Path Finders
Sudo
Wall recessed
Sudo represents a perfect combination of sleek aesthetic fixture
designed for optimum illumination performance. The luminaires have
high quality LED source with low energy consumption and long
service life. Designed for low mounting heights for illumination where
guidance and security lighting is required. The small scale of these
luminaires makes them especially suitable for installation in step risers
for both interior and exterior applications.

IP65

ny
pa
om
C
g
t in
gh
Li
s
a'
di
In
T E
LI

Jado
K-

Wall recessed
Sudo - Path Finders

Sudo represents a perfect combination of sleek aesthetic fixture


designed for optimum illumination performance. The luminaires
have high quality LED source with low energy consumption and
long service life. Designed for low mounting heights for
illumination where guidance and security lighting is required.

The small scale of these luminaires makes them especially suitable


for installation in step risers for both interior and exterior
applications.

Technical Specifications
• Luminaire made of pressure die cast aluminium alloy with non
corrosive SS fasteners.
• Non yellowing UV stabilized translucent polycarbonate / acrylic

ny
diffuser.
• Silicon gasket.

pa
• Industrial plastic Installation housing for preparing the recess

om
opening in the wall / stairs.
• Cable entries for through-wiring of mains supply cable.

C
• Integral power supply.
• Earth connection.
g
• Safety class I.
in
• Protection class IP65.
t
gh

• - Conformity mark.
• Suitable for operation on 240V, 50Hz single phase ac supply.
Li

• Ordering guide : KL-2754-CCT ( Colour Temperature ).


s

• Available CCT WW : Warm White (2700K), CW : Cool White


a'

(5700K), NW : Neutral White (4000K).


di

Product Benefits
In

• High luminous efficiency at reduced wattage.


E

• A sleek and minimalist shape provides distinctive lighting effects


T

for walkway architecture.


LI

• Sustainable LED technology offers durability and optimal light


K-

output with low power consumption.

Area of Application
Staircase, Patios, Pathways, Passages, Porches, Entrance & Exits for
both Interiors & Exteriors applications.

The luminous flux and the connected wattage quoted might change as a result of technical progress. For the latest technical
information, Installation guidelines and product updates with LED service life please refer to the website at www.klite.in

Important Note : To ensure proper installation, kindly translate / communicate the installation instructions to a
qualified electrician in their respective local language.
ny
pa
om
C
g
t in
gh

Sudo Mini / Sudo - Open Frame


Li

ID Wattage A B C Cutout(mm)
s

2754 3W LED 130 76 90 126 x 71 x 83


a'

2745 6W LED 130 76 90 126 x 71 x 83


di

2753 6W LED 255 76 90 242 x 71 x 83


2741 12W LED 255 76 90 242 x 71 x 83
In
TE

A C
LI

B
K-

Photometric
105° 105° 105° 105°

90° 90° 90° 90°

75° 75° 75° 75°


40
60° 60° 60° 60°
60
80
80
45° 45° 45° 45°
120 100

120

140
30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd/klm cd/klm
C0 - C180 C90 - C270 ID : 2741 C0 - C180 C90 - C270 ID : 2745

4
ny
pa
om
C
g
t in
gh

Sudo Mini / Sudo - Grid Frame


Li

ID Wattage A B C Cutout(mm)
s

2756 3W LED 130 76 90 126 x 71 x 83


a'

2746 6W LED 130 76 90 126 x 71 x 83


di

2755 6W LED 255 76 90 242 x 71 x 83


2742 12W LED 255 76 90 242 x 71 x 83
In
TE

A C
LI

B
K-

Photometric
105° 105° 105° 105°

90° 90° 90° 90°

75° 75° 75° 75°

60° 60° 60° 60°


32
60
45° 45° 45° 45°
48
80

64
100

30° 15° 0° 15° 30° 30° 15° 0° 15° 30°


cd/klm cd/klm
C0 - C180 C90 - C270 ID : 2742 C0 - C180 C90 - C270 ID : 2746

5
ny
pa
om
C
g
t in
gh

Sudo Mini / Sudo - Asy Frame


Li

ID Wattage A B C Cutout(mm)
s

2758 3W LED 130 76 90 126 x 71 x 83


a'

2747 6W LED 130 76 90 126 x 71 x 83


di

2757 6W LED 255 76 90 242 x 71 x 83


2743 12W LED 255 76 90 242 x 71 x 83
In
E

A C
T
LI

B
K-

Photometric
105° 105° 105° 105°

90° 90° 90° 90°

75° 75° 75° 75°

60° 60° 60° 60°


80 80

45° 45° 45° 45°


120 120

160 160

30° 15° 0° 15° 30° 30° 15° 0° 15° 30°


cd/klm cd/klm
C0 - C180 C90 - C270 ID : 2743 C0 - C180 C90 - C270 ID : 2747

6
ny
pa
om
C
g
t in
gh

Sudo Mini / Sudo - Asy Reeded Vertical Frame


Li

ID Wattage A B C Cutout(mm)
2750 3W LED 76 130 90 71 x 126 x 83
s
a'

