't be used for copy of LUN.(Select 2 Answers)

A. 300G
B. 400G
C. 500G
D. 600G

Correct Answer: AB
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:
QUESTION 37
OceanStor storage under the condition of a fan module fault, another fan module automatically improve speed,
guarantee temperature can controll under single fan module, at this time also need to replace the fault fan in
timE.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 38
iSCSI of IP SAN storage array provide security function of CHAP authentication to prevent unauthorized
access; IPsec prevent insert, modify, and delete, and prevent eavesdrop, ensure the privacy.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 39
Which of the following components do not belong to FC SAN network hardware?

A. HBA card
B. switches
C. storage device
D. server mainboard

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 40
Through which two ways can detect the hard disk bad way in OceanStor storage system? (Select two
Answers)

A. read/write failure automatic analysis


B. hard disk medium active scan
C. power test
D. business data flow anomaly detection

Correct Answer: AB
Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 41
Remote copy link between array according to transport protocol is divided into which several? (Select three
Answers)

A. parallel link
B. cross link
C. FC link
D. iSCSI link

Correct Answer: CD
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 42
check host already registered iSCSI target and the command is: iscsiadm -m node on Linux platform

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 43
About iozone and iometer, which are true? (Select two Answers)

A. iometer support graphical configuration interface


B. iometer is mainly used to test the performance of file system
C. iozone can only use the command line configure interface
D. iozone is mainly used to test the performance of block device

Correct Answer: AC
Section: (none)
Explanation

Explanation/Reference:
Section: (none)
Explanation

Explanation/Reference:

QUESTION 44
Hyper replication technology of Storage array is usually based on block level of replication.

A. True
B. False
Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 45
Remote replication between storage array is based on the copy file level

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 46
About snapshot, LUN copy and remote replication on array, which of the following are true ? (Select 2
Answers)

A. A. Can do LUN snapshot and replication on a array


B. a remote copy of the source LUN can be used as another remote replication target LUN
C. a remote copy of the source LUN can be used as another one copy of the sourceLUN
D. can't do a snapshot and replication on a array

Correct Answer: AC
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 47
Two criteria based on SMI: CIM (Common Information Model) and WBEM (Web Based Enterprise
Management)

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 48
The SAN network topology, which is the relatively high reliability?

A. directly connected network


B. double exchange network
C. single exchange network
D. multipath network

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 49
The maximum single size of Host FC-HBA card request do not exceed 4096M

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 50
Below the write Cache strategy description about the array is not the right are:

A. write-through cache suggest mirror mode, in order to improve data reliability


B. Write Back cache can improve SAN performance
C. Write Back cache no matter whether to adopt the mirror, random write performance almost no difference
D. write-through cache, bottle neck area of SAN performance often on the disk

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 51
What is the command to check WWN number of FC-HBA card in AIX system?

A. lscfg -pvl fcs0


B. hba
C. lsdev -Cc adapter |grep fcs
D. hbainfo

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 52
Which of the following HostAgent components need to restart the host after the installation is complete?
A. HyperManager server
B. InbandAgent
C. ConsistentAgent
D. HyperManager client

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 53
What the common timing index in measure a system reliability? (Select two Answers)

A. reliability
B. efficient
C. the average of failure time
D. the average of fault-free time

Correct Answer: CD
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 54
Configure LUN copy in S5000, the capacity of target LUN in LUN copy must be greater than or equal to the
source LUN capacity.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 55
The most important three part of SAN network in technically: device interfaces (E. g, SCSI, fiber channel and
ESCON, etC. ), connection device (switches, gateway, router and Hub, etC. ) and communication control
protocol (E. g iSCSI and FC, etC. ) the three components plus additional storage devices and servers,
constructed SAN system from the component, the SAN can be divided into host,HBA, switches, storage
devices of the two is not match.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 56
LUN copy in storage array do not support copy a source of LUN to two goal LUN at the same time

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 57
ISCSI is based on TCP/IP protocol, the default service port is?

