CM5X0E general magnetic flux vector control inverter user manual
2
CM5X0E general magnetic flux vector control inverter user manual preface
Preface
First of all thank you for purchasing our company’s completely independent development products of CM series
magnetic flux vector control frequency converter.
In CM series inverter adopts modular design to satisfy customers under the premise of general requirements, by
extending the design flexibility to meet the individual needs of customers, industry demands, represents the
application of frequency converter in the future industry trends.Built-in universal extension interface and powerful
speed control and torque control, the process of practical simple closed loop control, PLC, flexible input/output
terminals, pulse frequency, power and stop given the parameter selection, the frequency of a given storage channels
and run the command bound, advocate complementary given control, frequency control, the speed tracking,
encoder break line monitoring, fault self-recovery, built-in brake unit, 28 kinds of fault monitoring, as many as 16
segment multistage speed control, parameter copy, etc.Meeting the requirements of all kinds of complex high
precision transmission, and at the same time it has great value for equipment manufacturing industry customers
with high integration integration solutions to reducethe system cost, to improve the system reliability.
We provide two seed modules for users to choose, namely CM530E function module and CM580E function
modules, modular design, on behalf of the inverter development direction in the future.The difference between
them are shown in table 1:
TABLE1 THE DIFFERENCE BETWEEN THE function MODULES OF CM530E AND CM580E
CM580E:high-performance modular
CM530E:general magnetic flux vector
magnetic flux vector control frequency
control frequency converter
converter
one of the seven DI input for high-speed pulse input
2、double-road AI input, current voltage is optional
INPUT/OUTPUT 3、double-road relay output
TERMINALS 4、simple-road open collector output
5、simple-road high speed pulse output
6、double-road AO output
The open-loop flux vector 1
The open-loop flux vector 2 The open-loop flux vector 1
V/F The open-loop flux vector 2
CONTROLING mode The closed-loop flux vector (additional V/F
purchase of PG card) Open loop torque The closed-loop flux vector (additional
The closed loop torque (additional purchase of PG card)
purchase of PG card)
Control motor Ac asynchronous motor Ac asynchronous motor
Industry-specific
Y Y
module extensions
The I/O expansion
Y Y
card
PG Card Y Y
Fixed-length control Y Y
3
CM5X0E general magnetic flux vector control inverter user manual preface
Magnetic flux vector control is the traditional voltage vector control,and the advantage of the current vector
control mainly embodies the following aspects:
1, large start torque: 0.5 Hz, 180% rated torque (open-loop flux vector control);
2, excellent weak magnetic control algorithm, the realization of high performance high speed control;
3, the precise speed control precision: open-loop flux vector control: plus or minus 0.5% or less (rated synchronous
speed)
The closed-loop flux vector control plus or minus 0.2% or less (rated synchronous speed);
4, more stable speed control stability: open-loop flux vector control: plus or minus 0.3% or less (rated synchronous
speed)
The closed-loop flux vector control plus or minus 0.1% or less (rated synchronous speed);
The torque response of 5, faster performance: 40 ms or less (open-loop flux vector control)
20 ms or less (closed-loop flux vector control).
This manual for CM530, CM530E, CM580 and CM580E inverter operation instruction manual, which USES
CM530E standard is introduced.
This manual provides the user selection, installation, parameter setting, the scene debugging, fault diagnosis and
daily maintenance and the maintenance of the relevant matters needing attention and the instruction.For proper use
of this series of frequency converter, please read this manual carefully in advance, and please keep for later
use.Equipment supporting the customer to send this manual with the equipment to the end user, please.
CM series inverter is in accordance with the following international standards, and some products have passed CE
certification;
IEC/EN61800-5-1:2003 adjustable speed electric drive system safety requirements;
IEC/EN61800-3 2004 adjustable speed electric drive system, the third part: the electromagnetic compatibility
product standard and its specific test method.
4
CM5X0E general magnetic flux vector control inverter user manual safe and notice
Security definition:
In this manual, safety precautions in the following two categories:
! Danger
Because there is a risk of violation operation caused by breaking the rules, it may result in serious injury
and even death
! Caution
Because there is a risk of violation operation caused by breaking the rules,it can lead to moderate
damage or injuries, and the situation of the equipment damage
1. Please install on the metal objects such as flame retardant, away from combustible material.Otherwise may
cause a fire!
! Caution
2.When two or more frequency converter on the same case, please pay attention to the installation location (see
chapter 3 mechanical and electrical installation), and ensure that the cooling effect.
3. You Can't let the wire head or screw off into the converter.Otherwise may cause damage of frequency
converter.
5
CM5X0E general magnetic flux vector control inverter user manual safe and notice
! Danger
3. The frequency converter don't have to withstand voltage test,because this factory product has done testing,
otherwise may cause accident!
4. If all peripheral accessories according to the manual provided by the circuit wiring correctly, otherwise may
cause accident!
1.2 NOTICE
1.2.6 output side with pressure-sensitive devices or improve the condition of the power factor of the
capacitance
Inverter output PWM wave, the output side such as the installation have or to improve the power factor, such as
thunder with varistor easy cause instantaneous over-current and even damage the inverter frequency converter,
please do not use.
7
CM5X0E general magnetic flux vector control inverter user manual product information
Voltage
电压等级Level
2S:Single Phase 110V
2S:单相110V
3S:Single Phase 220V
3S:单相220V 适配电机功率
Adaptable Motor Power
3T:Three Phase 220V
3T:三相220V 标识:
Mark: R75R75 1R51R5 …… 011 015
1.5 …… 11 15
4T:三相380V
4T:Three Phase 380V Motor PowerKW 0.75 1.5
7T:三相690V
电机功率(KW)0.75
7T:Three Phase 690V
……
Map2-1naming rules
2.2 nameplates
Barcode
Map2-2nameplates
Table above represents 530E 2.2KW universal converter ,4.0KW FRENIC-VP
8
CM5X0E general magnetic flux vector control inverter user manual product information
Fit electrical
Input current Output current
Inverter models Input Voltage machine
(A) (A)
(kW)
9
CM5X0E general magnetic flux vector control inverter user manual product information
Fit electrical
Input current Output current
Inverter models Input Voltage machine
(A) (A)
(kW)
160G/185P 307.0/345.0 304.0/340.0 160.0/185.0
2.4 specification
Items Specification
The highest
400Hz
frequency
1K~15kHZ;According to the load characteristic, automatically adjust the
Carrier
frequency carrier frequency.
Major Input frequency resolution
Input frequency Digital setting:0.01Hz
resolution Simulation setting:The highest frequency×0.1%
Control
Open loop flux vector control 1, open loop flux vector control 2, V/F control,
The control
Closed-loop speed open-loop torque, the closed loop torque, the torque control
mode
CM580 and CM580E only
performance
G type machine: 0.5 Hz / 180% (open-loop flux vector control)
Starting torque P type machine: 0.5 Hz / 120% (open-loop flux vector control)
G type machine: 0 hz / 180% (closed-loop flux vector)
10
CM5X0E general magnetic flux vector control inverter user manual product information
Items Specification
Steady speed
precision Open-loop flux vector control :≤±0.5%(rated synchronous speed )
(speed control Closed-loop flux vector control :≤±0.2%(rated synchronous speed )
precision)
V/F curve Three ways: linear model, multipoint, square type V/F curve
Deceleration A straight line or S curve deceleration mode, four kinds of deceleration time
curve Deceleration time range 0.0 s to 3000.0 s
Dc brake frequency: 0.0 Hz ~ maximum frequency
DC brake Braking time: 0.0 ~ 36.0 seconds, braking action current value: 0.0% ~
100.0%
Inching frequency range: 0.00 Hz ~ 50.00 Hz;Deceleration time at 0.0 s to
Inching control
3000.0 s
Simple PLC,
Through the built-in PLC or control terminal realizing at most 16 paraMap
multistage speed
speed operation
operation
Built-in PID Easy to realize process control closed loop control system
Automatic
When grid voltage change, can automatically maintain a constant output
voltage
voltage
regulation (AVR)
"Excavator" characteristics, the torque limit automatically during running,
Torque limit and
prevent frequent over-current trip;The torque control closed-loop vector
control
model is achieved
Peripheral
It can realize the electricity of peripheral equipment safety inspection such as
security
Personal grounding, short circuit, etc
self-check on
Common dc bus function
electricity
Common dc bus Can realize the function of the frequency converter common dc bus more
11
CM5X0E general magnetic flux vector control inverter user manual product information
Items Specification
function
Textile frequency
A variety of triangular wave frequency control function
control
function
Fast current Built-in current limiting algorithm quickly can reduce probability of
limiting function frequency converter to flow and enhance the anti-interference ability
Keyboard
extension cord Customers can use the standard Internet cable to extend the keyboard.
standardization
Run the
Three channels: the operation panel, control terminals given given, serial
command
communication is given.it can switch through a variety of ways
channel
Key lock and Implement part or all of the key lock, define the scope of some buttons, in
selection function order to prevent wrong operation
Electric motor on the short circuit test, input and output phase protection,
Protection
Protection over-current protection, overvoltage protection, under-voltage protection,
And
function overheating protection, overload protection, etc
Options
options
12
CM5X0E general magnetic flux vector control inverter user manual product information
Items Specification
Storage
-20℃~+60℃
temperature
Pollution levels 2
The product
Product IEC61800-5-1:2007
safety standards
13
CM5X0E general magnetic flux vector control inverter user manual product information
14
CM5X0E general magnetic flux vector control inverter user manual product information
Map2-7 450-630KW
15
CM5X0E general magnetic flux vector control inverter user manual product information
Table2-3 Installation hole location and dimension Table(X represents Table 3or8)
R4GB
R75GB
CM5X0-A3S
1R5GB
2R2GB
223 148 166 135 207 φ5.4
R75GB
1R5GB/2R2PB
2R2GB/4R0PB
4R0GB/5R5PB
5R5GB/7R5PB
238 162 171 150 226 φ5.4
7R5GB/9R0PB
9R0GB/011PB
CM5X0-xx4T 015GB/018PB
018G/022P
030G/037P
037G/045P
565 330 252 220 545 φ10
045G/055P
075G/093P
660 460 290 320 635 φ12
093G/110P
16
CM5X0E general magnetic flux vector control inverter user manual product information
110G/132P
875 475 305 340 845 φ12
132G/160P
160G/185P
1100 520 355 380 1066 φ12
185G/200P
200G/220P
5 220G/250P
3 1360 700 380 250 1320 φ14
250G/280P
0
CM5X0-
280G/315P
xx4T
315G/355P
400G/450P
450G/500P
500G/550P
1800 1060 500 - - -
550G/630P
630G
State:530 type 160G-400G for hanging and site dual-use chassis, top down out connection mode.
17
CM5X0E general magnetic flux vector control inverter user manual product information
110G/132P
850 475 325 180 820 φ12
132G/160P
160G/185P
1000 520 373 210 960 φ12
185G/200P
200G/220P
5 1180 580 400 225 1140 φ14
220G/250P
3
0 250G/280P
E 1300 650 423 250 1260 φ14
CM5X0-
280G/315P
xx4T
315G/355P
400G/450P
450G/500P
500G/550P
1800 1000 600 - - -
550G/630P
630G
State:530E type 110G-400G for hanging and site dual-use chassis, outlet and inlet line of the bottom.
18
CM5X0E general magnetic flux vector control inverter user manual product information
2.5.3 The way for leading out the Keyboard and the size of hole on iron plate
19
CM5X0E general magnetic flux vector control inverter user manual product information
Table 2-4 CM5X0 the inverter chooses accessories Table(X represents Table 3or8)
A full explanation of the function and use options, see the relevant options.
If you need more options, please state when ordering.
The external LED CM530-LED LED display and keyboard The CM series general
operation panel operation RJ45 interface
If you need other function module extensions (such as I/O card, PG card, EPS card, etc.), please choose
CM580E series inverter, specify when ordering the function module card.
! Caution
Daily check items:
1) in the operation of the motor sound if an exception occurs
2) whether there was a vibration in the operation of the motor
3) whether frequency converter installation environment changes
4) converter cooling fan is working correctly
5) inverter is overheating
Daily cleaning:
Should always keep the inverter in a clean state.
Effectively remove the inverter on the Table area of dust, prevent dust from entering the internal frequency
converter, especially metal powder.
Effectively remove oil converter cooling fan.
Fans 2~3years
The user can according to the running time determine the change of fixed number of year.
1, the cooling fan may damage the reason: bearing wear, leaf aging.
Criteria: fan blade for cracks, such as whether there are abnormal vibration sound when the phone is switched on.
2, filtering electrolytic capacitor may damage the reason: the poor quality of the input power supply, the
environment temperature is higher, the frequent load jump, electrolyte aging.Judging criteria: presence of liquid
leakage, the relief valve is protruding, electrostatic capacitance measurement, the measurement of insulation
resistance。
CM series frequency converter of six kinds of control mode: the common V/F, open loop flux vector control 1, 2,
open-loop flux vector control open-loop torque control, the closed-loop flux vector control, the closed loop torque
control.
21
CM5X0E general magnetic flux vector control inverter user manual product information
When choosing the inverter must first clear system of variable frequency speed regulation technology requirements,
the application of frequency converter and the load characteristics of occasions, and from the adaptation motor, the
output voltage, rated output current factors such as comprehensive consideration, and then choose to meet the
requirements of aircraft and determine the operation mode.
The basic principle is: motor rated load current should not exceed the rated current of the inverter.Normally
according to the instruction of motor capacity to choose, the attention is rated current of the motor and frequency
converter.Overload capacity for starting and braking of frequency converter to be meaningful.Anything that
short-time overload in the running process, can cause changes in the velocity of the load.If the velocity accuracy
requirement is higher, please consider enlarge a class.
Fan and water pump type: in the low required overload ability, because the load is proportional to the square of the
torque and speed, so the load lighter during low speed running except roots blower () and load on the speed
accuracy because of this kind has no special requirements, so choose square torque V/F.
Constant torque load: most of the load with constant torque characteristics, but in terms of the accuracy of the speed
and the dynamic performance requirements are generally not high.For example: extrusion machine, mixer,
conveyor belt, in the factory the transport trolley, crane, translation agencies, etc.Optional model selection of the
multistage V/F control mode.
Controlled object has a certain dynamic and static index requirements: this type of load is sometimes a hard
mechanical properties at low speed, in order to meet the production process of the control system of static and
dynamic index requirements.Can choose the open-loop flux vector control mode.Controlled object with high
dynamic and static index requirements: for speed control precision and dynamic performance index has a high
requirement and high precision synchronous control occasions, can adopt closed-loop flux vector control mode
(please choose CM58 series inverter).
Please choose according to the braking torque of brake resistance, power and braking unit types, and you can see
Table2-5 for details:
Please choose according to the braking torque of brake resistance, power and braking unit types, and the specific
see Table2-5:
The application of different industry, its braking torque is different:
1, the general reduction in the process of braking, the braking torque is 50% (such as: machine tools, punch press,
spindle servo, brick machine, etc.);
2, vertical load falling in the process of braking, the braking torque is between 100% ~ 150% (such as: construction
elevators, cranes, passenger elevator, centrifuges, etc.).
22
CM5X0E general magnetic flux vector control inverter user manual product information
23
CM5X0E general magnetic flux vector control inverter user manual product information
Note:
24
CM5X0E general magnetic flux vector control inverter user manual product information
1, braking resistor value choice must not be smaller than the resistance tolerance of the recommended in the Table,
such as more than would be likely to damage the brake unit;
2, 2 Table shown in Table x braking resistor in parallel with the two groups, the Table in the x3 Table in three
groups of braking resistor in parallel with, and so on.
3,After 3, inverter type with "B" as the standard built-in brake unit type inverter, not the built-in brake unit, please
choose the corresponding according to its braking torque braking unit model;
4, 18.5 ~ 55 kw G type braking unit is a built-in optional, if you have any requirements, please specify when
ordering, standard configuration without braking unit;
5, 5 s, listed in the Table 15 s refers to the continuous braking time.
25
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
State:When the inverter fluctuation when installation, please install the Map of insulation guide plate.
26
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
>100mm
3.1.2 Machinery installation need to focus on is the cooling problem.So please note the
following points :
1) please install vertical frequency converter, facilitate upward heat, but not the horse.If there are more
contained in the inverter, it's best to install side by side.When installed up and down is required, please refer to
the Map3-1 schematic Map, install insulation guide plate.
2) follow the Map3-1 installation space, to ensure that the inverter heat dissipation space, but decorate, please
consider other components contained in the heat.
3) mounting bracket must be flame retardant material.
4) with metal powder applications, recommended the radiator tank installation, outside seal ark space should be
as large as possible at this time.
27
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
28
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
More than 9 kw CM series inverter adopts sheet metal enclosure, sheet metal shell plate disassembly see
Map3-3.Available tools will be directly under the cover of screws loosen.
! Danger
The cover board removed, avoid the cover off may cause harm to the equipment and the personal
Operation Panel
29
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
The
main
loop of
cocon The main
Air-switch the Control Ground
tacto loop of the
circuit
The Inverter Types (MCCB) input output lead
conductor
r side wires
(mm²)
(A) side (mm²) (mm²)
(A)
wires
(mm²
)
2R2GB 32 20 6 4 1 2.5
4R0GB/5R 25 16 4 4 1 4
5PB
5R5GB/7R 32 25 4 4 1 4
5PB
7R5GB/9R 40 32 4 4 1 4
0PB
380V 9R0GB/01 40 32 6 6 1.5 6
Voltage 1PB
Level 011GB/01 50 40 6 6 1.5 6
5PB
015GB/01 50 40 6 6 1.5 6
8PB
018G/022P 63 63 10 10 1.5 10
022G/030P 80 63 16 16 1.5 16
30
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
The
main
loop of
cocon The main
Air-switch the Control Ground
tacto loop of the
circuit
The Inverter Types (MCCB) input output lead
conductor
r side wires
(mm²)
(A) side (mm²) (mm²)
(A)
wires
(mm²
)
125 10 25 25 1.5 25
037G/045P
0
160 12 25 25 1.5 25
045G/055P
5
180 12 35 35 1.5 25
055G/075P
5
200 16 50 50 1.5 25
075G/093P
0
31
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
Installation
Parets Name function Instruction
Location
The input circuit
Air switch Equipment flow at the downstream power off
of the front-end
Empty opened
Inverter power operation.It should be avoided by contactor
between frequency
contactor frequent fluctuation of the frequency changer electrical operation
converter input
per minute (less than a second) or direct start operation.
side
32
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
制动电阻
Brake resistor
R (-) (+) PB U
三相380V
AC three-phase
power supply
交流输入
380V
S V M
W
T
+24V
NPN PNP 485+
MODBUS接口
MODBUS interface
Default ON OFF
多功能数字输入端子1
Multifunctional digital input terminal 1 DI1 默认
FWDFWD
485-
Default
多功能数字输入端子2
Multifunctional digital input terminal 2 DI2 默认
REVREV
I U AO1 Analog output:
多功能数字输入端子3
Multifunctional digital input terminal 3 DI3 模拟量输出:
I U AO2 0/2-10V
0/2-10V
多功能数字输入端子4
Multifunctional digital input terminal 4 DI4 或0/4-20mA
Or0/4-20mA
GND
Multifunctional digital input terminal 5
多功能数字输入端子5 DI5
Y1
Multifunctional digital input terminal 6
多功能数字输入端子6 DI6
Multifunctional
多功能双极性 bipolar open
Multifunctional digital input terminal 7
多功能数字输入端子7 DI7
COM collector
开路集电极 output terminal
或 HDI
Or 输出端子
CME
COM
Y2
多功能双极 bipolar open
Multifunctional
性开路集电
collector output terminal
COM 极输出端子
Or FM pulse output
或 FM
脉冲输出
CME
TA
AI1 1 relay output
模拟量输入:
Analog Input: TB 继电器1输出
0-10V/4-20mA
0-10V/4-20mA I U TC
AI2
Analog
模拟量输入: Input: RA
I U
0-10V/4-20mA
0-10V/4-20mA
GND RB 2继电器2输出
relay output
RC
(18.5~55KW Parts of brake units match function, if you have any requirements, please specify when orde)。
33
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
制动电阻
Brake resistor
BR530
R (+) (-) U
三相380V 380V
AC three-phase
交流输入
power supply S V M
W
T
+24V
NPN PNP 485+
MODBUS接口
MODBUS interface
ON OFF
多功能数字输入端子1
Multifunctional digital input terminal 1
Default
DI1 默认
FWDFWD
485-
Default
多功能数字输入端子2
Multifunctional digital input terminal 2 DI2 默认
REVREV
I U AO1
Multifunctional digital input terminal 3
多功能数字输入端子3 DI3 模拟量输出:
Analog output:
I U AO2 0/2-10V
0/2-10V
Multifunctional digital input terminal 4
多功能数字输入端子4 DI4 或0/4-20mA
Or0/4-20mA
GND
Multifunctional digital input terminal 5
多功能数字输入端子5 DI5
Y1
Multifunctional digital input terminal 6
多功能数字输入端子6 DI6
多功能双极性
Multifunctional bipolar open
Multifunctional digital input terminal 7
多功能数字输入端子7 DI7
COM 开路集电极
collector output terminal
或 HDI
Or 输出端子
CME
COM
Y2
多功能双极 bipolar open
Multifunctional
性开路集电
collector output terminal
COM 极输出端子
Or FM pulse output
或 FM
脉冲输出
CME
TA
AI1 1继电器1输出
relay output
模拟量输入:
Analog Input: TB
0-10V/4-20mA I U
0-10V/4-20mA TC
AI2
Analog
模拟量输入: Input: RA
I U
0-10V/4-20mA
0-10V/4-20mA
GND RB 2继电器2输出
relay output
RC
Note:18.5Kw ~ 55Kw if users don’t choose built-in brake unit,the wring is as Map3-5 above
34
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
制动电阻
Brake resistor
BR530
R P1 (+) (-) U
AC three-phase
三相380V380V
power supply
交流输入 S V M
W
T
+24V
NPN PNP 485+
MODBUS interface
MODBUS接口
ON OFF
多功能数字输入端子1
Multifunctional digital input terminal 1 DI1 默认 FWD 485-
多功能数字输入端子2
Multifunctional digital input terminal 2 DI2 默认 REV
I U AO1
多功能数字输入端子3
Multifunctional digital input terminal 3 DI3 模拟量输出:
Analog output:
I U AO2 0/2-10V
0/2-10V
多功能数字输入端子4
Multifunctional digital input terminal 4 DI4 或0/4-20mA
Or0/4-20mA
GND
多功能数字输入端子5
Multifunctional digital input terminal 5 DI5
Y1
多功能数字输入端子6
Multifunctional digital input terminal 6 DI6
多功能双极性bipolar open
Multifunctional
多功能数字输入端子7
Multifunctional digital input terminal 7 DI7
COM 开路集电极
collector output terminal
或 HDI 输出端子
CME
COM
Y2
多功能双极 bipolar open
Multifunctional
性开路集电
collector output terminal
COM 极输出端子
Or FM pulse output
或 FM
脉冲输出
CME
TA
AI1 1继电器1输出
relay output
模拟量输入:
Analog Input: TB
0-10V/4-20mA I U
0-10V/4-20mA TC
AI2
模拟量输入:
Analog Input: RA
I U
0-10V/4-20mA
0-10V/4-20mA
GND RB 2继电器2输出
relay output
RC
35
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
9-15KW:
36
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
The main loop of the three-phase 75 ~ 93 kw terminal identification(Safety earthing terminal at the bottom
of the main circuit )
75-93KW:(Safety earthing terminal bottom on the outside of casing)
110-132KW(530type):
160-280KW(530type):
315-630KW(530type):
110-132KW(530Etype):
37
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
160-630KW(530Etype):
Terminal
Names Instruction
Marks
Single-phase power input Ac three-phase 380 v power supply
R、S、T
terminals connection point
Common dc bus input point
Dc bus positive and negative
(+)、(-) The junction of more than 75 kw and
terminals
external braking unit
Braking resistor connected 55 kw and under braking resistor
(+)、PB
terminals connection point
The inverter output
(+)、P1 75-132 - kw dc reactor is optional
terminals
The motor when the cable is too long, because of the influence of the distributed capacitance, easy to produce
electrical resonance, causing the motor insulation damage or produce larger leakage current transducer
over-current protection.Electrical cable length is more than 100 meters, the reactor with ac output.
