Você está na página 1de 44

Areas of use

Sentron
Benefits

Highlights

Functions

Power Management
Technical data

Installations /
Assembly

Configuration

System
Integration

Systemintegrati
on

Ordering
information
Need for Power Management –
World-Shaking Issues
D I A
Dwindling oil supplies
-I N
Global heating

A I N
I T R
S

Rising power costs


D I A
Emission taxes

- I N
A I N
I T R
S
More efficient power utilization against rising power costs
and for our environment 3C – Combat Climate Change
SENTRON PAC3200 Industry Sector
Slide 2/48 A&D/BD - CD 2008 - Subject to modifications
Customer Concerns

D I A
§ Increasing cost pressure
- I N
A I N
I T R
à Solution: Continuous reduction of operating costs
S
§ High power costs through rising power prices

à Solution: Shifting high-load to low-load times,

D I A
optimizing power costs, raising power awareness

- I N
Reduction of operating costs through active power management
A I N
§
T R
Reduction of power procurement and operating costs by 5-20% (typical)
§
SI (typical)
Short ROI of < 2 years

SENTRON PAC3200 Industry Sector


Slide 3/48 A&D/BD - CD 2008 - Subject to modifications
Power Management Reveals Saving Potentials

D I A
- I N
A I N
I T R
S

D I A
- I N
A I N
I T R
S
Optimization of operating costs with significant saving potential
through transparency and allocation of consumption costs.
SENTRON PAC3200 Industry Sector
Slide 4/48 A&D/BD - CD 2008 - Subject to modifications
SENTRON Power Management

D I A
Areas of use
- I N
Benefits
A I N
Highlights
I T
“ You cannot manage
R what you cannot measure”
Functions
S
Technical data

Installations /
Assembly

Configuration

System
D I A
Integration

- I N
Systemintegrati
on
A
“ You cannot manageI N EFFECTIVLEY
Ordering
I T R
information
S what
you cannot measure RELIABLY”
SENTRON PAC3200 Industry Sector
Slide 5/48 A&D/BD - CD 2008 - Subject to modifications
Market Requirements

D I A
- I N
I N
Requirements in the field of low-voltage
A
power distribution:
-
T R
Transparency of power flows
I
S
from the infeed to the consumer
- Precise detection of all consumption
data throughout the entire power distribution
- Effortless integration in power management
or process control systems
D I A
-
I N
Clearly structured display of the values directly
-
A I N
on the measuring point with sound readability

I T R
S
Power Monitoring Device
SENTRON PAC3200
SENTRON PAC3200 Industry Sector
Slide 6/48 A&D/BD - CD 2008 - Subject to modifications
SENTRON PAC3200
D I A
- I N
A I N
I T R
S

D I A
- I N
A I N
I T R
S

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à at home in every sector
Applications

D I A
Infrastructure &
- I N
institutions
A I N
ITR
n Hospitals
n Airports
Industry
n Train stations
n Water works
S nProcess industry
nOil & gas
n Sewage treatment plants
nChemical & pharmaceutical
n Waste disposal plants
nMetal
n Schools / universities
nPaper
n Official buildings
n Production industry
n Etc.

D I A nMechanical engineering
nMetal

Trade & - I N nFood, beverages & tobacco


nSemiconductors

commerce
A I N n Commercial businesses
n Etc.

n Office buildings
I T R
n Shopping malls
n Multi-story buildings
n Gas stations
S
n Restaurants
n Craft businesses
n Etc.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à high performance, low cost!
Highlights

D I A
I
§ Measurement of over 50 parameters such as VPH-N / VPH-PH /
Amps / VA, ±W, ± kvar / PF / freq. THD with min., max.- N
and average values
A I N
I T R
§ Can be used for single-phase measurements and also
S
multi-phase measurements in 3 and 4-wire networks
§ High measuring accuracy for work, Class 0.5 S
acc. to IEC62053-22
§ Current measurement via x/1A or x/5A current transformer
§ Can be connected directly to industrial networks up to
D I A
I N
3~690/400V *) AC (CATIII), higher voltages via voltage transformer
§ Large graphic LCD display with user friendly-navigation via function keys
§ Compact yet Powerful : Depth only A
I N
§ IP65 on the front throughS
R
IT seal
standard
51mm