A. 3260
B. 8088
C. 8443
D. 3206

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 58
Active-Active work mode: normally called double living mode, two controllers are in activation state, parallel
processing the I/O requests from the application server, once a controller failure or offline, another controller
will take over his work in time, and shall not affect its current task.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 59
About the storage array, which LUN copy function is true? (Select two Answers)

A. when create LUN copy , you can use one virtual snapshot of LUN as the source of LUN
B. when create increment LUN copy, you can use external array as the source of LUN
C. when create full capacity of LUN copy, the source of LUN and target of LUN can't be located in the external
array at the same time
D. multiple LUN copy can share same target of LUN

Correct Answer: AC
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 60
For AA model storage controller, STMS in solaris OS can realize Failback function.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 61
An N8500 clustered NAS engine does not need to be equipped with power modules.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 62
An application requires high write performance and moderate reliability. To ensure that the N8500 clustered
NAS storage system delivers the optimal write performance, set the LUN write policy to write back with
mirroring.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 63
Which of the following statements about the file pool and file pool policies of the OceanStor 9000 is incorrect?

A. One file can belong to different file pools,


B. File pool policies come with priorities. For files, only the file pool policy of the highest priority takes effect.
C. The characteristics of a file pool are in an AND relationship.
D. File pool policies are available only after the InfoTier license is activated.

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 64
The networking of an HUAWEI OceanStor 9000 big data storage system includes which of the following?
(Select 3 answers)

A. Front-end service network


B. Back-end storage network
C. Internal communication network
D. IPMI management network

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 65
The OceanStor 9000 WushanFS supports online node expansion. The storage capacity and computing
capability are increased linearly, providing linearly increasing throughput and concurrency capabilities for
users.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 66
It is recommended that the OceanStor 9000 use 10GE for both the front-end and back-end networks.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 67
In an N8500 clustered NAS system, the Veritas Volume Manager (VxVM) is located between the operating
system and the data management system. The VxVM accesses disks using the interface provided by the
operating system, makes the physical storage devices connected to hosts invisible, and provides a logical
device layer for the data management system. The logical devices on this layer are called VxVM volumes.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 68
The OceanStor 9000 can be installed in a Huavvei-supplied cabinet only,

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 69
Which of the following statements about reading and writing an N8500 clustered NAS file system mirror and
the best practices are correct? (Select 3 answers)

A. Equivalent to RAID 01, Mirrored-stripe is to perform file system mirroring based on striping, A mirror
provides data redundancy, and data is distributed across multiple disks.
B. Mirror is equivalent to RAID 1, Data that needs to be written to a file system is simultaneously written to two
mirrors and data is read from the two mirrors based on a round-robin policy (I/Os are evenly distributed to
paths in a round-robinmanner).
C. Regarding the use of Mirror, it is recommended that the space of the source file system be provided by one
storage array and that of the mirrored file system be provided by another. Mirror is recommended for
scenarios that require high reliability.
D. Mirrored-stripe is suitable for scenarios that require high reliability. The performance of Mirrored-stripe is
the same as that ofMirror.

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 70
The figure shows the rear view of a P node in an OceanStor 9000. When its front-end is a 10GE network and
its back-end is an IB network, NICs 0 on all nodes in the basic cabinet must be connected to the GE switches
in the same cabinet.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 71
Which data protection levels can be configured for an OceanStor 9000 storage system that consists of 10
nodes? (Select 2 answers)

A. RAID1
B. 6+3
C. 6+4
D. 6+5

Correct Answer: BC
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 72
When you are using the OceanStor Toolkit to deploy an OceanStor 9000 storage system, you must configure
the front-end network mask, front-end network gateway, back-end network mask, back-end network gateway,
management network mask, and management network gateway in the configuration file of the OceanStor
Toolkit.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 73
An N8500 clustered NAS system has many services that help implement system functions, such as NFS and
CIFS basic service groups. Which of the following is not a resource agent of the NFS service group?

