Você está na página 1de 1

23° Notes

RC
2712 B RC 5000 B RC 4378 B1 4378
325 250
2648 1321 4150
C 1. All dimensions are in millimeters and levels are in meters, unless otherwise

Plant North

th
specified.

Nor
2. Details shown like structure / civil / architecture are indicative. Refer related

ual
drawing for the same. (i.e. stair, roof, column, wall etc.)

PS
162

Act
3. Dimensions marked ( * ) shall be as per manufacturer standard based on
65DN Foam solution line 65DN Foam solution line PS
specification & capacity of the foam maker.
4. Foam Nozzle location and size shown as per drawing no.

2700
6000
65DN Foam solution line 65DN Foam solution line 383429-PTJSE-SPD-100M3-07, Rev. G, sh. 1 of 17 of, PT. JUHDI SAKTI Engg.
5. Foam piping ring header staircase overlap shown as per drawing no.

23000
383429-PTJSE-SPD-100M3-07, Rev.E, Sh. 9 of 17 of, PT. JUHDI SAKTI Engg.

1150
1632
PS PS 6. For detail of MVW header and foam header refer drawing No
B B B1
383429-MMD-74-XX-DR-PS-0018-02
Abbreviations : HPP High Pavement Point
FGL Finished Ground Level Existing Area
C C
PS FFL Finished Floor Level Paved Area

2100
3813
TOF Top of foundation Pipe rack

1650
TOS Top of Structure Typ Typical
1.5m High Dyke wall 1 2 1 ℄ of 65DN Foam solution line
C/L Center Line Lvl Level
A A 2 ℄ of 65DN Foam solution line PS Pipe Support
TOS EL. +13.000
E Key to symbols
3149

3 4 3 100DN spray header for shell 3 PS 3 N

590
4 50DN spray header for roof

2000
TOS EL. +13.000

h line
Matc

65 DN PS
PS Flexible Tube 600 3510 640
HPP + 10.300 Boiler House
255° 285°
65 DN Ring HPP + 10.600
Ring Header Header
4150

PS
Support (Typ.)

2450
270°
0
40

225° N17A/100

6000
315° 2520 7400 3380 4150 MFO Tank

6000
E
65 DN Ring C C
Header 65 DN Riser
3500

6000
N17A/100- 340° PS Key Plan
195° 341° Reference drawings

1. 383429-MMD-00-XX-DR-AR-0001 Plot Plan


220
2. 383429-MMD-00-XX-DR-PS-001 P & I Diagram for fire protection system

2450
180° 0°
3. 382429-MMD-00-XX-DR-PS-016 Layout and details - Foam solution header
Foam Maker
65 DN inlet x 4. 383429-MMD-74-XX-DR-PI-0736 Equipment Layout Plan - 74 - US 1 Boiler
165° 76-T-707 100 DN outlet
161° Medium Fuel oil
N17B/100
160°
65 DN
Tank 4.90D x 9.10H 76-T-706
C6 Light Ends Tank
4.90D x 9.10H
4 PS 4
Riser
76-T-705 PS
Foam Maker Demin Water Tank

3000

PS

PS
65 DN inlet x 5.83D x 9.2H
100 DN outlet 150DN Foam
solution header
(Ref. Note-6)
2
90°
-

5
4705

C3 1
1.5m High Dyke wall
- 6000
LPP+10.100
C3

C03 24/12/18 KP Revised as marked & issued for construction JT GS

C02 06/11/18 KP Issued for Constructino JT GS

C01 26/04/18 KP Issued for Construction JT GS


Layout of Proposed Fixed foam system for MFO Tank
1:50 150 250
1 2
825
1 ℄ of 150DN Fire Water header
2 150DN Foam solution header N17A/100
340°
C P01

Rev
06/11/18

Date
KP

Drawn
Issued for Approval

Description
JT

Ch’k’d
GS

App’d
175 Foam Maker 65DN C
TOS+13.800 inlet x 100DN outlet TOS+13.800 Status Stamp
Process Piping Process Piping *
80 kg/mtr. 165 640
FOR CONSTRUCTION
256

