Escolar Documentos
Profissional Documentos
Cultura Documentos
Contents
5.1.1.6.3.13 MRFUd Technical Specifications
NOTE:
For an MRFUd operating in the 900 MHz frequency band, only the hardware of this module supports the LTE
mode.
In Table 1, * indicates that an MRFUd working in the 1800MHz frequency band supports the 75 MHz IBW when
the PIM interference does not occur.
RF Specifications
Table 2 lists RF specifications of an MRFUd/MRFUd V6/MRFUdw V6.
NOTE:
ATBR in the Transmit and Receive Channels column indicates that this RF module has A transmit channels
and B receive channels.
CxD W in the Output Power column indicates that this RF module is configured with C transmit channels and
the maximum output power of each transmit channel is D W.
EF MSR indicates that E and F data is carried on the same transmit channel of an RF module.
EF non-MSR indicates that E and F data is carried on two different transmit channels of an RF module.
GSM receiver sensitivity is measured, as recommended in 3GPP TS 51.021, in the central band (80% of the full
band) at the antenna connector on condition that the channel rate reaches 13 kbit/s and the bit error rate (BER) is
not higher than 2%.
UMTS receiver sensitivity is measured, as recommended in 3GPP TS 25.104, over the full band at the antenna
connector on condition that the channel rate reaches 12.2 kbit/s and the BER is not higher than 0.001.
LTE FDD receiver sensitivity is measured, as recommended in 3GPP TS 36.104, under a 5 MHz channel
bandwidth based on the FRC A1-3 in Annex A.1 (QPSK, R = 1/3, 25 RBs) standard.
The MRFUd that works in GSM mode and operates in the 900 MHz or 1800 MHz frequency band complies with
the EN 301 502 V9.2.1 standard.
The MRFUd that works in UMTS, LTE FDD, or MSR mode and operates in the 900 or 1800 MHz frequency
band complies with the ETSI EN 301 908 V5.2.1 and 3GPP TS 37.104 standards.
Table 2 RF specifications of an MRFUd/MRFUd V6/MRFUdw V6
MRFUd 2T2R GSM: 8 TRXs GSM: GSM: GSM: The MRFUd See the
UMTS: 900 900 900 supports a MRFUd
maximum sheet in
Without MHz: MHz: MHz: -
3900 Series
-113.7 -116.5 119.2 power
MIMO: 6 Base Station
configuration
carriers 1800 1800 (theoretic Power
al value) of 2x80 W. Consumption
With MHz: MHz: For typical Specifications
MIMO: 4 -114.0 -116.8 1800
power .
carriers UMTS: UMTS: MHz: - configuration
LTE FDD: 2 900 119.5
900 s, see Typical
carriers. The (theoretic Power
MHz: MHz: al value)
bandwidth per Configuration
-125.8 -128.6
carrier is UMTS: for MRFUd.
2100 2100
1.4/3/5/10/15/ MHz: MHz: 900
20 MHz. -126.1 -128.9 MHz: -
131.3
LTE LTE
FDD: FDD: 2100
MHz: -
900 900
131.6
MHz: MHz:
-106.3 -109.1 LTE FDD:
1800 1800 900
MHz: MHz: MHz: -
-106.6 -109.4 111.8
2100 2100 1800
MHz: MHz: MHz: -
-106.6 -109.4 112.1
2100
MHz: -
112.1
MRFUd 2T2R GSM: 8 TRXs GSM: - GSM: - GSM: - The MRFUd See the
V6 LTE FDD: 2 114.0 116.8 119.5 V6/MRFUd MRFUd V6
carriers. The LTE LTE (theoretical w V6 sheet in
bandwidth per FDD: - FDD: - value) supports a 3900 Series
maximum Base Station
carrier is 106.9 109.7 LTE FDD: - Power
1.4/3/5/10/15/ 112.4 power Consumption
20 MHz. configuration
Table 2 RF specifications of an MRFUd/MRFUd V6/MRFUdw V6
of 2x80 W. Specifications
For typical .
power
MRFUd 2T2R GSM: 8 TRXs GSM: - GSM: - GSM: - configuration See the
w V6 LTE FDD: 2 113.7 116.5 119.2 s, see Typical MRFUdw
carriers. The LTE LTE (theoretical Power V6 sheet in
bandwidth per FDD: - FDD: - value) Configuration 3900 Series
for MRFUd Base Station
carrier is 106.6 109.4 LTE FDD: - V6/MRFUdw Power
1.4/3/5/10/15/ 112.1 V6. Consumption
20 MHz. Specifications
.
Engineering Specifications
The following table lists the equipment specifications of an MRFUd/MRFUd V6/MRFUdw V6.
Table 4 lists the surge protection specifications of ports on an MRFUd/MRFUd V6/MRFUdw V6.
NOTE:
Unless otherwise specified, the surge protection specifications depend on the surge waveform of 8/20 μs.
All the surge current items, unless otherwise specified as Maximum discharge current, refer to Nominal
discharge current.
Table 4 Surge protection specifications of ports on an MRFUd/MRFUd V6/MRFUdw V6
The following table lists the surge protection standards of an MRFUd/MRFUd V6/MRFUdw V6.
Item Standard
Surge protection IEC 62305-1 Protection against lightning - Part 1:General principles
IEC 62305-3 Protection against lightning - Part 3:Physical damage
to structures and life hazard
IEC 62305-4 Protection against lightning - Part 4:Electrical and
electronic systems within structures
ITU-T K.35 Bonding configurations and earthing at remote
electronic sites
ITU-T K.56 Protection of radio base stations against lightning
discharges
ITU-T K.97 Lightning protection of distributed base stations
ETSI EN 300 253 Environmental Engineering(EE):Earthing and
bonding configuration inside telecommunications centers
YD 2324-2011 Lightning protection requirements and test methods
for Radio Base Stations (RBSs)
GB/T 50689-2011 Code for design of lightning protection and
earthing engineering for telecommunication bureaus (stations)
Antenna Capability
The following table lists the antenna capability of an MRFUd/MRFUd V6/MRFUdw V6.
NOTE: