SAS-SPL Deviation List for TES-P_107.02, Rev-01

CONSTRUCTION OF DAMMAM HOUSING 380/115/13.8 KV SUBSTATION


BY

2/22/2017

9/10/2017
2/7/2017
DATE
NO.

REVISIONS
DRAWN

BY:- SMS

DATE:- 26-11-2016

CHECKED

BY:- TJN

DATE:- 26-11-2016

OPRG. DEPT

BY

DATE:-

ENG'G. DEPT.

BY:-

DATE:-

CERTIFIED.

BY:-

DATE:- BASE DESIGN


DOCUMENT/DRAWING TITLE INDEX PLANT TOTAL SHEETS REV NO.
THIS DRAWING IS NOT
TO BE USED FOR
CONSTRUCTION OF
SAS-SPL Deviation List for TES-P_107.02, Rev-01
FOR ORDERING
MATERIALS UNTIL
A DA470 PAGE 1 OF 72 5
CERTIFIED AND CONSTRUCTION OF DAMMAM HOUSING 380/115/13.8 KV SUBSTATION
DATED

DAMMAM SAUDI ARABIA CONTRACT NO:- 4400000667 DWG. CONT. SHT.


Table 02-7: Circuit Breaker 380kV

No. Source HMI Alarm Alarm Received At ECC Status JUSTIFICATION

1. Not applicable as per Approved LCC scheme


2. Not applicable as per Approved LCC scheme
3. Not applicable as per Approved LCC scheme
4. Not applicable as per Approved LCC scheme
5. Not applicable as per Approved LCC scheme
1. C.B **** Air pressure low stage-1 6. Not applicable as per Approved LCC scheme
2. C.B **** Air pressure low stage-2
3. C.B **** Air /Oil pressure high 7. Not applicable as per Approved LCC scheme
4. C.B **** Comp. Excessive running
5. C.B **** Nitrogen volume Low **** BREAKER 8. Not applicable as per Approved LCC scheme
C.B 6. C.B **** Oil pump/Air Compressor excessive running ABNORMAL/NORMAL 9. Not applicable as per Approved LCC scheme
****/Isolator 7. C.B **** Pump/Compressor excessive number of starts
1 OR Non Trip 10. Not applicable as per Approved LCC scheme
#### 8. C.B **** Oil Pressure Low Stage-1 Alarm #### ISOLATOR 12. Not applicable as per Approved LCC scheme
Abnormal. 9. C.B **** Oil Pressure Low Stage-2 Alarm ABNORMAL/NORMAL 15. Not applicable as per Approved LCC scheme
10. C.B **** Breaker Lockout Coil defective Alarm 19. Not applicable as per Approved LCC scheme
12. C.B **** Pump Block. 20. Not applicable as per Approved LCC scheme
15. C.B **** Abnormal Alarm 22. Not applicable as per Approved LCC scheme
19. C.B **** Hydraulic Press .Switch alarm 23. Not applicable as per Approved LCC scheme 24. Not
20. C.B **** Closing Spring Faulty. applicable as per Approved LCC scheme
22. C.B **** Compressor/Pump Motor Fail
23. C.B **** Oil level low 24. C.B **** motor
protection Alarm

HMI signals are shifted in **** SF6 GAS


1. C.B ****/ #### GIS SF6 GAS Pressure Low stage1 **** / #### GIS SF6 ALARM/NORMAL group and this group is not required as
2 Non Trip
2. C.B **** / #### GIS SF6 GAS Pressure High ALARM/NORMAL per CDS & OCD comments.
(Add all related sources as applicable)
HMI Signal shifted to LOCKOUT OPERATE group and this
**** / #### GIS SF6 -2 group not required as per CSD OCD meeting.
3 Non Trip
1. C.B **** / #### GIS SF6 GAS Pressure Low stage2. ALARM/NORMAL
(Add all related sources as applicable)
C.B **** Trip Coil-1 4. Not applicable as per Approved LCC scheme
4 5. Not applicable as per Approved LCC scheme
Lock Out
4. C.B **** Trip Coils Lockout by hydraulic oil low **** LOCKOUT 6. Not applicable as per Approved LCC scheme
Non Trip
C.B **** Trip Coil-2 5. C.B **** Low Air stage -2 OPERATE/NORMAL Note: Signal "GIS SF6 GAS PRESS. LOW STAGE-2"
5 6. C.B **** Low Oil stage-2 added in this group as per CSD , OCD Minutes of meeting .
Lock Out

Not applicable as per approved LCC scheme.


