Você está na página 1de 80

YOUR FRIENDLY EBARA BUSINESS PARTNERS & SERVICE CENTRE

HYDRO BOOSTER SYSTEM Type UN / UD / HP

Type UN

• Kuala Lumpur • Shah Alam • Butterworth / Penang • Alor Setar • Ipoh


• Kuantan • Melaka • Johor Bahru • Kuching • Kota Kinabalu

e HYDRO-P
p
Ty

Typ
eU
D

EBARA Pumps Malaysia Sdn Bhd Authorised dealer:


6, Jalan TP3, UEP Subang Jaya Industrial Park,
47620 Subang Jaya, Selangor, Malaysia.
Tel : 03-8023 8355 Fax : 03-8023 9355
Email : sales@ebara.com.my
Website : www.ebara.com.my

EPM HB 1008
EBARA HYDRO BOOSTER SYSTEM
-Total Quality Assurance
EBARA PUMPS MALAYSIA SDN BHD
- Your Reliable Quality Pump Centre
For over 55 years EBARA pumps have been sold and used widely in Malaysia;
satisfying customers and building a reputation for its quality and reliability. EBARA
PUMPS MALAYSIA SDN BHD (EPM) incorporated in January 2001 as a subsidiary
company of EBARA Corporation, Japan under the Fluid Machinery and System
Group, is responsible for sales/marketing of EBARA pumps and related equipments
in Malaysia. EPM originated with one vision in mind : to become the leading pump
company in Malaysia by providing value-added products through continuous
innovation; offering quality pumping solutions to satisfy customers’ needs and
expectations. Thus utmost efforts are focused on satisfying customers’
requirement, at all times.

To serve customers effectively, a strong and competent nationwide dealers network has been developed to
support increasing sales and service requirements of EBARA pumps. Competent engineers and technicians
are available to trouble-shoot and provide prompt after-sales service and ensure EBARA pumps are always
operating in tip-top conditions. Thus you are investing wisely into a peace-of-mind pumping solutions each
time you choose EBARA pump as EPM consider “Quality, Value, Performance” as our motto to serve, always.

Quality that shows


Customer satisfaction is of utmost importance to EBARA and EPM. Each EBARA Hydro Booster
System is 100% factory-set and factory-test to perfection before it is delivered to you. The quality
inspection and testing are carried out by competent and trained personnel to
ensure each component used in the Hydro Booster System works
effectively to meet your demands and site requirements. In addition, EBARA
Certificate of Authenticity and Warranty entitles you to the Original EBARA
field-service support that enhances operating life of EBARA Hydro Booster
System. You will be pleased to know that the EBARA nationwide Dealer
network and Service Centre throughout Malaysia further enhances our
after-sales service support by providing quick and efficient service
whenever the need arises. EBARA’s commitment is simply working
towards excellence by ensuring each EBARA Hydro Booster System unit
you receive is appropriately tested and pre-set according to ISO 9001:2000
procedures and standards accredited by Lloyd’s Register Quality Assurance.
Therefore you are investing wisely into a peace-of-mind pumping solutions
each time you choose EBARA’s pumps and systems.
EBARA HYDRO BOOSTER SYSTEM
UN

Your best choice


EBARA Variable Speed Booster System
for automatic booster pumping system

EBARA Pumps Malaysia Sdn Bhd is proud to introduce EBARA Hydro


Booster System that is built to satisfy customer’s requirement for highest
quality and operating reliability. Every EBARA Hydro Booster System is
tested with vital parameters’ factory-adjusted to meet your site
requirements. EBARA Hydro Booster System is fully warranted by EBARA
PUMPS MALAYSIA SDN BHD, a subsidiary company of EBARA
Corporation, Japan and certified by Lloyd’s Register Quality Assurance with
ISO9001:2000 certification.

OUTLINE OF EBARA HYDRO BOOSTER SYSTEM

EBARA Hydro Booster System is advance, automatic and pressurized water


supply system that is designed with 2 or more pumps installed in parallel on
common base frame, integrally built with electrical control panel that meet
the most demanding requirements for water pressure system in residential,
commercial, industrial and water supply applications. EBARA Hydro
Booster System is an automatic booster pumping system that utilize
cascade-controlled or micro-processor type of controllers to achieve system
optimization, where service water constantly supplied under pressurized
conditions in the piping system. Generally 2 types of controllers can be
applied i.e. cascade-controlled method using pressure switches and; VFD
control type that uses variable speed inverter units to achieve constant
pressure throughout the pumping system.

ADVANTAGES OF EBARA HYDRO BOOSTER SYSTEM

• Maintain pressurized pumping system


The automatic water booster system maintains sufficient water supply
pressure throughout the piping system.

• Reduce construction costs and improves space utilization


Since it is possible to reduce or eliminate the storage of water tank that are
usually installed on the roof-top of a building, construction and structural
costs can be effectively reduced. The available space on the building can
be better utilized.

• Reduce energy cost


As the booster pumping system can be sized according to its demand
patterns, operating cost of the pumpsets can be dimensioned effectively to
suit the demand patterns; thus saving the running cost of the pumping
system, especially in the case of using frequency inverters that is proven for
its energy saving capability.

• Fully automatic booster system


Just connect directly to incoming electrical supply and piping system at
required site, EBARA Hydro Booster System is capable of delivering
capacity and pressure heads instantaneously as it is already tested and
factory-set to meet designed operating parameters of your system.

• Simple installation and maintenance


EBARA Hydro Booster System is designed with simplicity in mind i.e.
package common pipe headers, integrally fitted with electrical panel and
accessories to enable easy installation and maintenance; thus ensuring
trouble-free operation at all time.

1
HYDRO BOOSTER

EBARA
Why Variable
EBARA Speed
HYDRO BoosterSYSTEM?
BOOSTER System

Nation-wide Sales & Service network


• Effective after-sales service support
Quality EBARA pump and components Certified
• Low life-cycle-cost assured Authenticit
y
EBARA proven Controller being used &
• Ensure user-friendly and peace-of-mind operation
Fully Teste
Custom-design control panel
d by

� ��
• Fully guaranteed by EBARA


��
��

��
Quality inspection & testing to ISO 9001:2000 �


�� ��
• Your assurance of trouble-free operation ��� �
��������
Warranty from single manufacturer
• Value-for-money investment

EBARA HYDRO BOOSTER SYSTEM

EBARA Available in 3 basic versions:


HYDRO UN – Variable Speed & Constant Pressure Booster System
BOOSTER UD – Flow Switch Controlled Booster System
SYSTEM Hydro-P – Hydro Pneumatic Booster System

Variable Speed Type UN


Over 12,000 Units In Operation
Since 1994
About 2,500 Units Delivered Every Year*

Flow Switch Control Type UD


Over 100,000 Units In Operation
Since 1991
About 12,000 Units Delivered Every Year*

*In Japan

2
HYDRO BOOSTER

EBARA HydroSpeed
EBARA Variable Booster System
Booster - Type UN
System (See page 4 to 31)

EBARA Variable Speed & Constant Pressure Booster System


Variable speed controlled, factory assembled automatic water supply
system with 2 to 5 pumps parallel arranged, mounted on common base
frame with common suction and discharge headers.
Using proven EBARA UN controller for compatible operation to ensure
constant pressure boosting.

Ultimate control quality, ensure constant pressure system requirement


and maintenance-free operation.

Integrated dry-running detection with automatic cut-off in the event of


low water.

Application:
Variable speed water supply booster system in residential, commercial,
public building, hotels, hospitals, schools, universities, departmental
stores, hypermarkets, golf course irrigation and industrial and process
engineering usage.

EBARA Hydro Booster System - Type UD (See page 32 to 55)

EBARA Flow Switch Controlled Booster System


Factory assembled water supply unit with 2 pumps parallel arranged,
mounted on common base frame with common suction and discharge
headers.

Using proven EBARA UD controller for automatic control of water supply


system.

Ultimate control quality, ensure simple and maintenance-free pressurised


water system.

Application:
Pressurised water supply and pressure boosting in residential, commercial
and public buildings, hotels, hospitals, schools, and departmental stores
and for light industrial usage.

EBARA Hydro Booster System - Type HP (See page 56 to 76)

EBARA Hydro Pneumatic Booster System


Factory assembled water supply unit with 2 to 5 pumps parallel arranged,
mounted on common base frame with common suction and discharge
headers.

Using EBARA designed electrical control panel for automatic control of water
supply system. In addition, JPP local approved vessel being used to enhance
optimal overall system operation.

Application:
Pressurised water supply and pressure boosting in residential, commercial and
public buildings, hotels, hospitals, schools, and departmental stores and for
light industrial usage.

3
UN

EBARA Variable Speed Booster System

UN-GB UN-IB

The EBARA Hydro Booster system consists of two or suitable for maximum hydraulic unit capacity. Check
more EVM pumps coupled in parallel and mounted on valve and suitable gate valves are fitted for optimal
a common baseplate, integrally provided with a EBARA system operation.
Hydro Controller electrical cabinet and all the necessary
common pipe work and fittings. All EBARA Hydro Diaphragm Pressure Tank
Booster system is factory assembled and tested, pre-set A pre-charged diaphragm tank is fitted to the discharge
according to customer requirement. It is ready-to-connect pipe with a compatible Butyl-rubber diaphragm. Generally
at site. Scope of supply includes instruction manual. this tank serves basic functions of supplying water at a
very low flow and minimising effect of water hammering.
Fully assembled and certified Hydro Booster set type UN
generally consist of multiple pumps arranged in parallel, Pressure Sensor
mounted on a common baseframe, pipework complete 1-5V to transmit control type signals to the EBARA Hydro
with EBARA microcomputer controller unit, frequency Booster Controller, located at the discharge side or/
inverters, pressure sensor and complete with all internal suction side (depend on systems offered).
electrical wiring.
Frequency Converter
EBARA Hydro Booster system type UN is a variable Constant water pressure is achieved due to variable speed
speed control booster system utilising advance drive made possible by the use of frequency converters.
and proven microcomputer namely EBARA Hydro To ensure highly reliable EBARA system, each pump
Controller unit to provide constant pressure to suit is equipped with frequency converter unit, thus ensure
your system requirement. optimal operation of pumping system.

Applications Flow Switch


• General water supply i.e schools, hotels, hospitals, Flow switch is used to enhance system operation by
high-rise buildings, etc. receiving signal to cut-out pump operation during low-
• Industrial water supply flow or no-flow condition. Thus can be used as dry-
• Irrigation system for garden, parks, golf courses, etc. running protection device.
• All booster pump station
Ebara Controller
Pumps This micro-processor controller unit is fitted to the Hydro
2 or more EBARA pumps are arranged for parallel Booster Control Panel to control variable speed pumping
operation. All parts contact with liquid are of stainless operation. It provides ’One-touch’ operating possibility
steel. to interpret various signals from pressure transmitter and
flow switch, thereby enhance constant pressure system
Baseframe & Common Pipe work operation. In addition, it provides various advance
Galvanized pipe work enable easy connection to all operative functions that maintain constant pressure and
commonly used pipe fittings. The pipework is sized trouble-free water supply system.

4
UN

ISOMETRIC DRAWING - Typical arrangement of EBARA UN System

4 5

3
6

8
9
10
No. Part Name
11 1 Control Panel
12
2 Controller
3 Suction Manifold
4 Gate Valve
5 Pump
6 Expansion Tank
7 Discharge Manifold
8 Pressure Switch
9 Pressure Transmitter
10 Pressure Gauge
11 Check Valve
12 Flow Switch

5
UN

EBARA Variable Speed Booster System

6
UN

EBARA Variable Speed Booster System - Features/Benefits

1. Advance energy saving system 5. Cyclic & forced cyclic operation


This unit is operating on variable speed drive control During continuous operation, if the pump continuously
incorporated with logic control system. Thus saving run over 6 hours, second pump will start to run parallel
energy for most demanding conditions. and then change over to new one. This would ensure
even operating hours for multiple pumping system; thus
2. Constant pressure water supply prolong life span of pumps.
The variable speed pumping system would ensure
constant water pressure for the furthest point with pipe
friction loss compensation capability.

Fig. Cyclic Operating System

Fig. Pipe Friction Loss Compensation Operation

3. Highly reliable inverters being used


Individual frequency inverters are provided for each
pump, thus reduces emergency risk with automatic
change over and back-up system. During pump or
inverter failure, second pump will start automatically and
back-up operation to ensure water supply continues.

Fig. Forced Cyclic Operation

6. APNC & APR System

Fig. Custom Design Control Panel

4. User-friendly operation
Ebara unique controller permits easy access and
displays most data in the front panel. The controller is
a microcomputer board with LCD operation adjustment Fig. APNC - Automatic Pump Number Charge-Over System
and instant information display.

