Você está na página 1de 1

THIS DRAWING IS THE COPYRIGHT OF DESIGN

A B C D GROUP ENGINEERING CONSULTANTS, AND AS


3100 4900 4000 SUCH, MUST NOT BE RETAINED, COPIED OR
A B C D USED WITHOUT THE CONSULTANT'S
PERMISSION.
01 3100 4900 4000

GENERAL NOTES:
01 1. THIS DRAWING IS THE COPYRIGHT OF
DESIGN GROUP ENGINEERING CONSULTANTS,
AND AS SUCH, MUST NOT BE RETAINED, COPIED OR USED
WITHOUT THE CONSULTANT'S AUTHORITY.
2. DO NOT SCALE FROM THE DRAWINGS.ONLY WRITTEN
DIMENSIONS TO BE FOLLOWED.

3. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN


METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS

* EXISTING BEAM
5700

TO BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

4. ALL DIMENSIONS AND LEVELS INDICATED IN THE

5700

5700
DRAWINGS ARE FROM UNFINISHED SURFACES.

5. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,MECHANICAL
AND ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.
PURLIN LAP 350 350
350 6. DISCREPANCY IN THE DRAWINGS IF ANY,SHALL BE
PURLIN (TYP) PURLIN (TYP) BROUGHT TO THE NOTICE OF THE CONCERNED ENGINEER
SAME AS EXISTING SAME AS EXISTING * EXISTING COLUMN
PRIOR TO THE CONSTRUCTION.
SANDWICH PANEL ROOF SHEET
* EXISTING BEAM SAME AS EXISTING ROOF SHEET
02 EXISTING ROOF SHEET

02
3275

NG

3275
I
AC
F 16

NG
BR

16 CI
O Ø

Ø RA
RO OD

D B
RO OF
R

RO

03

* EXISTING BEAM BELOW


03
FRAME -1

* EXISTING PURLIN
SLOPE 1:15

SLOPE 1:15

SLOPE 1:15
FRAME -2

FRAME -3
* EXISTING STEEL FRAME
2575

OVER RCC COLUMN

SLOPE 1:15

SLOPE 1:15

SLOPE 1:15
* EXISTING BEAM BELOW

2575
E X
G
IN
AC
F 16

NG
BR

16 CI
O Ø

04 Ø RA
RO OD

D B
RO OF
R

RO
04
13500

2300

13500
RIDGE PANEL EXISTING

2300
RIDGE PANEL
SLOPE 1:15

SLOPE 1:15

SLOPE 1:15
05 SAME AS EXISTING

SLOPE 1:15

SLOPE 1:15

SLOPE 1:15
05
G
IN
AC
F 16

NG
BR

16 CI
O Ø

Ø RA
RO OD

D B
RO OF
R

RO
E X
5350

5350
G
IN
AC
F 16

NG
BR

16 CI
O Ø

Ø RA
RO OD

D B
RO OF
R

RO

* EXISTING RCC BEAM


06
* EXISTING BEAM
CONCEPT DESIGN
* EXISTING COLUMN
06
C02 24/05/2018 REVISED AS PER SITE DRK
PROPOSED BUILDING
C01 05/02/2018 FOR APPROVAL DRK

ROOFSHEETING PLAN REV. DATE ISSUE OR REVISION APPR


PROPOSED BUILDING CLIENT:

ROOF FRAMING PLAN M/S. SPECIAL TECHNICAL SERVICES


* EXISTING TIE BEAM AND COLUMNS

SCHEDULE OF STEEL FRAMES


CONSULTANT:
Design Group Engineering Consultants LLC
TYPE DESCRIPTION Muscat (Oman) + Bangalore (India)
350(OVER LAP) 350(OVER LAP) P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
FRAME-1 EXISTING STEEL FRAME AT GRID C TO BE SHIFTED TO GRID A Tel: +968-2481 9477 l Fax: +968-2481 9487 l GSM: +968 9986 8277
120 Email: info@dgcon.com l website:www.dgcon.com.
70
FRAME 2 STEEL FRAME SAME AS EXISTING FRAME AT GRID D TO BE INTRODUCED
PROJECT TITLE:

FRAME 3 EXISTING STEEL FRAME AT GRID C TO BE SHIFTED TO GRID A 150 (LAP) 50 100 100 50
MODIFICATION OF
AND A NEW STEEL FRAME SAME AS EXISTING FRAME AT GRID D TO BE MOUNTED
EXISTING DINING FACILITY
100
190
AT GHALA

previously DRAWING TITLE:

approved sheet STRUCTURAL STEEL DETAILS


DRAWN : DESIGN : CHKD : APPR : DATE :
SUJ GPE GPE DRK 05/02/2018
TYPICAL ROOF PANEL LAP DETAIL TYP. BRACING ROD FIXING DETAIL TYP. FLANGE BRACING DETAILS.
JOB NUMBER : SCALE : SHEET : PLOT NO :
TYP. LAPPED PURLIN FIXING DEATILS.
TYP. RIDGE DETAIL BD1780816 1:50 A1 -
DRAWING NO. REV. NO :
80816-SS-FRM-01-02-3001 C02