May not be Shared by earthing terminal and power line and N terminal.
3.2.5 Control terminals and the terminal:
3.2.5.1 Control circuit terminal layout map is as follows:
Map3-5 Control circuit terminal layout map
GND AO1 AO2 GND DI1 DI2 DI3 DI4 DI5 DI6 COM R/A R/B R/C
Y2/ DI7/
10V AI1 AI2 485+ 485- CME COM Y1 24V T/A T/B T/C
FM HDI
39
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
Terminal Terminal
Types function Instruction
Signs Names
DI4-CO Digital (DI6 DI7 terminal function CM530E machine
M Input4 only
DI5-CO Digital
M Input5
DI6-CO Digital
M Input6
DI7-CO
M Digital
/HDI-C Input7
OM
AO1-G Analogous Respectively by the panel on CN2, CN3 dial the
ND Output1 code switch selection decision output voltage or
current.
Analogous
The output voltage range: 0 ~ 10 v
Output AO2-G Analogous
Output current range: 0 to 20 mA
ND Output2
(AO2 terminal function only CM530E CM530
three-phase 380 v 37 kw or more
Optical coupling isolation, bipolar open collector
output
The output voltage range: 0 ~ 24 v
Output current range: 0 ~ 50 mA
Y1-CM Digital Note: digital output of CME from the digital input
E Output1 fields COM is internal, but when they leave the
CME and COM has external nipple (Y1 for + 24
Digital
v drive by default) at this time.When Y1 think
Output
with external power drive, you have to disconnect
the CME and COM external short answer.
Digital
Output2 The same as the function of Y1
Y2/FM
High-speed High-speed pulse output
pulse output
40
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
Terminal Terminal
Types function Instruction
Signs Names
Normally closed
TA-TB Contactand drive ability:AC250V,3A,
terminals
Relay output 1 COSφ=0.4。
Normally closed
TA-TC DC30V,1A
terminals
10V
AI1
电位器
Potentiome CM
ter AI2 5X0E
GND
屏蔽电缆单点接地
Shielded cables single point grounding
41
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
DC9-
24V 24V
30V
(Factory Default FWD)
DI1(出厂默认FWD)
(Factory Default FWD)
DI1(出厂默认FWD)
(Factory Default REV)
DI2(出厂默认REV)
(Factory Default REV)
DI2(出厂默认REV)
DI3
CM5X0E DI3
DI4 CM5X0E
DI4
DI5
DI5
DI6
DI6
Shielded cables 屏蔽电缆单端接地
single point grounding
COM Shielded cables屏蔽电缆单端接地
single point grounding
COM
DI terminal DI接线模式三:当DI拨码开关
connection Mode 3: DI terminal connection Mode 4:
DI接线模式四:当DI拨码开
为PNP模式没有使用外部电源
CN1 in the PNP mode and use an internal power supply CN1 in the PNP关为PNP模式使用外部电源
mode and use an external power supply
24V 24V
DI3 DI3
DI5 DI5
DI6 DI6
Shielded cables屏蔽电缆单端接地
single point grounding
DC9-
COM 30V COM
Shielded cables屏蔽电缆单端接地
single point grounding
Map3-8 Four different modes digital input terminal connection sketch map
Generally need to use shielded cable, and wiring short distance as far as possible, not more than 20 meters.
When the user drive in active way, for the power of the crosstalk of filter necessary measures.
The proposal chooses way contact control. C、digital output terminals:
When digital output terminals need to drive the relay, you should add absorb diode side of the relay coil, otherwise
it will be easy to cause damage of dc 24 v power supply.
Note:Must be properly installed to absorb the polarity of the diode.As the following Map3-9.Otherwise when
digital output terminals output, 24 v dc power supply will be burn out immediately.
42
CM5X0E general magnetic flux vector control inverter user manual installation of mechanics &electronics
24V 24V
CM5X0E 继电器
Relay CM5X0E DC9-
Y1 Y1
30V
继电器
Relay
CME CME
External control
控制端子外部短接片 去掉控制端子
Remove the control
COM terminal jumper COM 外部短接片
terminal external jumpers
内部供电接线图
Internal Power Supply 外部供电接线图
External Power Supply
43
CM5X0E general magnetic flux vector control inverter user manual operation and display
Use operation panel, can function parameters change of the frequency changer, inverter working condition
monitoring and frequency converter operation control (such as start, stop) operation, its appearance and function as
shown in figure 4-1 :
Hz
Uint RPM Digital
indicator A display
%
V
Function
RUN L/D/C FWD/REV TUNE/TC indicator
ENTER
Program EPG
- + QUICK QUICK/
key ESC JOG
JOG Key
Shift
key
Figure 4-1 operation panel diagram 1 (standard LED keyboard 1)
Hz
Uint Digital
RPM
indicator display
A
%
V
Function
indicator
RUN L/D/C FWD/REV TUNE/TC
DOWN ENTER UP
STOP
Stop/Reset
RUN
Run SHIFT RESET key
key
Shift
key
ENTER
Operation panel diagram 2 (optional LED 2 keyboard, if you want to select the keyboard, in order to show)
Keyboard 1 and 2 switching operation mode for: press.prg key and STOP at the same time wait for a "-" let go,
switch is successful.
44
CM5X0E general magnetic flux vector control inverter user manual operation and display
Confirm key (ENTER) Step by step into the menu screen, set parameter confirmation
ENTER
- +
Increasing key (+) Increasing data or function code
key/direction for the direction key, press the key direction of the not
CM series general magnetic flux vector control frequency converter operation panel in operation such as level 3
parameter Settings menu structure.
Three-level menu are: parameter set (menu) - function code (level 2) - function code value (level 3) menu.
Operation process is shown in figure 4-2.
Change改变参数组
Parameter Group Change改变参数组
Parameter Group Change Function code value
改变功能码数值
Figure 4-2 submenus operation flow chart Explanation: the three-level menu operation, can press.prg key or the
ENTER key to return to the secondary menu.
The difference between the two is: press ENTER to save setting parameters after returning to the secondary menu,
and automatically move to the next function code; While press.prg returned directly the secondary menu, not
storage parameters, and returns to the current function code.
Example: the function code F2-02 from 50.00 Hz change the sample set is 20.00 Hz. (gray boxes represent flashing
digits)
PRG ENTER
50.00 F0 F2 F2-00 F2-02
PRG ENTER
Under the outage or running state, can display various state parameters, by function code F7-29 (LED display
parameters) operation and F7-30 (LED stop display parameters), according to a choice whether the parameters
according to the binary you define see chapter 6 F7-29 and function of F7-30 yards.
In stop state, with a total of seven parameters can choose whether show stop condition respectively: set frequency,
busbar voltage, DI input state, the DO output state, voltage analog input AI1, AI2 analog input voltage steps, PLC
running, press the shift key sequence to switch display the selected parameter (the F7-30 display parameters into
binary choice).
In running state, a total of 13 parameters can be displayed, including five fixed display running status parameters:
operating frequency, set frequency, busbar voltage, output voltage, output current is fixed, according to the eight
other display parameters, output power, DI input state, the DO output state, voltage analog input AI1, AI2 analog
input voltage, PID, PID feedback, PLC steps is displayed by the function code F7-29 bitwise (converted to binary)
selection, switch input sequences show that the selected parameters.
Inverter power again to electricity, the display parameter is the default for inverter power lost before the choice of
parameters.
4.4password
Frequency converter provides a user password protection function, when set to zero, F7-51 is the user's password,
set the password before the F7-51 all parameters can be 0 cases according to determine the key, if all have said the
46
CM5X0E general magnetic flux vector control inverter user manual operation and display
current password can be set. If the password is valid, must enter the user password correctly, can enter the ordinary
menu operation, or to enter the show will be 0, twinkle and finally a digital tube, prompt the user must enter the
correct password to action.
If you want to cancel the password protection function, it is only through the password to enter, and F7-51 to 0
press determine key can cancel password protection.
User password protection monitoring parameters, the user password protection situations to normal view
monitoring parameters.
Note: if user forgot password to use the frequency converter, please contact the manufacturer.
Specific cryptographic operations figure see below:
47
CM5X0E general magnetic flux vector control inverter user manual operation and display
CM系列
K1 K2 运行命令
0 0 停止
1 0 停止
K1
0 1 正转 FWD
K2 REV
1 1 反转 COM/+24V
CM系列
SB2 FWD
SB1 DIn
SB3 REV
COM/+24V
48
CM5X0E general magnetic flux vector control inverter user manual operation and display
Choose the vector control operation mode, in front of the frequency converter operation, must be accurate input
motor nameplate parameters, CM5X0E frequency converter on the basis of standard motor nameplate parameters
matching parameters; Vector control method of motor parameters dependence is very strong, to get good control
performance, must be charged with the accurate parameters of the machine.
If the motor can be completely off load, and then the F4-00 please select 2 (complete tuning), and then press the
RUN key on the keyboard panel, the inverter will automatically calculate the motor of the following parameters:
F4-07: no-load current F4-08: stator resistance
F4-09: rotor resistance F4-10: mutual inductance resistance
F4-11: leakage inductance
If the motor and load off completely, the F4-00 please select 1 (static tuning), and then press the RUN key on the
keyboard panel, also can obtain needed parameters.
Note: manufacturers recommend using tuning completely, this will help you to obtain more accurate parameters of
motor.
49
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Output torque converter control, need to have a speed sensorless vector control to achieve better control effect.
5: PG torque control
Torque control + coder can improve the accuracy of torque control.
Tip: choose the vector control method must be done when the motor parameter tuning process, only accurate motor
parameters can give a full play to the superiority of the vector control mode. Motor parameter tuning steps, see
tuning instructions, by adjusting the vector control regulator parameters (F3) can obtain better performance.
2: AI1
3: AI2
51
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Refers to the frequency by the analog inputs to determine. CM5X0E drives provide two analog input terminals, AI1,
AI2 can be 0 ~ 10 v voltage input, can also be used for 4 ~ 20 ma current input, choose by CN1 dial the code switch
on the control panel.
More than 4: period of speed
Choose the way to multistage speed operation. You need to set up F5 "inputs" and FC group "more speed and PLC"
parameter to determine if a given signal and the corresponding relation of a given frequency.
5: simple PLC
Select the simple PLC mode. PLC frequency source is simple and easy, you need to set up the FC group "more
speed and PLC" parameter to determine if a given frequency.
6: PID
The selection process PID control. At this point, you need to set up "PID" FA group, the frequency of the inverter
frequency for PID function after values, including PID given source, refer to quantitative, feedback source meaning
"PID" FA group is introduced.
7: communications given
Refers to the main frequency source by the upper machine through communications given (specific see CM5X0
series inverter serial communication protocol).
