CONCRETE
DENSIFICATION
TECHNOLOGY
DENSIFY
Application of the Ashford Formula is a Permanent life cycle - no need for Zero (0) VOCs
Single, permanent application - no
Over time, Ashford Formula treated replacement like floor coverings
one-time, permanent application. This need for expensive re-application
floors develop a wax-like sheen. As
eliminates the need for expensive materials, labor or costly facility CE Declaration of Conformity
a floor is subjected to traffic and
re-application materials, labor costs downtime
regular cleaning, the machine-troweled Produces no fumes, vapors, off-gassing;
and facility downtime. Routine surface
concrete self-polishes, instead of VOC free - improves indoor air quality
cleaning is all that is required for long- REACH Certified
eroding or wearing away.
PERMANENT E L I M I N AT E S H I G H term maintenance. Quick application - saves valuable
SHEEN MAINTENANC E C OSTS Contributes to LEED points for
construction time and cost NFSI Certified “High-Traction”
sustainable building; HPD available
A simple scratch test with a metal This non-densified concrete Scratching a concrete surface Ashford Formula densifies by
J. Keith McCoy, Chief of Maintenance, Pennzoil Company
object demonstrates the softness of sample reveals the porous densified with Ashford Formula penetrating the concrete surface and
PENNZOIL EXECUTIVE HANGAR
non-densified concrete. structure of concrete, which leads reveals no erosion or dusting. filling the natural pores and voids HOUSTON, TX, USA
to wear and deterioration. Ashford Formula has strengthened with crystalline growth. 1980
the concrete surface from within.
1 3 4
REAL PROJECT HIGHLIGHTS
INDUSTRIES SERVED
1 Inland Port 15 Warehouse 2 Ozeaneum Museum 3 Ajans Medya Office
by Admire Concrete - USA by NORSA GmbH - GERMANY by ERA Ltd. - TURKEY > Correctional Facilities > Exhibit Halls > Parking Decks / Garages > Warehouses
4 Parking Garage 5 Metro Cash and Carry 6 Daechun Harbor > Data Centers > Manufacturing Plants > Retail Stores
by Wuxi Hua Can Chemical - CHINA by Gia Phu Dinh Construction - VIETNAM by ILDO Trading Co. Ltd. - SOUTH KOREA
> Distribution Centers > Outdoor Concrete > Stadiums / Sports Arenas
7 Melbourne Market Relocation 8 Fairfax County Maintenance Repair Garage
Note: This is not a comprehensive list. Ashford Formula and Curecrete’s line of supporting products can be used on most any concrete floor serving a multitude of industries and functions.
by Green Concrete Products - AUSTRALIA by Mid-Atlantic Coatings, Inc. - USA
5 6 7
With its one-time application, the Ashford Formula never requires
re-treatment. It provides exceptional performance for the entire life
of your floor. Never halt your business productivity or pay for costly
repeated applications down the road. It’s why notable worldwide
Your concrete floor is more than a building foundation. It is also the corporations have chosen the performance of the Ashford Formula.
foundation of your business productivity. For lifelong floor performance,
long-term cost effectiveness and sustainability, worldwide corporations With the longest proven track record of performance in the industry,
like Caterpillar, CocaCola, DHL, Procter & Gamble, IKEA and Whirlpool 65+ years and counting, Ashford Formula is the trusted product for
A SOLID FOUNDATION, FROM THE GROUND UP have chosen Ashford Formula as their concrete densifier of choice. permanent, superior concrete floor results.
Your business productivity requires a solid, DENSIFIED concrete floor.
PERFORMANCE CRITERIA
PRODUCT INFO
UN
ASTM D 3359 -
on
0.7 0.7
TRE
0.7
HF
0.7
Surface Adhesion
reased Abrasi
O RD
ATED SAM
+32.5% 0.6 0.6 0.6 0.6
F OR M
Adhesion of Coatings:
For epoxy, a 22% increase
Inc
0.5 0.5 0.5 0.5
U
in adhesion over untreated
LA
PL
ar
We
E
Less 0.4 0.4 0.4 0.4 samples. No change in
adhesion for polyurethane.