Fig. Ebara Proven - Designed Controller Fig. APR - Automatic Pump Rest At Small Demand

7
UN

EBARA Variable Speed Booster System - Operation Method



Advance pump stop
Advance pump start

Advance pump start


Advance pump stop


5th to 2nd pump stop

5th to 2nd pump stop


3rd to 5th pump start

3rd to 5th pump start


2nd pump start

2nd pump start


When water flow is low
When water flow is great

A. When water flow is low •4 If the volume of water used decreases, the flow
•1 If water is used, the inner pressure of the pipes drop, switch is triggered and the delayed pumps shut down
triggering the pressure sensor, and advance pump in order, eventually leaving only the advance pump
(Ex: No.1) starts up. operational.
•5 If water stops being used, the flow switch is triggered, •5 If water stops being used, the flow switch is triggered,
and advance pump (Ex: No. 1) stops after the required and advance pump stops after the required time has
time has elapsed. At this time, the advance pump elapsed. At this time, the advance pump rotates. (Ex:
rotates. (Ex: The advance pump changes from No. 1 The advance pump changes from No. 1 to No. 2.)
to No. 2) •6 If water is used again, the inner pressure of the pipes
•6 If water is used again, the inner pressure of the pipes drops, triggering the pressure sensor, and 2nd pump
drops, triggering the pressure sensor, and advance (Ex: No. 2) starts up.
pump (Ex: No. 2) starts up. •7 If the flow continues to increase, the rotational speed
• If water stops being used, the flow switch is triggered,
10 of advance pump (Ex: No. 2) reaches maximum and
and advance pump (Ex: No. 2) stops after the required 2nd pump (Ex: No. 3) starts up.
time has elapsed. At this time, the advance pump •8 As the volume of water used increases in order, the
rotates. (Ex: The advance pump changes from No. 2 delayed pumps start in order from the 3rd (Ex: No.
to No. 3.) In the same way, the advance pump rotates 4) to the 4th (Ex: No. 5), to the 5th (Ex: No. 1), to a
in order from No. 3 to No. 4, No. 4 to No. 5 and No. 5 maximum of 5 pumps.
to No. 1, while steps •1 , •5 , •6 , and 10
• are repeated •9 If the volume of water used decreases, the flow
in order. switch is triggered and the delayed pumps shut down
in order, eventually leaving only the advance pump
B. When water flow is great operational.
•1 If water is used, the inner pressure of the pipes drop, • If water stops being used, the flow switch is triggered,
10
triggering the pressure sensor, and advance pump and advance pump (Ex: No. 2) stops after the required
(Ex: No.1) starts up. time has elapsed. At this time, the advance pump
•2 If the flow continues to increase, the rotational speed rotates. (Ex: The advance pump changes from No. 2
of advance pump reaches maximum and 2nd pump to No. 3.)
(Ex: No. 2) starts up. In the same way, the advance pump rotates in order
•3 As the volume of water used increases in order, the from No. 3 to No. 4, No. 4 to No. 5, and No. 5 to No.
delayed pumps starts in order from the 3rd (Ex: No. 1, while steps •1 - 10• are repeated in order.
3) to the 4th (Ex: No. 4), to the 5th (Ex: No. 5), to a
maximum of 5 pumps.

8
UN

EBARA Variable Speed Booster System - Controller

The heart of the system is the EBARA controller unit, 1 x Power on indicating light
which is user-friendly and permits ‘One-touch’ operation. 1 x Power selector switch (ALT/PAR/Rotation/P1 to P5)
It controls the sequence of pump operation with signals 1 x Mode selector switch (Auto/Test)
input from the pressure sensor and/or flow switch in 1 x Power main on off switch
Auto & Alternate mode. This user-friendly controller unit 1 x Set switch
operates compatible with other electrical components to 1 x Function / Monitor switch
ensure smooth function of booster system. 1 x Buzzer stop switch
1 x Alarm reset switch
EBARA controller unit generally provides the below ‘One- 1 x Run switch
touch’ functioning features: 1 x Stop switch
1 x LCD System parameter displays

����������������������������������� �������������������������������������������������������
������������� �������������������������������
��������� ��������

���� ����������������������������������������� �����������������������������


������ ��������������� �������������������������������
����������
����������������������������������������
���� �������������
�������������������������������
������
����������
����� ���������������������������� �����������������������������������������
���� ��������

�������������������������������������������
�������� ��������������������������������������������� ������������������������������������
������� ���������������������������������� ���������������������������������
���������

��� ���������������������������� �����������������������

������������� ���������������������������������������

���������������� �����������������������������������������

����������������������������������������
������ ������������������������ ������������������������������
���� ��������������������������������������������
���������������

����� ������������������������������ �������������������������������������


����� �������������������������������

��� ���������������� ��������������������������������������

���� ��������������� ���������������������������������������

�����������������������������
� ��������������������������������������������������������������������������

9
UN

EBARA Variable Speed Booster System - Unique Feature

Unique Feature- Receiving (Water) tank

Note 1. * Short circuit E12-E15, E22-E25 (when using the dual tank system) with the jumper cable (included).
2. Water reduction is detected by timer control. Therefore, the empty display may be triggered during the
period when the suction amount is greater than the volume of water flowing into the water tank.

PROTECTION FEATURES REMOTE MONITORING FEATURES


Automatic back up system ensure smooth The same operation conditions of the pumping system can be
and continuous pumping operation during observed and monitored at remote station with only 2 wire
the below malfunction: connection. No additional electrical supply is required. Buzzer is
- electrical leakage, provided, and distance within 500m is permissible.
- discharge pressure drop,
- inverter tripped Display Items:
1) Normal Display
Freezes pump Operation when Low Water Digital : Discharge pressure, Pump Operation Hz (each pump).
level at suction tank. Fault Display for below: Operation current (each pump), Voltage.
- suction tank water level Others : Electrical source (LED Display).
- system interlock Operation mode (Auto, Test, No. of Pump)
- electrical leakage System interlock.
- low discharge pressure. *Option (IN-LINE 2) Fault Display
BOOSTING mode) Discharge pressure drop (each pump),
Inverter fault (each pump),
Water level (over-flow, insufficient, shortage conditions).

10
Item Standard Optional
Operation system Pump speed Inverter variable speed control drive
Pressure control Constant pressure with system loss compensation
Number of pump control Single alternate, Parallel alternate, Up to 5 pumps cyclic
Pumps rest at small flow rate
Installation area Indoor Outdoor
Ambient temperature Up to 40ºC Weather-proof available
Pump Vertical multistage Pump: Model EVM 3M, CDX and other EBARA model
Power source Three phase, 380/400/415 V, 50 Hz
Pressure tank Type Pre-charged Diaphragm
Capacity 18L Over 18L
Max. working pressure 10 bar Up to 20 bar
Pressure sensor 3 Wire for DC 12V
Output Voltage 1 - 5V
Control panel Main components Inverter (each pump), Control panel (Remote type) Water level board,
& Controller Main circuit breaker, Main control CPU board Main supply noise filter
Interface board, Pilot light, Isolator, Voltage detection board Surge protector
Control circuit noise filter, Electric leakage breaker

11
Protection Electric thermal device, controlled by microcomputer
Display Items Discharge pressure {digital display}
Pump operation current {digital display}
Voltage {digital display}
Pump operation frequency {digital display}
Power {red LED}
Operation condition {running pump}
Operation mode {Automatic or manual}
Storage tank selection {Tank 1 or 2}
Storage tank water level condition {normal}
System interlock
Failure : Shortage or full of storage tank
SPECIFICATIONS FOR VARIABLE SPEED PRESSURE BOOSTER UNIT

Low discharge pressure. *Option: IN-LINE BOOSTING mode


Inverter trip
External output signal Pump running
(No voltage, normal open Pump failure
contact) Storage tank condition {Full, low, shortage}
External input signal System interlock {on/off}
(No voltage, normal open
contact)
UN
UN

Options:
Custom Built Hydro Booster System (available upon request)

Applications Product Options Features / Benefits

Inline boosting system • consistent pressure.


specially design for: • no suction tank required i.e:
• automatic water supply direct boosting from suction
system. pipe.
• water supply distribution. • flexible usage i.e. capable of
integrating with existing.
pumping system with minimal
UN-IB
modification works.

• automatic booster system • consistent pressure.


for housing estate, • reduce storage tank size.
hospitals, condominium • empties water effectively to
and high-rise building. process and utilities etc.

UN-GB

• golf course irrigation. • automatic irrigation of


required capacity and
pressure setting.
• economical design.
• economy set.

UN-GC

• general boosting for • automatic boosting system


factories, plant and for large-scale water supply.
booster station. • ensure constant pressure.
• maintenance free operation.

UN-SP

Note: Please contact EPM for any custom-built booster set.

12
UN

General Application Examples In Malaysia

13
UN

SELECTION GUIDE

2UN-EVM3
260

240

220

200
UN EVM 22F5/2.2

180

UN EVM 18F5/2.2
160
Total Head (m)

140
UN EVM 15N5/1.5

120
UN EVM 13N5/1.5

100
UN EVM 11N5/1.1

UN EVM 9N5/1.1
80

UN EVM 7N5/0.75
60
UN EVM 6N5/0.75

UN EVM 5N5/0.55
40
UN EVM 4N5/0.55
UN EVM 3N5/0.37
20
UN EVM 2N5/0.37

3
0 1.5 3 4.5 6 7.5 9 m /hr.

2UN-EVM5
260

240

220

200

UN EVM 19F5/4.0
180
UN EVM 18F5/4.0

UN EVM 16N5/3.0
160
Total Head (m)

140
UN EVM 14N5/3.0

120
UN EVM 12N5/2.2

UN EVM 11N5/2.2
100
UN EVM 10N5/2.2

80
UN EVM 8N5/1.5

UN EVM 7N5/1.5
60
UN EVM 6N5/1.1

UN EVM 5N5/1.1
40
UN EVM 4N5/0.75

UN EVM 3N5/0.55
20
UN EVM 2N5/0.37

3
0 2.5 5 7.5 10 12.5 15 m /hr.

14
UN

SELECTION GUIDE

2UN-EVM10
260

240

220

200
UN EVM 18F5/7.5

180
UN EVM 16F5/7.5

UN EVM 15F5/5.5
160
Total Head (m)

UN EVM 14N5/5.5

140
UN EVM 12N5/5.5

120
UN EVM 11N5/4.0

UN EVM 10N5/4.0
100

UN EVM 8N5/3.0
80

UN EVM 6N5/2.2
60
UN EVM 5N5/2.2

UN EVM 4N5/1.5
40
UN EVM 3N5/1.1

20 UN EVM 2N5/0.75

3
0 5 10 15 20 25 30 m /hr.

2UN-EVM18
260

240

220

200
UN EVM 12F5/11

180

UN EVM 10F5/11
160
Total Head (m)

140

UN EVM 8F5/7.5
120
UN EVM 7F5/7.5

100
UN EVM 6F5/5.5

UN EVM 5F5/5.5
80

UN EVM 4F5/4.0
60

UN EVM 3F5/3.0
40
UN EVM 2F5/2.2

20

3
0 8 16 24 32 40 48 m /hr.

15
UN

SELECTION GUIDE

2UN-EVM32
300

280

260

240

220

200
UN EVM 9-0F5/18.5

UN EVM 9-3F5/18.5
Total Head (m)

180
UN EVM 8-0F5/15
UN EVM 8-3F5/15
160
UN EVM 7-0F5/15
UN EVM 7-3F5/15
140
UN EVM 6-0F5/11

UN EVM 6-3F5/11
120
UN EVM 5-0F5/11

100
UN EVM 5-3F5/11

UN EVM 4-0F5/7.5
80
UN EVM 4-3F5/7.5

UN EVM 3-0F5/5.5
60
UN EVM 3-3F5/5.5

UN EVM 2-0F5/4.0
40
UN EVM 2-2F5/3.0

UN EVM 1-0F5/2.2
20

3
0 14 28 42 56 70 84 m /hr.

2UN-EVM45
260

240

220

UN EVM 8-2F5/30
200

UN EVM 7-0F5/30
180
UN EVM 7-2F5/30

UN EVM 6-0F5/22
160
Total Head (m)

UN EVM 6-2F5/22
140
UN EVM 5-0F5/18.5

UN EVM 5-2F5/18.5
120

UN EVM 4-0F5/15
100
UN EVM 4-2F5/15

UN EVM 3-0F5/11
80

UN EVM 3-2F5/11
60
UN EVM 2-0F5/7.5

UN EVM 2-2F5/5.5
40

UN EVM 1-0F5/4.0
20
UN EVM 1-1F5/3.0

3
0 20 40 60 80 100 120 m /hr.

16
UN

SELECTION GUIDE

2UN-EVM64
200
UN EVM 7-1F5/37
UN EVM 7-2F5/37
190
UN EVM 7-3F5/37
180
UN EVM 6-0F5/37
170
UN EVM 6-1F5/37
UN EVM 6-2F5/30
160
UN EVM 6-3F5/30
150
UN EVM 5-0F5/30
140
UN EVM 5-1F5/30
Total Head (m)

UN EVM 5-2F5/30
130
UN EVM 5-3F5/30

120
UN EVM 4-0F5/22

110
UN EVM 4-1F5/22
UN EVM 4-2F5/18.5
100
UN EVM 4-3F5/18.5

90
UN EVM 3-0F5/18.5
UN EVM 3-1F5/15
80
UN EVM 3-2F5/15
70 UN EVM 3-3F5/15

60
UN EVM 2-0F5/11
UN EVM 2-1F5/11
50
UN EVM 2-2F5/7.5
40

30
UN EVM 1-0F5/5.5
UN EVM 1-1F5/4.0
20

10

3
0 28 56 84 112 140 168 m /hr.

3UN-EVM3
260

240
UN EVM 26F5/3.0

220

UN EVM 22F5/2.2
200

180

UN EVM 18F5/2.2
160
Total Head (m)

140
UN EVM 15N5/1.5

UN EVM 13N5/1.5
120

UN EVM 11N5/1.1
100

UN EVM 9N5/1.1
80

UN EVM 7N5/0.75
60
UN EVM 6N5/0.75

UN EVM 5N5/0.55
40
UN EVM 4N5/0.55

UN EVM 3N5/0.37
20
UN EVM 2N5/0.37

3
0 7 14 m /hr.

17
UN

SELECTION GUIDE

3UN-EVM5
260

240

220

200
UN EVM 19F5/4.0

UN EVM 18F5/4.0
180

UN EVM 16N5/3.0
160
Total Head (m)

UN EVM 14N5/3.0
140

UN EVM 12N5/2.2
120
UN EVM 11N5/2.2

100 UN EVM 10N5/2.2

UN EVM 8N5/1.5
80
UN EVM 7N5/1.5

UN EVM 6N5/1.1
60
UN EVM 5N5/1.1

UN EVM 4N5/0.75
40
UN EVM 3N5/0.55

UN EVM 2N5/0.37
20

3
0 5.5 11 16.5 22 27.5 32 m /hr.

3UN-EVM10
260

240

220

UN EVM 18F5/7.5
200

UN EVM 16F5/7.5
180

UN EVM 15F5/5.5

160
UN EVM 14N5/5.5
Total Head (m)

140
UN EVM 12N5/5.5

UN EVM 11N5/4.0
120
UN EVM 10N5/4.0

100

UN EVM 8N5/3.0
80

UN EVM 6N5/2.2
60
UN EVM 5N5/2.2

UN EVM 4N5/1.5
40
UN EVM 3N5/1.1

UN EVM 2N5/0.75
20

3
0 7.5 15 22.5 30 37.5 45 m /hr.