8: AI3 given
Refers to the frequency determined by the analog input terminal AI3, the input voltage is 0 ~ 10 v.
9: PULSE, PULSE frequency, given by the control board HDI6 terminal input but need to set DI terminal become
high-speed PULSE input.
Y relative auxiliary
The factory value 0
frequency sources
Relative to the maximum frequency
F0-08 0
Range
Relative to the main frequency source X
1
52
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Y relative auxiliary
The factory value 100%
F0-09 frequency sources
Range set 0%~100%
When selecting frequency source for frequency superposition given (F0-10 to 1 or 3), used to determine the
adjusting range of auxiliary frequency source. F0-08 relative object is used to determine the range, if compared
with the maximum frequency (F0-14), its scope is a fixed value, if the relative to the main frequency source X, then
the scope will change as the change of main frequency X.
Frequency source
selection The factory value 0
The preset
The factory value 50.00Hz
F0-11 frequency
Range set 0.00 Hz~F0-14
When the main frequency source selection set for "digital" or "terminal UP/DN", the function code values for the
frequency of the inverter digital setting the initial value.
54
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
CM5X0E
K 运行方向选择
SB2 FWD
0 正转 SB1 DIn
反转 K REV
1
COM/+24V
Pay attention to the actual deceleration time and set the deceleration time difference.
CM530E, 580 e series frequency converter of four groups of deceleration time choice
The first group: F0-23, F0-24;
The second group: F7-03, F7-04;
The third group: F7-05, F7-06;
The fourth group: F7-07, F7-08.
By multi-function digital input terminals (F5-00 ~ F5-04) choose deceleration time.
Overmodulation
choice The factory value 0
F0-25
0 invalid
Range set
1 valid
Carrier frequency The factory value Determination of models
F0-26
Range set 1.0kHz~15.0kHz
This function adjusting carrier frequency converter. By adjusting the carrier frequency can reduce electrical noise,
to avoid the resonance point of the mechanical system, reduce the line of floor drain current and reducing
interference caused by frequency converter.
When the carrier frequency is low, the output current of higher harmonic component increases, motor loss increase,
the motor temperature increase.
When high carrier frequency, the motor loss is reduced, the motor temperature rise reduced, but the loss of the
inverter increases, the frequency converter temperature increase, the interference
55
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Carrier frequency
adjustment
The factory value 0
options
Initialization parameter
The factory value 0
0 No operation
F0-28
Range set 1 Restore the factory Settings
2 Restore the last user preferences
3 Clear the fault record
To restore frequency parameters
0 Don't move
F0-29
Range set 1 Parameters to upload
Parameters to download
2
This parameter is only suitable for LCD keyboard
Start way
The factory value 0
F1-00 0 Direct start
Range set 1 Speed tracking start
2 Preliminary field start
0: direct start
If start the dc braking time is set to 0, from start frequency to start.
Start the dc braking time set to 0, a dc brake first, then start, applicable to small inertia load reversal may be
produced at startup.
1: the speed tracking and start again
Frequency converter for motor speed and direction first judge, again with tracking to the motor speed of the
corresponding frequency start, no impact on the smooth implementation of rotation of motor start, applicable to
large inertia load of the instantaneous power failure to start again. .
56
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
57
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Fmax
Stop way
The factory value 0
Slowing down
F1-13 0
Range set
Free downtime
1
0: slow down parking
After downtime command effective, frequency converter according to the definition of deceleration mode and the
deceleration time to reduce the output frequency, frequency drop to zero after downtime.
1: free parking
After downtime command effective, inverter immediately put an end to the output. According to the mechanical
load inertia free parking
58
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Fmax
Instantaneous frequency
decrease rate mode
Factory 1
selection to stop
constantly
Choose the deceleration time1
0
(F0-23/F0-24)
F1-24 Choose the deceleration time2
1
(F7-03/F7-04)
Range set
Choose the deceleration time3
2
(F7-05/F7-06)
Choose the deceleration time4
3
(F7-07/F7-08)
When applications in instantaneous power, can use this function to motor with slow way to slow down to zero
speed, if the power recovery at this time, also can again start the motor after recovery time.
The group function code only for V/F control mode, the V/F control for general load such as fan, water pump, or
one inverter with more motor, inverter power is smaller than the motor power level or big 2 above.
V/F curve set Factory 0
0 Linear VF curve
F2-00 1 Multipoint VF curve
Range set 2 Square VF curve
3 1.7 the power curve
4 1.3 the power curve
Fan pump type load, can choose square V/F control:
1: V/F more curve, is suitable for centrifuge dewatering machine, and other special load;
2: square curve of V/F, such as fans and pumps suitable for centrifugal load.
60
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
3 ~ 4: V/F curve for many times, such as fans and pumps suitable for centrifugal load.
内 F7-09
部 F7-10
频 F7-11
率 F7-12
指 F7-13
令 F7-14
设定频率指令
Map5-3 Manual torque Map
F2-03 ~ F2-08 more than six parameters defined section V/F curve.
The value of V/F curve usually set according to the load characteristic of the motor.
Note: V1 V2 < < V3, F1 F2 < F3, low-frequency voltage set too high may lead to motor overheating or even
burning, the inverter may be a loss of speed or over current protection.
61
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
死区时间
In 1 cases improve the low frequency torque vector control mode, the greater the F2-12 torque is bigger, the big but
high electric current may cause damage of motor.
62
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
F3 group function code applies only to the vector control, namely the F0-03 = 1.
63
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
F3-04
F3-05
F3-06
F3-07
F3-00 F3-02
频率
. Frequency
Vector control loop current PI control parameters, the parameters in the asynchronous machine will automatically
receive after complete tuning, generally does not need to be modified, current loop integral controller, integration
time is not used as the dimension, but directly setting the integral gain.Current loop PI gain setting is too big, can
lead to the control loops oscillation, so when the oscillation or greater torque ripple current, can be manually reduce
the PI proportional gain and integral gain here.
AVR function, vector control system with AVR function of V/F control
1 AI1(Analog scaleF3-21)
4 PLUSE GIVEN
5 COMMUNICATION GIVEN
Electric torque limit Factory 150%
F3-21
Range set 0%~200%
Brake torque limit Factory 0
0 Brake torque limit F3-23
1 AI1
F3-22 2 AI2
Range set
3 AI3
4 PLUSE GIVEN
5 COMMUNICATION GIVEN
Brake torque limit Factory 150.0%
F3-23
Range set 0.0%~200%
65
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
F3-21 for electric torque setting, F3-23 for selecting braking torque setting, other set maximum F3-21 and F3-23.
Tip: before tuning, you must set up the correct motor rated parameters (F4-01 ~ F4-06)
0: no operation, namely the tuning is prohibited.
1: static tuning, applicable to the motor and load is not easy to release and cannot rotate the occasion of tuning.
Action: in F0-04 equals 0 mode, set up the function code is 1, and press the RUN button confirmation, inverter will
conduct static tuning.
2: complete tuning
In order to guarantee the dynamic control of the frequency converter performance, please select a rotary tuning,
rotating tuned motor must and load off (light).
Choose rotation after tuning, tuning frequency converter to rest, rest after the tuning machine in accordance with
the acceleration of the F4-12 accelerated to 80% of the rated frequency motor, and maintain a period of time, and
then in accordance with the reduction of the F4-13 speed slowed to zero speed, rotating end of tuning.
Action: set the function code is 2, and press the RUN button confirmation, inverter will rotate the tuning.
Tuning instructions:
When the F4-00 to 0 and then press ENTER, flashing "most cerebral sci-film" and right now, and then press the
RUN button to start the parameters tuning, flashing "most cerebral sci-film" stop at this time.When after the tuning,
display interface back to stop state.In the process of tuning can press the STOP button to suspend the tuning.When,
after the completion of tuning the F4-00 value automatic recovery of 0.
66
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Mutual inductance
Factory modules determination
F4-10 resistance
Range set 0.1mH~6553.5mH
Leakage inductance Factory modules determination
F4-11
Range set 0.01 mH~655.35mH
Fully tuned acceleration Factory 100
F4-12
Range set 1~60000
Tuned in full speed
Factory 100
F4-13 reduction
Range set 1~60000
The encoder pulse
number Factory 1024
F4-14
Range set 1~9999
The encoder input form Factory 0
F4-15
Range set 0~1
The encoder to choose Factory 0
0 ABZ Incremental encoder
1 UVW Incremental encoder
F4-16 Province line UVW incremental
Range set 2 encoder
3 Rotating transformer
4 sin/cos coder
Spiral pole changing
logarithmic Factory 2
F4-17
Range set 1~65535
Rotary encoder
excitation signal Factory 7.0KHz
F4-19 frequency setting
Range set 2.0 KHz~20.0 KHz
! Caution
1,please according to the motor nameplate parameters are set.
2,good control performance of vector control, need accurate motor parameters, accurate parameter identification
from the motor rated parameters is set up correctly.
3,in order to ensure that controlling, please according to the standard of frequency converter adapter motor for
motor configuration, if the motor power and the standard adapter gap is too large, the control performance of
transducer will be markedly reduced.
CM5X0E series inverter standard cell with 5 multi-function digital input terminals, two analog input terminal, if the
system needs more input/output terminals, can choose our expansion card.(X represents Table 3or8)
DI1 terminal function choice Factory 1
F5-00
Range set 0~34
DI2 terminal function choice Factory 2
F5-01
Range set 0~34
F5-02 DI3 terminal function choice Factory 3
67
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Note: when DI7 choice for high-speed pulse input is set F5-05 to 34.
This parameter is used to set digital multi function input terminal corresponding to the function.
The set
Function Explanation
value
Even with the signal input transducer is not action, but will not use jokes
0 No function
set the function to prevent misoperation
Running forward
1
(FWD) Through the external terminals to control the inverter forward and
Reverse running inversion
2
(REV)
Three-wire system Through the terminal to determine the frequency converter operation mode
3
operation control are the three line control mode
turning point move
4
(FJOG) FJOG run for point to move forward, RJOG for dynamic inversion
Reversal point move operation
5
(RJOG)
By external terminal changes when a given frequency increasing frequency
6 Terminal UP
instructions, decreasing.When set the frequency source as digital set set
7 Terminal DOWN frequency can be adjusted up and down
Blockade and output frequency converter, motor parking process is not
8 Free parking controlled by the frequency converter.For large inertia of load and there is
no requirement on parking time, often taken by the method
External fault reset function.With the RESET key on the keyboard function
9 Failure reset RESET)
is the same
Frequency converter and stop, but all operation parameters for the memory
state.Parameters such as PLC, frequency parameters, the PID
10 Run to suspend
parameters.The signal disappears, the inverter back to the front of the
parking status
Normally open input When external fault signal to frequency converter, frequency converter
11
External fault reported failures and downtime
68
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
The set
Function Explanation
value
Multistage speed
12
termina l1
Multistage speed
13 It can be combined by the four terminal state of digital setting of a total of
terminal 2
16 segment speed can be realized
Multistage speed
14 See Table1 detailed combination
terminal 3
Multistage speed
15
terminal 4
Ac-deceleration time
16 Through the state of digital combination of the two terminals to choose
choosing terminal 1
four deceleration time
Ac-deceleration time
17 Detailed portfolio see Table2
choosing terminal 2
Switching frequency Through the terminal to the main frequency source and auxiliary switch
18
source frequency source Y and X
Give a figure for timing when frequency, the terminal can change
Set UP/DOWN reset
19 frequency values of clearing UP/DOWN, return to make a given frequency
(terminal, keyboard)
F0-11 set of values
When the command source for the keyboard, through the terminal to
Run the command terminal control and keyboard control switch
20
switch terminals When for communication, through this terminal can communicate with the
keyboard control
Deceleration is Ensure the inverter is not affected by external signal (except halt
21
prohibited command), to maintain the current output frequency
PID temporary failure, frequency converter to maintain the current
22 PID failure
frequency output
PLC in the execution of suspension, the runtime can be effectively easy to
23 PLC state reset
restore to the PLC through the terminal of the initial state
The pendulum
24 Inverter with center frequency output.The pendulum frequency suspended
frequency suspended
Timer when the input signal effective time to achieve timing time when
25 Timer trigger input
closed, the timing output function effectively.