C.B **** CB Gas **** SF6 GAS
8 Non Trip
Density High ALARM/NORMAL
1. C.B **** SF6 GAS Density High
(C.B****/ Isolator 4. Cosidered as CB spring charge motor lockout in the CB
14 ####) LCC AC/DC abnormal alarm (SL. No.1)
4. C.B **** /####Spring Charger Motor Supply Fail
Supply Fail ****/#### AC/DC
SUPPLY Non Trip
FAILED/NORMAL
****/#### AC/DC
SUPPLY Non Trip 4. Not applicable as per OPDS.
(C.B****/ Isolator FAILED/NORMAL
15 ####) Protection Panels
Supply Fail
4. C.B **** Protection panels AC Supply Fail
**** POLE DSCRPY Non Trip 4. Combined with DC supply fail as per OPDS
C.B **** Pole
FAULTY/NORMAL
16 Discrepancy Protection
4. C.B **** Pole discrepancy Stage-1 DC MCB Trip/Off
Faulty
3. Not applicable as per approved LCC scheme.
C.B **** Synchro 3. C.B **** Synch check DC MCB Trip/OFF **** SYNC CHK 6. Not applicable as per approved LCC scheme.
18 6. C.B **** R-PH 3Relay DC Supply Fail. Non Trip
Check Relay Faulty FAULTY/ NORMAL 7. Not applicable as per approved LCC scheme.
7. C.B **** R-PH 3Relay Faulty.

3. Combined with DC supply fail as per OPDS


**** CBF protection **** CBF PROT 6. Combined with DC supply fail as per OPDS
21 Non Trip
Faulty 3. C.B **** CBF-1 MCB Trip/OFF FAULTY/NORMAL Note: CBF CT alarms are added in this group as per OCD
6. C.B **** CBF-2 MCB Trip/OFF CSD Minutes of meeting.

**** = Circuit Breaker


#### = Isolator ( Disconnector / Earth Switch)

Table 02-7: Circuit Breaker 115kV


Alarm Received At ECC Status JUSTIFICATION
No. Source
HMI Alarm
1. Not applicable as per Approved LCC scheme
2. Not applicable as per Approved LCC scheme
3. Not applicable as per Approved LCC scheme
4. Not applicable as per Approved LCC scheme
5. Not applicable as per Approved LCC scheme
6. Not applicable as per Approved LCC scheme
1. C.B **** Air pressure low stage-1
2. C.B **** Air pressure low stage-2 7. Not applicable as per Approved LCC scheme
3. C.B **** Air /Oil pressure high
4. C.B **** Comp. Excessive running **** BREAKER 8. Not applicable as per Approved LCC scheme
C.B 9. Not applicable as per Approved LCC scheme
5. C.B **** Nitrogen volume Low ABNORMAL/NORMAL
****/Isolator 10. Not applicable as per Approved LCC scheme
1 6. C.B **** Oil pump/Air Compressor excessive running OR Non Trip
#### 12. Not applicable as per Approved LCC scheme
7. C.B **** Pump/Compressor excessive number of starts #### ISOLATOR
Abnormal. 15. Not applicable as per Approved LCC scheme
8. C.B **** Oil Pressure Low Stage-1 Alarm ABNORMAL/NORMAL
9. C.B **** Oil Pressure Low Stage-2 Alarm 19. Not applicable as per Approved LCC scheme
10. C.B **** Breaker Lockout Coil defective Alarm 21. Not applicable as per Approved LCC scheme
12. C.B **** Pump Block. 22. Not applicable as per Approved LCC scheme
15. C.B **** Abnormal Alarm 23. Not applicable as per Approved LCC scheme 24. Not
19. C.B **** Hydraulic Press .Switch alarm applicable as per Approved LCC scheme
21. C.B **** Spring Charger Motor Fail
22. C.B **** Compressor/Pump Motor Fail
23. C.B **** Oil level low
24. C.B **** motor protection Alarm
HMI signals are shifted in **** SF6 GAS
**** / #### GIS SF6 ALARM/NORMAL group and this group is not required as
2 1. C.B ****/ #### GIS SF6 GAS Pressure Low stage1 Non Trip per CDS & OCD comments.
2. C.B **** / #### GIS SF6 GAS Pressure High ALARM/NORMAL
(Add all related sources as applicable)
HMI signals are shifted in **** SF6 GAS
**** / #### GIS SF6 ALARM/NORMAL group and this group is not required as
2 1. C.B ****/ #### GIS SF6 GAS Pressure Low stage1 Non Trip per CDS & OCD comments.
2. C.B **** / #### GIS SF6 GAS Pressure High ALARM/NORMAL
(Add all related sources as applicable)
HMI Signal shifted to LOCKOUT OPERATE group and this
**** / #### GIS SF6 -2 group is not required as per CSD OCD meeting.
3 Non Trip
1. C.B **** / #### GIS SF6 GAS Pressure Low stage2. ALARM/NORMAL
(Add all related sources as applicable)
4. C.B **** Trip Coils Lockout by hydraulic oil low 4. Not applicable as per Approved LCC scheme
5. C.B **** Low Air stage -2 5. Not applicable as per Approved LCC scheme
C.B **** Trip Coil-1
4 6. C.B **** Low Oil stage-2 6. Not applicable as per Approved LCC scheme
Lock Out