*) 500V max. (Uph-ph) for variants with low voltage DC power supply (7KM2111-1BA00-3AA0)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à high performance, low cost!
Highlights

D I A
I N
§ 1x Digital Input / 1x Digital Output as Standard feature
-
§ Import / Export of Energy Parameters
A I N
§ Monitoring of Limit Values
I T R
§ Integrated Ethernet interface Sfor network connection.
§ Supports SEAbus over Ethernet or Modbus TCP protocol
via the integrated Ethernet interface.
§ Plug-in extension modules such as
§ PAC PROFIBUS DP with PROFIBUS DPV1 protocol
D I A
- I
§ PAC RS485 with Modbus RTU or SEAbus protocolN
A I N
§ Coverage of all typical power supplies with only 2 models:

I T R
§ Wide range AC/DC power supply: 95...240VAC ±10% / 50/60Hz &
S 110...340VDC ±10%
§ Low voltage DC power supply: 22.....65VDC ±10%
§ Free configuration software included in the packaging of each meter.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à certified for USA and Canada
Certificates

D I A
- I N
§ IP65 on the front
I N
A § Device class PICQ
I T R § File number: E314880
S § Over voltage category III
§ UL certified for voltages up
to 600V *)

I A
§ UL 61010-1, 2nd Ed.
D
- I N
Safety of Electrical Equipment for Measure-
ment, Control and Laboratory Use

A I N Part 1: General Requirements

I T R § CAN/CSA-C22.2 NO. 61010-1-04, 2nd Ed.


S Safety of Electrical Equipment for Measure-
ment, Control and Laboratory Use
*) 500V max. (Uph-ph) for variants with low voltage
DC power supply (7KM2111-1BA00-3AA0)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à accurate, transp. and reliable!
Functions

D I A
Accurate energy measurement
I N
§ Meets the precision requirements of the-0.5S class in compliance with
A
IEC62053-22 for static meters for I N
active energy
I T R
Transparency in energy S matters
§ 10 energy meters for active, reactive and apparent energy constantly monitor
energy consumption in the system for
import and export, broken down into high and low tariffs
§ SENTRON PAC3200 supplies the necessary average active and reactive
D I
power demand values for the creation of load profilesA
Protection against unauthorized access - I N
A I N
§ Energy and parameter data can be protected against unauthorized access by

I T R
the integral password protection
S are recorded by a configuration counter and can
§ Changes to parameterization
be read out via an interface

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à supplies the details!
Functions

D I A
Instantaneous rms values
- I N
Voltage

A I N
phase-phase / phase-neutral ●
Current

I T
Apparent, active and reactive power R per phase
per phase and total


Power factor
Frequency
S per phase and total ●

THD for voltage and current per Phase ●
Min.- / max.- values ●
Average values over all phases ●
Energy measurement
Active energy
D I A
import / export; high / low tariff ●/●
Reactive energy
I N
inductive / capacitive ; high / low tariff

-
●/●

Apparent energy

A I N
high / low tariff
Active and reactive power demand values per measuring period ●

ITR
Amount of measuring periods to store 1

S
Measuring period interval selectable
Min.- / max.- values for power within the measuring period
Operating hours meter (load)
1…60 min.