A. NIC
B. Hashadow
C. Disk
D. IP

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 74
When an engine node of an N8500 clustered NAS storage system needs to connect to multiple ports on a
controller of a storage unit, ensure that ports on different interface modules are used.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 75
Which of the following statements about the file sharing protocols of the OceanStor 9000 are correct? (Select 3
answers)

A. The OceanStor 9000 supports NFS and CIFS file sharing protocols.
B. The OceanStor 9000 is compatible with various operating systems, allowing file resource sharing in a
heterogeneous network environment.
C. The sharing is by files.
D. The sharing service supports automatic load balancing.

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 76
You are required to check the installation environment before installing software on an OceanStor 9000
storage system. Which of the following conditions does not meet these requirements?

A. The OceanStor 9000 consists of three P nodes and one C node.


B. The storage nodes run SU5E Linux Enterprise Server 11 (x86_64) SP1.
C. The PC used for installation runs Windows 7.
D. The PC used for installation runs Internet Explorer 9.

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 77
Which of the following statements about the VxVM implementation mechanism employed by an N8500 are
correct? (Select 2 answers)

A. The capacity of a physical disk and that of a virtual disk are the same.
B. A plex consists of virtual disks.
C. A volume consists of subdisks.
D. The capacity of a volume can be larger than the maximum capacity of a single physical disk.

Correct Answer: AD
Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 78
Which of the following statements about the InfoTier feature of the OceanStor 9000 are correct? (Select 2
answers)

A. The InfoTier license must be purchased.


B. This feature can be used only when the storage system has different types of nodes.
C. This feature can be used when the storage system has different types of disks.
D. After this feature is enabled, you can set the high and low watermarks for a specified node pool.

Correct Answer: AB
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 79
If the file system sharing services are interrupted on an N8500 storage system, which of the following
information must be collected for troubleshooting? (Select 3 answers)

A. Alarm information
B. Operations performed after the fault occurred
C. Clustered NAS configuration information
D. Number of storage unit disk enclosures

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 80
In an OceanStor 9000 storage system, the management IP address is 100.16.100.3, the front-end service
network segment is from 192.168.100.1 to 192.168.100.20, the dir00l directory is shared, and the share path is
/dir00l. Which of the following statements about the share access are correct? (Select 2 answers)

A. The clients that attempt to access the share must interwork with IP address 100.16.100.3.
B. The clients that attempt to access the share must interwork with any IP address in the network segment
from 192.168.100.1 to 192.168.100.20.
C. If the client runs the 5U5E operating system, use the mount -t nfs ipaddress:\dir001 \mnt command to
mount theshare.
D. If the client runs the SUSE operating system, use the mount -t nfs ipaddress:/dir001 /mnt command to
mount theshare.

Correct Answer: BD
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 81
When using the OceanStor Toolkit to deploy an OceanStor 9000 storage system, the IP addresses specified in
IP address segment in the Configure DHCP area can only be use for the deployment. After the deployment is
successful, the IP addresses of each node are changed to those as planned in the configuration file.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 82
In an OceanStor 9000 storage system, the calculate quota is set to 50 GB for user A to access the /dir
directory. When the amount of data that user A writes exceeds 50 GB in the /dir directory, the system allows
user A to continue to write data in the /dir directory.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 83
Which of the following interface cards can be installed in the PCIe expansion slot on the P node of the
OceanStor 9000? (Select 3 answers)

A. 2-portTOE 10GE network adapter


B. 2-port IB network adapter
C. 2-port GE network adapter
D. 2-port 8 Gbit/s Fibre Channel interface card

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 84
Which of the following statements about the 10 Gigabit Ethernet (10GE) is incorrect?

A. 10GE, an Ethernet transmission standard, become IEEE Std 802.3ae-2002 in 2002.


B. 10GE enables an Ethernet to transmit data at a rate of 10 Gbit/s, 10 times the rate of GE.
C. 10GE defines full-duplex and half-duplex links which are generally connected by network switches.
D. 10GE implements access at a high bandwidth and low latency. 10GE is suitable for scenarios such as
media & entertainment, high-performance computing, and OLAP.

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 85
If the InfoLink license is not activated in an OceanStor 9000 storage system, the system cannot balance loads
coming from clients.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 86
If an OceanStor 9000 storage system consists of three P nodes and uses GE for the front-end network, how
many IP addresses must be planned for the front-end service network segment?