**** LOCKOUT
Non Trip
OPERATE/NORMAL
C.B **** Trip Coil-2
5
Lock Out

Isolator ####
11 #### REMOTE OFF/ON Non Trip Not applicable for 115kV LCC
Control Mode 1. Isolator #### Control Mode Set To OFF Position
2. Isolator #### Control Mode Set To local Position
3. Isolator #### Control Mode Set To BCU Position
4. Isolator #### Control Mode Set To SAS Position
5. Isolator #### Control Mode Authority Set To SAS/ECC
(Add all related sources as applicable)

(C.B****/ Isolator
14 ####) LCC AC/DC 5. C.B **** /####Compressor/Pump Motor Supply Fail
Supply Fail 6. C.B **** /####Control Supply Fail ****/#### AC/DC Not applicable as per LCC scheme.
SUPPLY Non Trip
FAILED/NORMAL 4. Not applicable as per OPDS.
(C.B****/ Isolator
15 ####) Protection Panels
Supply Fail 4. C.B **** Protection panels AC Supply Fail
**** POLE DSCRPY
FAULTY/NORMAL

C.B **** Pole


1. C.B **** Pole discrepancy stage-1 DC Supply Fail
16 Discrepancy Protection Non Trip Not applicable for 115kV LCC.
2. C.B **** Pole discrepancy Stage-1 DC MCB Trip/Off
Faulty
3. C.B **** Pole discrepancy stage- 2 DC Supply Fail
4. C.B **** Pole discrepancy Stage-2 DC MCB Trip/Off
(Add all related sources as applicable)

C.B **** Pole


**** POLE DSCRPY
17 Discrepancy Protection Non Trip Not applicable for 115kV LCC.
OPERATE/ NORMAL
Operated 1. C.B **** Pole discrepancy stage-1 62PD-1Trip
2. C.B **** Pole discrepancy Stage-1 94PD-1 Trip Relay Optd
3. C.B **** Pole discrepancy stage- 2 62PD-2 Trip
4. C.B **** Pole discrepancy 86PD-2 Lock Out Relay Optd
(Add all related sources as applicable)
6. Not applicable as per approved LCC scheme.
C.B **** Synchro **** SYNC CHK 7. Not applicable as per approved LCC scheme.
18 Non Trip
Check Relay Faulty 6. C.B **** R-PH 3Relay DC Supply Fail. FAULTY/ NORMAL
7. C.B **** R-PH 3Relay Faulty.

C.B **** line **** VT


19 Non Trip Not applicable as per approved LCC scheme.
VT fail FAILED /NORMAL
5. C.B **** VT Fuse Fail Alarm
3. C.B **** CBF-1 MCB Trip/OFF
**** CBF protection **** CBF PROT 3. Combined with DC supply fail as per OPDS
21 6. C.B **** CBF-2 MCB Trip/OFF Non Trip
Faulty FAULTY/NORMAL 6. Combined with DC supply fail as per OPDS

