Você está na página 1de 4

www.hilti.com.sg/holsg Hilti PROFIS Rebar 2.4.

10
Company: Page: 1
Specifier: Project: Felco Panel Top Stiffener
Address: Fastening point:
Phone | Fax: | Date: 25/09/2018
E-Mail:
Specifiers comments: L1 Blk 421A

Design standard: EC2 / ETA


Application type: Standard applications/Simply supported column/beam

1. Loads 2. Drilling & Temperature 3. Material & Safety

Loads Drilling Structure


Md 0.00 kNm Hole Dry Concrete class (existing C20/25
condition structure)
Nd 0.00 kN
Drilling Hammer Char. yield strength (existing) 460 N/mm²
Vd 1.70 kN method drilling Char. yield strength (new) 460 N/mm²
Fire design Drilling aid Drilling aid is
used
Fire rating None
Temperature (EC2/ETA)
Fatigue design
During from 5 °C to
None installation 40 °C
Seismic During 50 °C / 40 °C
Seismic loads No service

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg/holsg Hilti PROFIS Rebar 2.4.10
Company: Page: 2
Specifier: Project: Felco Panel Top Stiffener
Address: Fastening point:
Phone | Fax: | Date: 25/09/2018
E-Mail:

4. Eurocode 2 parameters 5. Post-installed reinforcement

αcc 1.00 EC2 3.1.6(1) Number of layers


αct 1.00 EC2 3.1.6(2) Number of top layers 1.00
Number of bottom layers 1.00
αct,bond 1.00
Top reinforcements parameters
εud 0.0200 Table C.1
Top diameter 8.00 mm
k2 0.850 EC2 6.5.4(4b) Top spacing 42.0 mm
ν' 0.920 EC2 6.5.2(2) Top layer 1: c 20.0 mm
ρmax 0.0400 EC2 9.2.1.1 Top layer 1: cd (EC2, 8.4.4.1) 17.0 mm
εc2 -3 Table 3.1
2.00•10 Top bond condition Good
εc2u 3.50•10 -3 Table 3.1 Top min. reinforcement 100 mm²/m
Bottom reinforcements parameters
Bottom diameter 8.00 mm
Bottom spacing 102 mm
Bottom layer 1: c 20.0 mm
Bottom layer 1: cd (EC2, 47.0 mm
8.4.4.1)
Bottom bond condition Good
Bottom min. reinforcement 100 mm²/m
Other
Transverse pressure 0.00 N/mm²
Cover of tension force line b 0.00 mm

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg/holsg Hilti PROFIS Rebar 2.4.10
Company: Page: 3
Specifier: Project: Felco Panel Top Stiffener
Address: Fastening point:
Phone | Fax: | Date: 25/09/2018
E-Mail:
Selected solution
Bar size Drill bit size Bar spacing Distance Drilled hole Anchorage for
centre/centre centre/surface required yield of bar
Layer of bars Φ [mm] D [mm] s [mm] cs [mm] ℓvreq [mm] ℓvy [mm]
Top / left 1 8.00 12.0 42.0 124 104 N/A
Bottom / right 1 8.00 12.0 102 124 104 243

Required accessories

Drilling Cleaning Setting


- Suitable rotary hammer - Compressed air with required accessories to - Dispenser including cassette and mixer
- Properly sized drill bit blow from the bottom of the hole - For deep installations, a piston plug is
- Proper diameter wire brush necessary

Section Analysis

Strut angle θ 21.8 ° EC2 6.2.3


Inner lever arm z1 57.0 mm
Compressive reinforcement required? no

Upper layer
Design Input

Design force in bar FE 0.00 kN EC2 9.2.1.4(2)


Stress in bars σsd = FE/As,prov
Adhesive used Hilti HIT-RE 500 V3

Minimum Anchorage Length

Basic anchorage length (Fyd) lb,rqd,fyd = (Φ/4)•(fyd/fbd) 348 mm EC2 8.4.3

Factor for minimum length fmult,min 1.00 ETA 16/0142


Minimum anchorage length lb,min = fmult,min•max(0.3lb,rqd,fyd; 10Φ; 100 mm) 104 mm EC2 and
German
Nationaler
Anhang

Installation length linst = lbd 104 mm

Lower layer (tension side)


Design Input

Design force in bar FE 1.06 kN EC2 9.2.1.4(2)


Stress in bars σsd = FE/As,prov 21.1 N/mm²
Adhesive used Hilti HIT-RE 500 V3

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg/holsg Hilti PROFIS Rebar 2.4.10
Company: Page: 4
Specifier: Project: Felco Panel Top Stiffener
Address: Fastening point:
Phone | Fax: | Date: 25/09/2018
E-Mail:

Anchorage Post-Installed Reinforcement

Bond condition Good → η1 1.00 EC2 8.4.3(2)


Bond strength fbd,pi 2.30 N/mm² ETA 16/0142
Basic anchorage length lb,rqd = (Φ/4)•(σsd/fbd,pi) 18.4 mm
Basic anchorage length (Fyd) lb,rqd,fyd = (Φ/4)•(fyd/fbd,pi) 348 mm

Factor for minimum length fmult,min 1.00


Minimum anchorage length l0,min = fmult,min•max(0.3lb,rqd,fyd; 10Φ; 100 mm) 104 mm EC2 8.4.4(1)
and German
Nationaler
Anhang

Min of clear cover or half spacing cd 47.0 mm EC2 8.4.4(1)


Influence cover/spacing α2 = {0.7 ≤ 1-0.15[(cd-Φ)/Φ] ≤ 1.0} 0.700

Transverse reinforcement ∑Ast = Φt2•π/4 • (1+0.7•lb,rqd/st) 0.00 mm²


Min. transverse reinforcement ∑Ast,min = (EN 1992-1-1, table 8.2) 12.6 mm²
K-factor K = (EN 1992-1-1, table 8.2) 0.0500
Influence of transv. reinf. α3 = {0.7 ≤ 1-K(∑Ast-∑Ast,min)/(Φ2π/4)≤ 1.0} 1.00 EC2 8.4.4(1)

Transverse pressure p 0.00 N/mm²


Influence of transv. pressure α5 = {0.7 ≤ 1-0.04p ≤ 1.0} 1.00

Design anchorage length lbd = max(α•lb,rqd; lb,min) 104 mm

Definition of the installation length

Controlling anchorage length lbd 104 mm

Installation length linst = lbd 104 mm

Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and
existing concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that
adequate transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The Installation (drilling, cleaning, setting) must be according to the approval!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
Minimum reinforcement requirements are not checked by the software.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan