Você está na página 1de 8

CURRICULAM VITAE

Full Name: ALLURI JANAKI RAMA ANJANI PRASAD

Address: #06-94, BLK-123


MARSILING RISE,
Singapore-730123

Mob. No: +65 84281453

FIN No: G8057432R

Email: prasad@ias.sg

Career Objective: To grow high with the organization this provides sample of opportunities to learn
and to develop my existing skills by putting sincere and dedicated efforts for the mutual growth and
development of the company.

Job Objective: To seek a Quality Environment where my knowledge can be shared and enriched.

Passport Details:

Passport No: Z2500903

Place of Issue: SINGAPORE

Date of Issue: 16/07/2013

Date of expiry: 15/07/2023

Educational Qualifications:

 M.Sc. (Electronics) from A.G.L P.G College, Andhra University, VISAKHAPATNAM (A.P.) 1 st
Division with 66.2% division with 66.2% in April 2005. 

 B.Sc. M.E.Cs (Maths, Electronics & Computer Science) from RITAMS College (A.U), TANUKU (A.P)
1st division with 73.16% in March 2003. 

 Intermediate from Board of Intermediate Education, Andhra Association (U.K) Jr.College,
PENUMANTRA (A.P) Compartmentally with 54.8% in Dec1999. 

 S.S.C. from Board of Secondary Education, A.K.T.P High School, Tanuku, 1 st Division with 75.6%
in March 1997. 

Page 1 of 8
Key Skills:
Field Analytical instrumentation: Testing, Maintenance, Calibration, Commissioning & troubleshooting
of different types of portable and real time process gas and liquid analyzers systems and integrated
analyzer system packages including Analyzer house HVAC, safety system PLC and Sample handling
systems for the analyzers.
Computer Province:
Operating Systems : Windows 98, 2000, XP.
Packages : MS-office 2K Pro/Xp.

Previous Job 1:

Company : SWAN ENVIRONMENTAL PVT.LTD.


Madhapur, Hyderabad-500081
Website: http://SwanEnviron.com

Department : Environment Health & Safety Tec.

Designation : Service Engineer.

Employee Code : AP/34248/166.

Employment Period : May 2005 to Apr 2007.

Total experience : 2 Years.

Nature of Job:

 Calibration, Testing, Commissioning and trouble shooting of real time field instruments like Online
dust & Opacity Monitors (MIP-OY, Finland), Analysers (SHIMADZU, Japan) & Portable Flue Gas
Analysers (Eurotech, USA), Weather Monitoring Stations (Watch Dog). 

 Installation, Testing, Calibration and trouble shooting of all portable safety instruments like basic
Sound Level Meters, Integrated data logging sound level meters, Noise Dosi Meters, Particulate
monitors & Indoor Air Quality Monitors from QUEST Technologies USA. 

 Testing, calibrating and perform bump test for all types of portable Toxic Gas Detectors, VOC
monitors, and real time perimeter monitoring systems from RAE Instruments USA. 

 Provide technical support to the customers as well as technical training for the end users regarding
calibration and routine maintenance of the equipment supplied. Support the team involves in the
annual maintenance contracts and working on site. 

Page 2 of 8
Previous Job 2:

Company : RADIANT Instrument and Electrical Engineering Pte Ltd.


5 Pandan Loop,
Singapore 128223
E-mail: radiant@radiant.com.sg

SHELL Chemicals Seraya Site Office:


61 Seraya Avenue
Singapore 627832
E-mail: radiant5@singnet.com.sg

Department : Maintenance (QMI)

Designation : Sr. QMI Technician (Supplied to SHELL


Chemicals Seraya)

Employment Period : July 2007 to Jan 2010.

Total experience : 2.5 Years.

Nature of Job:

 Calibration, Testing and Maintenance of different types of Gas Analyser and Gas Detection
System includes. 

 Testing of Sample transport Systems and sample conditioning systems. [Includes Field Instruments,
Temperature Transmitters, Pressure Transmitters, Different Types of Air operated / Electric
operated Valves, Sample Gas Coolers, Sample pumps, Pressure Switches, Temperature Switches
etc.] 

 Perform hands-on maintenance, repair and servicing of online process analysers along with
sample handling systems and fire and gas detection system packages those used for monitoring
the environment and produced explosive and toxic gases. 

 Ensure the availability of analyser systems including Process Gas Chromatographs. 

 Generate daily and monthly reports to reflect the percentage availability of analyser systems
and drawing up failure cause reports. 

