Você está na página 1de 2

How To Install Driver (USB Mode) SOUTH TOTAL STATION UPLOAD USING SD Card

How to install driver and software (south software) 15. Double click the new SOUTH SOFTWARE
Cable must Plug-in (TS and to the Computer/laptop) Note: File extension accepted isTEXT FILE...
Note: When using usb mode, install first the USB DRIVER Format:P, E, N, Z, D (comma delimited)
- In Windows XP Operating system no need to set the
compatibility mode
Ex. txt file comma delimited
Quick Reference Guide
In Win7 Operating system
1. Right click the driver (NTS-360 US Driver) 16. Click USB Comm NTS-310B/330R Series
NTS-312B/NTS-332R4/NTS-332R5
1. Inset SD card into the total station slot
2. Press MENU
3. Press 3.MEMORY MGR.
17. Select Download 600 Data(N)
4. Press 3.File Import
2. Click Properties 5. Press 1.Coord File Import
3. Click Compatibility Tab 6. Press F2: LIST.
4.  Check (Run this program in compatibility mode 7. Select Disk:B and Press F4 (OK)
5.  Check (Run this program as an administrator
8. Use Up or Down arrow to select the file
9. Press ENT on the keypad
18. On South Total Station Press 2.NTS-660 10. Press 2 (NTS-660)
After South Total station connecting to the Computer 11. Create a FILE:__________using keypad
MEAS. DATA [USB] To be save in the internal memory
6. Click Apply Click OK
File: A:\Roger.SM 12. Press F4 (ENT)
7. Double Click NTS-360 USB Driver (exe file)

STOP How to Check Communication Port


INSTALL South Downloading Software (Windows XP)
8. Double click the South downloading software 1. Right Click “My Computer” Icon on Desktop

19. Press OK 2. Select Properties


3. Click Hardware Tab then Device manager
4. Click Ports(COM & LPT) :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
5. See Communication Port
6. Ex: (COM1) SHORT PRESS LONG PRESS
TO POWER ON TO POWER OFF
20. Press Ok DONE…