DESCRIPTION SURFACE PREPARATION EQUIPMENT CLEAN-UP 0.3 0.3 0.3 0.3
Clear, odorless, non-toxic, non-combustible, • Freshly Finished Concrete (NEW): Use soap and water before the Ashford
non-flammable. Contains no VOCs. No preparation required. Formula dries. 0.2 0.2 0.2 0.2
INCREASED
• Existing Concrete (OLD): PERMEABILITY
USES PAINTING ABRASION RESISTANCE 0.1 0.1 0.1 0.1
Sweep, scrub or strip concrete to
Concrete, heavyweight concrete block, Allow at least seven (7) drying days before
remove any surface contaminants
exposed aggregate and other sand/aggregate applying paint on existing concrete. Seepage Rate
or film. ASTM C 779 - Depth of Wear REF
AF
REF
AF
portland cement combinations. TILE TILE
Allow twenty-eight (28) days for proper curing
APPLICATION Using a 7 ft. (2.13 m) head
New or old concrete, rough or smooth surfaces. before painting new concrete. Abrasion Resistance to Revolving Disks: WET DRY of water on a 4.91 in2
Only one permanent application is required. An improvement of 32.5% over untreated
NOTES (124.71 mm2) area treated
Apply with high-volume, low-pressure sprayer samples after 30 minutes.
FUNCTIONS until flood coat is achieved. Work material with Ashford Formula only
Apply to colored concrete only after the slab
Densifies, dustproofs, hardens and cures. into the surface with fine-bristled brooms, is fully cured, unless installed by a factory
HIGHER FRICTION allowed a rate of 0.00073
Protects against dusting, pitting, spalling, or with an auto scrubber. Keep the entire certified applicator. oz (0.022 cc) / hour. After
efflorescence and surface crazing. Inhibits surface wet with Ashford Formula for 30 several days the sample
freeze/thaw deterioration. minutes. Then when the Ashford Formula Do not allow to dry on finished surfaces became damp, but no
becomes slippery, flush completely with water (glass, aluminum, stainless steel, walls, etc.) as 9 9 9 ASTM C 1028 - Friction
and squeegee dry or vacuum excess with an observable local seepage.
permanent etching may occur.
PACKAGING automatic scrubber. 8 8 8 The co-efficient of friction on steel-troweled samples:
• 55 - gallon drums / 208 liters The Ashford Formula may not prevent reference tile vs. Ashford Formula
*See Spec Data Sheet or Application deterioration of floor slabs on which salts from 7 7
• 5 - gallon pails / 19 liters Specifications for specific details.
7 (a higher ratio represents a less slippery surface):
ice melt are allowed to accumulate, especially WEATHERING
when the floor is exposed to frequent wet/dry Wet - 0.69 vs. 0.47 // Dry - 0.86 vs. 0.71
6 6
STORAGE LIFE DRYING TIME cycles.
6
ASTM G 23 - Light
Indefinite. Agitate before use. One (1) to three (3) hours. The surface may 5 5 5
Although the Ashford Formula provides a Exposure Degradation
be used as soon as the application is complete
dense concrete surface, it cannot in all cases
and the surface is dry to the touch. Newly
COVERAGE prevent the migration of moisture vapor from 4 4 4
placed concrete requires the normal hardening Exposure to ultraviolet light
beneath a floor slab. In conditions of high
period. and water: No evidence
Approximately 200 ft2/gal (5 m2/L). vapor drive, salts and other inorganics may 3 3 3
still be deposited on concrete floor surfaces of adverse effects on the
Coverage may depend on the temperature and SURFACE APPEARANCE treated with the Ashford Formula, especially UN
samples treated with
AS
2 2 2
porosity of the concrete.
HF
when no vapor barrier has been installed
TR
On smooth troweled concrete, a sheen Ashford Formula.
ORD FORMU
E
beneath the slab.
ATED SAM
+13.3%
develops within 4-12 months. All other 1 1 1
TEMPERATURE LIMITS surfaces retain their natural appearance. The
Ashford Formula is a highly effective
sheen can be accelerated by burnishing the
Apply in temperatures up to 115°F (46°C) or as floor. A spiff coat can also be used to enhance compound which delivers superior results.