A. 17
B. 18
C. 19
D. 20

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 87
Which of the following statements about NewSQL databases are correct? (Select 3 answers)

A. MPP databases are not NewSQL databases.


B. NewSQLdatabases have the capability to store and manage massive data.
C. NewSQLdatabases support ACID and SQL as traditional databases do.
D. NewSQLindicates various new databases that provide scalability and high performance.

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 88
If the back-end storage performance of an N8500 storage system deteriorates, which of the following items
can be skipped during troubleshooting?

A. Whether the sharing services are disabled


B. Whether the batteries on the storage units are faulty
C. Whether a link between the engine and a storage unit is down
D. Whether the storage system has slow disks

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 89
In an N8500, metadata is classified into many types. Different nodes process different types of metadata.
Metadata is classified into which of the following types? (Select 3 answers)

A. Super block
B. Log area
C. Allocation unit
D. Folder

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 90
The figure shows the file pool policy configured for an OceanStor 9000 storage system. The monitoring and
migration time is 2: 00-4: 00 a.m. every day. At 9: 00

A. m. on Monday, file A was created in the \example\test directory. By 10: 00 a.m., file A had been read and
written for 15 times and the file size became 150 MB.
After that, file A was no longer accessed. At 9: 00 a.m. on Tuesday, in which tier is file Astored?
B. Small-data tier
C. High-performance tier
D. High-bandwidth tier

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 91
Which of the following file system configurations are correct for the N8500 clustered NAS storage systems?
(Select 2 answers)

A. Set not more than 16 columns in a stripe file system to prevent serious data discretization.
B. Set a block size to 8192 when the file system size is larger than 1TB.
C. Set the number of columns consistent with that of RAID groups for a stripe file system,
D. You are advised to disable quotas if the number of files exceeds 40 million.

Correct Answer: BC
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 92
An N8500 clustered NAS storage system cannot be logged in to using the master account. Which is the
possible cause?

A. The console IP address conflicts with another IP address on the network.


B. The network port corresponding to the console IP address is not connected to a network cable or is in the
shutdown state.
C. The user name and password have been changed.
D. A heartbeat link is down.

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 93
Which of the following are characteristics of big data? (Select 3 answers)

A. Huge data volume


B. Authentic and valid data
C. Fast data circulation
D. Various data types

Correct Answer: ACD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 94
An OceanStor 9000 storage system is deployed using the OceanStor Toolkit. Which of the following
statements about the settings of the OceanStor Toolkit configuration file are correct? (Select 2 answers)

A. The cluster name can be set to 9000cluster.


B. If the InfoLink license has not been purchased, you may skip the InfoLink DNS configuration.
C. The front-end network gateway will serve as the default gateway of all storage nodes after beingconfigured.
D. The data redundancy ratio is the default ratio of all directories on the OceanStor 9000.

Correct Answer: CD
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 95
Which of the following network file sharing protocols are supported by a NAS storage system? (Select 2
answers)
A. FAT32
B. NTFS
C. NFS
D. CIFS

Correct Answer: CD
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 96
In an N8500 clustered NAS system, which of the following commands are commonly used to query a cluster's
detailed resource information? (Select 2 answers)

A. hares -state
B. hares -display
C. hagrp -dep
D. hagrp -state

Correct Answer: AB
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 97
In the OceanStor 9000, a node pool is a collection of nodes that have the same characteristics such as
physical type and access performance, and DST allows a user to divide physical nodes in the same file system
into node pools.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 98
Which of the following can be used to manage secure access to NFS shares? (Select 2 answers)

A. AD
B. NIS
C. LDAP
D. Homedir

Correct Answer: BC
Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 99
The three mainstream storage forms are as follows: 1)SAN storage that provides block resources;
2)NAS storage that provides file system resources;3) object-based storage (OBS). SAN storage and NAS
storage are traditional storage forms. Which of the following statements about the characteristics of the three
storage forms are correct? (Select 3 answers)

A. In traditional storage forms, disks are partitioned, file systems record file structures based on a tree
relationship, and metadata is used to identify the use of blocks.
B. Objects are the basic units of OBS. Each object is a composite of data and data property sets.
C. In the OBS mechanism, data and metadata are stored and managed in a distributed manner.
D. OBS is typically oriented to structured data applications.