26 Dc brake command Dc brake command.
External input fault When external fault signal to frequency converter, frequency converter
27
normally closed reported failures and downtime
28 Counter input Count pulse input terminals
29 Counter reset To counter reset
Counting the length
30 The input terminals of length count
of the input
The length of the
31 The length of the reset
reset
Torque control is
32 Ban inverter torque control mode
prohibited
PULSE(pulse)
33 For the pulse input terminals
frequency
34 PID switch Two groups of PID switch terminals
69
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
70
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
CM Series
CM530
K1 K2 Running Commanc
0 0 Stop
1 0 Forward Rotation
K1
0 1 Reverse Rotation K2
FWD
REV
1 1 Stop COM/+24V
CM530
CM Series
K1 K2 Running Commanc
0 0 Stop
1 0 Stop
K1
0 1 Forward Rotation K2
FWD
REV
1 1 Reverse Rotation COM/+24V
71
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
CM Series
CM系列
SB2 FWD
SB1 DIn
SB3 REV
COM/+24V
And:
SB1:Stoping button
SB2:Forward button
SB3:Reverse button
Din is DI1 ~ DI6 function input terminals, at this time should be the corresponding terminal function is defined as 3
function "three-wire system operation control.
3: three line operation mode 2: this pattern can make terminal for Din, run the command given by FWD, direction is
determined by the state of the REV.
The shutdown is commanded by disconnecting Din signal to complet.
CM 5X0E
bit1 bit0
T1 T0
DO0 REL1
And:
SB1: Stoping button
SB2: running button
Din is DI1 ~ DI6 function of input, at this time should be the corresponding terminal function is defined as 3
function "three-wire system operation control.
Terminal change rate UP/DOWN Factory 1.00
F5-12
Range set 0.01~100.00
0:The target frequency
F5-13 UP/DOWN frequency of reference
1:The running frequency
72
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
0V 10V
(0mA) (20mA)
AI
AI -100.0%
0.0%
0V
(0mA)
74
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
CM5X0E series inverter standard unit has more than two function digital output terminals, more than two function
relay output terminals, more than two function analog output terminals, such as the need to increase the relay output
terminal and analog output terminals, can choose and buy the company's expansion card.
Control board relay RELAY1
Factory 2
F6-00 output option
Range set 0~21
Control board relay RELAY2
Factory 1
F6-01 output option
Range set 0~21
Y1 output option Factory 0
F6-02
Range set 0~21
FM terminal output mode
Factory 1
selection:
0 impulse output(FMP)
F6-04
Range set 1 Open collector output switch
2 Used as AO3 output
FMR output option Factory 0
F6-05
Range set 0~21
FMP output selection, impulse
Factory 0
F6-06 output
Range set 0~21
IO - 2 extension board relay Factory 0
F6-07
Range set 0~21
IO - 2 extension board relay Factory 0
F6-08
Range set 0~21
The PLC cycle to After completing a cycle when simple PLC output impulse
8
complete signal of a width is 250 ms
9 Runing time arrival Total run time more than set time output ON signal
When set to the frequency of more than, lower limit and lower
10 In the frequency limit limit of frequency inverter output frequency to reach, frequency,
output ON signal
Direction of rotation
18 Direction of rotation speed value
speed value
When testing the actual length of more than set length, output
20 Length arrival
ON signal
When the torque limit function, stalling protection function
21 The torque limit
automatic action
76
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
The set
Function Range
value
Running
0 0~max output frequncey
frequency
Setting
1 0~max output frequncey
frequency
5 AI1 0~10V
6 AI2 0~10V/0~20mA
Communicaiton For details, refer to <the attachment CM5X0E series inverter communication
7
set protocol>
The Table below the scope of corresponding to the amount shown in the Table below:
AO1Zero bias coefficient(%) Factory 0.00%
F6-12
Range set -100.0%~100.0%
AO1 increase Factory 1.00
F6-13
Range set -10.00~10.00
AO2Zero bias coefficient(%) Factory 0.00%
F6-14
Range set -100.0%~100.0%
AO2 increase Factory 1.00
F6-15
Range set -10.00~10.00
If use "b" Table to show zero, gain with kTable, actual output with YTable, standard output with XTable, actual
output is Y = kX + b;
AO1, AO2Zero bias coefficient100 corresponding 10 v % (20 ma).
Standard output is 0 ~ 10 v (20 ma) corresponding to the analog output Table shows the amount of 0 ~ is the largest.
Commonly used for correction of analog output zero drift and the deviation of the output amplitude output curve
can also be customized for any need:
For example: if the analog output content for running frequency, hope that when the frequency of 0 8 v output 16
(ma) and frequency for maximum frequency, output 3 v (ma), the gain should be set to "0.50", zero bias should be
set to "80%".
AO1min output voltage Factory 0.00v
F6-16
Range set 0.00~10.00
AO1max output voltage Factory 10.00v
F6-17
Range set 0.00~10.00
AO2min output voltage Factory 0.00v
F6-18
Range set 0.00~10.00
AO2max output voltage Factory 10.00v
F6-19
Range set 0.00~10.00
AO output for direct limit output, for part of the customers' need to directly set minimum and maximum effective
FE - 23 set to 1.
77
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Inching operation
Factory 6.00Hz
frequency
F7-00
Range set 0.00Hz~F0-14
Inching to speed up
Factory 1.0s
F7-01 the time
Range set 0.00s~3000.0s
Point move to slow
Factory 1.0s
down time
F7-02
Range set 0.00s~3000.0s
Defining point move when given the frequency of frequency converter and ac - decelaration time, inching process
according to the startup mode 0) (F1-00, direct start and stop the way 0 (F1-13, and stop) to stop.
Point move to speed up the time refers To the frequency converter from 0 hz accelerated To time needed for
maximum output frequency (F0-14).
Inching deceleration time refers to the frequency converter (F0-14) reduction from maximum output frequency to
the time needed for 0 hz.
78
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
When a set frequency Hopping frequency range, the actual operation frequency will be run in closer from the set
frequency Hopping frequency boundary, by setting the Hopping frequency, the frequency converter to avoid negtive
mechanical resonance point.This converter can be set up three jumping Frequency point, if the adjacent two
Hopping Frequency is set to the same value, the Frequency of this function does not work.
PID参数
PID参数1
FA-06 ~ FA-08
PID参数1
FA-18 ~ FA-20
FA-22 FA-23
PID偏差
Map5-12 Hopping Frequency Map
79
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
When more than one inverter drive negtive load caused by different speeds negtive uneven load distribution, load
speed larger inverter with heavier negtive.Droop control features to make the speed droop change as negtive load,
can make the negtive load equilibrium.
This parameter adjustment speed droop of the frequency change of the frequency converter.
When setting frequency is lower than the lower limit frequency action choice for downtime, delay F7-19 action
time.
Output Frequency
FDT Level
FDT Hysteresis
Frequency Detection t
Signal(DO1 RELAY)
ON
80
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Output Frequency
Detected
Amplitude
Frequency
Detection Signal ON ON
(DO1 RELAY)
R
a
n
Y2 +24V AO2 AO3
F7-29 1~8191
g
e
s
et
T/A2 T/B2 T/C2 T/A3T/B3T/C3 CME COM GND GND
81
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Through this parameter will output frequency of frequency converter and negtive load speed.When need to display
negtive load speed set, negtive speed = 120 * * F7 - the number of 31 / motor running frequency.
Showed that the temperature of the IGBT inverter module, different models of IGBT inverter modules over
temperature protection value might be different.
Accumulation running
Factory -
F7-34 itme(minute)
Range set 0~1440
82
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Accumulation running
Factory -
F7-35 itme(day)
Range set 0~65535
Record the motor running time (frequency converter drive enabled), set to 0 can be removed, when running time is
less than 60 seconds is not recorded
Water-supply dormancy
Factory 0
function
F7-37
0 invalid
Range set
1 valid
Parameters are used to realize the application of water supply in sleep and wake up function.
Frequency converter running process, set when the frequency is less than or equal to F1-18 when the lower limit of
frequency and differential pressure less than wake up, after F7-19 delay time, frequency converter to enter a
dormant state, and automatically stop.
If the frequency inverter dormant, and run the current effective, is when set to sleep wake up, wake up dormant.
Process of converter dormancy is valid from stop to the target frequency acceleration by user Settings, and
decelaration time limit, such as the user to select add and subtract time 0, is affected by the F0-23, F0-24.So in the
process of dormancy start user should according to the actual need to adjust ac - decelaration time.
83
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Start protecting
Factory 1
function
F7-41 invalid(Start the terminal command
0
Range set effective direct start)
1 valid
If this parameter is used to improve the safety coefficient, is set to 1, there are two functions:
1) inverter power run command is, you must first run command will remove to avoid running protection state.
2) if the frequency converter fault reset run command still exist, you must first run command will remove to avoid
running protection state.
This prevents motor in unwittingly to run automatically, dangerous.
If set to 0, and frequency converter on the electricity run command exists, namely after F7-42 set the time,
frequency converter directly.。
On electricity directly
Factory 1.0s
F7-42 start delay
Range set 1.0s~60.0s
Any sorts of current
Factory 100.0%
F7-45 arrivals
Range set 0.0% ~ 200.0%
The width of current
Factory 3.0%
F7-46 arrivals
Range set 0.0% ~ 100.0%
When detected current reaches the F7-45, any current to output the function effectively, can choose the relay output
or the output Y.
Any current reaches the width range for any current output function does not change.
84
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
5 9600BPS
6 19200BPS
7 38400BPS
This parameter is used to set data transfer rate between the PC and inverter.Note that set the baud rate of upper
machine and converter must agree, otherwise, the communication can't be, the greater the baud rate, the faster the
communication.
Communication
Factory 0.0s
F8-04 timeout time
Range set 0.0s(invalid)~60.0s
When this function code is set to 0.0 s, communication timeout parameter is invalid.
When the function code set to valid values, if a communication and the interval time of the next communication
beyond the communication timeout, system error will be reported to the communication failures, under normal
circumstances, will be set to null and void, if this parameter is set in the continuous communication system, can
monitor the communication status.
communication pattern
Factory 1
choice
F8-05
0 Free pattern
Range set
1 Standard MOBUS protocol
Linkage proportion
Factory 1.00
from the machine
F8-06
Range set 0.00% ~ 10.00%
This value to adjust the communication frequency ratio, the actual frequency conversion rate = * F8-06
communication frequency
Master-slave machine
Factory 0
selection
F8-07 0:slave machine
Range set
1:master machine
When the set is given priority to, can be achieved by 485 from the machine and the host communication with
frequency and follow actual operation frequency of frequency for the host.
85
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
86
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
F9-19 The lastest fault types Show the lastest fault frequency
F9-20 The lastest fault frequency Show the lastest fault frequency
F9-21 The lastest fault current Show the lastest fault current
F9-22 The lastest fault bus voltage Show the lastest fault bus voltage
87
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
T4 T3 T2 T1 T0
T1 T0
DO0 REL1
F9-24 A recent failure output terminals
According to each state is transformed into the
corresponding decimal display.
The input terminal to ON at the time, its corresponding to
1.OFF to 0.
Through this value to understand the current state of the
digital output signal.