2760 6W LED 76 255 90 71 x 242 x 83


2763 6W LED 76 255 90 71 x 242 x 83
di

Sudo Mini - Asy Vertical Frame


In

2749 3W LED 76 130 90 71 x 126 x 83


T E

A C
LI
K-

2760 / 2763

A C

2750 2749

7
ny
pa
om
C
g
t in
gh

Sudo Mini - Slot Open Frame


ID Wattage A B C Cutout(mm)
Li

2761 3W LED 76 130 90 71 x 126 x 83


s

Sudo Mini - Focus Frame


a'

2762 3W LED 76 130 110 71 x 126 x 83


di

Sudo Mini - Beam


In

2759 3W LED 76 130 90 71 x 126 x 83


T E
LI
K-

A C

2761 2759
C

2762

8
ny
pa
om
C
g
t in
gh
Li
s
a'
di
In
T E

Jado
LI
K-

ID Wattage A B C Cutout(mm)
2735 12W LED 244 96 191 235 x 85 x 182
2625 18W CFLC 244 96 191 235 x 85 x 182

A B

9
Path Finders
Installation, Use and Maintenance Guidelines
(Indicative for all luminaires in this series)

Application
Wall mounted luminaire with shielded light source, Designed for low mounting heights for the illumination of interior
and exterior locations where guidance and security lighting is required. Various lamping options including LED offers
durability and optimal light output with low power consumption.

ny
pa
om
C
g
in
Note : Technical amendments reserved
t
gh

Light Source : LED / CFL. Varied wattage Options


Li

Normal rated voltage for luminaire is 220-240V, 50Hz, single phase ac supply.
s
a'
di

Installation Recommendation
In

• This product is suitable for Indoor & Outdoor application.


• The main material of this product is aluminium, Surface coatings is suitable only for natural environment. Don’t install
E

this product near sea water or in the environment which is high in salt or acid content.
T

• Electronic equipment is sensitive to voltage surges. Hence it is recommended to install a stabilizer at source to ensure
LI

constant voltage power supply to all outdoor luminaires, for better performance and life span of the luminaire and to
K-

avoid risk of damage.


• Installation and maintenance of the luminaire should be carried out by qualified person only in accordance with good
electrical practice and appropriate accessories.
• The IP rating of the connector between fixture and main cable must be equal to or greater than the IP rating of the
Luminaire.
• It is very important to follow these instructions to enable the luminaire to be installed correctly. Failure to follow this
will void all warranty on the product.
• Please retain installation guidelines for future reference.

Technical Specifications
• Luminaire made of die cast aluminium alloy and non corrosive stainless steel 304 grade fasteners.
• Non yellowing UV stabilized clear / translucent diffuser
• Silicon gasket
• Industrial plastic Installation housing for preparing the recess opening in the wall / stairs.
• Mounting plate with 2/4 fixing holes for mounting on recessed plastic housing.
• Cable entries for through-wiring of mains supply cable
• Earth connection
• Safety class I
• Protection class IP 65
• CE - Conformity mark
• Finished with pure polyester powder coated graphite grey

Light distribution
Luminaire photometric data / IES files for the light planning program DIALux can be downloaded in IES-format on the
KLITE web page www.klite.in.

Safety
• For Safety, always ensure power supply is disconnected before regular maintenance, lamp replacement and accessory
fitting.

ny
• Installation and operation of this luminaire are subject to national safety regulations. The manufacturer is discharged
from liability when damage is caused by improper use or installation.

pa
• Any modification to this fixture without authorizaton will void all warranty and the persons responsible for the
modification shall be considered as manufacturer.

om
• Observe precautions for handling LED module.
• Do not subject the product for voltage or current which is not rated for.
• Do not use lamps with higher wattage than indicated.
C
g
• Luminaire not suitable for direct mounting on normally flammable surfaces
t in
gh

Installation
Li

The luminaire must be operated with the complete protective cover.


• The luminaire must not permanently get in contact with aggressive media that might corrode the housing of the
s

luminaire.
a'

• The recessed opening is covered by the frame of the luminaire housing.


di

• Dismantle luminaire from the recess plastic housing.


In

• Position recess plastic housing into the solid wall and fix it using suitable fixing material.
E

• Do not open the front plate of light output opening of LED directly during installation.
T

• Use only flexible supply cables of suitable rating and diameter. Do not use hard cables or armoured cables (Hard cable
LI

could effect the IP rating of the product).


• Do not enter the single wires into the power point connector.
K-

• Please ensure that the wires are connected to the right polarity [Phase, Neutral & Earth] and the luminaire must be
earthed ( Class 1).
• Insert luminaire into the plastic housing and fix with non-corrosive stainless steel screws.
• Lock and unlock the screws following an alternative sequence, tightening all screws evenly.