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 100
In an N8500 clustered NAS system, underlying virtualization is implemented by the VxVM component. The
virtual objects managed by the VxVM are VM disks, disk groups, subdisks, and plexes. Which of the following
statements is incorrect?

A. A VM disk is controlled by the VxVM and typically located in a disk group. Each VM disk corresponds to at
least one physical disk or disk partition.
B. A disk group is a collection of VM disks.
C. A subdisk is the basic unit for the VxVM to allocate disk space. To improve the efficiency of underlying
resource use, a subdisk can be a group of inconsecutive disk blocks.
D. A plex consists of one or multiple subdisks on one or multiple physical disks. Each plex contains a
duplicate of the data selected in a volume.

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 101
The license must be purchased for which of the following software features of the OceanStor 9000? (Select 3
answers)

A. WushanFS
B. InfoLink
C. InfoQuota
D. InfoTier

Correct Answer: BCD


Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 102
If the name of a shared directory is dirtest in an OceanStor 9000 storage system, local users who have
permission can access the directory by entering \\*.*.*.* \dirtest, where *,*.*,* must be the front-end service IP
address of the node that provides storage space for the dirtest directory.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 103
Which of the following storage services can the N8500 clustered NAS system that employs the integrated
networking mode provide for application servers? (Select 3 answers)

A. CIFS
B. 10 Gbit/s iSCSI SAN
C. SASSAN
D. FCSAN

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:
Section: (none)
Explanation

Explanation/Reference:

QUESTION 104
Which of the following statements about the login information of the OceanStor 9000 after its software
installation is complete are incorrect?

A. The account and default password for logging in to the OceanStor DeviceManager are admin and Admin
@storagerespectively.
B. To log in to the OceanStor DeviceManager from Internet Explorer, enter https://xx.xx.xx.xx:8088, where
xx.xx.xx.xx is the management IP address of the OceanStor 9000.
C. The default password for the default account root of the Linux operating system running on a storage node
isroot@storage.
D. To log in to the IPMI of a storage node on Internet Explorer, enter https://xx.xx.xx.xx, where xx.xx.xx.xx is
the IP address of the IPMI port on the storage node.

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:
QUESTION 105
The master account is used to enter the CLI mode of N8500 V200R001. Which of the following operations can
be performed related to NFS? (Select 3 answers)

A. nfs server show


B. nfs server status
C. nfs server start
D. nfs server stop

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 106
A customer's OceanStor 9000 big data storage system uses GE for the front-end network and 10GE for the
back-end network. If the OceanStor 9000 is configured with four C nodes, only a basic cabinet is required.

A. TRUE
B. FALSE

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 107
For one or more Windows clients to access the storage resources on an OceanStor 9000 storage system, the
administrator needs to create a directory under the root directory on the specified storage node and authorize
the new directory to the target user or user group.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 108
The OceanStor 9000 can be installed in a Huawei-supplied cabinet only.

A. TRUE
B. FALSE

Correct Answer: B
Section: (none)
Explanation
Explanation/Reference:
Explanation/Reference:

QUESTION 109
The OceanStor 9000 allows users to define file pool polices based on file attributes and I/O frequency. Which
of the following statements about file pool polices are correct? (Select 3 answers)

A. A create policy is used to determine the initial location where a newly created file is to be stored. Such a
policy includes the following items:file storage path, file name, and UID/GID
B. A relocate policy is used to determine the target location where a file is to bemigrated.
C. A delete policy is used to determine when to delete a file from the system.
D. A modify policy is used to determine how to modify afile.

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 110
Which of the following statements about the intelligent load balancing feature of the OceanStor 9000 are
correct? (Select 3 answers)

A. Performance is balanced among all nodes. Capacity cannot be balanced among all nodes.
B. Nodes can be divided into zones. An independent load balancing policy and an independent domain name
can be configured for each zone.
C. Load balancing policies can be based on CPU usage, memory usage, bandwidth usage, number of
network connections, and/or node capability.
D. The OceanStor 9000 provides the load balancing service based on round robin, CPU usage, or the number
of connections to a node.