18
UN

SELECTION GUIDE

3UN-EVM18
260

240

220

200 UN EVM 12F5/11

180

UN EVM 10F5/11
160
Total Head (m)

140

UN EVM 8F5/7.5
120
UN EVM 7F5/7.5

100
UN EVM 6F5/5.5

80 UN EVM 5F5/5.5

UN EVM 4F5/4.0
60

UN EVM 3F5/3.0
40
UN EVM 2F5/2.2

20

3
0 16 32 48 64 80 96 m /hr.

3UN-EVM32
300

280

260

240

220

UN EVM 9-0F5/18.5
200
UN EVM 9-3F5/18.5
Total Head (m)

180 UN EVM 8-0F5/15


UN EVM 8-3F5/15

160
UN EVM 7-0F5/15

UN EVM 7-3F5/15
140
UN EVM 6-0F5/11

UN EVM 6-3F5/11
120
UN EVM 5-0F5/11
UN EVM 5-3F5/11
100
UN EVM 4-0F5/7.5
UN EVM 4-3F5/7.5
80

UN EVM 3-0F5/5.5
60 UN EVM 3-3F5/5.5

UN EVM 2-0F5/4.0
40 UN EVM 2-2F5/3.0

UN EVM 1-0F5/2.2
20

3
0 21 42 63 84 105 126 m /hr.

19
UN

SELECTION GUIDE

3UN-EVM45
260

240

220

UN EVM 8-2F5/30
200

UN EVM 7-0F5/30
180
UN EVM 7-2F5/30

UN EVM 6-0F5/22
160
Total Head (m)

UN EVM 6-2F5/22

140
UN EVM 5-0F5/18.5

UN EVM 5-2F5/18.5
120

UN EVM 4-0F5/15
100
UN EVM 4-2F5/15

UN EVM 3-0F5/11
80

UN EVM 3-2F5/11
60
UN EVM 2-0F5/7.5

UN EVM 2-2F5/5.5
40

UN EVM 1-0F5/4.0
20 UN EVM 1-1F5/3.0

3
0 30 60 90 120 150 180 m /hr.

3UN-EVM64
210

200
UN EVM 7-1F5/37
UN EVM 7-2F5/37
190
UN EVM 7-3F5/37

180
UN EVM 6-0F5/37
170 UN EVM 6-1F5/37
UN EVM 6-2F5/30
160
UN EVM 6-3F5/30

150
UN EVM 5-0F5/30

140 UN EVM 5-1F5/30


Total Head (m)

UN EVM 5-2F5/30
130 UN EVM 5-3F5/30

120
UN EVM 4-0F5/22
UN EVM 4-1F5/22
110
UN EVM 4-2F5/18.5
100 UN EVM 4-3F5/18.5

90
UN EVM 3-0F5/18.5
UN EVM 3-1F5/15
80
UN EVM 3-2F5/15
UN EVM 3-3F5/15
70

60 UN EVM 2-0F5/11
UN EVM 2-1F5/11
50
UN EVM 2-2F5/7.5

40

30 UN EVM 1-0F5/5.5
UN EVM 1-1F5/4.0
20

10

3
0 42 84 126 168 210 252 m /hr.

20
UN

SELECTION GUIDE

4UN-EVM3
260

240

220

UN EVM 22F5/2.2
200

180

UN EVM 18F5/2.2
160
Total Head (m)

140 UN EVM 15N5/1.5

UN EVM 13N5/1.5
120

UN EVM 11N5/1.1
100

UN EVM 9N5/1.1
80

UN EVM 7N5/0.75
60
UN EVM 6N5/0.75

UN EVM 5N5/0.55
40
UN EVM 4N5/0.55

UN EVM 3N5/0.37
20
UN EVM 2N5/0.37

3
0 3 6 9 12 15 18 m /hr.

4UN-EVM5
260

240

220

200
UN EVM 19F5/4.0

UN EVM 18F5/4.0
180

UN EVM 16N5/3.0
160
Total Head (m)

UN EVM 14N5/3.0
140

UN EVM 12N5/2.2
120
UN EVM 11N5/2.2

100 UN EVM 10N5/2.2

UN EVM 8N5/1.5
80
UN EVM 7N5/1.5

UN EVM 6N5/1.1
60
UN EVM 5N5/1.1

UN EVM 4N5/0.75
40
UN EVM 3N5/0.55

UN EVM 2N5/0.37
20

3
0 5.5 11 16.5 22 27.5 33 m /hr.

21
UN

SELECTION GUIDE

4UN-EVM10
260

240

220

UN EVM 18F5/7.5
200

UN EVM 16F5/7.5
180
UN EVM 15F5/5.5

160 UN EVM 14N5/5.5


Total Head (m)

140
UN EVM 12N5/5.5

UN EVM 11N5/4.0
120

UN EVM 10N5/4.0
100

UN EVM 8N5/3.0
80

UN EVM 6N5/2.2
60
UN EVM 5N5/2.2

UN EVM 4N5/1.5
40
UN EVM 3N5/1.1

UN EVM 2N5/0.75
20

3
0 10 20 30 40 50 60 m /hr.

4UN-EVM18

260

240

220

200 UN EVM 12F5/11

180

UN EVM 10F5/11
160
Total Head (m)

140
UN EVM 8F5/7.5

120
UN EVM 7F5/7.5

100 UN EVM 6F5/5.5

UN EVM 5F5/5.5
80

UN EVM 4F5/4.0
60
UN EVM 3F5/3.0

40
UN EVM 2F5/2.2

20

3
0 16 32 48 64 80 96 m /hr.

22
UN

SELECTION GUIDE

4UN-EVM32
300

280

260

240

220

UN EVM 9-0F5/18.5
200
UN EVM 9-3F5/18.5

UN EVM 8-0F5/15
Total Head (m)

180
UN EVM 8-3F5/15

160 UN EVM 7-0F5/15


UN EVM 7-3F5/15

140
UN EVM 6-0F5/11
UN EVM 6-3F5/11
120
UN EVM 5-0F5/11

UN EVM 5-3F5/11
100
UN EVM 4-0F5/7.5
UN EVM 4-3F5/7.5
80
UN EVM 3-0F5/5.5
UN EVM 3-3F5/5.5
60

UN EVM 2-0F5/4.0
40 UN EVM 2-2F5/3.0

UN EVM 1-0F5/2.2
20

3
0 28 56 84 112 140 168 m /hr.

4UN-EVM45
260

240

220

UN EVM 8-2F5/30
200
UN EVM 7-0F5/30

180 UN EVM 7-2F5/30

UN EVM 6-0F5/22
160
Total Head (m)

UN EVM 6-2F5/22

140
UN EVM 5-0F5/18.5

UN EVM 5-2F5/18.5
120

UN EVM 4-0F5/15

100
UN EVM 4-2F5/15

UN EVM 3-0F5/11
80

UN EVM 3-2F5/11

60
UN EVM 2-0F5/7.5

UN EVM 2-2F5/5.5
40

UN EVM 1-0F5/4.0
UN EVM 1-1F5/3.0
20

3
0 40 80 120 160 200 240 m /hr.

23
UN

SELECTION GUIDE

4UN-EVM64
210

200
UN EVM 7-1F5/37
UN EVM 7-2F5/37
190 UN EVM 7-3F5/37

180
UN EVM 6-0F5/37
170 UN EVM 6-1F5/37

UN EVM 6-2F5/30
160 UN EVM 6-3F5/30

150
UN EVM 5-0F5/30
UN EVM 5-1F5/30
140
UN EVM 5-2F5/30
Total Head (m)

UN EVM 5-3F5/30
130

120
UN EVM 4-0F5/22
UN EVM 4-1F5/22
110
UN EVM 4-2F5/18.5
100 UN EVM 4-3F5/18.5

90 UN EVM 3-0F5/18.5
UN EVM 3-1F5/15
80
UN EVM 3-2F5/15
UN EVM 3-3F5/15
70

60 UN EVM 2-0F5/11
UN EVM 2-1F5/11
50
UN EVM 2-2F5/7.5

40

30 UN EVM 1-0F5/5.5
UN EVM 1-1F5/4.0
20

10

3
0 56 112 168 224 280 336 m /hr.

5UN-EVM3
260

240

220

UN EVM 22F5/2.2
200

180

UN EVM 18F5/2.2
160
Total Head (m)

UN EVM 15N5/1.5
140

UN EVM 13N5/1.5
120

UN EVM 11N5/1.1
100

UN EVM 9N5/1.1
80

UN EVM 7N5/0.75
60
UN EVM 6N5/0.75

UN EVM 5N5/0.55
40
UN EVM 4N5/0.55

UN EVM 3N5/0.37
20
UN EVM 2N5/0.37

3
0 4 8 12 16 20 24 m /hr.

24
UN

SELECTION GUIDE

5UN-EVM5
260

240

220

200
UN EVM 19F5/4.0

UN EVM 18F5/4.0
180

UN EVM 16N5/3.0
160
Total Head (m)

UN EVM 14N5/3.0
140

UN EVM 12N5/2.2
120
UN EVM 11N5/2.2

UN EVM 10N5/2.2
100

UN EVM 8N5/1.5
80
UN EVM 7N5/1.5

UN EVM 6N5/1.1
60
UN EVM 5N5/1.1

UN EVM 4N5/0.75
40
UN EVM 3N5/0.55

20 UN EVM 2N5/0.37

3
0 6.5 13 19.5 26 32.5 39 m /hr.

5UN-EVM10
260

240

220

UN EVM 18F5/7.5
200

UN EVM 16F5/7.5
180
UN EVM 15F5/5.5

UN EVM 14N5/5.5
160
Total Head (m)

140
UN EVM 12N5/5.5

UN EVM 11N5/4.0
120
UN EVM 10N5/4.0

100
UN EVM 8N5/3.0

80

UN EVM 6N5/2.2
60
UN EVM 5N5/2.2

UN EVM 4N5/1.5
40
UN EVM 3N5/1.1

UN EVM 2N5/0.75
20

3
0 12.5 25 37.5 50 62.5 75 m /hr.

25
UN

SELECTION GUIDE

5UN-EVM18

260

240

220

200
UN EVM 12F5/11

180

UN EVM 10F5/11
160
Total Head (m)

140
UN EVM 8F5/7.5

120
UN EVM 7F5/7.5

UN EVM 6F5/5.5
100

UN EVM 5F5/5.5
80

UN EVM 4F5/4.0
60
UN EVM 3F5/3.0

40
UN EVM 2F5/2.2

20

3
0 20 40 60 80 100 120 m /hr.

5UN-EVM32
300

280

260

240

220

UN EVM 9-0F5/18.5
200
UN EVM 9-3F5/18.5

UN EVM 8-0F5/15
Total Head (m)

180
UN EVM 8-3F5/15

UN EVM 7-0F5/15
160
UN EVM 7-3F5/15

140
UN EVM 6-0F5/11
UN EVM 6-3F5/11
120
UN EVM 5-0F5/11

UN EVM 5-3F5/11
100
UN EVM 4-0F5/7.5
UN EVM 4-3F5/7.5
80

UN EVM 3-0F5/5.5
60 UN EVM 3-3F5/5.5
UN EVM 2-0F5/4.0
40 UN EVM 2-2F5/3.0

UN EVM 1-0F5/2.2
20

3
0 35 70 105 140 175 210 m /hr.

26
UN

SELECTION GUIDE

5UN-EVM45
260

240

220

UN EVM 8-2F5/30
200
UN EVM 7-0F5/30

UN EVM 7-2F5/30
180

UN EVM 6-0F5/22
160
Total Head (m)

UN EVM 6-2F5/22

140
UN EVM 5-0F5/18.5

UN EVM 5-2F5/18.5
120
UN EVM 4-0F5/15

100 UN EVM 4-2F5/15

UN EVM 3-0F5/11
80

UN EVM 3-2F5/11
60
UN EVM 2-0F5/7.5

UN EVM 2-2F5/5.5
40

UN EVM 1-0F5/4.0
UN EVM 1-1F5/3.0
20

3
0 50 100 150 200 250 300 m /hr.

5UN-EVM64

200 UN EVM 7-1F5/37


UN EVM 7-2F5/37
UN EVM 7-3F5/37
190

180
UN EVM 6-0F5/37
UN EVM 6-1F5/37
170
UN EVM 6-2F5/30
UN EVM 6-3F5/30
160

150
UN EVM 5-0F5/30
UN EVM 5-1F5/30
140
UN EVM 5-2F5/30
Total Head (m)

UN EVM 5-3F5/30
130

120 UN EVM 4-0F5/22


UN EVM 4-1F5/22
110
UN EVM 4-2F5/18.5

100 UN EVM 4-3F5/18.5

90 UN EVM 3-0F5/18.5
UN EVM 3-1F5/15
80
UN EVM 3-2F5/15
UN EVM 3-3F5/15
70

60 UN EVM 2-0F5/11
UN EVM 2-1F5/11
50
UN EVM 2-2F5/7.5

40

30 UN EVM 1-0F5/5.5
UN EVM 1-1F5/4.0
20

10

3
0 70 140 210 280 350 420 m /hr.