170 230
350

12 TOS+13.000 12 Graha CIMB Niaga

1500
TOS+13.000 TOS+13.000
1 65DN Foam solution line 65 DN 16th Floor
95 kg/mtr. 76-T-707
800

80 kg/mtr. 80 kg/mtr. 165 2 65DN Foam solution line Riser


Medium Fuel oil Jalan Jenderal Sudirman K
21 12 Solid 100
1070

3 4 4 3 Tank 4.90D x Jakarta, 12190


756
450

500 1 65DN Foam solution line Deflector DN D


4
*

Max. 170 3 ℄ of 100DN spray header 9.144H


600

2 65DN Foam solution line outlet Indonesia


*

170 Liquid 4 ℄ of 50DN spray header


4 3 4 3 Level T +62 21 2985 0000
850 842 220 F
3 ℄ of 100DN spray header

531
℄of Rack 65 DN
4 ℄ of 50DN spray header inlet W www.mottmac.com
1500
column
150Sq. Boiler
Client
Pipe Section House
B Section Pad plate
PT Apical Kao Chemicals
2500

B1
242

326

165
support
1:50 1:50
- Desa Lubuk Gaung

1619
-
1500

Kec Sei Sembilan

197
150DN Foam 150DN Foam PS
1.5m High 400
solution
Dyke wall
TOS+13.800
solution header
65 DN Foam
2nd Platform
header 65DN "Y" 150DN Foam Dumai-Riau

238
solution header
Indonesia

923
(Typ.)

Strainer
1500

solution header (Typ.)


Section 80 kg/mtr. Tank (Ref. Note-6)
A FFL+10.600
1258

169
Shell 65 DN Ring

PS

PS
1:50 65 DN Title
- Header for Drain
TOS+13.000 Flexible
N17B/100 @160°
valve PT Apical Kao Chemical Project

200
FFL+10.100 Tube
95 kg/mtr.
℄ of column

165
950 TOS+13.000
0
50

65DN Foam 350


solution line 95 kg/mtr. Layout and Details
3946

Solid
3785

"U" Bolt
C
3570

350 Deflector 65DN Gate 65DN Foam ℄ of Tank Fixed Foam system for MFO Tank
Section 574 250 250 350 200
238
350

Foam Maker valve (IV) C solution line


65 DN inlet x
220 Support
Member
150DN Isolation
valve (IV)
D Sheet 1 of 1
1:50 -
100 DN outlet
N17B/100 65DN Designed KD Panchal KDP Eng check J.M.THAKKAR JT
1900

Typical Elevation for Foam Maker


240

"Y" Str.
160° Drawn K.PANCHAL KP Coordination N.SOLANKI NS
240
TOS+10.400 Pad Plate details for fixed foam piping arrangement
320 1
47 kg/mtr. Tank Description Pad Plate details TOF + 10.800 100 Dwg check J.M.THAKKAR JT Approved G.D.SHAH GS
FFL + 10.100 Tank # Qty. Tank Description ℄ Elevation Degree Pad plate MMD Project Number Scale at A0 Security
Description / distance from (150Sq.x8Thk.) Detail
65DN Ball 650
1500
1 383429 AS SHOWN STD
Detail 2 valve (IV) Size (I.D. x Ht. ) TOF of Tank qty. in Nos. C3
For Fixed 3.570, 5.070m, 141°, 361°. 1x4x2 = 8 1:20 - Suitability Description Suit. Code
1:20 - Section D 4 76-T-707 01
Medium Fuel oil foam Riser. 6.570m, 8.070m 3500
© Mott MacDonald Pvt Ltd
1:50 -
Tank For Fixed foam Ring
(4.90D x 9.10H) header 3.570m.
165°, 195°, 225°, 255°, 1x1x6 = 6
Section E 1:20
0 1m 2m
Construction Record CR
285°, 315°.
2.5m Drawing Number Revision
This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose. 0 5m
1:50 -
We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties. 1:50 383429-MMD-74-XX-DR-PS-0020 C03
C:\Users\pan35768\OneDrive - Mott MacDonald\Fire Projects working\383429 - Apical OleoChem IET Indonesia\74_US 1
Boiler\Foam\Paper\383429-MMD-74-XX-DR-PS-0020.dwg Dec 24, 2018 - 5:53PM PAN35768

Você também pode gostar