Universal counter (e.g. to count the energy pulses of a external kWh / kvarh meter) ●

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à monitors, communicates - and more!
Functions

D I A
Accuracy
- I N
Voltage

A I N ±0,3%
Current
Power

I T R ±0,2%
±0,5%
Active energy

Reactive energy
S Class 0,5S according
to IEC62053-22
Class 2 according
to IEC62053-23
Monitoring functions
Limit monitoring up to 6 limits
Simple logical operations possible for limits ●
Unbalance
Communication
voltage and current

D I A ●

Ethernet
Protocols
- I
integrated
N 10 Mbit/s
SEAbus TCP or

Profibus DP
A I Nvia optional extension module
Modbus TCP

ITR ●
Modbus RTU / SEAbus via optional extension module
In-/Outputs
Digital input
Digital output
S multifunctional
multifunctional
1
1
Miscellaneous
Password protection ●
Certifications USA (UL) and Kanada (CSA) ●

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à clearly arranged!
Functions

D I A
Displays in plain text
I N
§ Large, full graphics LCD with backlit and-plain text displays are easy to read even
A
at a distance and in poor lighting I N
conditions
I T R
S
adaptable on
menu-assisted
the lighting
operation
conditions

D I A
- I N
Plain text

A I N
4 function
Direct navigation in
the measurement
displays

§ To adjust the display S I T R keys

for ambient conditions, it is possible to set contrast,


menus

brightness and whether the screen should be displayed with inverted colors.
§ Programmable dimming or blanking time to reduce energy and to increase
backlight lifetime.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à user-friendly!
Functions

D I A
Operation in a choice of languages
- I N
in English, German, Portuguese, A I N
§ Intuitive, menu-assisted user guidance via function keys and plain text displays
Turkish, Spanish, Italian, French, Chinese
and Russian.
I T R
S 8 selectable languages
delivered in the device,
additional languages can
be downloaded via
configuration software

D I A
- I N
A I N 4 function
keys Direct navigation in the

I T R measurement menus

S
§ Direct navigation in the measurement menus for practiced users
the arrow keys can be used to move directly to the next measurement display

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à 0100011110000011!
Functions

D I A
Multi-functional digital input and output
- I N
§ Digital input:
A I N
I T R
§ Counting input for kWh, kvarh – impulses (S0)

S
§ Status monitoring e.g. for switching devices
§ HT/LT - tariff switching 1xDI / 1xDO

§ Synchronization of measuring periods

D I A
- I N
A I N
§ Digital output:
I T R
S
§ Pulse output for kWh, kvarh – impulses (S0)
§ Alarm output for signaling limit violations
§ Operating status display of the SENTRON PAC3200
§ Display of direction of rotation
§ Switching output to remote control via system software

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à everything under control!
Functions

D I A
Monitoring and service
- I N
§ Limit monitoring:
A I N
I T R
§ Monitoring of up to 6 limits for overrange and undershoot

S
§ Voltages, currents, power, power factors, THD,
frequency or asymmetry U/I can be monitored
§ Delay time and hysteresis can be set
§ Logical AND / OR operations possible for limits
§ Result of logical operation can itself be used like

I
the limits to trigger a wide variety of actions
D A
§ Actions to be triggered in case of limit violation can be programmed
§ Switching of digital output
- I N
§ Communication via interfaces
A I N
T R
§ Universal meter for adding up all events
I
S
§ Monitoring of phase symmetry for voltage and current in order to avoid unbalanced
loads
§ Operating hours meter for monitoring the running time of connected consumers
such as motors, pumps, machines, etc.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à perfect communication!
Functions

D I A
I N
Effective communication via Ethernet or serial
-
Interface modules

A N
I§ 10 Mbit/s Ethernet interface provided as standard
I T R for network communication. IP-Address, subnet
S mask and gateway can be parameterized from
front of device or via configuration software
10Base-T
§ Supports SEAbus over Ethernet or Modbus TCP

I A
protocol; configurable on the device or via confi-
D
- I N
guration software.
§ Mounting
N location for extension modules such as
AI § SENTRON PAC PROFIBUS DP
I T R
S § SENTRON PAC RS485
for serial communication (RS485)
Module
mounting
location

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à perfect communication!
Functions

D I A
Effective communication via PROFIBUS DPV1
- I N
PAC PROFIBUS DP extension module IN
T R A
§
configuration softwareS
I
Can be parameterized from front of device or via Expansion-Module
PAC PROFIBUS DP

§ Simple integration via GSD file


§ Measurement parameters selectable via GSD file
§ Baud rates of 9.6kBit/s up to 12 MBit/s +
§ 9-pole sub-D plug connection in compliance
D I A =

with IEC 61158


- I N
§ I
No external auxiliary power necessary
A N
§
I T R
Status display LED on module Module mounting
Expansion-
Module

§ SDPV1
Protocol: PPROFIBUS
location on
PAC3200
installed

Synchronous and Asynchronous data transmission


including parameter setting.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à perfect communication!
Functions

D I A
Effective communication via RS485 Interface
- I N
PAC RS485 extension module AI
N
T
Can be parameterizedIfrom
Rfront of
§
S software
device or via configuration
Expansion-Module
PAC RS485

§ Supports Modbus RTU and SEAbus


protocol (protocols swichable)
§ Plug and Play +
§ Baud rates of 4,8 / 9,6 / 19,2 and 38,4 kBd
D I A =

§ 6-pole connection via screw terminal


- I N
§
A I N
No external auxiliary power necessary
§
I T R
Status display LED on module Module mounting
Expansion-
Module

S location on
PAC3200
installed

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à high-level technology!
Technical data

D I A
Technical data
- I N
I N
2 quadrant (import) / 4 quadrant (import and export) measurement

A
4Q

ITR
Measurement in single / multi phase systems 1ph, 2ph or 3ph
Suitable for the following systems TN, TT, IT
Sampling
S
Voltage measurement (direct connection up to max. - delta/wye - without VT’s)
Wide range AC/DC pow er supply 7KM2112-0BA00-3AA0
zero blind

690V / 400V
CATIII
Low voltage DC pow er supply 7KM2111-1BA00-3AA0 500V / 289V
CATIII
Current measurement x/1A and x/5A
Auxiliary voltage
Wide range AC/DC pow er supply 7KM2112-0BA00-3AA0

D I A 95-240V AC (±10%)

Low voltage DC pow er supply

- I N
7KM2111-1BA00-3AA0
140-340V DC (±10%)
22-65V DC (±10%)
Dimensions

A I Nl x w in mm
installation depth without module (mm)
96x96
51

ITR
installation depth with module (mm) 73

S
Protection front side IP65
back side IP20
Operating temperature °C -5 … +55
Display type graphics LCD
with backlit
resolution (pixel) 128x96
Language for text outputs multi-language

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à small and slim!
Dimensions

D I A
- I N
A I N
I T R
S

D I A
- I N
A I N
I T R
S
Dimensions in mm

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à easy to connect!
Terminal connections

D I A
-
No.I N Terminal Function

A I N
(1) IL1 k Phase current, Ia, input

I T R (2)
(3)
IL1
IL2
l
k
Phase current, Ia, output
Phase current, Ib, input

S (4)
(5)
IL2
IL3
l
k
Phase current, Ib, output
Phase current, Ic, input
(6) IL3 l Phase current, Ic, output
(7) V1 Phase voltage Va
(8) V2 Phase voltage Vb
(9) V3 Phase voltage Vc
(10)
(11)
VN
L/+

D I A AC:
Neutral conductor Vn
Connection: Conductor (Ph)

- I
(12) N DC: Connection: +
N/- AC: Con.: Neutral conductor (N)

A I N
(13)
DC:
Functional ground
Connection: -

I T R (14) DI - Digital input -

S (15)
(16)
(17)
DI
DO -
DO +
+ Digital input +
Digital output -
Digital output +

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Three-phase measuring, four conductors, unbalanced
load, without voltage transformers, with three current
transformers
- I N
Three-phase measuring, four conductors, unbalanced
load, with voltage transformers, with three current

Connection type 3P4W

A I N transformers
Connection type 3P4W

I T R
S

Three-phase measuring, four conductors, balanced load,


D I A
Three-phase measuring, four conductors, balanced load,
without voltage transformer, with one current
transformer
I N
with voltage transformer, with one current transformer

-
Connection type 3P4WB

A I N Connection type 3P4WB

I T R
S
* Fuses to be provided by the customer.
** Connection for supply voltage

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Three-phase measuring, three conductors, unbalanced
load, without voltage transformers, with three current
I N
Three-phase measuring, three conductors, unbalanced

-
load, with voltage transformers, with three current
transformers
Connection type 3P3W

A I N transformers
Connection type 3P3W

I T R
S

Three-phase measuring, three conductors, unbalanced


load, without voltage transformers, with two current I A
Three-phase measuring, three conductors, unbalanced

D
load, with voltage transformers, with two current
transformers

I N
transformers

-
Connection type 3P3W

A I N Connection type 3P3W

I T R
S
* Fuses to be provided by the customer.
** Connection for supply voltage

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Three-phase measuring, four conductors, unbalanced
load, with voltage transformers, with three current
transformers
- I N
* Fuses to be provided by the customer.
** Connection for supply voltage
Connection type 3P3W

A I N
I T R
S

Three-phase measuring, three conductors, balanced


D I A
Three-phase measuring, three conductors, balanced
load, without voltage transformers, with one current
transformer
I N
load, with voltage transformers, with one current

-
transformer
Connection type 3P3WB

A I N Connection type 3P3WB

I T R
S

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à fits into any network!
Wiring diagrams

D I A
Two-phase measuring, three conductors, unbalanced
load, without voltage transformers, with two current
transformers
- I N
Single-phase measuring, two conductors, without
voltage transformers, with one current transformer

Connection type 3P4W

A I N Connection type 1P2W

I T R
S

* Fuses to be provided by the customer.


** Connection for supply voltage

D I A
- I N
A I N
I T R
S

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à quickly installed!
No-tool installation

D I A
Quick, simple assembly
- I N
I N
§ Fast, no-tool assembly in the control
A
I
combination slot-in mountT R
cabinet door using a sophisticated

S
§ Seal integrated as standard

I A
§ The screws integrated into the combi-
D
- I N
nation slot-in mount can be used to
increase contact pressure and thus

A I N improve the degree of protection to

I T R IP65
S
§ Trouble-free assembly of adjacent devices thanks to easy-to-use combination
mount and low installation depth of just 51 mm (73 mm with extension module)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à easy to connect!
Installation

D I A
Trouble-free, convenient installation
- I N Voltage and

A N
§ Connections for measuring voltage, measuring
current and the auxiliary supply I
current inputs;
auxiliary supply

I
§ Available multi-range powerT R
supply models
§ Wide range AC/DCS power supply:
95...240VAC ±10% / 50/60Hz & 110...340VDC ±10%
§ Low voltage DC power supply: 22…65VDC ±10%
§ Generous provision of screw terminals
throughout the device
§ Conductor cross-sections of 0.5 to 4 mm² D I A
or AWG 20 to 14 connectable
- I N
A I N
§ Connections for digital input, digital output

I T R and functional ground

S § Removable terminal block


§ Conductor cross-sections of
Terminal block 0.2 to 2.5 mm² or AWG 24 to 18
for DI / DO
connectable

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à click and go!
Device configuration

D I A
Configuration via Point-to-Point connection
- I N
N
§ Direct connection between PC and PAC3200
via standard Cross Over Cable AI
I T
§ No special networking skills R
necessary
Sfor SENTRON
§ No administrator rights
Point-to-Point
powerconfig required (except during installation Connection
of the software)

Configuration via Ethernet-Network


D I A
-
§ Communication via switch or Hub within theI N
I N
network; standard patch cable sufficient
A
I T R
§ Easy-to-use search function for the detection of
S
all PAC3200s within a local Ethernet network
§ Establishing a connection to a device and
displaying the connection status in the software Network-
connection
is simple