**** = Circuit Breaker


####
Table=02-8:
IsolatorFeeder
( Disconnector / Earth
380/230 kV OHL Switch)
& U/G Cable (As Applicable)
Alarm Received At ECC Status JUSTIFICATION
No. Source
HMI Alarm
1. OHL/UG $$$$ FPFM VT Fuse Fail Alarm 1. Not applicable as per OPDS.
OHL/UG 2. Combined with DC supply fail as per OPDS
$$$$ Feeder Protection 2. OHL/UG $$$$ FPFM DC MCB’s Trip/OFF 3. Not applicable as per OPDS.
1
First Main (FPFM) 3. OHL/UG $$$$ FPFM Relay Under Test 4. Not applicable as per OPDS.
Faulty

1. Not applicable as per OPDS.


OHL/UG 1. OHL/UG $$$$ FPSM VT Fuse Fail Alarm 2. Combined with DC supply fail as per OPDS
$$$$ feeder Protection 2. OHL/UG $$$$ FPSM DC MCB’s Trip/OFF 3. Not applicable as per OPDS.
2
Second main (FPSM) 3. OHL/UG $$$$ FPSM Relay Under Test 4. Not applicable as per OPDS.
Faulty

$$$$ LINE PROT


Non Trip
FAULTY/ NORMAL
1. OHL/UG $$$$ Back Up Protection Relays Faulty $$$$ LINE PROT
2. OHL/UG $$$$ Back Up Protection Relays DC Supply Fail. Non Trip
OHL/UG FAULTY/ NORMAL
3 $$$$ Backup Protection 3. OHL/UG $$$$ Back Up Protection Relays DC MCB Trip. Back Up Protection not applicable as per OPDS.
Faulty 4. OHL/UG $$$$ FPSM Relay SAS Communication fail (both
channels)

Note : Line protection CT PROT ALARM/Normal,


PROT Comm. Faulty/Normal signals, INTERTRIP
FAULTY group signals are added in this group as per
CSD OCD requirement and above three groups are not
required.

5. Not applicable as per MC scheme.


OHL/UG Note: Signals Moved in the Line Prot faulty grouped.
$$$$ Feeder Protection $$$$ PROT. COMM
6 Non Trip
First Main (FPFM) FAILED/NORMAL
COMM. Fail 5. OHL/UG $$$$ FPFM Media Converter # faulty.

5. Not applicable as per MC scheme.


OHL/UG Note: Signals Moved in the Line Prot faulty grouped.
$$$$ Feeder Protection
7
Second Main (FPSM)
COMM. Fail 5. OHL/UG $$$$ FPSM Media Converter faulty.

OHL **** Autorecloser 3. OHL **** Auto re-closer # MCB Trip/OFF ****AUTO REC # 3. Combined with DC supply fail as per OPDS
8 Non Trip
Faulty FAULTY/ NORMAL
OHL/UG $$$$ Over
$$$$ OVER VOLT
14 Voltage Non Trip
FAULTY/NORMAL
Protection Faulty 3. OHL/UG $$$$ Over Voltage Prot.MCB Trip/OFF 3. Combined with DC supply fail as per OPDS. Same relay
OHL/UG $$$$ Under used (P142) for both 27 & 59.
$$$$ UNDER VOLT.
15 Voltage Non Trip
ALARM / NORMAL
Protection Faulty Note: Under voltage alarm and undervoltage faulty are kept
OHL/UG $$$$ Under upto HMI as per approved typical SPL.
$$$$ UNDER VOLT.
16 Voltage Non Trip
FAULTY / NORMAL
Protection Faulty 3. OHL/UG $$$$ Under Voltage Prot. MCB Trip/OFF
1. Not applicable as per OPDS OHL scheme.
OHL/UG
$$$$ CABLE DIFF
17 $$$$ Cable Diff 1. OHL/UG $$$$ Cable Differential protection trip Trip 2. Not applicable as per OPDS OHL scheme.
OPERATED/NORMAL
Protection Operated 2. OHL/UG $$$$ Lock Out Relay (86C#) Optd
1. OHL/UG $$$$ Cable Diff. Prot. Relay Faulty.
2. OHL/UG $$$$ Cable Diff. Prot. DC Supply Fail.
3. OHL/UG $$$$ Cable Diff. Prot. MCB Trip/OFF
OHL/UG 4. OHL/UG $$$$ Cable Diff. Prot. CT supervision Alarm $$$$ CABLE DIFF
18 $$$$ Cable Diff 5. OHL/UG $$$$ Cable Diff. Pro. CT supervision faulty Non Trip 1-7. Not applicable as per OPDS OHL scheme.
FAULTY/NORMAL
Protection Faulty 6. OHL/UG $$$$ Cable Diff. Prot. Relay Under Test
7. OHL/UG $$$$ Cable Diff Relay SAS Communication Fail (both
channels)

UG $$$$ CABLE 1. UG $$$$ Cable thermal O/L Protection Trip 1. Not applicable as per OPDS OHL scheme. 2. Not applicable as per O
$$$$ CABLE TH O/L
19 THERMAL O/L PROT. 2. UG $$$$ Lock Out Relay (86 #) Optd Trip
OPERATED/NORMAL
OPERATED
1-4. Not applicable as per OPDS OHL scheme.