 Review and monitor the daily performance of the process analysers with the affected area
operation team. 

 Develop all the required reliability KPI to monitor the online analysers daily. 

 Perform the safe guard check for the fire and gas detection system (Toxic and flammable
gas detectors) according to the planned schedule. 

Page 3 of 8

 Lead root cause analysis on analyser related problems. 

Types of process analysers handled:

 Process Gas and liquid gas chromatographs (YOKOGAWA GC-1000) 


 Oxygen analysers extraction type from Servomex 
 Rosemount zirconium oximetry in-situ models 
 pH, conductivity, Dissolved Oxygen from Rosemount and YOKOGAWA 
 HACH Chlorine analyser, Total Organic Carbon analysers 
 Dust monitors from SICK Mihak 
 Mettler Toledo Trace dissolved oxygen meter 
 Oxygen analysers from Orbisphere 
 Toxic and flammable gas detectors from Honeywell 

Previous Job 3:

Company:
AXIS ENGINEERING PTE LTD
29 Senoko Way
Singapore 758059
Website: www.axisengg.com

Department : Projects and Service

Designation : Service Engineer.

S Pass Number : 0 33890168

Period : Feb 2010 to Mar 2012.

Total experience : 2 Years plus.

Nature of Job:

 Conducting In-house testing and FAT for Integrated Analyser system Packages, HVAC and
Analyser Houses along with the safety system PLC. Prepare the In-house test reports and FAT
reports to support the corresponding project documentation. 

 Perform the leak check for the Sample conditioning systems, pressure reducing systems and
sample probes. 

 Start up new Analyser and sample handling systems. Calibrate the gas and liquid analysers
and perform the 8-hr. stability test run as per the project specification. 

 Testing of Analyser Shelter System, Ex-proof & weather proof Electrical panels (PLC
Logic/Relay Logic) 

Page 4 of 8
 Conducting SAT and Site commissioning of analyser system packages, shelter, and
accessory equipment. Maintenance support and repair of faulty analyser and equipment on
site. 

Types of process analysers handled:

 COSA 9610 and WIM 990 Wobbe Index 


 Thermo Sola II Total sulphur Analyser 
 ABB RVP Analyser Model 4100 / 4500 
 ABB Advanced Optima 2000 CEMS analysers, PGC 2000 
 Galvanic H2S Analyser Model 902 and 903 
 Ametek Analyzers,SO2 920, H2S 933, Moisture Analyser OLV 3050. SLR 3050 & 5000,
 Oxygen Analyser 2000 Thermax 
 Emerson Rosemount pH ,Conductivity ,Chlorine, Dissolved Oxygen 5081 Transmitters,
 Rosemount Oxygen Analyser Oxy 4000 / WC 3000 
 Mettler Toledo Dissolved Oxygen 4100e, pH 2100e and pH Easy clean 400 , Conductivity
7100e, 
 Sick Maihak TOC Analyser Unor 200, Oxygen Analyser Maihak Oxor 620 Ex 
 Yokogawa Conductivity meters and PGC Analyser GC1000 & Mark II 
 HACH Chlorine Analyser 
 Servomax 1100 & 2700C Oxygen Analyser 
 TOD Analyser Make of Ionics 
 MIR 9000 Environmental SA NH3 Analyser 
 Emerson Xstream X2 SO2 analyser 
 Dust measuring device PFM 97 ED from Dr.Fodisch 
 TD-4100 Online Hydro Carbon in water monitor from Turner Designs 
 Dew Point analyser Endress Hauser rh 2250 & General Eastern Sensor 
 Micro Motion Density & Viscosity analyser 
 Daniel metering GC 700 from Emerson 
 Honey well XNX & XCD Gas detectors 
 HVAC Bird well BTB60 &72, custom control 
 PLC Siemens and Schneider 

List of Major Projects Involved: 

 Conduct In house test and FAT for AOFP (Algeria Oman Fertilizers Project) in Singapore. 

 One year on site commissioning support and conduct SAT for Chiyoda Corporation Qatar Gas 3 & 4
Onshore Project in Qatar. 

 Conduct In house test and FAT for Abu Dhabi Gas Industries LTD. (GASCO) HABSHAN-5 JGC
Project in Singapore. 

 Perform In house Test and FAT at factory and completely involve the SAT as well as site
commissioning activities and start up support for the Singapore PAC Natural Gas Project in Exxon
Mobil site in Jurong Island Singapore. 