Important Note
• LEDs are highly sensitive electronic components. Please avoid touching the light source directly, during installation.
• If fixture is supplied with integrated LED module, Do Not Open the front plate of luminaire during installation.
Warranty void if the LED compartment is opened
Cleaning and care
• After installation, the luminaire should first be cleaned.
• Building dust, residues from pressure-sensitive adhesives, paint splatter and rust film must be completely removed.
Never use cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous
rust to form.
• Cleaning agents containing hydrochloric acid and chlorides should never be used.
• We recommend cleaning the luminaires regularly.
• Do not use high pressure cleaners

Maintenance Recommendations
A scheduled maintenance program must be carried out on the Installation and fixtures regardless of the IP rating or
application
• Disconnect the electrical supply before maintenance operation
• Open the luminaire. Remove the lamp
• Check the gasket, diffuser, seals are in good condition and replace, if necessary.

ny
• Check that the screws are not loose on various components and that the cable gland is securely tight
• Ensure the luminaire is properly closed and clamped back into position after regular maintenance of lamp or control

pa
gear in order to maintain the IP rating of the fixture.

om
Note For LED Version: The LED module contained in this luminaire shall only be replaced as per the manufacturer

C
recommendation. For futher informations, please contact your supplier.
g
Storage
t in
If site is not ready for installation, store the material in proper warehouse facilities. K-Lite is not responsible for the
gh

damages caused due to the mishandling of material at site.


Li

Important Note
s
a'

To ensure proper installation, kindly translate / communicate the installation instructions to the local qualified electrician
di

in their respective local language.


In

Please Recycle
T E

The electronic components of this product should not be disposed via the normal waste system. To prevent possible
LI

harm to the environment and Human health please ensure that the product is recycled in an environmentally sound
manner. Please contact your local collection facilities for more details
K-

Customer Service
If Klite agrees to receive back some fixtures for Lab Testing and further analysis please ensure that the fixtures shipped
should NOT BE DISASSEMBLED. Disconnect the power line and ship the product as is unless otherwise specified.
Please contact customercare@klite.in for more information.
Path Finders Installation Guidelines

Front View

Recessed housing

Remove
2 Screws
Always ensure that
the Juction box is
below the luminaire
during Installation
• The recessed opening is covered by

ny
the frame of the luminaire housing. Position recess plastic housing into
• Dismantle luminaire from the recess the solid wall and fix it using suitable

pa
plastic housing. fixing material.

om
Side View

Approprirate IP65
C
g
Rated Connector
in
Tighten Screws
t
gh
Li
s
a'
di
In

Always ensure that the


Juction box is below
E

the luminaire
T
LI

Please ensure that the wires are connected to the right polarity [Phase, Neutral & Earth]
and the luminaire must be earthed ( Class 1).
K-

Insert luminaire into the


plastic housing and fix with
non-corrosive stainless
steel screws
How to Install your outdoor luminaire correctly with connectors
Water infiltration is one of the biggest reasons of damage to outdoors fixtures . The main reason being no proper
water proof connectors being used during installation.

Water moisture Water moisture


Exposed open Air Underground

Why use the water - proof connector ?


When the fixture is turned on, the inside temperature will increase as the operating time goes. Conversely when the

ny
lamp stops working, the temperature will drop slowly. This phenomenon will cause “The siphon effect”. Thermal
expansion and contraction makes the inside and outside air pressure different. The air which includes water vapour

pa
will infiltrate to the housing through the wire entry as soon as the internal air pressure is lesser than the external

om
pressure. The infiltration is caused by several incorrect connections like the picture below. This water vapour will
then become droplets of water that will be seen inside the fixture.

C
Incorrect Installation g
t in
gh
Li
s
a'
di

When the wire is connected into the fixture through cable gland, the cable must be more than 10mm inside.
In

Please refer to the images below.


T E
LI
K-

The best and easiest ways to prevent the water filtration are by IP rated connectors
We recommend using the water-proof connectors as shown below for all outdoor fixtures. Installers should prepare
the appropriate main cables of suitable rating and diameter with the right IP rated connectors.

One input & two output


K-
LI
T E
In
di
a'
s
Li
gh
tin
g
C
om
pa
ny
ny
pa
om
C
g
t in
gh
Li
s
a'
di
In
ET
LI
K-

K-LITE INDUSTRIES
India’s Lighting Company
D-10, Ambattur Industrial Estate, Chennai - 600 058
Tel : 26257710, 48581950. Fax : 26257866
Cell : 95000 79797, 95000 85511.
Email : info@klite.in Website : www.klite.in
Unit II
23B, SIDCO Industrial Estate, Chennai - 600 098.
Unit III
179 & 180, SIDCO Industrial Estate, Chennai - 600 098.
FACTORY Display Centres
• G6 & G8, Ambattur Industrial Estate, Chennai - 600 058
Delhi
• 928, Shop No. 2, Khasra No. 402, Main MG Road, Ghitorni,
New Delhi - 110 030. (Opposite Metro Pillar 118)

Você também pode gostar