Você está na página 1de 2

PRODUCT DATA SHEET

Bentley Hevacomp Mechanical Designer V8i


Building Systems Mechanical Design Software Suite

Bentley Hevacomp Mechanical Designer V8i is a design software suite for all consultant and
design contractor professionals working with building mechanical systems.

Systems Design Acoustics programs are provided for noise in ductwork


Bentley Hevacomp Mechanical Designer V8i is used by systems, plant room noise levels, noise nuisance to
building services engineers, HVAC professionals and other adjacent buildings and audibility of fire alarms.
MEP professionals who want a quick and easy tool for
making engineering quality building load and energy Load Calculations
calculations. Duct and pipe system sizing can be carried Load calculations such as heat loss, radiator sizing, heat
Shadow Analysis
out along with fan and pump sizing and selection. This gains (CIBSE, Carrier and ASHRAE), shadow analysis,
software uses a straightforward, robust calculation heating and air conditioning energy, summer overheating,
methodology to provide quality analysis, making it Building Regulations and psychrometric analysis can be
indispensable in a mechanical designer’s software toolkit. carried out.

Pipe and Duct Sizing


Systems can be sketched out schematically on-screen, Bends and tees are automatically
forming the data input for pipe and duct sizing in Bentley
implied from the layout and default
Hevacomp. This powerful graphical interface provides a simple
and intuitive input method, which enables systems to be fitting types can be used, making
Cad Input-Select Glazing
defined faster and with less error. Systems can be sketched global changes very simple.
in plan or as an isometric. A DXF CAD drawing can be
imported to act as a template for the system. Simple building
Room data can be set up automatically from an
elements can also be drawn as required. Pipe and duct systems
imported DXF CAD drawing or directly entered. Room
are drawn to scale, using a snap grid. Bends and tees are
automatically implied from the layout and default fitting selection for load calculations is either graphical from
types can be used, making global changes very simple. the drawing or by direct selection. Extensive databases
of materials and weather data are available and
Results from Bentley Hevacomp’s pipe and duct sizing construction elements can be analysed to check for
programs can be produced to the screen, a printer, or as condensation and admittance.
a database or spreadsheet file. Reports of sizes, pressure
drops, balancing pressures, quantities schedules and total A powerful Hot Key feature enables you to change room or
3D-Building View weight are produced. System drawings can be exported as building data while simultaneously viewing the effect of
DXF files to AutoCAD and other CAD packages. these changes in your design results and graphics.

Bentley Hevacomp pipe and duct sizing programs are The extensive range of Bentley Hevacomp Mechanical
available for single pipe, two pipe heating and cooling and Designer also includes programs for U values, chimney
reversed return systems, gas and steam systems, hot and sizing, infiltration, insulation economics, solar panel
cold water services, above and below ground drainage. analysis, discounted cash flow, lifecycle costing, CPA
analysis and NEDO calculations.
Ductwork programs are supplemented with programs for
grille sizing using a database of manufacturers’ grille data, The lighting design software ini Bentley Hevacomp is
pitot/anemometer reading analysis and smoke control integrated with the mechanical software, enabling the use
calculations to BS 5588. of a common project database for design work.
Weather Map
SYSTEM REQUIREMENTS Bentley Hevacomp Mechanical Designer V8i
Processor:
P3 @1GHz At-A-Glance
Memory: Design Database Construction Properties Duct and Pipe Sizing
1GB • Easy-to-use everyday tool • Delivered with a comprehensive • All sections sized so index
Graphics: • Simple input, short learning curve material list as well as a built in run is identified
On board SVGA • As all sections are sized
module for calculating thermal
CAD-export to DXF balance pressures and schedules
O/S: properties can be produced
• Buildings can quickly and easily
Win 2000 or XP pro be defined • Quick building definition using
standard constructions or
Fan and Pump Sizing
USB: • Easy-to-use building modeler • Fan and pump duties are calculated
Yes utilizing a DXF file user-defined constructions from
• As all sections size accurate fan and
CD-ROM: base materials pump duties can be calculated
3D Model
Yes Shadow Analysis
• 3D visualization tools with rotate Pump Selection
and zoom functionality • All structures can be defined • Pump database is provided.
• Visual identification of input errors around design building • Pumps can be selected directly from
• Beneficial shading and corresponding the pump database without having to
Find out about Bentley Heating and cooling Load search multiple catalogues
Calculations cooling load calculations can
at: www.bentley.com be assessed Schedules
• One common model for all
Contact Bentley load calculations • Schedules are automatically
1-800-BENTLEY (1-800-236-8539) External Shading From produced
• Reduction in input time by running
Outside the US +1 610-458-5000 calculations from a common model Fins/Louvers • Components can easily be reported
• Predefined and user defined fins/ as all sections are sized
Global Office Listings Heating and Cooling
www.bentley.com/contact louvers can be added to windows Control Valve Selection
Load Calculations • Fin/louver designs can be assessed • Control valves can be selected
• Localized calculation modules directly from the provided control
when considering cooling loads
• Able to calculate with the valve database without having to
appropriate method Duct and Pipe Sizing search multiple catalogues
Energy Calculations • Graphical interface for easy definition
Addition of Notes
• Compare of efficient building • Significant reduction in time • Notes are added to drawings
design options and improved accuracy over automatically
• More efficient building designs manual calculations • Simple drawing being created
with lower carbon footprint
Simple 2 ½ D input Single Line Schematic Drawing
Summer Overheating • Systems are laid out in x,y,z • Graphical input method is
• Assess summer design conditions also generating a simple
plane and between floors
with no cooling schematic drawing
• Quick way to define systems • Simple drawing being created
• Assess simple passive design
and easily refine design
solutions quickly DXF Output
Code Checking Comprehensive List of • DXF output allows schematic
System Types drawing to be exported to most
• Data from common model can
• System types include heating, CAD systems
be compared to country specific
building codes chilled water, ductwork, gas,
• Easy and quick comparison with local Hot water and cold water services
codes ensuring building is compliant • Most system types are supported

Design Simulation Results Duct Sizing

© 2010 Bentley Systems, Incorporated. Bentley, the “B” Bentley logo, and Hevacomp are either registered or unregistered trademarks or service marks of Bentley Systems,
Incorporated or one of its direct or indirect wholly owned subsidiaries. Other brands and product names are trademarks of their respective owners. DAA037920-1/0002 11/10

Você também pode gostar