 Conduct In house test and FAT for Kawasaki Heavy Industries Ltd. Ammonia & Urea Plants in Mary
Project in Singapore. 
Page 5 of 8
Previous Job 4:

Company: PROCESS ANALYTICAL SOLUTIONS PTE. LTD.


No. 11, Woodlands Close,
#09-26, Woodlands 11,
SINGAPORE 737853.
Website: www.pas.com.sg.

Department : Projects / Maintenance

Designation : SENIOR SERVICE ENGINEER

Employment Period : May 2012 to Mar 2015

Total experience : 2 Years 10 Months

Nature of Job:

Carryout the testing and commissioning activities of online process analysers and Integrated Analyser
system Packages.

Major Projects Involved:

Perform Site Acceptance test for two months at Habshan-5 Process Plant for Abu Dhabi Gas
Industries Ltd. (GASCO).

Perform In House Testing and Factory Acceptance test for BARZAN Onshore Project for RASGAS
at ABB Analytical PTE. LTD. SINGAPORE.

Involve in Site Acceptance Test for BARZAN Onshore Project for RASGAS in QATAR around 6
Months.

Perform In House Testing and Factory Acceptance test for ICHTHYS Onshore LNG Facilities
Project for INPEX Australia at ABB Analytical PTE. LTD. SINGAPORE.

Current Job: INSTRUMENT & ANALYTICAL SERVICES PTE. LTD.


111 North Bridge Road,
#21-01,
PENISULA PLAZA,
SINGAPORE-179098
Reg. No. 201317053D
Page 6 of 8
Department : Projects / Maintenance

Designation : SENIOR SERVICE ENGINEER

Employment Period : Mar 2015 to Till Date

Nature of Job:

Carryout the testing and commissioning activities of online process analysers and Integrated Analyser
system Packages.

Major Projects Involved:

Perform In House Testing and Factory Acceptance test for ICHTHYS Onshore LNG Facilities
Project for INPEX Australia at ABB Analytical PTE. LTD. SINGAPORE.

Involve in Site Acceptance Test for BARZAN Onshore Project for RASGAS in QATAR around 9
Months.

Involve in Site Acceptance Test for KHRONE AMADAS at BARZAN Onshore Project Qatar.

Types of process analysers handled:

 COSA 9610 and WIM 990 Wobbe Index 


 ABB Advanced Optima 2000 CEMS analysers, 
 ABB PGC 5000 Analyser with Class B & Class C Ovens.
 ABB Torbar Stack flow meter.
 Ametek Analysers SO2 920, H2S 933, Moisture Analyser OLV 3050. SLR 3050 & 5000,
 Oxygen Analyser 2000 Thermax 
 Emerson Rosemount pH ,Conductivity ,Chlorine, Dissolved Oxygen 5081 Transmitters,
 Rosemount Oxygen Analyser Oxy 4000 / WC 3000 
 Sick Maihak TOC Analyser. 
 Servomax 1100 & 2700C Oxygen Analyser 
 Daniel metering GC 700 from Emerson 
 Honey well XNX & XCD Gas detectors 
 STOLWAY HVAC Systems.
 KHRONE AMADAS System.
 ATAC KVP Analyser.

Page 7 of 8
Personal Profile:
Name : JANAKI RAMA ANJANI PRASAD ALLURI.

Father's Name : DHANA RAJU ALLURI.

Date of Birth : 10th JUNE 1982.

Native Place : TANUKU.

Sex : Male.

Marital Status : Married.

Languages Known : English, Hindi &Telugu (Mother Tongue).

Nationality : Indian.

Religion : Hindu.

Strengths : Hardworking & Troubleshooting skills

Interests : Maintenance, Commissioning, New


Projects & Revamp Projects.

Address in India : S/O A.Dhana Raju,


#04-L2, Sri Lalita Avinash Towers,
Tanuku-534211, West Godavari Dist,
Andhra Pradesh, INDIA.

Relocation: Anywhere in Singapore, India/Abroad.

Declaration: I consider myself familiar with Analytical Instrumentation Aspects. I am also confident on
my ability to work in a team or individual. I hereby declare that the above facts are true to the best of
my knowledge.

Commitment to organization: Given an opportunity I will be able to fit into the slot applied for the
organization with excellent technical skills along with high motivation and exceptional leadership
qualities. I will be able to achieve targets set with very ease with profitability to the organization.

Place: SINGAPORE

Date: 01-MAR-2017 (J.R.A.PRASAD.ALLURI)


Page 8 of 8

Você também pode gostar