with 4-20 mA Position Transmitter Pub # 105083revB

QUARTZ® (QZP5O___, QZE5O___, QZP7O___, QZE7O___)

SERIES Installation & Adjusting Instructions


Thru-Bolt™ Mounting
8a

1. Attach mounting plate to actuator using fasteners 8

and lockwashers provided.


5
2
2. Loosen indicator cover set-screw.
2a. Rotate indicator cover to desired viewing angle and 2a N AM U R TYPE
retighten set-screw. (Make sure indicator cover is
pushed all the way into housing slot.)
4

3. Rotate coupling spacer and indicator drum to 4a

desired position. (OPEN or CLOSED appearing 3


through indicator window)
5a 1
3 4
6
4. Remove spacer screw and fit torque coupling or 4a
5b

Namur coupling onto coupling spacer. Separate 6

spacer and indicator drum and rotate spacer to align


coupling with actuator shaft. Fit coupling spacer
over indicator drum drive hub.
4a. Secure torque coupling assembly or Namur coupling
with screw of proper length. (Additional coupling
spacers and longer screw may be required on some
mountings.)

5. Slide Thru-Bolts with washers into housing and fit CAUTION:


retaining quad-rings over bolts to retain them. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERES,
5a. Top of actuator shaft should be within 1/4"
REPLACE COVER BEFORE ENERGIZING THE ELECTRI-
(6.35mm) from coupling screw head or Namur
coupler.
CAL CIRCUITS.
5b. Torque coupler or Namur coupler must be fully
engaged in slot and be centered on the shaft or KEEP COVER TIGHTLY CLOSED WHEN IN OPERATION.
block attached to the shaft.

6. Operate actuator to full open and full closed


positions and check for proper alignment between
switch and actuator. Eccentricity of shaft must
be no greater than .01" (.254mm) from
centerline. The torque coupler or Namur coupler
must be centered on the flats of the actuator shaft or
block in both the full open and full closed position.
Realign as necessary and final tighten Thru-Bolts.
StoneL Corporation
7. "Fine-tune" visual indicator cover repeating #2 and One StoneL Dr
lightly tighten set screw. 26275 US Hwy 59
Fergus Falls, MN 56537
USA

Telephone: 218.739.5774
Toll Free: 800.843.7866
Fax: 218.739.5776
Approval Agency Controlled Document. © 2002 StoneL Corporation E-mail: sales@stonel.com
No Changes Authorized Without Prior Agency Approval Website: www.stonel.com
Pub # 105083revB
QUARTZ with Position Transmitter Page 2
Specifications: (QZP5O__, QZE5O__, QZP7O__, QZE7O)
Output: 4-20 mA Span: Adjustable from 35° to 270°
Voltage Range: 10 to 40 VDC Max Linearity Error: Standard Potentiometer + 0.85°
Recommended Voltage: 24 VDC, 50 mA Minimum High Perf. Potentiometer + 0.35°
Max Load: 700 ohm @ 24VDC (See Load Curve) Temperature Range: -40° to 80° C
Warranty: 2 Years

1600
Load Curve
Electrical Schematic
1400
1200
- + -
1000
Loop 0 to 100% ammeter or analog
Resistance 800 computer input
600
+
400 position transmitter + -
Operatingı
Region
200
voltage supply 24 VDC
5 10 15 20 25 30 35 40
PowerSupplyVoltage

Position Transmitter Calibration


1. Connect the plug as shown for either clockwise or counter
clockwise to open operation (as viewed from top).
2.

4
2. Operate actuator to desired "zero" position. With power

Spares
3
disconnected, connect an ohm meter across the terminals located White

2
on top of the potentiometer. For counter clockwise rotation,
4.

Black
connect to the terminals with the black lead and white lead. For

1
Red

Trans.
clockwise rotation, connect the ohm meter to the terminals with the

-
red lead and and white lead.

+
3. Loosen bottom set screw and rotate coupling until the ohm meter
reads between 400 - 600 ohms. Retighten set screw, verify the
ohm meter still reads between 400 - 600 ohms.
4. Disconnect the ohm meter and connect DC power to the positive
(+) and negative (-) terminals (see electrical schematic).
5. Adjust the screw on the zero trimpot for a 4mA output
6. Operate actuator to the desired "100%" position.
7. Adjust the screw on the span trimpot for a 20mA output. Zero and
Span adjustments are non interactive. 3.
Wiring Diagram
Trans +

Trans -

Spare 1 Transmitter
NOTE 1.
7.
Spare 2
5. Plug Must Be at One End
of Connector or the Other

2 Pins Visible 2 Pins Visible


Spare 3 Z S Z S
E P E P
R A R A
O N O N

Spare 4
Clockwise to Open
Counter Clockwise to Open
Operation
Operation

StoneL Corporation Phone: (218) 739-5774 · Toll-free: (800) 843-7866 · Website: www.stonel.com