CONTRAST ADJUSTMENT PRISM MODE


NTS-365R (Download using SD-CARD) How to Check Communication Port
Press Star Icon () Press Star icon ()
1. Press MENU (Windows Vista & Windows 7/8)
Follow the procedures until the software are installed Press Arrow Up to lighten Press K1◄or K2►set PrismMode
2. Press 3.MEMORY MGR.
Click Next> - Next> - Next> - Next> - Finish …… End… 1. Right Click “My Computer” Icon on Desktop Press Arrow Down to darken (Prism)/(Non-Prism)/(Sheet)
3. Press 4.FILE OUTPUT
2. Click Device Manager
4. Press 2.Coord File Export
Download uszing USB mode 3. Click Ports(COM & LPT)
5. Press F2: LIST
SOUTH TOTAL STATION TILT OVER CHANGE FT. TO M UNIT
6. Select Disk: A and Press F4 (OK) 4. See Communication Port
1. Press MENU
2. Press 3: MEMORY MGR.  Use Up or Down arrow to select the file 5. Ex: (COM1) Press Star Icon () Press (M)Menu
3. Press 2.Data Transfer 7. Press ENT on the keypad Press F2 (Tilt) Press F4 CONFIG
4. Press 2. USB Mode 8. Press 2.NTS-660 ================================== Press F1 (ON) Press F1 (Unit Set) - Press F4 (Dist)
5. Press 3 COMM. PARAMETERS 9. Create File name on the SD-CARD Press F3 (OFF) Press F1 (M)Meter then Enter
6. PROTOCOL MUST BE (ONE WAY) to change Press Menu   EX. FILE:__OJING_____________
SURVEYTECH TRADING Press F4 (OK) Press F2 (F)Feet then Enter
7. Press F4 (SET) 10. Press F4 (ENT)
8. Press 1.SEND DATA 11. COMPLETE 175 Ilocos Sur Street, Brgy.Sto.Cristo, Bago Bantay, Quezon City
9. Press 1. MEAS. DATA Note: Output data is Text file comma delimited… FOR LASER PLUMMET MODEL
Tel Nos.: +632 453-9426, 920-6224 | Fax No. +632 927-3240
10. Press F2 (LIST) TO ACTIVATE LASER PLUMMET
Email Add: survetech@yahoo.com.ph
11. Select Disk: A Press Star Icon ()
12. Press F4 (OK) Use  arrow on the keypad to select Press F4 (LSR)
13. Press ENT on the keypad For Technical Support, Pls.call or text us at: Press F1 (ON)
14.  (STANDBY). . . . . . . . . . Press ESC
Globe: 0917-956-2410
Smart: 0908-815-0207
TOPO / TRAVERSE / SIDESHOT  Press on the keypad (scroll down) Press  on the keypad (scroll down) 6. Press F1:MLM1(A-B A-C)
3. Press ENT on the keypad to select/confirmed Press ENT on the keypad to confirm 7. FOCUS THE TARGET PRISM
OPEN OR CLOSED TRAVERSE PROCEDURES 4. Press F1 (INPUT OCC.PT#) then Press F3 (OCC) 11. Press F4 (NEZ)
1. Press M on the keypad then Press F1(COLLECT DATA) <STEP-1>
5. Input Point number using keypad Input coordinates of the backsight point
2. Create File : ___________ Press F4 (ANG) use angle to set backsight 8. Press F1 (MEAS)
Ex. PT#:10______ current OCC point
Ex. FILE : ACE________ 12. N:20001.000 Press ENT on the keypad 9. Press F4 (SET)
6. Press ENT on the keypad to confirm
 Create or type file name using keypad 13. E:20002.000 Press ENT on the keypad
7. Press F4 (YES) to confirm ( if it is correct) 10. Focus next target/next point
 F1(BACK) to edit Calculated Angle will display
8. Press F1 (INPUT) Edit information on the screen <STEP-2>
 F2(LIST) to search existing file 14. Focus the target PRISM
9. Press so keypad (scroll down) to select (2x) 11. Press F1 (MEAS)
 F3 to change number to alpha numeric 15. Press F4 [YES] Set reference angle
 Press ENT on the keypad) to confirm 10. I.HT ▶1.040 Press(ENT) on the keypad 16. Press F3: LAYOUT 12. Press F4 (SET)
Or enter the file name you’ve created (selected) 11. Press F4 (SAVE)  Input point number stored in the memory 13. Display (HR,dHD,dVD,dSD)
F1-(Back) to EDIT
3. Press ENT on the keypad to confirm 12. Press F4 (YES) to confirm Press ENT on the keypad to confirm
F3-(NUMB/CHAR) 14. Press F4 (NEXT)/measure next point
4. Press F1 (INPUT OCC. PT#) then Press F1 (INPUT) 13. Press F2 (BACKSIGHT)  F2 (LIST) searching Data in the memory
5. PT# 1 Press(ENT) on the keypad AREA–Calculate the Area
14. Press F3 (BS) Press on the keypad (scroll up)
6. PCODE T1 Press(ENT) on the keypad Press  on the keypad (scroll down)
1. Press M on the keypad
15. Input Point number using keypad
7. I.HT 1.540 Press(ENT) on the keypad Press ENT on the keypad to confirm 2. Press F2: MEAS PROGRAM
Ex. PT#:1 ___ is your BS point
8. Press F3 (OCC) then Press F4 (NEZ) Press F4 (YES) 3. Press F3:AREA
16. Press ENT to confirm
Input Coordinate Assumed or True 17. Press F4 (NEZ)
17. Press F4 (YES)  F1:FILE DATA /Calculate the Area using File in
9. NO :20000.000 Press(ENT) on the keypad Input coordinates of the point to Layout
Calculated Angle will Display
10. EO :20000.000 Press(ENT) on the keypad the internalmemory
18. Focus the target prism 18. N :20005.000 Press ENT on the keypad
11. ZO :20.000 Press(ENT) on the keypad
19. Press F4 (YES) to release/confirm (SET) 19. E :20004.000 Press ENT on the keypad  F2:MEASURE/ Calculate the Area using
12. Press F4 (SAVE) then Press F4 (YES) 20. Z :19.000 Press ENT on the keypad