27
UN

DIMENSIONAL DRAWING (2UN)

D1 W
'X`
H3

HYDRO BOOSTER

E D TP

MCCB

TANK TANK

DISCHARGE
H2

SUCTION
H1

L1 L2

SIDE VIEW VIEW 'X'

DIMENSION HI H2 H3 D1 W L1 L2 D E TANK SUCTION DISCHARGE PIPE


MODEL mm mm mm mm mm mm mm mm mm LITER MANIFOLD MANIFOLD CONNECTION
mm mm
2UN-EVM 3 75 725 800 250 600 1030 780 350 180 18 50 50 NPT

2UN-EVM 5 75 725 800 250 600 1030 780 350 180 18 50 50 NPT

2UN-EVM 10 100 725 800 250 600 1100 910 390 210 24 65 65 NPT

2UN-EVM 18 100 725 800 250 600 1245 910 440 305 24 80 80 FLANGE

2UN-EVM 32 100 725 800 250 600 1755 910 440 305 100 100 100 FLANGE

2UN-EVM 45 100 725 800 250 600 1865 1200 550 305 100 150 150 FLANGE

2UN-EVM 64 100 725 800 250 600 1865 1200 550 305 100 150 150 FLANGE

28
UN

DIMENSIONAL DRAWING (3UN)

D1 W

'X`
H3

HYDRO BOOSTER

E D D TP

MCCB

TANK TANK

DISCHARGE
H2

SUCTION
H1

L1 L2

SIDE VIEW VIEW 'X'

DIMENSION HI H2 H3 D1 W L1 L2 D E TANK SUCTION DISCHARGE PIPE


MODEL mm mm mm mm mm mm mm mm mm LITER MANIFOLD MANIFOLD CONNECTION
mm mm
3UN-EVM 3 100 625 900 250 700 1380 780 350 180 18 50 50 NPT

3UN-EVM 5 100 625 900 250 700 1380 780 350 180 18 50 50 NPT

3UN-EVM 10 100 625 900 250 700 1490 910 390 210 24 65 65 NPT

3UN-EVM 18 150 625 900 250 700 1685 910 440 305 24 100 100 FLANGE

3UN-EVM 32 150 625 900 250 700 2195 910 440 305 100 150 150 FLANGE

3UN-EVM 45 150 625 900 250 700 2415 1200 550 305 100 150 150 FLANGE

3UN-EVM 64 150 625 900 250 700 2415 1200 550 305 100 150 150 FLANGE

29
UN

DIMENSIONAL DRAWING (4UN)

D1 W

'X`

HYDRO BOOSTER
H3

E D D D TP

MCCB

TANK TANK

DISCHARGE
H2

SUCTION
H1

L1 L2

SIDE VIEW VIEW 'X'

DIMENSION HI H2 H3 D1 W L1 L2 D E TANK SUCTION DISCHARGE PIPE


MODEL mm mm mm mm mm mm mm mm mm LITER MANIFOLD MANIFOLD CONNECTION
mm mm
4UN-EVM 3 100 625 900 250 700 1730 780 350 180 18 65 65 NPT

4UN-EVM 5 100 625 900 250 700 1730 780 350 180 18 65 65 NPT

4UN-EVM 10 150 625 900 250 700 1880 910 390 210 24 80 80 FLANGE

4UN-EVM 18 150 625 900 250 700 2125 910 440 305 24 100 100 FLANGE

4UN-EVM 32 150 625 900 250 700 2635 910 440 305 100 150 150 FLANGE

4UN-EVM 45 150 625 900 250 700 2965 1200 550 305 100 200 200 FLANGE

4UN-EVM 64 150 625 900 250 700 2965 1200 550 305 100 200 200 FLANGE

30
UN

DIMENSIONAL DRAWING (5UN)

D1 W

'X`

HYDRO BOOSTER
H3

E D D D D TP

MCCB

TANK TANK

DISCHARGE
H2

SUCTION
H1

L1 L2

SIDE VIEW VIEW 'X'

DIMENSION HI H2 H3 D1 W L1 L2 D E TANK SUCTION DISCHARGE PIPE


MODEL mm mm mm mm mm mm mm mm mm LITER MANIFOLD MANIFOLD CONNECTION
mm mm
5UN-EVM 3 150 500 1100 250 800 2080 780 350 180 18 80 80 FLANGE

5UN-EVM 5 150 500 1100 250 800 2080 780 350 180 18 80 80 FLANGE

5UN-EVM 10 150 500 1100 250 800 2270 910 390 210 24 100 100 FLANGE

5UN-EVM 18 150 500 1100 250 800 2565 910 440 305 24 150 150 FLANGE

5UN-EVM 32 150 500 1100 250 800 3075 910 440 305 100 200 200 FLANGE

5UN-EVM 45 150 500 1100 250 800 3515 1200 550 305 100 200 200 FLANGE

5UN-EVM 64 150 500 1100 250 800 3515 1200 550 305 100 200 200 FLANGE

31
UD

EBARA HYDRO BOOSTER Flow Switch Control System Type UD

Ebara Hydro Booster pressure set type UD is a flow Pumps


switch control system which prevents frequent Single or two (2) EBARA pumps arranged for parallel
start/stop of pumps, thus ensure constant water operation. All parts contact with liquid are of stainless
supply. steel.

Application Diaphragm Pressure Tank


Domestic : High-rise buildings, Condominiums, A pre-charged diaphragm tank is fitted to the discharge
Apartments etc. pipe with a compatible Butyl-rubber diaphragm. Generally
Commercial : Office buildings, Hotels, Shopping this tank serves basic functions of supplying water at a
centres etc. very low flow and minimising effect of water hammering.
Industrial : High-rise factories, Manufacturing &
Processing industries applications etc. Pressure Switches
Social Service : Schools, Hospitals etc. The pressure switch controls ‘start/stop’ of pump
operation. Stop-value of pressure switch should be
Construction Features 0.6kgf/cm2 higher than pump supply pressure. Start
Fully assembled and certified Hydro Booster unit value of pressure should be set so that the water supply
consisting of one or two (2) pump arranged in parallel, appliance at the highest point of building or the most
mounted on a common baseframe, pipework complete remote place has sufficient water supply pressure.
with all hydraulically required parts, EBARA Controller
unit, pressure switches and flow switches together with Flow Switch
complete internal electrical wiring. The primary function of flow switch is to detect low flow
condition, and cut off pump operation during very low
Baseframe & Common Pipework flow condition. This reduces the frequency of on/off pump
Galvanized pipework to enable easy connection to all to prolong operating life of pumping system.
commonly used pipe fittings. The pipework is sized
suitable for maximum hydraulic unit capacity. Check
valves and suitable gate valves are fitted for optimal
system operation.

32
UD

EBARA HYDRO BOOSTER Flow Switch Control System Type UD

Hydro Booster - Flow Switch Control System

Pressure switches
Pump Adjustment type-signal cut-in and
Stainless steel casing and cut-out pumps
impeller provide rusty-free
water supply
Pre-charge diaphragm tank

Flow switch
Pressure gauge
Detects very low flow to cut
Indicator of water pressure
off No. 1 pump thus reducing
frequency of on / off pump at
low flow
Isolating Valve

Check valve
Quick closing action reduces Discharge pipe
water hammer Galvanize pipework provides
to enable easy connection

UD - Control System

Step 1) Both pumps are stopped when water tank is fully charged. In this
� condition water is supplied from the pressure tank, and water
� P3 pressure in tank gradually decreases.
P4
Supply Pressure

� �
Step 2) No. 1 pump starts at pressure P1 (Point 1 ) and water is supplied
P1
� Parallel from pump (and pressure tank).
P2 Operation
Uncontinuous �
pump operation Single
range Operation Step 3) When more water is required and water pressure decreases to P2
(Point 2 ), No. 2 pump also starts, operation point shifts to Point
Continuous pump
operation range 3 and system shifts to parallel operation.

Q1 Step 4) When water consumption decreases, water pressure in tank


Flow switch
increases and when pressure reaches P3 (Point 4 ), No. 2 pump
is stopped and operation point shifts to Point 5 .

Step 5) When water consumption further decreases, water pressure in tank


increases and pressure switch is turned off, and the flow switch
used to detect small flow, is turned off. When both pressure and
flow switches are off, No. 1 pump stops (Point 6 ). Flow switch
setting point is at small capacity point, therefore pump continuous
operation range is much wider. Accordingly pump start frequency
is greatly decreased.

33
UD

EBARA HYDRO BOOSTER Flow Switch Control System Type UD

Flow Switch
The primary function of flow switch is to detect a very Flow
low flow in order to cut off No. 1 pump. This reduces the Switch
frequency of on/off pump at low flow. The life of pump
is thus prolonged. The fundamental working principle is
shown graphically as below.

At a very low flow, the float of the flow switch positions Float
itself at/almost to its lowest resting position. That is,
water pressure force from pump discharge is equivalent/
lesser than the weight of the float. The location of the
float sends signal out to trigger No. 1 pump to stop.

At higher flow, the float is lifted up by the water pressure


force from pump discharge. Its location is determined
by the balancing act between its own weight and water
pressure force. Signal generates no impact in operation
on pump.

EBARA UD Controller Unit

The heart of the system is the EBARA controller unit, This user-friendly controller unit operates compatible with
which is user-friendly and permit ‘One-touch’ operation. other electrical components to ensure smooth functioning
It controls the sequence of pump operation with signals of booster system.
input from the pressure switch and/or flow switch in Auto
& Alternate mode. Fig. below shows the display of panel board. Two modes
of operation are possible, namely manual and auto &
EBARA controller unit generally provides the below ‘one- alternate.
touch’ functioning features:
- 1x Selector switch (P1/P2/ALT) Various configurations of standard control panel are
- 1x Selector switch (Manual/Auto/Off) available. It varies from indoor to outdoor, DOL to
- 1x Power incoming indicating light star-delta starter and auto transformer type panel.
- 2x Pump RUN indicating light
- 1x Pump overload indicating light
- 1x Alarm (fault) indicating light
- 1x Buzzer stop

34
UD

EBARA HYDRO BOOSTER Flow Switch Control System - Operation Method

Schematic Diagram Operation System Performance Curve

Both pumps not operating at N/A

very low flow & small demand.

Water supplies directly from

hydro-pneumatic pressure vessel.

At higher flow & higher demand


water pressure in
hydro-pneumatic pressure
vessel decreases to P1 (point 1 ).
No. 1 pressure switch initiates
start of No. 1 pump.

At higher flow & water pressure


decreases to P2 (point 2 ).
No. 2 pressure switch triggers
No. 2 pump to start & system
shifts to parallel operation
(operation point is at point 3 ).

As water consumption
decreases & water pressure
increases to P3 (point 4 ).
No. 2 pressure switch activates
No. 2 pump to stop & operation
shifts to point 5 .

35
UD

EBARA HYDRO BOOSTER Flow Switch Control System - Operation Method

Schematic Diagram Operation System Performance Curve

At higher flow & water pressure


decreases to P2 (point 2 ).
No. 2 pressure switch triggers
No. 2 pump to start & system
shifts to parallel operation
(operation point is at point 3 )

As water consumption
decreases & water pressure
increases to P3 (point 4 ).
No. 2 pressure switch activates
No. 2 pump to stop & operation
shifts to point 5 .

As water consumption further


decreases & water pressure
increases to P4.
No. 1 pressure switch cut off.
Flow switch triggers No. 1 pump
to stop at very low flow
of Q1 (point 6 ).

Both pumps not operating N/A


at no demand.

36
UD

EBARA HYDRO BOOSTER Flow Switch Control System - Operation Method

Schematic Diagram Operation System Performance Curve

As demand increases again &


water pressure in
hydropneumatic pressure
vessel decreases to P1 (point
1 ) No. 1 pressure switch
initiates start of No.2 pump.

At higher flow & water pressure


decreases to P2 (point 2 ).
No. 2 pressure switch triggers
No. 1 pump to start & system
shifts to parallel operation
(operation point is at point 3 ).

As water consumption
decreases & water pressure
increases to P3 (point 4 ).
No. 2 pressure switch activates
No. 1 pump to stop & operation
shifts to point 5 .

As water consumption further


decreases & water pressure
increases to P4.
No. 1 pressure switch cut off.
Flow switch triggers No. 2 pump
to stop at very low flow
of Q1 (point 6 ).

Both pumps not operating N/A


at no demand.