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:
Explanation/Reference:

QUESTION 111
In Huawei FusionSphere, a new snapshot is created for the VM. This snapshot can save information about all
disks of the VM.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 112
The administrator adds a storage interface to the host in FusionCompute to achieve the docking of host and
storage device. Which of the following storage types do not need to add a storage interface? (Multiple
Choices)

A. FC-SAN storage
B. IP-SAN storage
C. Local hard disk
D. Local memory disk

Correct Answer: ACD


Section: (none)
Explanation

Explanation/Reference:

QUESTION 113
When installing FusionCompute, which of the following is the proper order of installation?

A. First install the VRM on a physical server, and then add the host through VRM. After the host is added
successfully, it is the CNA host.
B. Install the CNA host first, then install the Installer on the CNA host and install the VRM through the Installer
C. Install the Installer on the PC first, then install the CNA host and VRM through the Installer
D. Use mirroring to install the server as a CNA host, and then use commands to create a VRM virtual machine
on the host.

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:

QUESTION 114
In Huawei FusionSphere, what kind of storage resource is added to a host, then one disk of a VM corresponds
to one LUN in the storage? (Multiple Choices)

A. FusionStorage
B. Advanced SAN
C. FC-SAN
D. IP-SAN

Correct Answer: AB
Section: (none)
Explanation

Explanation/Reference:

QUESTION 115
In FusionSphere, each VM can have multiple virtual network interface cards.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 116
When creating a port group in FusionCompute, which of the following operation is wrong?

A. Set the name of the port group as "ceshi"


B. Set the port type as "Normal"
C. Set VLAN ID as "5000"
D. Add "This is a test port" in the description

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:

QUESTION 117
Where can be the DRS function enable on the FusionCompute?

A. Cluster
B. Host
C. Virtual Machine
D. Operating System

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 118
It can set the MTU value as 10000 in FusionCompute networking pool.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 119
In FusionCompute, clonal VMs and cloned VMs have the same configuration at the time of cloning, but they do
not have the same data.

A. True
B. False

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 120
Cloud computing is defined as a model, not just as a technology. This model can be either a business model or
a service model.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 121
Which of the following are the virtual exchange modes provided by Huawei virtual switches in FusionSphere?

A. Normal Mode
B. Through Mode
C. SR-IOV Through Mode
D. VF-TRUNK

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:

QUESTION 122
It can use the physical host optical drive to install the operating system for VM in Huawei FusionSphere.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 123
Create a new disk in FusionCompute. Which of the following is incorrect?

A. Set the disk type as "normal" and set the disk mode as "standalone non-persistent"
B. Set the disk mode as "standalone non-persistent" and change the raw device mapping to "support"
C. Set the configuration mode of disk as "simplification" and set the disk mode as "standalone persistent"
D. Set the configuration mode of disk ad "simplification" and set the disk mode as "standalone non-persistent"
Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 124
In the Huawei server virtualization solution, the virtual network interface card of each virtual machine is
connected to the port of the virtual switch. To facilitate the configuration and management of multiple ports at
the same time, ports with the same network attributes are distributed to the same port group.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 125
FusionCompute can perceive the use of global physical resources during the running of a virtual machine and
use intelligent scheduling algorithms to calculate the optimal host for virtual machine operation and run the
virtual machine on the best host through hot migration and other means. This improves the overall business
experience.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 126
In FusionSphere, the type of a disk is "shared". What are the correct statements about this disk? (Multiple
Choices)

A. This disk can only be bound to one virtual machine


B. This disk can be bound to multiple virtual machines
C. The virtual machine on which this disk is mounted does not support full thermal migration
D. The virtual machine on which this disk is mounted does not support Snapshot function

Correct Answer: BC
Section: (none)
Explanation

Explanation/Reference:

QUESTION 127
In FusionCompute, you can view which port of the DVS is connected to the VM.
A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 128
What are the correct descriptions of port groups in FusionSphere? (Multiple Choices)

A. Port group is a kind of policy mechanism. These policies are used to manage the network connected to the
port group.
B. A port group is a distributed virtual switch
C. The virtual port contained in the port group has the same attributes
D. There are two types of ports in the port group, they are normal and relay.