PID control is a common method for process control, based on the charged amount of feedback signal and the target
signal dispersion of proportion, integral, differential operation, to adjust the output frequency of frequency
converter, a negtive feedback system, have been accused of stability in the target amount.Suitable for flow control,
pressure control, temperature control process control, etc.Basic principle of control box, the Map is as follows:
88
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
2 AI2
3 Communication given
4 AI3
5 PULSE given
PID feedback
Factory 0
origination
0 AI1
1 AI2
2 AI1-AI2
FA-03 3 Communication given
Range set
4 AI3
5 PULSE given
6 AI1+AI2
Through this parameter to select the PID feedback channel.
Positive effect:When feedback signal is greater than the given PID for the inverter output frequency drops, can
make PID equilibrium.Such as winding tension of PID control.
Reverse effect:When feedback signal is greater than the given PID for the inverter output frequency is rising, to
make PID equilibrium.Such as rolling tension of PID control.
PID given feedback unit Factory 1000
FA-05 Range is dimensionless PID given
Range set 0~65535 feedback unit.Used as PID given
and feedback shows.
89
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Deviation limits:When the deviation in the range, the PID feedback PID stop adjustment.
90
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
0:no switch
1:switching through DI terminal
PID Parameters of switching 2:switching according to deviation
FA-21
conditions
3:automatic switch accroding to the running
frequency
PID switch deviation1 Factory 0.0%
FA-22
Range set 0.0% ~ 100%
PID switch deviation2 Factory 0.0%
FA-23
Range set 0.0% ~ 100.0%
In some applications, a set of PID parameters can not meet the needs of the whole operation process, need to adopt
different PID parameters under different conditions.
This group of the function code is used to switch of the two groups of PID parameters, the controller parameters of
FA - 18 ~ FA - 20 set mode, and the parameters of FA - 06 - FA - 08, two groups of PID parameters can be achieved
by many digital DI terminal switching function, can also according to the deviation of PID automatic switching.
Select multiple functionDI terminal switch more functionterminal function choice should be set up to 35 (PID
parameter switch terminal), when the terminal was invalid selection parameters group 1 (FA - 06 - FA - 08),
terminal effective choosing parameters in group 2 (FA - 18 ~ FA - 20).
Choosing to automatic switching, given and feedback the deviation between the absolute value is less than PID
parameter deviation switch 1 FA - 22, PID parameters selection group 1.Given feedback and deviation between the
absolute value is greater than the PID switch deviation 2 FA - 23, PID parameters selection in group 2.Deviation in
a given and feedback between switch deviation between 1 and switch 2, the PID parameters for PID parameters of
the linear interpolation values in both groups, as shown in Map5-18.
PID参数
PID Parameters
PID Parameters
PID参数11
FA-06 ~ FA-08
PID Parameters 1
PID参数1
FA-18 ~ FA-20
FA-22 FA-23
PID Deviation
PID偏差
91
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
92
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Pendulum frequency function is suitable for the textile, chemical fiber and other industries and the need to traverse,
winding function.
Pendulum frequency function refers to the inverter output frequency at a set frequency (frequency instruction by
F0-06 and F0-07) as a center for bobbing up and down, the operating frequency in time axis trajectory shown in the
Map below, the oscillation amplitude are set in the FB - 00 and FB - 01, when FB - 01 to 0, the swing is 0, the
pendulum frequency doesn't work.
Setting Frequency Hz
Aw=Fset*FB-01
Frequency
Upper Limit FH
Center +Aw
Frequency Fset -Aw
Frequency
Lower Limit FL Textile Kick Triangular Rising Time
Frequency =FB-03 * FB-04
=Aw*FB-02
Accelerate by Decelerate by
Acceleration Frequency CycleFB-03
Running Deceleration Time
Time
Command
Stop
Command
93
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Simple PLCfunction inverter's a built-in programmable controller (PLC) to complete the multistage frequency
automatic control logic, can set up running time, direction and operation frequency, in order to meet the process
requirements.
CM530E series general magnetic flux vector control frequency converter can achieve 16 segment speed change
control, there are four kinds of deceleration time for choice.
When set by PLC after completion of a cycle can be made of the function more digital output terminal Y1, multiple
function relay RELAY1 output ON signal.Details see F6-00 ~ F6-02.
94
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
Description: FC - 00 ~ FC - 15 symbol determines the simple PLC running direction, if the negtive value, is the
Table in reverse direction.。
95
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
FC-02 FC-14
FC-19 define FC-21 define
accelerate FC-00 decelerate FC-15
0: single end stop operation, after completing a single inverter automatic stop, need operation command given to
start again.
Keep the final end of the 1: a single run, after completing a single frequency converter automatically keep running
frequency and direction of the last paragraph.
2: always circulation, the frequency converter to complete a automatically begin the next cycle after cycle, until a
stop command, system downtime.
0: after power off memory and not stopping to restore 0 period began
After power off memory and not stop after the restart PLC 0 section from the beginning.
1: power lost memories and stop 0 period began to recovery
After power off memory and downtime after restart from zero start.
2: power lost memories and starting from the break point
Useing not memory and restart from the outage time after downtime PLC to segment.
3: power lost memory and starting from the break point
Useing PLC memory and restart from the outage time after downtime period of execution.
Multistage speed priority is when Multistage speed terminal is not complete to 0, prioritise Multistage speed
command value.
100
CM5X0E general magnetic flux vector control inverter user manual Parameter Description
101
CM5X0E general magnetic flux vector control inverter user manual Electromagnetic compatibility
6.1 Definition
Electromagnetic compatibility refers to the electrical equipment in the electromagnetic interference environment,
the interference of the electromagnetic environment such as stable but also the ability to achieve its function.
102
CM5X0E general magnetic flux vector control inverter user manual Electromagnetic compatibility
6.3.6 input power supply add EMCinput filter matters needing attention:
Add EMCinput filter on the power input end, please pay attention to the following;
1, please use in strict accordance with the rating when using filter.Belongs to class I appliance due to the filter, filter
to metal case should be large and install ark metal contact is good, and require good conductive continuity,
otherwise there will be a shock hazard and seriously affect the EMC effect;
2, through the EMC test found that PE filter to must and converter end to receive the same public ground, otherwise
will seriously affect the EMC effect;
3, filter close to the power input end of the frequency converter installation;
April and may not be EMCinput filter used in inverter output filter.
103
CM5X0E general magnetic flux vector control inverter user manual Troubleshootiong and countermeasures
CM5X0E inverter with a total of 29 warning information and the protection function, once the abnormal failure,
protection function, frequency converter to stop output, frequency converter fault relay contact action, and in the
frequency converter fault code shown on the display panel. User before seeking service, can according to this
section suggests checking first, analysis the cause of the problem, find out the solution. If belong to contact the
factory problem, please seek service, with you purchased inverter agents or direct contact with our company.
104
CM5X0E general magnetic flux vector control inverter user manual Troubleshootiong and countermeasures
105
CM5X0E general magnetic flux vector control inverter user manual Troubleshootiong and countermeasures
The following fault of converter may be encountered in the process of using,please refer to the
following simple fault analysis method:
1、Electricity no display:
1)By using Table to check the input power supply converter million rated voltageand frequency
converter is consistent, if the power supply has the question please check and eliminate.
2)Check whether the three-phase rectifier bridge is in good condition, if the rectifier bridge has been
damaged, please seek service.
3)Check whether the charge lamp is lit, if the light is not bright, the fault generally focus on the rectifier bridge
or buffer resistance, if the light is bright, the fault may be in part of switch power supply. Please seek service。
2、Jumped on electric power supply air switch:
1)Check whether there is between the input power grounding or short circuit conditions, eliminate the problems
2)Check whether the bridge rectifier has breakdown, ifdamaged, for services.
3、The motor does not rotate after the operation of the transducer:
1)Check U, V, W between whether there is a balanced three-phase output, if any, for the motor line or itself is
damaged, or the motor due to mechanical causes blockage. Please exclude.
2)Output but the three-phase imbalance, should be damaged for frequency converter drive plate or output
module, please seek service.
3)If there is no output voltage, output module is likely to be driven plate or damaged, please seek service.
4、On electrical inverter show normal, jumped after the operation power supply air
106
CM5X0E general magnetic flux vector control inverter user manual Troubleshootiong and countermeasures
switch:
1)Check whether there is a short circuit between the output module, if so, please seek service。
2)Check whether there is a short circuit or ground between motor fuses, if yes, please exclude..
3)If the trip is occasionally between the motor and the inverter and the distance is far, consider adding the
output AC.
107
CM5X0E general magnetic flux vector control inverter user manual communication protocols
CM5X0E series inverter to provide the RS485 communication interface, and USES MODBUS communication
protocol, the user can through the computer or PLC central control, set the inverter running commands, modify or
read function code parameter, to read the inverter working condition and fault information, etc.
The serial communication protocol defines the content and use the information in the serial communication
format, including host polling (or broadcast) format and host encoding method. Host encoding method including
action function code,the data transmission, error checking, etc. From the machine response is also using the
same structure, its contents include: action confirmation, return data, error checking, etc. If there was an error in
receiving information from machine or cannot fulfill the requirements of the host, it will launch a fault feedback
information in response to the host.
The frequency converter with RS485 bus access "single from" PC/PLC controlnetwork.
CM5X0E series inverter when an asynchronous serial port communication protocol of master-slave ModBus
communication protocol, the network has only one device (host) to establish agreement (called
"query/command"). Other equipment (machine) can only through the provision of data query/command
response of the host, or "query/command" according to the host to respond to action. Host in this refers to the
personal computer (PC), industrial control equipment or programmable logic controller (PLC), etc., from
machine refers to CM5X0E inverter, the host can communicate to a separate from the machine, can also be
released to all the lower machine from broadcast information. For access to the host alone "query/command",
from the machine to return to a information (called response), for radio host information, from the machine
without feedback response to the host.
108
CM5X0E general magnetic flux vector control inverter user manual communication protocols
Network equipment continuously detect network bus (including pause time interval), when the first domain
(domain), after receiving each equipment decoding to judge whether the data sent to yourself. Last transmission
character, after a pause at least 3.5 characters time calibration for the end of the message, a new message can be
started after the pause.
The entire message frames must be as a continuous flow of transmission, if the time frame to complete more
than 1.5 characters before the pause time, receiving equipment will refresh incomplete message and assume that
the next byte is the address of the new message domain, likewise, if a new message in less than 3.5 characters of
time and then a message before, receiving equipment will think it is a continuation of the previous message, this
will lead to an error, because the back of the CRC field value can't be right.
109
CM5X0E general magnetic flux vector control inverter user manual communication protocols
Example: reading from the machine address for inverter F0 01-03 began for two
consecutive parameters
The host sends commands
Frame Fro The High Lower The The CR C END
Head m comma address address numbe numbe C R
START the nd code r of r of low chec C
mac CMD high functio k ch
hine functio n code high ec
addr n code parame k
ess parame ters lo
ters w
>=3.5 >=3.5
0x
character 0x01 0x03 0xf0 0x03 00 0x02 0x07 characte
0b
s rs
110
CM5X0E general magnetic flux vector control inverter user manual communication protocols
If change the control mode F0-03 to VF (F0-03 = 1), run the command source instead of
terminal control (F0-04 = 1), the corresponding data for:
Frame From The Read F0 F0-0 F0-0 F0-0 CR CR END
Head the comma the high 3 4 4 C C
START machin nd code numbe - 03 para para para chec chec
e CMD r of para mete mete mete k k
address parame mete r rs of r high low
ters r valu high valu
valu e is valu e is
es low e low
>=3.5 >=3.5
0xD
characters 0x01 0x03 0x04 0x00 0x01 0x00 0x01 0x07 characte
3
rs
Example: write from the machine address 01 inverter control mode function code for VF
control mode and F0-03 = 1.