37
UD

ISOMETRIC DRAWING - Typical arrangement of EBARA UD system

� �




��
��

38
UD

SELECTION GUIDE

UD CDX 70 / 90
CURVES 2 POLES 50 Hz
70

60

50

40

UD CDX 90-10/0.75
30
UD CDX 70-07/0.55

20
UD CDX 70-05/0.37

10

0
3
0 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 13.2 14.4 m /hr

UD CDX 120
CURVES 2 POLES 50 Hz
60

50

40
UD CDX 120-20/1.5

UD CDX 120-12/0.9
30

UD CDX 120-07/0.55
20

10

0
3
0 3 6 9 12 15 18 21 24 27 30 m /hr

39
UD

SELECTION GUIDE

UD CDX 200
CURVES 2 POLES 50 Hz
70

60

50

40
UD CDX 200-25/1.8

UD CDX 200-20/1.5
30

20
UD CDX 200-12/0.9

10

0
0 3 6 9 12 15 18 21 24 27 30 33
3
36 m /hr

UD 2CDX 70
CURVES 2 POLES 50 Hz
70

UD 2CDX 70-20/1.5
60

UD 2CDX 70-15/1.1

50
UD 2CDX 70-12/0.9

40
UD 2CDX 70-10/0.75

30

20

10

0
3
0 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 13.2 14.4 m /hr

40
UD

SELECTION GUIDE

UD 2CDX 120
CURVES 2 POLES 50 Hz
80

70
UD 2CDX 120-40/3.0

UD 2CDX 120-30/2.2
60

UD 2CDX 120-20/1.5
50

40
UD 2CDX 120-15/1.1

30

20

10

0
0 3 6 9 12 15 18 21 24 27 30 33 36 m /hr
3

UD 2CDX 200
CURVES 2 POLES 50 Hz
80

m
UD 2CDX 200-50/3.7

70

UD 2CDX 200-40/3.0
60

UD 2CDX 200-30/2.2
50

40

30

20

10

0
3
0 3 6 9 12 15 18 21 24 27 30 33 36 m /hr

41
UD

SELECTION GUIDE

UD 3M 32
CURVES 2 POLES 50 Hz
100

90

80

70 UD 3M 32-200/5.5

60

UD 3M 32-200/4.0 UD 3M 32-200/7.5
50

UD 3M 32-200/3.0
40

UD 3M 32-160/2.2

30
UD 3M 32-160/1.5

UD 3M 32-125/1.1
20

10

0 3
0 3 6 9 12 15 18 21 24 27 30 33 36 39 42 54 m /hr

UD 3M 40
CURVES 2 POLES 50 Hz
100

90

80

UD 3M 40-200/11
70

60
UD 3M 40-200/7.5

50

UD 3M 40-200/5.5

40
UD 3M 40-160/4.0

30 UD 3M 40-160/3.0
UD 3M 40-125/2.2

20
UD 3M 40-125/1.5

10

0
3
0 6 12 18 24 30 36 42 48 54 60 66 72 78 84 90 m /hr

42
UD

SELECTION GUIDE

UD 3M 50
CURVES 2 POLES 50 Hz
80

UD 3M 50-200/15
70

60
UD 3M 50-200/11

UD 3M 50-200/9.2
50

40
UD 3M 50-160/7.5

UD 3M 50-160/5.5
30

UD 3M 50-125/4.0
UD 3M 50-125/3.0
20
UD 3M 50-125/2.2

10

0 3
0 12 24 36 48 60 72 84 96 108 120 132 144 156 m /hr

UD 3M 65
CURVES 2 POLES 50 Hz
70

m UD 3M 65-200/22

60
UD 3M 65-200/18.5

UD 3M 65-200/15
50

UD 3M 65-160/15

40 UD 3M 65-160/11

UD 3M 65-160/9.2
UD 3M 65-160/7.5
30 UD 3M 65-125/7.5
UD 3M 65-125/5.5

20 UD 3M 65-125/4.0

10

0 3
0 30 60 90 120 150 180 210 240 270 300 330 m /hr

43
UD

SELECTION GUIDE

UD MATRIX 3
CURVES 2 POLES 50 Hz
110
m

100
UD MATRIX 3-9/1.5

90
UD MATRIX 3-8/1.3

80
UD MATRIX 3-7/1.3

70

UD MATRIX 3-6/0.9

60

UD MATRIX 3-5/0.75
50

UD MATRIX 3-4/0.65
40

UD MATRIX 3-3/0.65
30

UD MATRIX 3-2/0.45
20

10

0 3
0 0.6 1.2 1.8 2.4 3 3.6 4.2 4.8 5.4 6 6.6 7.2 7.8 8.4 9 9.6 m /hr

UD MATRIX 5
CURVES 2 POLES 50 Hz
110
m

100 UD MATRIX 5-9/2.2

90
UD MATRIX 5-8/2.2

80
UD MATRIX 5-7/1.5

70

UD MATRIX 5-6/1.3

60

UD MATRIX 5-5/1.3
50

UD MATRIX 5-4/0.9
40

UD MATRIX 5-3/0.65
30

UD MATRIX 5-2/0.45
20

10

0
3
0 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 13.2 14.4 15.6 16.8 18 19.2 m /hr

44
UD

SELECTION GUIDE

UD MATRIX 10
CURVES 2 POLES 50 Hz
80

70
UD MATRIX 10-6/2.2

60
UD MATRIX 10-5/2.2

50

UD MATRIX 10-4/1.5

40

UD MATRIX 10-3/1.3

30

UD MATRIX 10-2/0.75
20

10

0
3
0 3 6 9 12 15 18 21 24 27 30 33 36 m /hr

UD MATRIX 18
CURVES 2 POLES 50 Hz
80

70
UD MATRIX 18-6/4.0

60
UD MATRIX 18-5/4.0

50

UD MATRIX 18-4/3.0

40

UD MATRIX 18-3/2.2

30

UD MATRIX 18-2/1.5
20

10

0
3
0 6 12 18 24 30 36 42 48 54 60 66 m /hr

45
UD

SELECTION GUIDE

UD-EVM3
160

140

120

100
UD EVM 11N5/1.1
Total Head (m)

UD EVM 9N5/1.1
80

UD EVM 7N5/0.75
60
UD EVM 6N5/0.75

UD EVM 5N5/0.55
40
UD EVM 4N5/0.55
UD EVM 3N5/0.37
20
UD EVM 2N5/0.37

0
3
0 1.5 3 4.5 6 7.5 9 m /hr.

UD-EVM5
160

140

120

100
UD EVM 10N5/2.2
Total Head (m)

80
UD EVM 8N5/1.5

UD EVM 7N5/1.5
60
UD EVM 6N5/1.1

UD EVM 5N5/1.1
40
UD EVM 4N5/0.75

UD EVM 3N5/0.55
20
UD EVM 2N5/0.37

0
3
0 2.5 5 7.5 10 2.5 15 m /hr.

46
UD

SELECTION GUIDE

UD-EVM10
160

140

120

UD EVM 10N5/4.0
100
Total Head (m)

UD EVM 8N5/3.0
80

UD EVM 6N5/2.2
60
UD EVM 5N5/2.2

UD EVM 4N5/1.5
40
UD EVM 3N5/1.1

20 UD EVM 2N5/0.75

0
3
0 5 10 15 20 25 30 m /hr.

UD-EVM18
160

140

120
UD EVM 7F5/7.5

100
UD EVM 6F5/5.5
Total Head (m)

UD EVM 5F5/5.5
80

UD EVM 4F5/4.0
60

UD EVM 3F5/3.0
40
UD EVM 2F5/2.2

20

0
3
0 8 16 24 32 40 48 m /hr.

47
UD

SELECTION GUIDE

UD-EVM32
160

140

120
UD EVM 5-0F5/11

100
UD EVM 5-3F5/11
Total Head (m)

UD EVM 4-0F5/7.5
80
UD EVM 4-3F5/7.5

UD EVM 3-0F5/5.5
60
UD EVM 3-3F5/5.5

UD EVM 2-0F5/4.0
40
UD EVM 2-2F5/3.0

UD EVM 1-0F5/2.2
20

0
3
0 14 28 42 46 70 84 m /hr.

UD-EVM45
160

140
UD EVM 5-0F5/18.5

UD EVM 5-2F5/18.5
120

UD EVM 4-0F5/15
100
Total Head (m)

UD EVM 4-2F5/15

UD EVM 3-0F5/11
80

UD EVM 3-2F5/11
60
UD EVM 2-0F5/7.5

UD EVM 2-2F5/5.5
40

UD EVM 1-0F5/4.0
20
UD EVM 1-1F5/3.0

0
3
0 20 40 60 80 100 120 m /hr.

48
UD

SELECTION GUIDE

UD-EVM64
120

110
UD EVM 4-1F5/22
UD EVM 4-2F5/18.5
100
UD EVM 4-3F5/18.5

90
UD EVM 3-0F5/18.5
UD EVM 3-1F5/15
Total Head (m)

80
UD EVM 3-2F5/15
70 UD EVM 3-3F5/15

60
UD EVM 2-0F5/11
UD EVM 2-1F5/11
50
UD EVM 2-2F5/7.5
40

30
UD EVM 1-0F5/5.5
UD EVM 1-1F5/4.0
20

10

0
3
0 28 56 84 112 140 168 m /hr.

49
UD

DIMENSIONAL DRAWING UD SYSTEM (CDX)

D W

`X'
No. 1 PUMP No. 2 PUMP
RUN RUN

MAN OFF AUTO


OVERLOAD ALARM

BZ
STOP No. 1 ALT No. 2

HYDRO BOOSTER

H
TANK TANK

50 NPT
50 NPT DISCHARGE
DISCHARGE

50 NPT
50 NPT SUCTION
SUCTION

75
F L3 E
L2
L1
VIEW X
CDX PUMP

DIMENSION D W H L1 L2 L3 E F TANK PIPE


MODEL mm mm mm mm mm mm mm mm LITER CONNECTION

UD-2 x CDX 200 450 1525 1030 860 350 250 180 18 NPT

DIMENSIONAL DRAWING UD SYSTEM (MATRIX)

D W

`X'
No. 2 PUMP
No. 1 PUMP
RUN RUN

MAN OFF AUTO


OVERLOADALARM

BZ
STOP No. 1 ALT No. 2

HYDRO BOOSTER
H

TANK TANK

DISCHARGE
DISCHARGE

SUCTION
SUCTION
100

F L3 E
L2
L1
VIEW X
MATRIX PUMP

DIMENSION D W H L1 L2 L3 E F TANK PIPE


MODEL mm mm mm mm mm mm mm mm LITER CONNECTION

UD-2 x MATRIX 3/5/10 200 450 1525 1030 860 350 250 180 18 50 NPT

UD-2 x MATRIX 18 200 450 1525 1080 910 350 250 180 24 75 NPT

50
UD

DIMENSIONAL DRAWING UD SYSTEM (3M 32)

D W

`X' No. 1 PUMP No. 2 PUMP


RUN RUN

MAN OFF AUTO


OVERLOAD ALARM

BZ
STOP No. 1 ALT No. 2

HYDRO BOOSTER
H

TANK
TANK

DN 50
DISCHARGE

SUCTION
DN 65
75

F L3 E
L1 L2

3M PUMP VIEW X

DIMENSION D W H L1 L2 L3 E F TANK PIPE


MODEL mm mm mm mm mm mm mm mm LITER CONNECTION

UD-2 x 3M32 200 550 1525 1200 920 440 250 210 24 FLANGE

51
UD

DIMENSIONAL DRAWING UD SYSTEM (3M 40)

D W

`X' No. 1 PUMP No. 2 PUMP


RUN RUN

OVERLOAD ALARM
MAN OFF AUTO

BZ
STOP No. 1 ALT No. 2

HYDRO BOOSTER
H

TANK
TANK

DN 50
DISCHARGE

SUCTION
DN 80
100

F L3 E
L1 L2

3M PUMP VIEW X

DIMENSION D W H L1 L2 L3 E F TANK PIPE


MODEL mm mm mm mm mm mm mm mm LITER CONNECTION

UD-2 x 3M40 200 550 1525 1460 1050 500 310 250 24 FLANGE

52
UD

DIMENSIONAL DRAWING UD SYSTEM (3M 50)

D W

`X' No. 1 PUMP No. 2 PUMP


RUN RUN

MAN OFF AUTO


OVERLOAD ALARM

BZ
STOP No. 1 ALT No. 2

HYDRO BOOSTER
H

TANK
TANK

DN 65
DISCHARGE

SUCTION
DN 80
100

F L3 E
L2
L1

VIEW X
3M PUMP

DIMENSION D W H L1 L2 L3 E F TANK PIPE


MODEL mm mm mm mm mm mm mm mm LITER CONNECTION

UD-2 x 3M50 200 550 1525 1460 1050 500 310 250 24 FLANGE

53
UD

DIMENSIONAL DRAWING UD SYSTEM (3M 65)

D W

`X' No. 1 PUMP No. 2 PUMP


RUN RUN

MAN OFF AUTO


OVERLOAD ALARM

BZ
STOP No. 1 ALT No. 2

HYDRO BOOSTER
H

TANK
TANK

DISCHARGE
DN 80

SUCTION
DN 100
100

F L3 E
L1 L2

3M PUMP VIEW X

DIMENSION D W H L1 L2 L3 E F TANK PIPE


MODEL mm mm mm mm mm mm mm mm LITER CONNECTION

UD-2 x 3M65 200 550 1525 1460 1050 500 310 250 24 FLANGE

54
UD

DIMENSIONAL DRAWING UD SYSTEM (EVM)

`X'
No.1 PUMP No.2 PUMP
RUN RUN
MAN OFF AUTO
OVERLOAD ALARM

BZ
No.1 ALT No.2
STOP

HYDRO BOOSTER

TANK

H TANK

DISCHARGE
B3

SUCTION
100

B1 B2
L1
L2

VIEW `X' EVM PUMP

DIMENSION B1 B2 B3 H L1 L2 TANK SUCTION DISCHARGE PIPE


mm mm mm mm mm mm LITER MANIFOLD MANIFOLD CONNECTION
MODEL
mm mm
2UD-EVM 3 400 700 350 1525 1030 880 18 50 50 NPT

2UD-EVM 5 400 700 350 1525 1030 880 18 50 50 NPT

2UD-EVM 10 420 720 350 1525 1100 1040 24 65 65 NPT

2UD-EVM 18 420 720 350 1525 1245 1040 24 80 80 FLANGE

2UD-EVM 32 440 740 400 1525 1755 1360 100 100 100 FLANGE

2UD-EVM 45 440 740 400 1525 1860 1530 100 150 150 FLANGE

2UD-EVM 64 440 740 400 1525 1860 1530 100 150 150 FLANGE

55
HP

EBARA HYDRO-PNEUMATIC BOOSTER SYSTEM

EBARA Hydro-pneumatic booster system uses Custom designed electrical control panel is utilised
EBARA stainless steel pumps with one or more and built to highest standard, interconnected
pressure tanks mounted on a common baseplate with pump motor and control devices to ensure
skid consisting of valves and manifolds. automatic trouble-free booster operation.

PUMPS CONTROL PANEL


Vertical multi-stage stainless steel pump, all wetted Corrosion-resistance epoxy coated control panel
parts in contact with liquid are stainless steel for robust incorporated with quality electrical / electronic
operation. components built to EBARA’s quality standard.
Option: Other EBARA centrifugal pumps also avalable upon request.
ACCESSORIES
Approved pressure switches, valves and fittings are
TANK selected and used to enhance operating efficiency and
Local JKKP approved tanks with imported supreme assure durability.
quality diaphragm to ensur e long operating life.