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à short delivery time!
Ordering information for power monitoring devices

D I A
SENTRON
- I N
Wide range AC/DC power supply; compression terminals
PAC3200
A I N
§ 95…240VAC ±10% / 110…340VDC ±10%
§ x/1A or x/5A
I T R
§ max. 3~ 690/400V; 45...65 Hz
S MLFB: 7KM2112-0BA00-3AA0
SENTRON Low voltage DC power supply; compression terminals
PAC3200 § 22…65VDC ±10%
§ x/1A or x/5A
D I A
§ max. 3~ 500/289V; 45...65 Hz
- I N
MLFB: 7KM2111-1BA00-3AA0

A I N
SENTRON WideR
PAC3200 T
S§§I x/1A
range AC/DC power supply; ring lug terminals
95…240VAC ±10% / 110…340VDC ±10%
or x/5A
§ max. 3~ 690/400V; 45...65 Hz
MLFB: 7KM2112-0BA00-2AA0

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à short delivery time!
Ordering information for expansion modules

D I A
- I N
ExpansionN
V1A
DPR
I module PAC PROFIBUS DP

In
T
S 9,6kBit/s bis 12 MBit/s
n

MLFB: 7KM9300-0AB00-0AA0

D I A
- I N
Expansion module PAC RS485
n
A I N
Modbus RTU / SEAbus (switchable)
4,8R
T
S I
n / 9,6 / 19,2 / 38,4 KBd

MLFB: 7KM9300-0AM00-0AA0

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
IT R
S
Areas of use
Highlights
D I A
Functions
- I N
I N
Technical data
A
ITR
Installations / Assembly

S Configuration
System Integration
Systemintegration
Ordering information
Benefits
SENTRON PAC3200 à saves time and money!
Benefits

D I A
measurement tasks - thus saving storage - N
§ A wide range of functions means that only one device
I acquisition costs.
and
is required for a variety of

A I N
§ Quick, simple assembly saves installation
§ Saves costs and space I asT
R costs.

*) S it can be connected to power distribution systems of up


to 690V without a voltage transformer. No expensive voltage transformer is
required.
§ Comprehensive and precise energy measurement forms the basis for identifying
savings potential in the system.
§ The SENTRON PAC3200's wide variety of measuring and monitoring functions
D I A
I N
contribute indirectly to better protection against failure as faults are recognized
earlier. -
A I N
§ With its technical design, various approvals and certifications, e.g. UL and CSA
I T R
for USA and Canada, as well as the support of 9 languages, the SENTRON
PAC3200 can be used worldwide. S
§ A shallow mounting depth of only 51 mm saves space.
*) 500V max. (Uph-ph) for variants with low voltage DC power supply (7KM2111-1BA00-3AA0)

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


SENTRON PAC3200 à saves time and money!
Benefits

D I A
-
conditions and opens up a wider application
N
§ A large, illuminated graphic display guarantees good
Iarea for the device.
reading even in poor light

A I N
I T R
§ The multilingual, intuitive operation the PAC3200 enables quick initial start-up and

S
easy daily operation, saving both time and money.
§ The network capable Ethernet interface, which comes standard without additional
costs, reduces system integration costs. In addition, the wide bandwidth increases
the system performance significantly.

D I A
§ SENTRON powerconfig, which is free of charge, makes it easier to configure the
devices. This leads to a considerable reduction in time, when multiple PAC3200
have to be setup.
- I N
I N
§ The expansion module PAC PROFIBUS DP or PAC RS485 provides an easy
A
T R
integration in automation or power management systems, e.g. SIMATIC WinCC
I
S
powerrate or SIMATIC PCS 7 powerrate and thereby saves time and
implementation costs.

SENTRON PAC3200 A&D/BD - CD 2008 - Subject to modifications


D I A
- I N
SENTRON
A I N PAC3200
I T R Thank you
S

D I A
- I N
A I N
I T R
S

Você também pode gostar