The host sends commands
Frame Fro The High Lower Writin Writin CRC CRC END
Head m comma address address g g check check
START the nd code content content high low
mac CMD high low
hine
addr
ess
>=3.5 >=3.5
characters 0x01 0x06 0xf0 0x03 0x00 0x01 0x8B 0x0A characte
rs
111
CM5X0E general magnetic flux vector control inverter user manual communication protocols
Using RTU frame format, message includes a calibration method based on CRC error detection domain, CRC field
tested the content of a message. CRC domain is two bytes, containing 16 bit binary value, after it is calculated by
the transmission equipment, added to the message. Receiving device to calculate the CRC messages are received,
and comparing with receives the CRC in the domain of value, if the two CRC value is not equal, then there is an
error in transmission.
CRC register into 0 XFFFF first, and then call a process to continuous 8-bit bytes of the message and the values in
the current register for processing, only 8 bit data in each character of CRC, effective start bit and stop bit and
parity bits are invalid.
CRC produced in the process, each 8-bit characters individually with register contents exclusive or (XOR), the
results to the lowest effective direction, MSB to 0. LSB can be extracted, if the LSB is 1, register and preset value
dissimilarity or alone, if the LSB is 0,, is not. The whole process will repeat 8 times. At the last one (8) is completed,
the next eight bytes and separate and register the current value of the alien or xa001 (0). The values in the final
register, is all the bytes in the message after execution of CRC value.
CRC were added to the message, the low byte first, then add the high byte. CRC simple function is as follows:
Unsigned int Crc_Cal_Value (Unsigned int *data, Unsigned int length)
{
Unsigned int crcValue = 0xffff;
int I;
while (length--)
{
crcValue ^= *data++;
112
CM5X0E general magnetic flux vector control inverter user manual communication protocols
Note: in the condition of communication written address 0 x9000 parameters for the actual
frequency values, such as written to 4000 to 40.00 Hz
Control command input to the inverter (0 x2000) (write) only
Parameter address Parameter description
0001:Running forward
0002:Reverse run
0003:Is turning point move
0004:Reversal point move
0x2000 0005:Free downtime
0006:Slowing down
0007:Failure reset
1000:Restore the factory parameter
1001:Eliminate malfunction records
113
CM5X0E general magnetic flux vector control inverter user manual communication protocols
0x4000 *****
0x8000
Other: fault code, and the digital tube display fault code
0000:trouble-free
0001:Password mistake
0005:Invalid parameter
0006:Parameter is invalid
0007:Password lock
114
CM5X0E general magnetic flux vector control inverter user manual Appendix
F7-51 set to non-zero value, that is, password protection, set the parameters parameter menu operations must be
after the correct password to enter, in the condition of decryption will F7-51 to 0, cancel the password.
Monitoring parameter is not protected by password.
Function code symbol stated below:
“☆”:Table said the inverter parameters during downtime, operation can be modified
“★”:Table immutable said inverter is in operation
“○”:Table said the parameters is the manufacturer, the user may be changed
“●s”:Table said a frequency converter in the actual values or manufacturer curing value, cannot be changed
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
0:G model
F0-01 The inverter model 0xF001 0 ●
1:P model
Model to
F0-02 Rated Current 0.1A~3000.0A 0xF002 ●
determine
0:open-loop vector one (SVC1)/SVC1
1:open-loop vector two (SVC2)/SVC2
2:common VF control /common VF
F0-03 Control Method 0xF003 0 ★
3:close-loop vector control (FVC)/TQC
4:PG torque control (TQCPG)
5:torque control (TQC)
0:run the command channel operation panel
Command source
F0-04 1:Terminal command channel 0xF004 0 ☆
selection
2:serial port command channel
115
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
116
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
117
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
0:Directly start
F1-00 Boot mode 1:Speed tracking start 0xF100 0 ☆
2:Preliminary field start
0:Starting from the stop frequency
F1-01 Speed tracking way 1:Start from zero velocity 0xF101 0 ★
2:Starting from the maximum frequency
Speed tracking
F1-02 30%~180% 0xF102 100% ☆
maximum current
F1-03 Speed tracking speed 1.0~100.0 0xF103 20.0 ★
F1-04 Start frequency 0.00Hz~10.00Hz 0xF104 0.00Hz ★
Start frequency keep
F1-05 0.0s~36.0s 0xF105 0.0s ★
time
The dc braking
F1-06 0%~100% 0xF106 0% ★
current
118
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
119
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
Instantaneous stop
F1-25 0.0~60.0s 0xF119 1.0 ☆
time to recover
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
The switching
F3-00 1.00Hz~F2-02 0xF300 5.00 Hz ★
frequency F1
Switching frequency
F3-02 F3-00~F0-14 0xF302 10.00 Hz ★
F2
Low speed
F3-04 The proportional gain 0.001~10.000 0xF304 2.000 ☆
121
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
0 - F3-21
1 - AI1
2 – AI2
The electric torque
F3-20 3 – AI3 0xF314 0 ★
limit source
4 - PLUSE given
5 - Communications given
(analog range corresponding to the F3-21)
0 - F3-23
1 - AI1
2 – AI2
F3-22 Brake torque limit 3 – AI3 0xF316 0 ★
4 - PLUSE given
5 - Communications given
(analog range corresponding to the F3-23)
0:There is no function
Motor parameters
F4-00 1:Static tuning 0xF400 0 ★
tuning
2:Completely tuned
Models to
F4-01 Motor 1 rated power 0.4kw~1000.0kw 0xF401 ★
determine
(kW)
Motor rated voltage
F4-02 0V~440V 0xF402 380V ★
(V) 1
The number of motor Models to
F4-03 2~64 0xF403 ★
1 determine
122
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
123
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
0:There is no function ☆
F5-00 DI1 terminal function 1
1:Forward to run (FWD) 0xF500
2:Reverse operation (REV)
3:Three-wire system operation control
4:Forward some dynamic (FJOG)
F5-01 DI2 terminal function 0xF501 2 ☆
5:Reverse point move (FJOG)
6:Terminal UP
7:Terminal DOWN
8:Free parking
F5-02 DI3 terminal function 9:Failure RESET (RESET 0xF502 3 ☆
10:Run to suspend
11:The external input normally open fault
12:Multistage speed terminal 1
13:Multistage speed terminal 2
F5-03 DI4 terminal function 14:Multistage speed terminal 3 0xF503 4 ☆
15:Multistage speed terminal 4
16:Deceleration time choose terminal 1
F5-04 DI5 terminal function 17:Deceleration time choose terminal 2 0xF504 5 ☆
124
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
0 - Two wire1
Terminal command 1 - Two wire 2
F5-11 0xF50B 0 ☆
mode 2 - Three wire system 1
3 - Three wire system 2
Terminal change rate
F5-12 0.00V~100.00V 0xF50C 1.00V ☆
UP/DOWN
UP/DOWN reference 0:The target frequency ☆
F5-13 0xF50D
frequency = 1 :Operating frequency
AI1 minimum input ☆
F5-15 0.00 V~10.00V 0xF50E 0.00
(V)
AI1 minimum input ☆
125
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
corresponding to the
F5-31 -100.0%~100.0% 0xF51F 0.0
minimum input set
(%)
PULSE input ☆
frequency
F5-33 -100.0%~100.0% 0xF521 0.0
corresponding to the
largest set (%)
PULSE input ☆
F5-34 0.00S~10.00S 0xF522 0.10
filtering time (S)
Opening the DI3 0.0S~3600.0S ★
F5-35 0xF523 0.0s
delay time
0.0S~3600.0S 0xF524 ★
F5-36 DI3 trip delay time 0.0s
Opening the DI4 0.0S~3600.0S 0xF525 ★
F5-37 0.0s
delay time
0.0S~3600.0S 0xF526 ★
F5-38 DI4 trip delay time 0.0s
Opening the DI5 0.0S~3600.0S 0xF527 ★
F5-39 0.0s
delay time
0.0S~3600.0S 0xF528 ★
F5-40 DI5 trip delay time 0.0s
DI3 terminal 0- Make effective
F5-41 0xF529 0 ★
effective model 1- Disconnect the effective
DI4 terminal 0- Make effective
F5-42 0xF52A 0 ★
effective model 1- Disconnect the effective
DI5 terminal 0- Make effective
F5-43 0xF52B 0 ★
effective model 1- Disconnect the effective
126
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
127
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
0: operating frequency
F6-09 AO1 output option 0xF609 0 ☆
1: set frequency
2: output current
6: AI2
7: newsletter set
FMP output
F6-11 maximum frequency 0.0~50.0 0xF60B 50.0 ☆
( KHz)
AO1 zero bias
F6-12 -100.0%~100.0% 0xF60C 0.00% ☆
coefficient (%)
F6-13 AO1 gain -10.00~10.00 0xF60D 1.00 ☆
AO1 minimum
F6-16 0.00~10.00V 0xF610 0.00 ☆
output voltage
AO1 maximum
F6-17 0.00~10.00V 0xF611 10.00 ☆
output voltage
AO2 minimum
F6-18 0.00~10.00 V 0xF612 0.00 ☆
output voltage
AO2 maximum
F6-19 0.00V~10.00V 0xF613 10.00V ☆
output voltage
AO3 minimum
F6-20 0.00V~10.00V 0xF614 0.00V ☆
output voltage
AO3 maximum
F6-21 0.00V~10.00V 0xF615 10.00V ☆
output voltage
F7 set of auxiliary functions and man-machine interface function
Inching operation
F7-00 0.00Hz~F0-14 0xF700 6.00 ☆
frequency
Some dynamic
F7-01 0.0s~3000.0s 0xF701 ☆
acceleration time 1.00s
Point move to slow
F7-02 0.0s~3000.0s 0xF702 ☆
down time 1.00s
128
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
The STOP/RESET 2: the terminal control, the STOP button fault reset
F7-27 0xF71B 0 ☆
function function effectively
130
CM5X0E general magnetic flux vector control inverter user manual Appendix
Functi
Contact Mod
on Name Setting range Factory
address ify
Code
Cumulative days -
F7-35 0~65535 0xF723 ●
running
0:the fan running
1: stop running stop in a minute
F7-36 Fan control: 2: with the drive run/stop action 0xF724 1 ☆
3: the radiator temperature more than about 50 ℃
0: invalid
Dormancy of water
F7-37 0xF725 0 ☆
supply 1: effective
Electricity directly
F7-42 1.0s~60.0s 0xF72A 1.0s ☆
start delay time
☆
F7-45 To current 0.0% ~ 200.0s% 0xF72D 100.0%
Any current reaches
F7-46 0.0% ~ 100.0% 0xF72E 3.0% ☆
the width
The agent setting ☆
F7-47 - 0xF72F -
time
The agent set ☆
F7-48 - 0xF730 -
password
☆
F7-49 The agent password - 0xF731 -
☆
F7-51 The user password 0~65535 0xF733 0
131
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
Master-slave machine
F8-07 0 ~ 1 0xF807 0 ☆
model choice
132
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
Over current
F9-06 protection current 100%~200% 0xF906 150% ☆
stalled
Encoder bolt testing ☆
F9-09 0~100 0xF909 5
time
☆
0: warning, but continue to run
Encoder Wire
F9-10 1: warning, slow down 0xF90A 2
processing
2: warning. Free downtime
Automatic reset
F9-11 0~3 0xF90B 0 ☆
failure time
During the fault
self-recovery 0:no action
F9-12 0xF901C 0 ☆
Fault relay action 1:action
choice
Fault self-recovery
