TECNICAL CALCULATION

BELT CONVEYOR
CONVEYOR M-7102-2B
A. DESIGN DATA
1 Conveyor Design Capacity (Qt) : 300 T/h
2 Beld Width (b) : 750 mm 29.5 in equal CEMA Standard
3 Material to be Transported : CR/Gypsum
4 Bulk Density (ρ) : 1.4 T/m3 87.30 lbs/ft3
5 Speed (v) : 140 m/minute
6 Inclination (γ) : 9.1 deg
7 Vertical Lift : 10.2 m
8 Belt Weight : 13.0 kg/m

B. CONVEYOR CAPACITY
1 Troughing Angel (β) : 30 deg
2 Surcharge Angel (α) : 5 deg CEMA Reccomendation
3 Cross Sectional Area (Asc) : 0.49 ft2 0.049 m2 Interpolasi CEMA Table 4-5
=
4 Conveyor Capacity (Qt1) : 9.604 T/minute 576.2 T/h
5 Cross check Capacity : Qt1 > Qt PASS

C. POWER CALCULATION

1 Equipment Friction Factor (Fc) : 0.0225 (for horizontal and inclined)


2 Equipment Friction Factor (Fl) : 0.025 Load calculation
3 Equipment Friction Factor (Fe) : 0.02 empty calculation
4 Horizontal Center to Center Dstance (L) : 164 m
5 Terminal friction constant (Tf) : 60 m
6 Capacity (C) : 300 T/h
7 Mass Of Moving Part (Q) : 40.8 kg/m interpolasi
8 Speed (S) : 2.333 m/s
9 Nett Change in Elevation (H) : 10.21 m
10 Drive Factor (K) : 0.38
11 Power : 17.17 Kw
12 Motor Safety Factor : 1.2
13 Taken Motor Power : 20.61 Kw
14 Power taken : 45 Kw
D TENSION
TECNICAL CALCULATION
BELT CONVEYOR
CONVEYOR M-7102-2B
1 Return Side Friction : 0.525 kN
2 Total Empty Friction : 1.793 kN
3 Carrying Side Empty Friction : 1.268 kN
4 Load Friction : 1.962 kN
5 Load Slope Tension : 3.577 kN
6 Belt Slope Tension : 1.302 kN

6 Effective Tension (Te) : 7.332 kN


7 Slack Side Tension (T2) : 2.786 kN
8 Power : 17.11 kW

9 Tight Side Tension (T1) :


10 Coefficien of frction pulley (µ) : 0.35
11 Arc of Contact Radian : 210 deg
12 Tight Side Tension (T1) : 11.97 kN

9 Maximal Operating Tension (Tmax) : 10.12 kN


10 Tsag : 3.311 kN