Lubricator System
Service Bulletin 276 - April 22, 1996
2
Service Bulletin 276 - April 1996
40:1
Gear Ratio
3
Cylinder Lubrication Logic Chart (Example)
RAM / MH / WH / WG
4
RAM
5
From Main Lube System
Plugged if external lubricant is used.
Lubricator System
MH / WH / WG
Pumps
Gear Box
Coupling &
Stub-shaft
Mounting Bracket
6
Pressure Reduction
Orifice
#1=.063”
#2=.078”
Establishes 5-10PSI
7
Force Feed Lube System
8
Typical Divider Valve Type Lubrication System on
Superior C-Force Compressors
9
Premier Lubricator
10
Single Pump Lubricator for Divider Block Type
Lubrication Systems – C-Force Compressor
11
Premier Lubricator - AXIS
12
Premier
Model P-55U Pump
13
Flow Rate Adjustment
• Loosen lock nut on flushing unit
• Turn flushing unit counter-clockwise to increase flow
• Turn flushing unit clockwise to decrease flow
• Tighten lock nut when desired flow rate is achieved
Vent Screw
Pump Displacement
• Maximum Output (per stroke):
Union Nut
Flushing • 3/16” Plunger = .010 Cu. In.
Unit • 1/4” Plunger = .018 Cu. In.
• 3/8” Plunger = .041 Cu. In.
Suctio • The cubic volume for a pint of oil is 28.9 Cu. In. and
n average drop size is .002 Cu. In.
Inlet
• There are approximately 14,500 drops in a pint,
however oil viscosity may vary drop size.
14
Typical Pump Sequence of Events
15
Premier Model P-55U Pump Assembly–Pressurized
Suction (Blind Sightfeed)-C-Force Compressor
16
Exploded
View
17
-Typical External Feed -
Pump Sequence of Events
18
Premier
Check Valves
19
Premier Injection Point Check Valves
C-Force Compressors
Flow Direction
Packing Check Valve
Part No. 90501
Single Ball, Carbon Steel
Rated for 3,000 PSI
Flow Direction
20
DropsA SMX Divider Valve Assembly
General Features:
• Modular Design (Base and Elements)
• Integral Porting Adapter f/ Single to Twin Conversion
• Air Bleeds Built Into Base
• Wide Variety of Element Sizes
• Elements Can Be Serviced Without Disturbing Piping
• Zinc Plated Components
Accessories:
• Cycle Indicators
• Pin Type Pressure Indicators
• Proximity Switches & Digital No-Flow Timers
21
Technical Data – DropsA SMX Divider Valves
Technical Specifications:
• Maximum Pressure: 7,250 PSI (500 Bar)
• Minimum Pressure: 215 PSI (15 Bar)
• O-Ring Material: Viton
• Oil Viscosity: Minimum 15cSt (77.31 SSU)
• Grease: Maximum 200 ASTM (NLGI-4)
• Inlet Thread: 1/4” NPT
• Outlet Thread: 1/8” NPT
Temperature Range:
-40 F (-250 C) to + 3920 F (+2000 C)
22
SMX Metering Element Sizes
23
Deliron Magnetic (Visual) Cycle Indicator
Features:
• Stainless Steel Housing
• Highly Visible Orange Cycle Indicator
• Mounts on Any Size Metering Element
• Fully Enclosed
• Replaces Leaking Mechanical Cycle Pins
24
Removing air from the lubricator line.
25
26
Inlet
Section
Section
No. 1
Section O-Ring
No. 3
End
Section
Lube Rates for Superior Compressor
Cylinders and Packing
Packing
Rod Diameter X 2/5(.2) pint / day
Cylinder
Cylinder Diameter X 1/5(.4) pint / day
Break-in
2 x the normal lube rate
28
Reference – ES 1002
Divider Valve
Cycle Frequency Examples
1. SMX-3 (08T-08T-08T) Divider Valve
.030 Cu. In to make 1 complete cycle
@ 18 ppd. .030 x 3,000 Divided By 18 = 5 Seconds Per Cycle (12 Cycles Per Minute)
@ 9 ppd. .030 x 3,000 Divided By 9 = 10 Seconds Per Cycle (6 Cycles Per Minute)
@ 4 ppd. .030 x 3,000 Divided By 4 = 22.5 Seconds Per Cycle (2.6 Cycles Per Minute)
@ 18 ppd. .090 x 3,000 Divided By 18 = 15 Seconds Per Cycle (4 Cycles Per Minute)
@ 9 ppd. .090 x 3,000 Divided By 9 = 30 Seconds Per Cycle (2 Cycles Per Minute)
@ 4 ppd. .090 x 3,000 Divided By 4 = 67 Seconds Per Cycle (.90 Cycles Per Minute)
29
DNFT Products
Digital No-Flow Timers
DNFT-PRG
DNFT-LCC-AC
Mounted on SMX-3 Assy.
30
DNFT-LED Digital No-Flow Timer
DNFT Features:
• Monitors Movement of Divider Valve Piston
• Fixed 2-Minute Alarm Time
• Closed Loop or Open Loop
• Requires No External Power
• Installs Directly To Divider Valve
Ratings:
• Not Affected By Temperature or Viscosity CSA C-US 186200
• Blinking LED Cycle Indication Class 1, Div. 1, Groups A,B,C,D: T4
CE 0344
• Dependable Timed Shutdown Protection Class 1 Zone 1, Ex md IIC T4
• Field Replaceable Battery is Standard Ex II 2G EE x m IIB T5
KEMA 00ATEX1090 X
Amb. –400C……+850 C
31
Atmospheric Rupture Indicator
32
33
Any
Questions?
34