Options:

EBARA HP booster set with EVM pump Weather-proof type HP booster set

56
HP

SELECTION GUIDE

������������������ ������������������
������������� �������������
��������� ����� �������� �� �� �� �� ��� ��� ��� ��� ��� ��� ��� ��� ��������� ����� �������� ��� ��� ��� ��� ��� ��� ���� ���� ����
������������� ����� ������ ��� ��� ��� ��� ��� ��� ��� �� �� �� �� �� ��������� ����� ������ �� �� �� �� �� �� �� �� ��
����������������������������������� �����������������������������������
EVM 3 2N5/0.37 0,37 18,6 16,7 14,0 10,3 6,6 - - - - - - - - EVM 32 1-0F5/2.2 2,2 22,6 20,2 17,5 13,9 10,3 5,7 - - - -
EVM 3 3N5/0.37 0,37 27,9 25,1 20,9 15,5 9,9 - - - - - - - - EVM 32 2-2F5/3.0 3 39,0 34,6 29,7 21,2 14,2 - - - - -
EVM 3 4N5/0.55 0,55 37,2 33,4 27,9 20,6 13,2 - - - - - - - - EVM 32 2-0F5/4.0 4 45,0 40,5 36,0 29,5 23,2 14,9 - - - -
EVM 3 5N5/0.55 0,55 46,5 42,0 34,9 25,8 16,5 - - - - - - - - EVM 32 3-3F5/5.5 5,5 55,0 52,0 45,0 32,8 22,7 - - - - -
EVM 3 6N5/0.75 0,75 56,0 50,0 42,0 30,9 19,8 - - - - - - - - EVM 32 3-0F5/5.5 5,5 68,0 61,0 54,5 45,0 36,1 24,1 - - - -
EVM 3 7N5/0.75 0,75 65,0 58,5 49,0 36,1 23,1 - - - - - - - - EVM 32 4-3F5/7.5 7,5 81,0 72,5 63,5 48,5 35,6 - - - - -
EVM 3 9N5/1.1 1,1 84,0 75,0 63,0 46,5 29,7 - - - - - - - - EVM 32 4-0F5/7.5 7,5 90,5 81,5 73,0 61,0 49,0 33,3 - - - -
EVM 3 11N5/1.1 1,1 - 92,7 77,0 56,5 36,3 - - - - - - - - EVM 32 5-3F5/11 11 - 93,0 82,0 64,0 48,5 30,5 - - - -
EVM 3 13N5/1.5 1,5 - - 90,5 67,0 43,0 - - - - - - - - EVM 32 5-0F5/11 11 - - 91,5 76,5 62,0 42,5 - - - -
EVM 3 15N5/1.5 1,5 - - - 77,5 49,5 - - - - - - - - EVM 32 6-3F5/11 11 - - 100,0 79,5 61,5 39,7 - - - -
EVM 3 18F5/2.2 2,2 - - - 92,5 59,5 - - - - - - - - EVM 32 6-0F5/11 11 - - - 92,0 75,0 51,5 - - - -
EVM 3 22F5/2.2 2,2 - - - - 72,5 - - - - - - - - EVM 32 7-3F5/15 15 - - - 95,5 74,5 49,0 - - - -
EVM 3 26F5/3.0 3 - - - - 86,0 - - - - - - - - EVM 32 7-0F5/15 15 - - - 108,0 87,5 61,0 - - - -
EVM 5 2N5/0.37 0,37 20,2 - 18,4 16,9 15,4 12,2 6,9 - - - - - - EVM 32 8-3F5/15 15 - - - - 87,0 58,0 - - - -
EVM 5 3N5/0.55 0,55 30,2 - 27,6 25,3 23,1 18,4 10,3 - - - - - - EVM 32 8-0F5/15 15 - - - - 101,0 70,0 - - - -
EVM 5 4N5/0.75 0,75 40,5 - 36,8 33,8 30,8 24,5 13,8 - - - - - - EVM 32 9-3F5/18.5 18,5 - - - - 100,0 67,5 - - - -
EVM 5 5N5/1.1 1,1 50,5 - 46,0 42,0 38,6 30,6 17,2 - - - - - - EVM 32 9-0F5/18.5 18,5 - - - - - 79,5 - - - -
EVM 5 6N5/1.1 1,1 60,5 - 55,0 50,5 46,5 36,7 20,6 - - - - - - EVM 32 10-3F5/18.5 18,5 - - - - - 76,5 - - - -
EVM 5 7N5/1.5 1,5 70,5 - 64,5 59,0 54,0 43,0 24,1 - - - - - - EVM 32 10-1F5/18.5 18,5 - - - - - 84,5 - - - -
EVM 5 8N5/1.5 1,5 80,5 - 73,5 67,5 61,5 49,0 27,5 - - - - - - EVM 45 1-1F5/3.0 3 21,0 - 18,9 17,6 16,3 14,3 8,3 - - -
EVM 5 10N5/2.2 2,2 - - 93,5 86,0 79,0 63,0 36,6 - - - - - - EVM 45 1-0F5/4.0 4 27,0 - 25,6 24,6 23,5 21,8 16,7 13,3 - -
EVM 5 11N5/2.2 2,2 - - - 94,5 86,5 69,5 40,5 - - - - - - EVM 45 2-2F5/5.5 5,5 42,0 - 38,1 35,8 33,4 29,8 18,6 - - -
EVM 5 12N5/2.2 2,2 - - - - 94,5 75,5 44,0 - - - - - - EVM 45 2-0F5/7.5 7,5 54,0 - 51,5 50,0 48,0 45,0 35,4 29,1 - -
EVM 5 14N5/3.0 3 - - - - - 88,0 51,0 - - - - - - EVM 45 3-2F5/11 11 69,0 - 64,0 61,0 58,0 53,0 37,3 - - -
EVM 5 16N5/3.0 3 - - - - - - 58,5 - - - - - - EVM 45 3-0F5/11 11 81,0 - 77,5 75,0 72,5 68,0 54,0 45,0 - -
EVM 5 18F5/4.0 4 - - - - - - 66,0 - - - - - - EVM 45 4-2F5/15 15 96,0 - 90,0 86,0 82,0 76,0 56,0 43,0 - -
EVM 5 19F5/4.0 4 - - - - - - 69,5 - - - - - - EVM 45 4-0F5/15 15 - - 103,0 100,0 96,5 91,0 73,0 60,5 - -
EVM 5 22F5/4.0 4 225,0 - 206,0 189,0 173,0 139,0 80,5 - - - - - - EVM 45 5-2F5/18.5 18,5 - - - - 107,0 99,0 74,5 58,5 - -
EVM 5 24F5/5.5 5,5 - - - - - - 88,0 - - - - - - EVM 45 5-0F5/18.5 18,5 - - - - - 114,0 91,5 76,5 - -
EVM 10 2N5/0.75 0,75 22,0 - - - 21,0 20,4 18,9 17,6 13,2 7,8 - - - EVM 45 6-2F5/22 22 - - - - - - 93,5 74,5 - -
EVM 10 3N5/1.1 1,1 33,0 - - - 31,6 30,5 28,4 26,4 19,8 11,7 - - - EVM 45 6-0F5/22 22 - - - - - - 110,0 92,5 - -
EVM 10 4N5/1.5 1,5 44,0 - - - 42,0 40,5 37,8 35,2 26,4 15,6 - - - EVM 45 7-2F5/30 30 - - - - - - 112,0 90,5 - -
EVM 10 5N5/2.2 2,2 55,0 - - - 52,5 51,0 47,5 44,0 33,0 19,5 - - - EVM 45 7-0F5/30 30 - - - - - - - 108,0 - -
EVM 10 6N5/2.2 2,2 66,0 - - - 63,0 61,0 57,0 53,0 39,5 23,4 - - - EVM 45 8-2F5/30 30 - - - - - - - 106,0 - -
EVM 10 8N5/3.0 3 88,0 - - - 84,0 81,5 75,5 70,5 52,5 31,2 - - - EVM 45 8-0F5/30 30 - - - - - - - 124,0 - -
EVM 10 10N5/4.0 4 - - - - - - 94,5 88,0 66,0 39,0 - - - EVM 45 9-2F5/30 30 - - - - - - - 122,0 - -
EVM 10 11N5/4.0 4 - - - - - - - 97,0 72,5 43,0 - - - EVM 64 1-1F5/4.0 4 23,7 - - 21,0 20,4 19,7 17,5 15,9 11,4 -
EVM 10 12N5/5.5 5,5 - - - - - - - - 86,5 55,0 - - - EVM 64 1-0F5/5.5 5,5 29,3 - - 26,6 26,1 25,4 23,7 22,3 18,5 13,5
EVM 10 14N5/5.5 5,5 - - - - - - - - - 64,5 - - - EVM 64 2-2F5/7.5 7,5 47,5 - - 42,5 41,5 40,5 36,5 33,5 25,3 -
EVM 10 15F5/5.5 5,5 - - - - - - - - - 69,0 - - - EVM 64 2-1F5/11 11 53,0 - - 48,0 47,0 46,0 42,5 40,0 32,4 23,0
EVM 10 16F5/7.5 7,5 - - - - - - - - - 73,5 - - - EVM 64 2-0F5/11 11 58,5 - - 53,5 53,0 52,0 49,0 46,5 39,5 30,6
EVM 10 18F5/7.5 7,5 - - - - - - - - - 83,0 - - - EVM 64 3-3F5/15 15 71,0 - - 64,0 62,5 61,0 55,5 51,0 39,3 -
EVM 10 20F5/7.5 7,5 - - - - - - - - - 92,0 - - - EVM 64 3-2F5/15 15 76,5 - - 69,5 68,0 66,5 61,5 57,5 46,5 32,5
EVM 18 2F5/2.2 2,2 32,0 - - - - - 31,0 30,3 28,5 25,7 21,9 17,2 11,6 EVM 64 3-1F5/15 15 82,5 - - 75,0 74,0 72,5 68,0 64,0 53,5 40,0
EVM 18 3F5/3.0 3 48,0 - - - - - 46,0 45,5 43,0 38,6 32,8 25,7 17,4 EVM 64 3-0F5/18.5 18,5 88,0 - - 80,5 79,5 78,0 74,0 70,5 60,5 47,5
EVM 18 4F5/4.0 4 64,0 - - - - - 61,5 60,5 57,0 51,5 44,0 34,3 23,2 EVM 64 4-3F5/18.5 18,5 - - - 91,0 89,0 87,0 80,5 75,5 60,5 42,0
EVM 18 5F5/5.5 5,5 80,0 - - - - - 77,0 75,5 71,5 64,5 54,5 43,0 29,0 EVM 64 4-2F5/18.5 18,5 - - - 96,5 95,0 93,0 87,0 81,5 67,5 49,5
EVM 18 6F5/5.5 5,5 96,0 - - - - - 92,0 91,0 85,5 77,0 65,5 51,5 34,8 EVM 64 4-1F5/22 22 - - - - 101,0 98,5 93,0 88,0 74,5 57,0
EVM 18 7F5/7.5 7,5 - - - - - - - - 100,0 90,0 76,5 60,0 40,5 EVM 64 4-0F5/22 22 - - - - - - 99,0 94,5 81,5 64,5
EVM 18 8F5/7.5 7,5 - - - - - - - - - - 87,5 68,5 46,5 EVM 64 5-3F5/30 30 - - - - - - 106,0 99,5 81,5 59,0
EVM 18 10F5/11 11 - - - - - - - - - - - 93,5 69,0 EVM 64 5-2F5/30 30 - - - - - - - 106,0 88,5 66,5
EVM 18 12F5/11 11 - - - - - - - - - - - - 83,0 EVM 64 5-1F5/30 30 - - - - - - - - 95,5 74,0
EVM 18 14F5/15 15 - - - - - - - - - - - - 96,5 EVM 64 5-0F5/30 30 - - - - - - - - 103,0 81,5
EVM 18 15F5/15 15 - - - - - - - - - - - - 104,0 EVM 64 6-3F5/30 30 - - - - - - - - 103,0 76,0
EVM 18 16F5/15 15 - - - - - - - - - - - - 110,0 EVM 64 6-2F5/30 30 - - - - - - - - 110,0 83,5
EVM 64 6-1F5/37 37 - - - - - - - - 117,0 91,0
EVM 64 6-0F5/37 37 - - - - - - - - - 99,0
EVM 64 7-3F5/37 37 - - - - - - - - - 93,0
EVM 64 7-2F5/37 37 - - - - - - - - - 101,0
EVM 64 7-1F5/37 37 - - - - - - - - - 108,0

Note : Performance table shown based on one (1) pump operating capacity, if two (2) pumps system operation, please multi capacity x 2.

57
HP

ISOMETRIC DRAWING - Typical arrangement of EBARA HP System

4
3
2
1

8 No. Part Name


1 Control Panel
2 Pump
3 Suction Manifold
4 Gate Valve
9 5 JKKP Approved Tank
6 Pressure Gauge
7 Pressure Switch
8 Discharge Manifold
9 Check Valve

58
HP

SELECTION GUIDE

2HP-EVM3
260

240

HP EVM 26F5/3.0
220

200
HP EVM 22F5/2.2

180

HP EVM 18F5/2.2
160
Total Head (m)

140
HP EVM 15N5/1.5

120
HP EVM 13N5/1.5

100
HP EVM 11N5/1.1

HP EVM 9N5/1.1
80

HP EVM 7N5/0.75
60
HP EVM 6N5/0.75

HP EVM 5N5/0.55
40
HP EVM 4N5/0.55
HP EVM 3N5/0.37
20
HP EVM 2N5/0.37

3
0 1.5 3 4.5 6 7.5 9 m /hr.

2HP-EVM5
260

240
HP EVM 24F5/5.5

220
HP EVM 22F5/4.0

200

HP EVM 19F5/4.0
180
HP EVM 18F5/4.0

HP EVM 16N5/3.0
160
Total Head (m)

140
HP EVM 14N5/3.0

120
HP EVM 12N5/2.2

HP EVM 11N5/2.2
100
HP EVM 10N5/2.2

80
HP EVM 8N5/1.5

HP EVM 7N5/1.5
60
HP EVM 6N5/1.1

HP EVM 5N5/1.1
40
HP EVM 4N5/0.75

HP EVM 3N5/0.55
20
HP EVM 2N5/0.37

3
0 2.5 5 7.5 10 12.5 15 m /hr.

59
HP

SELECTION GUIDE

2HP-EVM10
260

HP EVM 22F5/11
240

220
HP EVM 20F5/7.5

200
HP EVM 18F5/7.5

180
HP EVM 16F5/7.5

HP EVM 15F5/5.5
160
Total Head (m)

HP EVM 14N5/5.5

140
HP EVM 12N5/5.5

120
HP EVM 11N5/4.0

HP EVM 10N5/4.0
100

HP EVM 8N5/3.0
80

HP EVM 6N5/2.2
60
HP EVM 5N5/2.2

HP EVM 4N5/1.5
40
HP EVM 3N5/1.1

20 HP EVM 2N5/0.75

3
0 5 10 15 20 25 30 m /hr.