F9-13 0.1s~100.0s 0xF90D 1.0 ☆
time interval
The input phase 0:banned
F9-14 0xF90E 1 ☆
protection option 1:allowed
The output phase 0:banned
F9-15 0xF90F 1 ☆
protection option 1:allowed
F9-16 The first fault types 0:trouble-free 0xF910 ●
The second fault 1: inverter unit protection (ERR01)
F9-17 0xF911 ●
types 2: hardware flow (ERR02)
133
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
134
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
PIDgiven feedback
FA-05 0~65535 0xFA05 1000 ☆
value
The proportion
FA-06 0.0~100.0 0xFA06 20.0 ☆
grainP
FA-07 Integration timeI 0.01s~10.00s 0xFA07 2.00s ☆
135
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
Two reverse
FA-27 maximum output 0.00% ~ 100.00% 0xFA21 0.00% ☆
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
frequency
negtivemaximum frequency ~ maximum
FC-10 Multistage speed10 0xFC0A 0.0Hz ☆
frequency
negtivemaximum frequency ~ maximum
FC-11 Multistage speed11 0xFC0B 0.0Hz ☆
frequency
negtivemaximum frequency ~ maximum
FC-12 Multistage speed12 0xFC0C 0.0Hz ☆
frequency
negtivemaximum frequency~maximum
FC-13 Multistage speed13 0xFC0D 0.0Hz ☆
frequency
negtivemaximum frequency~maximum
FC-14 Multistage speed14 0xFC0E 0.0Hz ☆
frequency
negtivemaximum frequency~maximum
FC-15 Multistage speed15 0xFC0F 0.0Hz ☆
frequency
FC-16 PLC running way 1:Single run end of final value 0xFC10 0 ☆
2:keep cycling
PLC 0 segment
FC-18 0.0s(h)~6553.5s(h) 0xFC12 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 0 segment
1:ac-decelaration time2
FC-19 ac-deceleration time 0xFC13 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 1 segment
FC-20 0.0s(h)~6553.5s(h) 0xFC14 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 1 segment
1:ac-decelaration time2
FC-21 ac-deceleration time 0xFC15 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
137
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
PLC 2 segment
FC-22 0.0s(h)~6553.5s(h) 0xFC16 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 2 segment
1:ac-decelaration time2
FC-23 ac-deceleration time 0xFC17 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 3 segment
FC-24 0.0s(h)~6553.5s(h) 0xFC18 0.0s(h) ☆
running time
0:ac-decelaration time1
0:ac-decelaration time1
PLC 4 segment
1:ac-decelaration time2
FC-27 ac-deceleration time 0xFC1B 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 5 segment
FC-28 0.0s(h)~6553.5s(h) 0xFC1C 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 5 segment
1:ac-decelaration time2
FC-29 ac-deceleration time 0xFC1D 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 6 segment
FC-30 0.0s(h)~6553.5s(h) 0xFC1E 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 6 segment
1:ac-decelaration time2
FC-31 ac-deceleration time 0xFC1F 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 7 segment
FC-32 0.0~6553.5s(h) 0xFC20 0.0s(h) ☆
running time
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
0:ac-decelaration time1
PLC 8 segment
1:ac-decelaration time2
FC-35 ac-deceleration time 0xFC23 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 9 segment
FC-36 0.0s(h)~6553.5s(h) 0xFC24 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 9 segment
1:ac-decelaration time2
FC-37 ac-deceleration time 0xFC25 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 10 segment
FC-38 0.0s(h)~6553.5s(h) 0xFC26 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 10 segment
1:ac-decelaration time2
FC-39 ac-deceleration time 0xFC27 0.0s(h) ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 11 segment
FC-40 0.0s(h)~6553.5s(h) 0xFC28 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 11 segment
1:ac-decelaration time2
FC-41 ac-deceleration time 0xFC29 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 12 segment
FC-42 0.0s(h)~6553.5s(h) 0xFC2A 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 12 segment
1:ac-decelaration time2
FC-43 ac-deceleration time 0xFC2B 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 13 segment
FC-44 0.0s(h)~6553.5s(h) 0xFC2C 0.0s(h) ☆
running time
139
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
0:ac-decelaration time1
PLC 13 segment
1:ac-decelaration time2
FC-45 ac-deceleration time 0xFC2D 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 14 segment
FC-46 0.0s(h)~6553.5s(h) 0xFC2E 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 14 segment
1:ac-decelaration time2
FC-47 ac-deceleration time 0xFC2F 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC 15 segment
FC-48 0.0s(h)~6553.5s(h) 0xFC30 0.0s(h) ☆
running time
0:ac-decelaration time1
PLC 15 segment
1:ac-decelaration time2
FC-49 ac-deceleration time 0xFC31 0 ☆
choice 2:ac-decelaration time3
3:ac-decelaration time4
PLC running time 0:s(second)
FC-50 0xFC32 0 ☆
unit choice 1:h(hour)
Multistage speed 0:Multistage speed not first
FC-51 0xFC33 0 ☆
first-way choice 1:Multistage speed first
Multistage speed 0:ac-decelaration time1
level first 1:ac-decelaration time2
FC-52 0xFC34 0 ☆
ac-decelaration time 2:ac-decelaration time3
choice 3:ac-decelaration time4
Multistage speed、
FC-53 PLC directly 0~1 0xFC35 0 ☆
modified
Multistage speed、
PLC directly
FC-54 0~1 0xFC36 1 ☆
modified whether
saved
FD group torque controls parameters group
0:digital setting(FD-01)
Torque command 1:AI1
FD-00 0xFD00 0 ☆
source selection 2:AI2
3:AI3
140
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
Torque numbers
FD-01 -200%~200% 0xFD01 100% ☆
given %
FD-02 Max torque limits % 0%~200% 0xFD02 100% ☆
Torque controns
positive direction
FD-03 0.00~FMAX 0xFD03 50.00Hz ☆
maximum
frequency(Hz)
Torque controns
reverse direction
FD-04 0.00~FMAX 0xFD04 50.00Hz ☆
maximum
frequency(Hz)
Torque order filtering
FD-06 0.000~1.000s 0xFD06 0.000 ☆
time(s)
Torque command
FD-07 0.00s ~ 600.00s 0xFD07 0.00s ☆
speeding up time
Torque order
FD-08 0.00s ~ 600.00s 0xFD08 0.00s ☆
decelaration time
Torque controls
0:For deceleration mode with torque command
FD-09 ac-decelaration 0xFD09 0 ☆
1:With speed limit values for deceleration mode
choice
Positive frequency
FD-10 0~3 0xFD0A 0 ☆
limit
Reverse frequency
FD-11 0~3 0xFD0B 0 ☆
limit
FE group enhancement function group
AIcurve1The
FE-00 0.00V~10.00V 0xFE00 0.00V ☆
minimum input
AIcurve1The
minimum
FE-01 inputcorresponding -100.0%~100.0% 0xFE01 0.0% ☆
set
AIcurve1The
FE-02 minimum input 0.00V~10.00V 0xFE02 0.00V ☆
AIcurve1The
FE-03 minimum -100.0%~100.0% 0xFE03 0.0% ☆
inputcorresponding
141
CM5X0E general magnetic flux vector control inverter user manual Appendix
Funct M
Contact
ion Name Setting range Factory odi
address
Code fy
set
AIcurve1The
FE-04 minimum input 0.00V~10.00V 0xFE04 0.00V ☆
AIcurve1The
minimum
FE-05 inputcorresponding -100.0%~100.0% 0xFE05 0.0% ☆
set
AIcurve1The
FE-06 minimum input 0.00V~10.00V 0xFE06 0.00V ☆
AIcurve1The
minimum
FE-07 inputcorresponding -100.0%~100.0% 0xFE07 0.0% ☆
set
AIcurve2The
FE-08 minimum input 0.00V~10.00V 0xFE08 0.00V ☆
AIcurve2The
minimum
FE-09 inputcorresponding -100.0%~100.0% 0xFE09 0.0% ☆
set
AIcurve2The
FE-10 minimum input 0.00V~10.00V 0xFE0A 0.00V ☆
AIcurve2The
minimum
FE-11 inputcorresponding -100.0%~100.0% 0xFE0B 0.0% ☆
set
AIcurve2The
FE-12 minimum input 0.00V~10.00V 0xFE0C 0.00V ☆
AIcurve2The
minimum
FE-13 inputcorresponding -100.0%~100.0% 0xFE0D 0.0% ☆
set
AIcurve2The
FE-14 minimum input 0.00V~10.00V 0xFE0E 0.00V ☆
AIcurve2The
minimum
FE-15 inputcorresponding -100.0%~100.0% 0xFE0F 0.0% ☆
set
0:LED keyboard
FE-17 Keyboard choice 0xFE11 0 ☆
1:LCD keyboard
Input lack of a
FE-18 sensitivity 0~5000 0xFE12 10 ☆
142
CM5X0E general magnetic flux vector control inverter user manual Appendix
143
CM5X0E general magnetic flux vector control inverter user manual Appendix
DIP switch
AI3 A03 DI
144
CM5X0E general magnetic flux vector control inverter user manual Appendix
触点驱动能力:
Relay T/A-T/B 常闭 terminal
AC250V,3A,COSφ=0.4。
output DC 30V,1A
T/A-T/C 常开 terminal
Auxiliary
J1 控制板 port 28 芯 terminal,与 CM580 系列变频器的控制板连接用
port
145
CM5X0E general magnetic flux vector control inverter user manual Appendix
DIP switch
I:0/4~20mA I:0/4~20mA
A02 A03
U:0/2~10V U:0/2~10V
146
CM5X0E general magnetic flux vector control inverter user manual Appendix
Normally closed
T/A2-T/B2
terminal
Normally
T/A2-T/C2 Contact the drive ability:
openterminal
Relay output AC250V,3A,COSφ=0.4。
Normally closed
T/A3-T/B3 DC 30V,1A
terminal
Normally open
T/A4-T/C4
terminal
Options Description
Open collector signalinput (compatible complementary output, the output
CM580PG1 voltage NPN Encoder, through dial the code switch), open collector with 1:1 the
frequency signal output
Differential signalinput (applicable to line driver output Encoder), including U
CM580PG2
V Wdifferential signal, open collector with 1:1 the frequency signal output
Differential signalinput (applicable to line driver output Encoder), differential
CM580PG3
with 1:1 the frequency signal output
147
CM5X0E general magnetic flux vector control inverter user manual Appendix
appendixB:Map8 CM580PG1terminalMap
CM:互补或NPN电压输出
Complementary or NPN output voltage
PG
OC:开路集电极
Open collector
PG card1terminalfunctionexplanation:
Terminal
Function Response Speed Max Current remark
Mark
Encoder working
15V,COM ―― 100mA ――
power supply
Open collector
electrodesignal or
EncoderA B Zsignal Complementary
ABZ 0~100kHz ――
input port (push-pull) output
signal or NPN voltage
output signal
OUTA,COM
1:1 A Bsignal output 0~100kHz 100mA Open collector signal
OUTB,COM
remark:
1, PGcard1 can only be used in asynchronous machine;
2, compatible complementary output, the output voltage NPN Encoder, through dial the code switch,
specific see Map9.
148
CM5X0E general magnetic flux vector control inverter user manual Appendix
A+,A- Encoder A B
B+,B- Zdifferential 0~500kHz ―― ――
Z+,Z- signalinputport
For the use of
U+,U- encoder U V asynchronous machine
V+,V- Wlocation differential 0~20kHz ―― ordinary encoder, the
W+,W- signalinputport terminal is not
connection
OUTA,COM
1:1 A Bsignal output 0~500kHz 100mA Open collector
OUTB,COM
remark:
1, apply to line driver output form of the encoder;
2, PGcard2 can be applied to asynchronous machine, connected to the differential signal encoder, at
this point, the connection terminal without U V W;
3, PGcard2 can also be applied to the synchronous machine, can be connected with the rotor pole
testing U V W encoder, and the number of requirements of U V W encoder and the number of
synchronous machine is the same, only the number of the same.
appendixB:Map11 CM580PG3terminalMap