Correct Answer: ACD


Section: (none)
Explanation

Explanation/Reference:

QUESTION 129
A snapshot in FusionSphere is a record of the data and status of a VM disk at a certain time. Which of the
following scenarios applies to the snapshot? (Multiple Choices)

A. Create a snapshot for the VM before patching the VM operating system


B. Create a snapshot of the virtual machine where the application resides before upgrading the application
C. Create a snapshot of the virtual machine before deleting the virtual machine
D. Create a snapshot of the virtual machine before shutting it down

Correct Answer: AB
Section: (none)
Explanation

Explanation/Reference:

QUESTION 130
What are the ways to deploy virtual machines on the FusionCompute?

A. Copy
B. Template conversion
C. Create directly
D. Cloning

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:
QUESTION 131
In Huawei cloud computing, which of the following technology does the VPC's network security isolation
function not rely on?

A. Hardware firewall
B. Software firewall
C. Switch
D. Elastic IP

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:

QUESTION 132
About the descriptions of the storage-related concepts in Huawei FusionSphere, which is wrong?

A. A physical storage device can be used as a storage resource


B. The storage device corresponds to a logical unit in the physical storage, such as a LUN
C. The capacity of data storage cannot be increased or decreased
D. VHD is a virtual machine disk file format

Correct Answer: C
Section: (none)
Explanation

Explanation/Reference:

QUESTION 133
Which of the following does not belong to the VM thermal migration limitations in FusionCompute?

A. Does not support the migration of mounted disks of "shared" type and the disk of linked clone virtual
machines
B. Does not support non-persistent disks and the migration of VM disks enabled iCache function
C. Does not support the thermal migration of virtual machines with a status of "faulty"
D. Does not support the thermal migration of virtual machines with a status of "running"

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:

QUESTION 134
In FusionCompute, you need to modify a disk of a VM. Which of the following operations can be implemented?

A. Change the disk configuration mode from simplification to normal


B. Change the mode of the disk from slave to standalone persistent
C. Change the capacity of the disk from 80G to 8G
D. Modify the status of the disk from available to unavailable

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 135
What is service model of cloud computing for the basic resources such as rental processing capacity, storage
space, and network capacity?

A. Infrastructure as a Service (IaaS)


B. Platform as a Service (PaaS)
C. Software as a Service (SaaS)
D. Data as a Service (DaaS)

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 136
Based on Protocol division of VLAN, as long as the network protocol of access the client is the same.

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 137
What types does VLAN port include ?

(Select 3 Answers)

A. Access
B. Trunk
C. Hybrid
D. ethernet

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:

QUESTION 138
From the view of business perspective, what kind of following things are similar to cloud computing ?

A. information power plant


B. Information gas station
C. reservoir
D. water pipe

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 139
Which statement is correct about IP addresses ?(Select 3 Answers)

A. IPv4 address is to give each host connected to the Internet assigned a 32bit address
B. IP address addressing scheme divide IP address space into A, B, C, D, E five categories, of which A, B, C
is the basic class , D, E class used as multicast and reserved
C. Network layer address consists of two parts : network address and host address , network address is
globally unique
D. a Class A IP address refers to four numbers in the IP address , the front two numbers for network number ,
and the remaining two numbers for the local computer number

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:

QUESTION 140
The second layer of the OSI reference model is the data link layer .

A. True
B. False

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 141
Which of the following technology does cloud computing include ? (Select 3 Answers)

A. memory multiplexing
B. link clone
C. Energy conservation and emissions reduction
D. automatic load balancing

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:

QUESTION 142
A company now has a set of VMware vCenter environment, ready to introduce Huawei FuionSphere solutions.

In the following FusionSphere functions' each component, which is the most suitable for the enterprise unified
management of these two environments?