20. Press F4 (MEAS) direct measuring
13. Press F2: INPUT BACKSIGHT 21. R.HT:1.3____ Press ENT on the keypad
14. Press F1 (INPUT) 21. Press F3 (NEZ) 4. Press F2:MEASURE
22. Display Calculated Angle and Distance
15. PT# ▶2 Press ENT on the keypad  Press F3 (STOP) to end reading 5. FOCUS THE TARGET PRISM
23. Press F4 (NEXT)
 Press F2 (PLOT) to view data points
16. PCODE: ▶ TX____ Press ENT on the keypad 24. Rotate the instrument to get dHR 6. Press F1 (MEAS) then Press F4 (YES)
 Press F4 (SAVE) to store data dHR=0°00'00" (location point)
17. R.Ht : ▶1.045 m Press ENT on the keypad 22. Press F4 (SAVE) 25. Press F2 (DIST)
7. Focus the prism… Do the same (5 and 6)
18. Press F3 (BS) …REWRITE? [NO] [YES]… dHD: must set to zero”0” 8. Calculated Area displayed as follows…
19. Press F4 (NEZ) Ex. dHD: 80.123 m
23. Press F3 [NO] Ex. S = 203.222 m²
input true coordinate if they have, if not? dHD: 0.000 m (location point)
20. Press F4 (ANG) 24. Press F3 (MEASURE) RESECTION
26. F1 (MEAS) change the instrument reading
Input or type “0” or 180 on the keypad to orient due north  Edit the PCODE first 1. Press M on the keypad
27. F2 (ANG) to checked the angle
21. Press ENT on the keypad to confirm 25. Press F4 (REP) to get data 28. F3 (NEZ) to get as built of the point 2. Press F2:MEAS PROGRAM
22. Focus the target prism to set BS Continues collecting data 29. F4 (NEXT) to set another point to Layout
If you set another station you must 3. Press so  down arrow on the keypad
23. Press F4 (YES) to release 30. Do the same? Follow number 29 (Layout)
RECORD the Point number/PCODE/Remarks... 4. Press F4:RESECTION
24. Press F4 (MEAS) to select what data to save in Ex. POINT 67_________
25. Press F3 (NEZ) to get coordinate of your BS REM- Remote Elevation Measurement 5. Create Any filename
PCODET9_________or remarks
 Press F3 (STOP) to end reading Ex. Output: 67/T9 1. Press M 6. Press ENT on the keypad
 Press F2 (PLOT) to view data points LAYOUT 2. Press F2:PROGRAMS then Press F1:REM 7. Press F4 (JUMP)
26. Press F4 (SAVE) 1. Press so on the keypad 3. Press F2:NO PRISM HT 8. Press F1:DIST RESECTION
27. Press F3 (MEASURE)  Press F2 (LIST) if you have file in the internal memory 4. Focus the Target PRISM 9. I.HT:_____ if needed Press ENT on the keypad
28. Press F1 (INPUT) to set info. On the screen.  Press on the keypad (scroll up)
3 5. Press F1(MEAS) then Press F4 (SET) 10. Pres F4 (NEZ)
29. PT# Press(ENT) on the keypad  Press  on the keypad (scroll down)
30. PCODE :SPOT Press(ENT) on the keypad 6. Focus the telescope to the first point Input coordinates of the first point (known)
 Press ENT on the keypad to confirm
31. I.HT :1.540 Press(ENT) on the keypad 7. Press F4 (SET) 11. N:20000.000 Press (ENT) on the keypad
2. CreateFilename/Folder name
32. Press F4 (REP) get reading of a point 3. Press ENT on the keypad to confirm 12. E:20000.000 Press (ENT)on the keypad
8. Tilt the telescope to the next point measure VD:____ it will
33. Press F4 (SAVE) F1-(Back) to EDIT 4. Press F1: INPUT OCC.PT# 13. Z:20.000 Press (ENT)on the keypad
change 14. R.HT: if needed Press (ENT) on the keypad
Continues collecting data F3-(NUMB/CHAR)  Input directly point number stored in mem
If you set another station you must  F2 (LIST) searching data on the memory  Press F2 (Vang) to returned 15. FOCUS THE TARGET PRISM
RECORD the Point number/PCODE/Remarks... 16. Press F1(MEAS)
5. Press F4 (NEZ) / input coordinate  Press F3 (HD) to set another point to measure
Ex. POINT 10________ 17. Press F4(NEZ)/input coordinates of the next point (known)
Input coordinates of the occupied station (STN) MLM–Missing Line Measurement
PCODET2________is the remarks 18. N:20000.000 Press (ENT) on the keypad
6. N:20000.000 Press (ENT)on the keypad
Ex. Output: 10/T2 1. Press M 19. E:20000.000 Press (ENT)on the keypad
Next Station Settings 7. E:20000.000 Press (ENT)on the keypad
8. Z:20.000 Press (ENT)on the keypad 2. Press F2:MEAS PROGRAM 20. Z:20.000 Press (ENT)on the keypad
OPEN OR CLOSED TRAVERSE PROCEDURES 21. R.HT: if needed Press (ENT) on the keypad
9. I.HT: if needed - Press (ENT)on the keypad 3. Press F2:MLM
1. Press M on the keypad 22. FOCUS THE TARGET PRISM
10. Press F2: INPUT BACKSIGHT 4. Create Any Filename/Press F4 (JUMP)
2. Press F1 (COLLECT DATA) 23. Press F1(MEAS)
 Input point number stored on the keypad
To select Data/folder name 5. Press ENT on the keypad  Press F1 (NEXT) Measure another point
Press ENT on the keypad to confirm
 Press F2 (LIST) 
 F2 (LIST) searching Data in the mem F1 Continuous reading from 1st point  Press F4 (CAL) to calculate coordinate of the occupied point.
 Press  on the keypad (scroll up)
Press on the keypad (scroll up)  F2 Point to point measurement 24. Press F4 (CAL) then Press F4 (YES) ...FINISH…

Você também pode gostar