Asset Damage (HIPO) Drilling Rig UPDC-180, Well # UN-0134, NK 29th December 2017; 12:10 hrs.
INCIDENT DESCRIPTION IN BRIEF
At approximately 12:10hrs, the operation was running 13 5/8’’ casing, a joint of casing number 294 measuring 46.8feet (14.2 meters)
in length and weighing 4000lbs (1814.37KG) was being picked up using the hydraulic catwalk, the single joint elevator was attached
to the casing joint. While the driller was picking up the casing joint from the power catwalk at the rig floor V door, the casing joint
snagged under the top drive beam which caused the single joint elevator wire sling shackles to part. The joint fell and landed on the
hydraulic catwalk, then rolled off and landed on the ground level on the Off Driller Side (ODS) of V-door approximately 45feet
(13.72metres) below.
There was no injury to personnel, however there was damage to the top drive beam section, casing joint, wire slings and shackles.
Misperception of risk.
Inadequate training/experience.
Tool Box Talk (TBT) and Job Safety Analysis (JSA)
was not properly followed.
Job Factors:
Inadequate leadership/supervision/planning.
Stop Work Authority was not utilized by the crew.