Você está na página 1de 1

8'-0"

Recess
Recess, see
Section B-B detail
10"
(2 places)
A
8"
1'-10"
16"
3'-8" 28"

1'-10"

C.L. of Mausoleum
NOTES
B B GENERAL
All work shall comply with the Washington State Building Code and the requirements of the local
A municipality.
All conditions and dimensions shown on plan shall be coordinated with the mausolia manufacturer
prior to start of work. Any discrepancy shall be brought to the attention of the engineer before
Locate at Foot of
Single Crypt Mausoleum Foundation Plan proceeding.
casket a center
FOUNDATIONS
opening through
Concrete footings shall be placed on undisturbed soils or compacted fill having a presumptive
slab for drainage. bearing capacity of 2 tons per square foot.

Fill with washed Granite Mausoleum


Adhere all sides to base w/ epoxy CONCRETE
gravel #1 or #2. All concrete work and materials shall comply with the building code requirements for structural
Granite base concrete (ACI318).
Adhere to concrete foundation with epoxy Cast-in-place concrete shall have a compressive strength of 4,000 PSI at age 28 days.
and S-type mortar grout Reinforcing steel shall comply with ASTM A615 Grade 60 for deformed bars.
Finished grade Reinforcing steel shall be placed to the required elevations and with the specified minimum concrete
cover. All bars shall be securely fastened to aviod displacement during concrete placement.

ADHESIVE

3 1/2"
Structural adhesive used to connect the granite slabs to the foundation and to each other shall be a
two component high-strength epoxy adhesive supplied in the manufacturer's original packaging.
Adhesive shall achieve a compressive strength of 3,500 PSI and a tensile strength of 1,000 PSI in
accordance with ANSI A118.3.5 test methods.
Adhesive shall be Simpson Epoxy Tie Structural Epoxy Adhesive from Simpson Strong-Tie
Company.
Apply adhesive uniformly over surface to be bonded covering at least 144 square inches of the
contact area.
Concrete footing
1 1/2"
TBD 4 # 4 long way @ Section A, top & bottom.
3 # 4 long way @ Section B, top & bottom.

#4 @ 12"oc short way

2" CL.

CLIENT: X PROJECT: X
X
3" clear
8" minimum compacted, crushed DRAWN BY: RS DATE: 7/20/10
stone over undisturbed soil TITLE: Mausoleum Foundation Plan & Details
CHECKED: RS DATE: 7/20/10
Section B-B Drawing No: RKT-M-003-PMI
new APPROVED
Section A-A Installation Strap Recess Detail (designed to use std. 2x4 dimensional lumber as form) REV: 1/13/09 REV: REV: SHEET: 1 OF 1 BY:

APPROVED
see Plan View PREMIER COLUMBARIA SHEET SIZE: D
DATE:
division of Premier Memorial LLC ALL DIMENSIONS TOL: XXX = ±0.1"
2309 S. TACOMA WAY, TACOMA, WA 98409 ARE IN INCHES XX.X = ±0.1"
TEL. (253) 472-0369, FAX. (253) 472-4832 SCALE: NTS X.XX = ±0.1"