2HP-EVM18
260
HP EVM 16F5/15

HP EVM 15F5/15
240

HP EVM 14F5/15
220

200
HP EVM 12F5/11

180

HP EVM 10F5/11
160
Total Head (m)

140

HP EVM 8F5/7.5
120
HP EVM 7F5/7.5

100
HP EVM 6F5/5.5

HP EVM 5F5/5.5
80

HP EVM 4F5/4.0
60

HP EVM 3F5/3.0
40
HP EVM 2F5/2.2

20

3
0 8 16 24 32 40 48 m /hr.

60
HP

SELECTION GUIDE

2HP-EVM32
300

280

260

240

220
HP EVM 10-1F5/18.5

HP EVM 10-3F5/18.5
200
HP EVM 9-0F5/18.5

HP EVM 9-3F5/18.5
Total Head (m)

180
HP EVM 8-0F5/15
HP EVM 8-3F5/15
160
HP EVM 7-0F5/15
HP EVM 7-3F5/15
140
HP EVM 6-0F5/11

HP EVM 6-3F5/11
120
HP EVM 5-0F5/11

100
HP EVM 5-3F5/11

HP EVM 4-0F5/7.5
80
HP EVM 4-3F5/7.5

HP EVM 3-0F5/5.5
60
HP EVM 3-3F5/5.5

HP EVM 2-0F5/4.0
40
HP EVM 2-2F5/3.0

HP EVM 1-0F5/2.2
20

3
0 14 28 42 56 70 84 m /hr.

2HP-EVM45
260

240

HP EVM 9-2F5/30
220
HP EVM 8-0F5/30

HP EVM 8-2F5/30
200

HP EVM 7-0F5/30
180
HP EVM 7-2F5/30

HP EVM 6-0F5/22
160
Total Head (m)

HP EVM 6-2F5/22
140
HP EVM 5-0F5/18.5

HP EVM 5-2F5/18.5
120

HP EVM 4-0F5/15
100
HP EVM 4-2F5/15

HP EVM 3-0F5/11
80

HP EVM 3-2F5/11
60
HP EVM 2-0F5/7.5

HP EVM 2-2F5/5.5
40

HP EVM 1-0F5/4.0
20
HP EVM 1-1F5/3.0

3
0 20 40 60 80 100 120 m /hr.

61
HP

SELECTION GUIDE

2HP-EVM64
200
HP EVM 7-1F5/37
HP EVM 7-2F5/37
190
HP EVM 7-3F5/37
180
HP EVM 6-0F5/37
170
HP EVM 6-1F5/37
HP EVM 6-2F5/30
160
HP EVM 6-3F5/30
150
HP EVM 5-0F5/30
140
HP EVM 5-1F5/30
Total Head (m)

HP EVM 5-2F5/30
130
HP EVM 5-3F5/30

120
HP EVM 4-0F5/22

110
HP EVM 4-1F5/22
HP EVM 4-2F5/18.5
100
HP EVM 4-3F5/18.5

90
HP EVM 3-0F5/18.5
HP EVM 3-1F5/15
80
HP EVM 3-2F5/15
70 HP EVM 3-3F5/15

60
HP EVM 2-0F5/11
HP EVM 2-1F5/11
50
HP EVM 2-2F5/7.5
40

30
HP EVM 1-0F5/5.5
HP EVM 1-1F5/4.0
20

10

3
0 28 56 84 112 140 168 m /hr.

3HP-EVM3
260

240
HP EVM 26F5/3.0

220

HP EVM 22F5/2.2
200

180

HP EVM 18F5/2.2
160
Total Head (m)

140
HP EVM 15N5/1.5

HP EVM 13N5/1.5
120

HP EVM 11N5/1.1
100

HP EVM 9N5/1.1
80

HP EVM 7N5/0.75
60
HP EVM 6N5/0.75

HP EVM 5N5/0.55
40
HP EVM 4N5/0.55

HP EVM 3N5/0.37
20
HP EVM 2N5/0.37

3
0 2.5 5 7.5 10 12.5 15 m /hr.

62
HP

SELECTION GUIDE

3HP-EVM5
260

HP EVM 24F5/5.5
240

HP EVM 22F5/4.0
220

200
HP EVM 19F5/4.0

HP EVM 18F5/4.0
180

HP EVM 16N5/3.0
160
Total Head (m)

HP EVM 14N5/3.0
140

HP EVM 12N5/2.2
120
HP EVM 11N5/2.2

100 HP EVM 10N5/2.2

HP EVM 8N5/1.5
80
HP EVM 7N5/1.5

HP EVM 6N5/1.1
60
HP EVM 5N5/1.1

HP EVM 4N5/0.75
40
HP EVM 3N5/0.55

HP EVM 2N5/0.37
20

3
0 5.5 11 16.5 22 27.5 33 m /hr.

3HP-EVM10
260

HP EVM 22F5/11
240

HP EVM 20F5/7.5
220

HP EVM 18F5/7.5
200

HP EVM 16F5/7.5
180

HP EVM 15F5/5.5

160
HP EVM 14N5/5.5
Total Head (m)

140
HP EVM 12N5/5.5

HP EVM 11N5/4.0
120
HP EVM 10N5/4.0

100

HP EVM 8N5/3.0
80

HP EVM 6N5/2.2
60
HP EVM 5N5/2.2

HP EVM 4N5/1.5
40
HP EVM 3N5/1.1

HP EVM 2N5/0.75
20

3
0 7.5 15 22.5 30 37.5 45 m /hr.

63
HP

SELECTION GUIDE

3HP-EVM18
260
HP EVM 16F5/15

HP EVM 15F5/15
240

HP EVM 14F5/15
220

200 HP EVM 12F5/11

180

HP EVM 10F5/11
160
Total Head (m)

140

HP EVM 8F5/7.5
120
HP EVM 7F5/7.5

100
HP EVM 6F5/5.5

80 HP EVM 5F5/5.5

HP EVM 4F5/4.0
60

HP EVM 3F5/3.0
40
HP EVM 2F5/2.2

20

3
0 16 32 48 64 80 96 m /hr.

3HP-EVM32
300

280

260

HP EVM 11-0F5/22
240
HP EVM 11-3F5/22

HP EVM 10-1F5/18.5
220
HP EVM 10-3F5/18.5

HP EVM 9-0F5/18.5
200
HP EVM 9-3F5/18.5
Total Head (m)

HP EVM 8-0F5/15
180
HP EVM 8-3F5/15

160 UN EVM 7-0F5/15

HP EVM 7-3F5/15
140
HP EVM 6-0F5/11

HP EVM 6-3F5/11
120
HP EVM 5-0F5/11
HP EVM 5-3F5/11
100
HP EVM 4-0F5/7.5
HP EVM 4-3F5/7.5
80

HP EVM 3-0F5/5.5
60 HP EVM 3-3F5/5.5

HP EVM 2-0F5/4.0
40 HP EVM 2-2F5/3.0

HP EVM 1-0F5/2.2
20

3
0 21 42 63 84 105 126 m /hr.

64
HP

SELECTION GUIDE

3HP-EVM45
260

240
HP EVM 9-2F5/30

220
HP EVM 8-0F5/30

HP EVM 8-2F5/30
200

HP EVM 7-0F5/30
180
HP EVM 7-2F5/30

HP EVM 6-0F5/22
160
Total Head (m)

HP EVM 6-2F5/22

140
HP EVM 5-0F5/18.5

HP EVM 5-2F5/18.5
120

HP EVM 4-0F5/15
100
HP EVM 4-2F5/15

HP EVM 3-0F5/11
80

HP EVM 3-2F5/11
60
HP EVM 2-0F5/7.5

HP EVM 2-2F5/5.5
40

HP EVM 1-0F5/4.0
20 HP EVM 1-1F5/3.0

3
0 30 60 90 120 150 180 m /hr.

3HP-EVM64
210

200
HP EVM 7-1F5/37
HP EVM 7-2F5/37
190
HP EVM 7-3F5/37

180
HP EVM 6-0F5/37
170 HP EVM 6-1F5/37
HP EVM 6-2F5/30
160
HP EVM 6-3F5/30

150
HP EVM 5-0F5/30

140 HP EVM 5-1F5/30


Total Head (m)

HP EVM 5-2F5/30
130 HP EVM 5-3F5/30

120
HP EVM 4-0F5/22
HP EVM 4-1F5/22
110
HP EVM 4-2F5/18.5
100 HP EVM 4-3F5/18.5

90
HP EVM 3-0F5/18.5
HP EVM 3-1F5/15
80
HP EVM 3-2F5/15
HP EVM 3-3F5/15
70

60 HP EVM 2-0F5/11
HP EVM 2-1F5/11
50
HP EVM 2-2F5/7.5

40

30 HP EVM 1-0F5/5.5
HP EVM 1-1F5/4.0
20

10

3
0 42 84 126 168 210 252 m /hr.

65
HP

SELECTION GUIDE

4HP-EVM3
260

240
HP EVM 26F5/3.0

220

HP EVM 22F5/2.2
200

180

HP EVM 18F5/2.2
160
Total Head (m)

140 HP EVM 15N5/1.5

HP EVM 13N5/1.5
120

HP EVM 11N5/1.1
100

HP EVM 9N5/1.1
80

HP EVM 7N5/0.75
60
HP EVM 6N5/0.75

HP EVM 5N5/0.55
40
HP EVM 4N5/0.55

HP EVM 3N5/0.37
20
HP EVM 2N5/0.37

3
0 3 6 9 12 15 18 m /hr.

4HP-EVM5
260

HP EVM 24F5/5.5
240

HP EVM 22F5/4.0
220

200
HP EVM 19F5/4.0

HP EVM 18F5/4.0
180

HP EVM 16N5/3.0
160
Total Head (m)

HP EVM 14N5/3.0
140

HP EVM 12N5/2.2
120
HP EVM 11N5/2.2

100 HP EVM 10N5/2.2

HP EVM 8N5/1.5
80
HP EVM 7N5/1.5

HP EVM 6N5/1.1
60
HP EVM 5N5/1.1

HP EVM 4N5/0.75
40
HP EVM 3N5/0.55

HP EVM 2N5/0.37
20

3
0 5.5 11 16.5 22 27.5 33 m /hr.

66
HP

SELECTION GUIDE

4HP-EVM10
260

HP EVM 22F5/11
240

HP EVM 20F5/7.5
220

HP EVM 18F5/7.5
200

HP EVM 16F5/7.5
180
HP EVM 15F5/5.5

160 HP EVM 14N5/5.5


Total Head (m)

140
HP EVM 12N5/5.5

HP EVM 11N5/4.0
120

HP EVM 10N5/4.0
100

HP EVM 8N5/3.0
80

HP EVM 6N5/2.2
60
HP EVM 5N5/2.2

HP EVM 4N5/1.5
40
HP EVM 3N5/1.1

HP EVM 2N5/0.75
20

3
0 10 20 30 40 50 60 m /hr.

4HP-EVM18
HP EVM 16F5/15
260

HP EVM 15F5/15
240
HP EVM 14F5/15

220

200 HP EVM 12F5/11

180

HP EVM 10F5/11
160
Total Head (m)

140
HP EVM 8F5/7.5

120
HP EVM 7F5/7.5

100 HP EVM 6F5/5.5

HP EVM 5F5/5.5
80

HP EVM 4F5/4.0
60
HP EVM 3F5/3.0

40
HP EVM 2F5/2.2

20

3
0 16 32 48 64 80 96 m /hr.

67
HP

SELECTION GUIDE

4HP-EVM32
300

280

260

240

HP EVM 10-1F5/18.5
220 HP EVM 10-3F5/18.5

HP EVM 9-0F5/18.5
200
HP EVM 9-3F5/18.5

HP EVM 8-0F5/15
Total Head (m)

180
HP EVM 8-3F5/15

160 HP EVM 7-0F5/15


HP EVM 7-3F5/15

140
HP EVM 6-0F5/11
HP EVM 6-3F5/11
120
HP EVM 5-0F5/11

HP EVM 5-3F5/11
100
HP EVM 4-0F5/7.5
HP EVM 4-3F5/7.5
80
HP EVM 3-0F5/5.5

60 HP EVM 3-3F5/5.5

HP EVM 2-0F5/4.0
40 HP EVM 2-2F5/3.0

HP EVM 1-0F5/2.2
20

3
0 28 56 84 112 140 168 m /hr.

4HP-EVM45
260

240
HP EVM 9-2F5/30

220
HP EVM 8-0F5/30

HP EVM 8-2F5/30
200
HP EVM 7-0F5/30

180 HP EVM 7-2F5/30

HP EVM 6-0F5/22
160
Total Head (m)

HP EVM 6-2F5/22

140
HP EVM 5-0F5/18.5

HP EVM 5-2F5/18.5
120
HP EVM 4-0F5/15

100
HP EVM 4-2F5/15

HP EVM 3-0F5/11
80

HP EVM 3-2F5/11

60
HP EVM 2-0F5/7.5

HP EVM 2-2F5/5.5
40

HP EVM 1-0F5/4.0
HP EVM 1-1F5/3.0
20

3
0 40 80 120 160 200 240 m /hr.

68
HP

SELECTION GUIDE

4HP-EVM64
210

200
HP EVM 7-1F5/37
HP EVM 7-2F5/37
190 HP EVM 7-3F5/37

180
HP EVM 6-0F5/37
170 HP EVM 6-1F5/37

HP EVM 6-2F5/30
160 HP EVM 6-3F5/30

150
HP EVM 5-0F5/30
HP EVM 5-1F5/30
140
HP EVM 5-2F5/30
Total Head (m)

HP EVM 5-3F5/30
130

120
HP EVM 4-0F5/22
HP EVM 4-1F5/22
110
HP EVM 4-2F5/18.5
100 HP EVM 4-3F5/18.5

90 HP EVM 3-0F5/18.5
HP EVM 3-1F5/15
80
HP EVM 3-2F5/15
HP EVM 3-3F5/15
70

60 HP EVM 2-0F5/11
HP EVM 2-1F5/11
50
HP EVM 2-2F5/7.5

40

30 HP EVM 1-0F5/5.5

HP EVM 1-1F5/4.0
20

10

3
0 56 112 168 224 280 336 m /hr.