P
LE
LA
low as 35°F (1.7°C) and protect from freezing the initial sheen. Application should be performed by qualified AF H 2O C3O9 This technical information
for a period of six (6) days. contractors with a clear understanding of its is provided as a general
application and uses. *See Spec Data Sheet performance profile for
or Application Specifications for specific evaluating the appropriate
details. use of Ashford Formula.
ENHANCED CURING Independent laboratories
QUICK LINKS GREATER obtained the test
IMPACT RESISTANCE performance results under
ASTM C 856 - Petrographic Examination controlled environments.
APPLICATION HPD MANU (Density of the Paste) Curecrete Distribution,
SAFETY SPEC
SPEC DATA Inc. makes no claim that
SPECS DATA ASTM C 805 - Rebound Number
SHEET these tests, or any other
The number of unhydrated cement grains remaining tests, accurately represent
(SDS)
on the surface - depth of 150 - 250 τµm. Impact Resistance by Schmidt Hammer: actual design and/or usage
Fewer unhydrated cement grains mean better curing. An increase of 13.3% over untreated samples. environments.
PROPER MAINTENANCE
OPTIMAL PERFORMANCE
...for a lifetime.
MAINTENANCE PROGRAM
An effective maintenance program that includes routine scrubbing with stiff bristle brushes, ample down pressure, and proper amounts of water and
detergent will enhance the floor’s performance significantly. Implementation of the following maintenance program will allow the Ashford Formula to
continue to react with the concrete, lifting contaminants away from the concrete and allowing the marble-like sheen to develop.
Scrub Floor OFTEN: Minimum routine cleaning 2 - 3 times per week with CreteClean Plus with Scar Guard provides superior results.
Clean Spills QUICKLY: After densification is complete, concrete will resist contamination and moisture penetration of most liquids.
Corrosive or aggressively staining contaminants should be removed quickly to avoid possible staining.
RECOMMENDED SUPPLIES
CASE STUDY: NORTH POINT TOYOTA The density and hardness of the floor will be immediately enhanced. However, care should be taken not to gouge the floor with nails, etc.
after the initial placement.
To accelerate the sheen, the floor can be burnished with a high speed propane burnisher and a black stripping pad at 1800 to 3000 RPMs,
or cleaned daily using an auto-scrubber equipped with medium-aggressive nylon brushes. A spiff coat can also be done to enhance the
intial sheen.
The use of truck soap had
caused this floor to have a dull
3-6 MONTHS AFTER TREATMENT
appearance. After a proper
maintenance program was If the standard maintenance program is followed, smooth-troweled floor surfaces will develop a sheen.
implemented, the natural sheen Note: A sheen will not develop on floors with an open, porous finish, or on floors with a broom finish.
from the Ashford Formula was
once again visible. On steel-troweled floors, water typically begins to bead on the surface.
QUALITY
Built in 1949, the Casa de Cadillac dealership in Sherman Oaks, CA, USA is one of the earliest by Cuviello Concrete
THE “ORIGINAL” 4 Improved Thermal Comfort
documented floors treated with the Ashford Formula. This facility is on the California historical
CONCRETE DENSIFER register. Still in use today, the concrete floor has provided more than six decades of continuous 2O12 5 Increased Daylighting;
service and attests to the longevity and durability of the Ashford Formula. Light Reflection
20
As if 65+ years isn’t proof enough of the Ashford CURECRETE -
Formula’s enduring performance, Curecrete
SETTING THE
Distribution, Inc. offers a standard 20-Year
YEARS
OR Product Performance Warranty on Ashford STANDARD,
LIFETIME
PRODUCT PERFORMANCE WARRANT Y
Formula floors, as well as a Lifetime* Product
Performance Warranty - the longest warranty
offered in the industry - when maintained with
RAISING THE
BAR
CreteClean Plus with Scar Guard™.
CUSTOMER (801) 489-5663 REPRESENTATIVES & Ashford Formula is sold through a network of
(800) 998-5664 manufacturer representatives and international
SERVICE INTERNATIONAL
distributors. To contact your representative or
customercare@curecrete.com DISTRIBUTORS distributor, please visit:
www.ashfordformula.com/reps
A S O L I D F O U N D AT I O N , F R O M T H E G R O U N D U P
Because your business productivity requires a solid, DENSIFIED concrete floor.