to the dust hopper at the bottom of the box and the dust in the hopper will be

cleaned by the ash valve. When the resistance of the filter bags reaches down threshold, the system will
close the purge-valve to stop cleaning, as so the dust remover works again. Maximum filtering rate is 1.0
to 1.5 m3/minute and the gas temperature is 50 OC to 280 OC (the system can also operate stably
(reliably) for 2 hours at gas temperature of 300 OC). The normal dust content of Mini Blast Furnace gas
after cleaning is usually not more than 3 mg/ Nm3. Service life of fabric bags is generally up to two years.
Set of bag filter with ID Fan & Stack will be provided to control the air pollution to comply with the
emission norm. The amount of dust will be sucked by hoods from different material handling facilities &
through bag filter it will be released to the atmosphere through stack. The flue gases from furnace will
be sucked through an interconnecting ductwork by induced draft fan & exhaust to the chimney. The
system will meet the emission standards during operation of the plant and ensure clean plant operation.
The fume exhaust hood with duct will be provided around the furnace circumference to capture the
fumes generated during operation. The cleaning will be off line & will take place after tapping operation
is over. Emission level at the outlet of Bag House through stack will be less than 50 mg/ Nm3.