A. FusionManager heterogeneous virtualization management function


B. FusionCompute server virtualization function
C. FusionManager multi-tenant function
D. FusionCompute multi-site cascade function

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 143
Which of the following age has IT infrastructure experienced ? (Select 3 Answers)

A. Distributed Computing
B. mainframe era
C. PC era
D. cloud computing era

Correct Answer: BCD


Section: (none)
Explanation

Explanation/Reference:

QUESTION 144
What are the process of layer 2 switching ? (Select 3 Answers)

A. study: the MAC address table is a switch by studying receives source MAC address of data frames to form
B. update: switch MAC address table has aging time;If you find a frame into the port and the the source MAC
port in MAC address table is not consistent, then the MAC learning to the new port
C. forward: switches according to the MAC address table radio forward data frames
D. radio: if the destination address is not in the MAC address table, in addition to receiving the data frame to
other ports outside the port to broadcast the data frame

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:

QUESTION 145
The company set up a cloud computing service platform. It provides virtual machine resource to make the
users in need to purchase and use. Which cloud compute deployment model does this company belong to?

A. Public Cloud
B. Private Cloud
C. government Cloud
D. Hybrid Cloud

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 146
When collecting the FusionSphere running logs, what are the components that do not need to be collected?

A. UHM
B. VRM
C. CNA
D. VM

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:

QUESTION 147
Which of the following description is wrong about the basic concepts of FusionManager?

A. Region is a region, such as Asia Pacific


B. DC is a data center concept, such as Beijing, Hong Kong, and Tokyo data centers
C. Zone is an independent Layer 2 network area in the data center
D. Cluster is the data center virtualization network isolation boundary

Correct Answer: D
Section: (none)
Explanation

Explanation/Reference:

QUESTION 148
In FusionCompute, administrators can move hosts. Which of the following options are the moving path?
(Multiple Choice)

A. Moving from site to cluster


B. Moving from a cluster to another cluster
C. Moving from site to site
D. Moving from a cluster to a site

Correct Answer: ABD


Section: (none)
Explanation

Explanation/Reference:

QUESTION 149
Which of the following statement is wrong about the FusionCompute maintenance mode?

A. After the host enters maintenance mode, it cannot perform operations such as power off or restart on the
host.
B. Before the host enters maintenance mode, it is recommended to shut down or remove the virtual machine
on the host before performing maintenance on the host.
C. It is not possible to create, start, or move to a virtual machine on the host in maintenance mode.
D. After the host enters maintenance mode, the VM on the host does not participate in the computing
resource scheduling policy of the cluster to which it belongs.

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 150
Which of the following is the cornerstone of Huawei FusionCloud cloud computing solution?

A. FusionAccess
B. FusionSphere
C. FusionInsight
D. FusionCube

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 151
Which way does FusionManager use to interact with FusionCompute?

A. FusionCompute Driver
B. FusionCompute SDK
C. FusionCompute API
D. FusionCompute SOAP

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 152
When a company builds IT systems, using virtualization platform to make the physical server abstractly being
combined into multiple virtual servers to use, to improve resource utilization and reduce enterprise investment
costs.
Which kind of genre does the company's use of cloud computing belong to?

A. big divided into small


B. gather small to big
C. virtualize one server to many servers
D. integrate many to one

Correct Answer: A
Section: (none)
Explanation

Explanation/Reference:

QUESTION 153
Which of the following problem is not what a traditional data processing systems face?

A. high storage costs


B. network bandwidth is insufficient
C. single data source
D. under large data volume, lack of data-processing performance

Correct Answer: B
Section: (none)
Explanation

Explanation/Reference:

QUESTION 154
What are the main functions of FusionAccess? (Multiple choice)

A. assets management, manage the relationship between user and virtual machine
B. user access, users can view and operate their own virtual machine
C. Desktop transmission, using a virtual machine through desktop link protocol
D. resource scheduling, manage and schedule cloud platform computing, storage resources

Correct Answer: ABC


Section: (none)
Explanation

Explanation/Reference:

Você também pode gostar