ABB Ltd Feeder Protection

Distribution Automation
REF601

Technical Presentation
© 2008 ABB Limited
1MDL07202-YN B
Feeder Protection REF601

Introduction
Introduction
Applicationexamples
Application examples
INSERT PICTURE
HERE ! Hardwareand
Hardware andoptions
options
SIZE: 8.5 X 19.05 CM
Functionality
Functionality
NOTE!
THE GREEN Mechanicaldesign
Mechanical design
BACKGROUND
COLOUR IS ONLY TO Frontpanel
Front panelHMI
HMI
INDICATE THE SIZE
OF THE PICTURE Conclusions
Conclusions
1MDL07202-YN Rev.a
© 2008 ABB Limited
Introduction

INSERT PICTURE

Introduction
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
Feeder Protection REF601

REF601 is a numerical
feeder protection relay,
designed for the
protection and control of
utility and industrial
power systems, in
primary and secondary
distribution network
1MDL07202-YN Rev.a
© 2008 ABB Limited
Feeder Protection REF601
„ Designed for over-current
and earth-fault protection
„ Main application area: Cables,
Lines or transformer feeders
in solidly earthed, resistance
earthed or isolated distribution
networks
„ Brings the advantages of
Rogowski coil current
sensors to medium-voltage
applications
„ The relay for integrated
offering of VD4/ HD4 circuit
1MDL07202-YN Rev.a

breakers with protection and


© 2008 ABB Limited

sensors
INSERT PICTURE

Application
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
examples
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 in directly earthed network
„ Main protection: 3I>, I0>
„ Necessary curves for primary /
secondary distribution
„ IEC NI, VI, EI, LI
„ Special RI
„ Dual mode of earth current
measurement
„ Internal calculation
„ External CBCT input
„ Protection blocking by second
harmonic measurement for
REF601 applied for a feeder in stability during magnetizing
1MDL07202-YN Rev.a

an solidly earthed distribution inrush of transformers


© 2008 ABB Limited

network
REF601 in isolated network
„ Main protection: 3I>, I0>
„ Necessary curves for primary /
secondary distribution
„ IEC NI, VI, EI, LI
„ Special RI
„ Dual mode of earth current
measurement
„ Internal calculation
„ External CBCT input
„ Protection blocking by second
harmonic measurement for
REF601 applied for a feeder in stability during magnetizing
1MDL07202-YN Rev.a

an resistance earthed or inrush of transformers


© 2008 ABB Limited

isolated distribution network


INSERT PICTURE

Hardware
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
and options
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Hardware
„ Power supply
Wide range 24 - 240 V DC / AC
„ Analogue inputs
„ 3 Sensor inputs for phase
„ 1 CT input for E/F
„ Binary input / output
„ 4 binary inputs
„ 6 binary outputs
„ Communication (optional)
„ MODBUS RTU on RS485
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Analog Input
„ Three phase sensor inputs with
rated transformation ratio :
„ 150mV/250A for 50Hz
„ 180mV/250A for 60Hz
Note : These inputs are not
compatible with conventional
1 A / 5 A CT’s.
„ Four selectable nominal primary
current values- 40/80/250/1250A
„ Programmable sensor
calibration factor for higher
over-all accuracy
„ One earth current input (I0)
1MDL07202-YN Rev.a
© 2008 ABB Limited

suitable for conventional 1 A


core balance CT
REF601 Binary input

„ Four galvanically isolated binary


input for
„ Remote trip
„ Remote reset
„ Remote close
„ Remote open

„ Wide operative voltage range


(24 – 240 V AC/DC) for binary
input
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Binary output
„ Two trip outputs
„ Trip 1 : Normally closed
output which opens for 200ms
for tripping CB
„ Trip 2 / Breaker Open :
Normally open output which
closes for 200 ms for tripping
CB
„ One Breaker close contact
„ Two signal outputs
„ Phase over-current trip
„ Earth over-current trip
„ One Unit ready / IRF contact
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Power supply

„ Universal input power supply


with 24 – 240V AC / DC range
„ -30% to +20% tolerance for DC
„ -15% to +10% tolerance for AC
1MDL07202-YN Rev.a
© 2008 ABB Limited
Functionality

INSERT PICTURE

Functionality
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Protection functions
Protection functions IEC 60617 ANSI
Non Directional Over-current , Low set ( DMT or IDMT ) 3I> 51
Non Directional Over-current, High set ( DMT or Inst. ) 3I>> 50/51
Non Directional Over-current, High set ( DMT or Inst. ) 3I>>> 50
Non Directional Earth-fault, Low-set, ( DMT or IDMT ) I0> 51N
Non Directional Earth-fault, High-set ( DMT or Inst. ) I0>> 50N/51N
3-phase Transformer Inrush detector 3I2f> 68
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Breaker Control

„ Dedicated push - buttons for


local breaker control
„ Dedicated binary Inputs for
remote breaker control
„ Optimum duty outputs for
breaker control
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Measurements
„ RMS value of fundamental component
„ Default display
Most loaded Phase - Amps
Earth current - % nominal
„ Selectable display
Phase currents - Amps
Earth current - % nominal
OR
Phase currents - % nominal
Earth current - % nominal
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Recorded data
„ Current values for I1, I2, I3 and I0 are
recorded for two trip events
„ Record length of 15 samples @ one
sample/cycle
„ 5 samples pre-trip and 10 samples
post-trip
„ Trip counter
„ Phase trip and Earth trip counters –
cannot be reset
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Events
„ Last five events
„ Events triggered by protection trip,
Relay fault, 4xBI
„ Event log contains
Analog values of I1, I2, I3 and I0
4xBI status , 4xBO status, Unit Ready
status and fault code
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Safety
„ Continuous monitoring of
„ Memory circuits (RAM, ROM,
EEPROM)
„ Internal supply voltages
„ Hardware and software configuration
„ Indication by Ready LED
„ Protection blocking on critical internal
relay failure to avoid unwanted trip
„ Non-volatile memory for setting
values and fault recorded information
„ Operation indications and LED’s
showing status at the fault
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Access Control and traceability

„ Role based access control


„ Three level access
„ Operator
„ Setting
„ Admin
„ Administrator programmable
password
„ Version information
„ Product type, Software version
„ Model name
„ Nominal primary current
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Test functions

„ Hardware test
„ LCD test
„ Keyboard test
„ LED test
„ BI test
„ BO test
„ Serial EEPROM
„ Trip output test
1MDL07202-YN Rev.a
© 2008 ABB Limited
INSERT PICTURE

Communication
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Communication option

„ Communication on MODBUS
RTU protocol
„ RS 485 port for communication
„ Selectable data transfer rates
2400 … 38400 baud

RS 485 Serial Bus


1MDL07202-YN Rev.a
© 2008 ABB Limited
INSERT PICTURE

Mechanical
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
design
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Mechanical Dimensions

„ Compact dimensions for new and


retrofit installations
„ Height : 160 mm
„ Width : 130 mm
„ Depth : 101 mm
„ Weight : 1,2 Kg
„ Ingress protection
„ IP 42 on front when panel mounted
„ IP 20 on Top, Side, Bottom, Rear
1MDL07202-YN Rev.a
© 2008 ABB Limited
© 2008 ABB Limited
1MDL07202-YN Rev.a

REF601 Mechanical Dimensions


© 2008 ABB Limited
1MDL07202-YN Rev.a

REF601 Circuit Breaker Mounting


© 2008 ABB Limited
1MDL07202-YN Rev.a

REF601 Panel Mounting


INSERT PICTURE

Front panel
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
HMI
INDICATE THE SIZE
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Front panel HMI
Three dedicated LEDs: Ready, Start,Trip

2 x 16 character Phase fault and Earth


LCD Display Fault Indications

CB Control buttons
1MDL07202-YN Rev.a
© 2008 ABB Limited

ESC button

Navigation buttons
Enter button
INSERT PICTURE

Conclusions
HERE !
SIZE: 8.5 X 19.05 CM
NOTE!
THE GREEN
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Product summary
„ Sensor input for phase current
„ External CBCT input for earth current
„ Internal calculation of earth current
„ Three-stage overcurrent protection
„ Two-stage earth-fault protection
„ Magnetizing inrush detection
„ Control of circuit breaker
„ Local and remote control
„ Five event logs
„ Two fault records of analogue value
„ Non-resettable trip counter
„ On-line measurements
„ Comprehensive local HMI
„ Universal auxiliary supply rating
„ Circuit breaker or panel mounting
„ Optional Modbus communication
1MDL07202-YN Rev.a
© 2008 ABB Limited

„ Non-volatile memory
„ Access control
„ Self-supervision
„ Built-in test funcionality
REF601 Selection and ordering data

REF601BAA46AA1XA

Sr. No. Description

Brand identity
1
RE_ series relay RE
Main application
2
Feeder protection with control F
Series identity
3
60_ series 601
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Selection and ordering data

REF601BAA46AA1XA

Sr. No. Description

Standard
4
IEC B
Analog Input / Output
5
3 sensor and ground CT A A
Binary Input / Output
6
4 BI + 6 BO 4 6
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Selection and ordering data

REF601BAA46AA1XA

Sr. No. Description

Serial communication
7 With RS 485 A
None N
Communication protocol
8 Modbus RTU A
None N
Power supply
9
24 – 240V AC / DC 1
1MDL07202-YN Rev.a
© 2008 ABB Limited
REF601 Selection and ordering data

REF601BAA46AA1XA

Sr. No. Description

Vacant digit
10
Vacant X
Version
11
Version 1.0 A
1MDL07202-YN Rev.a
© 2008 ABB Limited
INSERT PICTURE
HERE ! Please visit our
SIZE: 8.5 X 19.05 CM
website for the latest
NOTE!
THE GREEN product information
BACKGROUND
COLOUR IS ONLY TO
INDICATE THE SIZE www.abb.com/substationautomation
OF THE PICTURE
1MDL07202-YN Rev.a
© 2008 ABB Limited

Você também pode gostar