5HP-EVM3
260

HP EVM 26F5/3.0
240

220

HP EVM 22F5/2.2
200

180

HP EVM 18F5/2.2
160
Total Head (m)

HP EVM 15N5/1.5
140

HP EVM 13N5/1.5
120

HP EVM 11N5/1.1
100

HP EVM 9N5/1.1
80

HP EVM 7N5/0.75
60
HP EVM 6N5/0.75

HP EVM 5N5/0.55
40
HP EVM 4N5/0.55

HP EVM 3N5/0.37
20
HP EVM 2N5/0.37

3
0 4 8 12 16 20 24 m /hr.

69
HP

SELECTION GUIDE

5HP-EVM5
260

HP EVM 24F5/5.5
240

HP EVM 22F5/4.0
220

200
HP EVM 19F5/4.0

HP EVM 18F5/4.0
180

HP EVM 16N5/3.0
160
Total Head (m)

HP EVM 14N5/3.0
140

HP EVM 12N5/2.2
120
HP EVM 11N5/2.2

HP EVM 10N5/2.2
100

HP EVM 8N5/1.5
80
HP EVM 7N5/1.5

HP EVM 6N5/1.1
60
HP EVM 5N5/1.1

HP EVM 4N5/0.75
40
HP EVM 3N5/0.55

20 HP EVM 2N5/0.37

3
0 6.5 13 19.5 26 32.5 39 m /hr.

5HP-EVM10
260
HP EVM 22F5/11

240

HP EVM 20F5/7.5
220

HP EVM 18F5/7.5
200

HP EVM 16F5/7.5
180
HP EVM 15F5/5.5

160 HP EVM 14N5/5.5


Total Head (m)

140 HP EVM 12N5/5.5

HP EVM 11N5/4.0
120
HP EVM 10N5/4.0

100
HP EVM 8N5/3.0

80

HP EVM 6N5/2.2
60
HP EVM 5N5/2.2

HP EVM 4N5/1.5
40
HP EVM 3N5/1.1

HP EVM 2N5/0.75
20

3
0 12.5 25 37.5 50 62.5 75 m /hr.

70
HP

SELECTION GUIDE

5HP-EVM18
HP EVM 16F5/15
260

HP EVM 15F5/15
240
HP EVM 14F5/15

220

200 HP EVM 12F5/11

180

HP EVM 10F5/11
160
Total Head (m)

140
HP EVM 8F5/7.5

120
HP EVM 7F5/7.5

100 HP EVM 6F5/5.5

HP EVM 5F5/5.5
80

HP EVM 4F5/4.0
60
HP EVM 3F5/3.0

40
HP EVM 2F5/2.2

20

3
0 20 40 60 80 100 120 m /hr.

5HP-EVM32
300

280

260

240

HP EVM 10-1F5/18.5
220 HP EVM 10-3F5/18.5

HP EVM 9-0F5/18.5
200
HP EVM 9-3F5/18.5

HP EVM 8-0F5/15
Total Head (m)

180
HP EVM 8-3F5/15

160 HP EVM 7-0F5/15

HP EVM 7-3F5/15

140
HP EVM 6-0F5/11
HP EVM 6-3F5/11
120
HP EVM 5-0F5/11

HP EVM 5-3F5/11
100
HP EVM 4-0F5/7.5
HP EVM 4-3F5/7.5
80

HP EVM 3-0F5/5.5
60 HP EVM 3-3F5/5.5

HP EVM 2-0F5/4.0
40 HP EVM 2-2F5/3.0

HP EVM 1-0F5/2.2
20

3
0 35 70 105 140 175 210 m /hr.

71
HP

SELECTION GUIDE

5HP-EVM45
260

240
HP EVM 9-2F5/30

220 HP EVM 8-0F5/30

HP EVM 8-2F5/30
200
HP EVM 7-0F5/30

180 HP EVM 7-2F5/30

HP EVM 6-0F5/22
160
Total Head (m)

HP EVM 6-2F5/22

140
HP EVM 5-0F5/18.5

HP EVM 5-2F5/18.5
120
HP EVM 4-0F5/15

100 HP EVM 4-2F5/15

HP EVM 3-0F5/11
80

HP EVM 3-2F5/11

60
HP EVM 2-0F5/7.5

HP EVM 2-2F5/5.5
40

HP EVM 1-0F5/4.0
HP EVM 1-1F5/3.0
20

3
0 50 100 150 200 250 300 m /hr.

5HP-EVM64

200 HP EVM 7-1F5/37


HP EVM 7-2F5/37
190 HP EVM 7-3F5/37

180
HP EVM 6-0F5/37
HP EVM 6-1F5/37
170
HP EVM 6-2F5/30
160 HP EVM 6-3F5/30

150
HP EVM 5-0F5/30
HP EVM 5-1F5/30
140
HP EVM 5-2F5/30
Total Head (m)

130 HP EVM 5-3F5/30

120 HP EVM 4-0F5/22


HP EVM 4-1F5/22
110
HP EVM 4-2F5/18.5

100 HP EVM 4-3F5/18.5

90 HP EVM 3-0F5/18.5
HP EVM 3-1F5/15
80
HP EVM 3-2F5/15
HP EVM 3-3F5/15
70

60 HP EVM 2-0F5/11
HP EVM 2-1F5/11
50
HP EVM 2-2F5/7.5

40

30 HP EVM 1-0F5/5.5
HP EVM 1-1F5/4.0
20

10

3
0 70 140 210 280 350 420 m /hr.

72
HP

DIMENSIONAL DRAWING 2HP (EVM)

D1
W

'X' R Y B

PUMP1 PUMP2
R T R T

ST STPST STP

Ø
H2

HYDRO BOOSTER

F E D H3

DISCHARGE SUCTION
H1
H

L3 L1 L2

VIEW 'X'

DIMENSION L1 D E F H3 D1 W TANK H H1 H2 Ø L2 L3 SUCTION DISCHARGE


mm mm mm mm mm mm mm LITER mm mm mm mm mm mm MANIFOLD MANIFOLD
MODEL
mm mm

2HP-EVM 3 1030 180 350 250 1600 180 400 300L 100 300 1085 610 780 710 50 50

2HP-EVM 5 1030 180 350 250 1600 180 400 50 50


500L 100 300 1370 760 910 860
2HP-EVM 10 1200 210 390 250 1600 250 400 65 65
1000L 100 300 1850 760 910 860
2HP-EVM 18 1345 305 440 250 1600 250 600 80 80
1500L 100 300 1750 1000 1100 1100
2HP-EVM 32 1400 305 440 305 1600 250 600 100 100
2000L 100 300 1985 1100 1200 1200
2HP-EVM 45 1520 360 550 360 1800 500 600 150 150

2HP-EVM 64 1520 360 550 360 1800 500 600 2000L 100 300 1985 1100 1200 1200 150 150

73
HP

DIMENSIONAL DRAWING 3HP (EVM)

D1
W

'X' R Y B

PUMP1PUMP2PUMP3
R T R T R T

ST STPST STPST STP


Ø
H2

HYDRO BOOSTER

F E E D

H3

DISCHARGE SUCTION
H1
H

L3 L1 L2

VIEW 'X'

DIMENSION L1 D E F H3 D1 W TANK H H1 H2 Ø L2 L3 SUCTION DISCHARGE


mm mm mm mm mm mm mm LITER mm mm mm mm mm mm MANIFOLD MANIFOLD
MODEL
mm mm

3HP-EVM 3 1380 180 350 250 1600 230 600 300L 100 300 1085 610 780 710 50 50

3HP-EVM 5 1380 180 350 250 1600 230 600 50 50


500L 100 300 1370 760 910 860
3HP-EVM 10 1590 210 390 250 1600 250 600 65 65
1000L 100 300 1850 760 910 860
3HP-EVM 18 1785 305 440 250 1600 250 600 100 100
1500L 100 300 1750 1000 1100 1100
3HP-EVM 32 1840 305 440 305 1600 250 600 150 150
2000L 125 300 1985 1100 1200 1200
3HP-EVM 45 2070 360 550 360 1800 500 850 150 150

3HP-EVM 64 2070 360 550 360 1800 500 850 2000L 125 300 1985 1100 1200 1200 150 150

74
HP

DIMENSIONAL DRAWING 4HP (EVM)

D1
W

'X'
R Y B

PUMP1PUMP2PUMP3PUMP4
R T R T R T R T
Ø ST STPST STPST STPST STP
H2

HYDRO BOOSTER

F E E E D

H3
DISCHARGE SUCTION
H1
H

L3 L1 L2

VIEW 'X'

DIMENSION L1 D E F H3 D1 W TANK H H1 H2 Ø L2 L3 SUCTION DISCHARGE


mm mm mm mm mm mm mm LITER mm mm mm mm mm mm MANIFOLD MANIFOLD
MODEL
mm mm

4HP-EVM 3 1730 180 350 250 1600 230 600 300L 100 300 1085 610 910 710 65 65

4HP-EVM 5 1730 180 350 250 1600 230 600 65 65


500L 100 300 1370 760 910 860
4HP-EVM 10 1980 210 390 250 1600 250 600 80 80
1000L 100 300 1850 760 910 860
4HP-EVM 18 2225 305 440 250 1600 250 650 100 100
1500L 100 300 1750 1000 1100 1100
4HP-EVM 32 2280 305 440 305 1600 250 650 150 150
2000L 125 300 1985 1100 1200 1200
4HP-EVM 45 2620 360 550 360 1800 500 850 200 200

4HP-EVM 64 2620 360 550 360 1800 500 850 2000L 125 300 1985 1100 1200 1200 200 200

75
HP

DIMENSIONAL DRAWING 5HP (EVM)

D1 W

'X'
R Y B

Ø F E E E E D
PUMP1PUMP2PUMP3PUMP4PUMP5
H2

R T R T R T R T R T

ST STPST STPST STPST STPST STP

HYDRO BOOSTER

H3

SUCTION
DISCHARGE
H1
H

L3 L1 L2

VIEW 'X'

DIMENSION L1 D E F H3 D1 W TANK H H1 H2 Ø L2 L3 SUCTION DISCHARGE


mm mm mm mm mm mm mm LITER mm mm mm mm mm mm MANIFOLD MANIFOLD
MODEL
mm mm

5HP-EVM 3 2080 180 350 250 1600 230 650 300L 100 300 1085 610 910 710 80 80

5HP-EVM 5 2080 180 350 250 1600 230 650 80 80


500L 100 300 1370 760 910 860
5HP-EVM 10 2370 210 390 250 1600 250 650 100 100
1000L 100 300 1850 760 910 860
5HP-EVM 18 2665 305 440 250 1600 250 650 150 150
1500L 100 300 1750 1000 1100 1100
5HP-EVM 32 2720 305 440 305 1600 250 650 200 200
2000L 125 300 1985 1100 1200 1200
5HP-EVM 45 3170 360 550 360 1800 500 1000 200 200

5HP-EVM 64 3170 360 550 360 1800 500 1000 2000L 125 300 1985 1100 1200 1200 200 200

76
EBARA HYDRO BOOSTER SYSTEM
-Total Quality Assurance
EBARA PUMPS MALAYSIA SDN BHD
- Your Reliable Quality Pump Centre
For over 55 years EBARA pumps have been sold and used widely in Malaysia;
satisfying customers and building a reputation for its quality and reliability. EBARA
PUMPS MALAYSIA SDN BHD (EPM) incorporated in January 2001 as a subsidiary
company of EBARA Corporation, Japan under the Fluid Machinery and System
Group, is responsible for sales/marketing of EBARA pumps and related equipments
in Malaysia. EPM originated with one vision in mind : to become the leading pump
company in Malaysia by providing value-added products through continuous
innovation; offering quality pumping solutions to satisfy customers’ needs and
expectations. Thus utmost efforts are focused on satisfying customers’
requirement, at all times.

To serve customers effectively, a strong and competent nationwide dealers network has been developed to
support increasing sales and service requirements of EBARA pumps. Competent engineers and technicians
are available to trouble-shoot and provide prompt after-sales service and ensure EBARA pumps are always
operating in tip-top conditions. Thus you are investing wisely into a peace-of-mind pumping solutions each
time you choose EBARA pump as EPM consider “Quality, Value, Performance” as our motto to serve, always.

Quality that shows


Customer satisfaction is of utmost importance to EBARA and EPM. Each EBARA Hydro Booster
System is 100% factory-set and factory-test to perfection before it is delivered to you. The quality
inspection and testing are carried out by competent and trained personnel to
ensure each component used in the Hydro Booster System works
effectively to meet your demands and site requirements. In addition, EBARA
Certificate of Authenticity and Warranty entitles you to the Original EBARA
field-service support that enhances operating life of EBARA Hydro Booster
System. You will be pleased to know that the EBARA nationwide Dealer
network and Service Centre throughout Malaysia further enhances our
after-sales service support by providing quick and efficient service
whenever the need arises. EBARA’s commitment is simply working
towards excellence by ensuring each EBARA Hydro Booster System unit
you receive is appropriately tested and pre-set according to ISO 9001:2000
procedures and standards accredited by Lloyd’s Register Quality Assurance.
Therefore you are investing wisely into a peace-of-mind pumping solutions
each time you choose EBARA’s pumps and systems.
YOUR FRIENDLY EBARA BUSINESS PARTNERS & SERVICE CENTRE

HYDRO BOOSTER SYSTEM Type UN / UD / HP

Type UN

• Kuala Lumpur • Shah Alam • Butterworth / Penang • Alor Setar • Ipoh


• Kuantan • Melaka • Johor Bahru • Kuching • Kota Kinabalu

e HYDRO-P
p
Ty

Typ
eU
D

EBARA Pumps Malaysia Sdn Bhd Authorised dealer:


6, Jalan TP3, UEP Subang Jaya Industrial Park,
47620 Subang Jaya, Selangor, Malaysia.
Tel : 03-8023 8355 Fax : 03-8023 9355
Email : sales@ebara.com.my
Website : www.ebara.com.my

EPM HB 1008