UG $$$$ Cable Heat 1. UG $$$$ R-Ph. Cable Heat temp. High Alarm $$$$ CABLE DTCTR
20 Non Trip
Detector Operated 2. UG $$$$ y-ph. Cable Heat temp. High Alarm ALARM / NORMAL
3. UG $$$$ B-ph. Cable Heat temp. High Alarm
4. UG $$$$ Cable thermal O/L Alarm

1. UG $$$$ Cable heat detector system fail 1. Not applicable as per OPDS OHL scheme. 2.
UG $$$$ Cable Heat 2. UG $$$$ Cable heat detector system SAS Communication Fail $$$$ CABLE DTCTR Not applicable as per OPDS OHL scheme.
21 Non Trip
Detector Faulty (both channels) FAULTY / NORMAL

1-5. Not applicable as per OPDS OHL scheme.


1. UG $$$$ Cable thermal O/L Relay Faulty.
2. UG $$$$ Cable thermal O/L DC Supply Fail.
UG $$$$ Thermal O/L 3. UG $$$$ Cable thermal O/L MCB Trip/OFF $$$$ CABLE TH O/L
22 4. UG $$$$ Cable thermal O/L Relay Under Test Non- Trip
Prot. Faulty FAULTY/NORMAL
5. UG $$$$ Cable thermal O/L Relay SAS Communication Fail
(both channels)

3. Not applicable as per OPDS

5. Combined with DC supply fail as per OPDS

6. Not applicable as per OPDS

10. Not applicable as per OPDS


OHL/UG
$$$$ TEE PROT 12. Combined with DC supply fail as per OPDS
24 $$$$ TEE Protection Non- Trip
FAULTY/NORMAL
Faulty
13.Not applicable as per OPDS
3. OHL/UG ($$$$ ) 95TEE-1 CT Supervision Faulty
5. OHL/UG ($$$$ ) 87TEE-1 Protection DC MCB Trip Note: TEE protection CT alarms signals are added in this
6. OHL/UG $$$$) 87TEE-1 Protection Relay under Test. group.
10. OHL/UG ($$$$ ) 95TEE-2 CT Supervision Faulty
12. OHL/UG ($$$$ ) 87TEE-2 Protection DC MCB Trip/Off
13. OHL/UG ($$$$) 87TEE-2 Protection Relay under Test.
15. Not applicable as per OPDS OHL scheme.
OHL/UG
$$$$ Feeder Protection
25
First Main (FPFM)
Operated 15. OHL/UG $$$$ Fast Lock Out Relays 86F # Optd.
$$$$ LINE PROT
Trip
OPERATE/NORMAL 15. Not applicable as per OPDS OHL scheme.
OHL/UG
$$$$ Feeder Protection
26
Second Main (FPSM)
Operated 15. OHL/UG $$$$ Fast Lock Out Relays 86F # Optd.

1,3. Not applicable as per OPDS, only delay intertrip is


OHL/UG applicable.
1. OHL/UG $$$$ FPFM Fast Inter Trip (I/T #) Receive
27 $$$$ First Main Inter
3. OHL/UG $$$$ 85R # Fast Inter Trip Receive Relay Optd
Trip Receive
$$$$ INTRTRIP RECEIVE
Trip
/NORMAL 1,3. Not applicable as per OPDS, only delay intertrip is
OHL/UG applicable.
1. OHL/UG $$$$ FPSM Fast Inter Trip (I/T #) Receive
28 $$$$ Second Main Inter
3. OHL/UG $$$$ 85R # Fast Inter Trip Receive Relay Optd
Trip Receive

1,3. Not applicable as per OPDS, only delay intertrip is


OHL/UG applicable.
29 $$$$ First Main Inter 1. OHL/UG $$$$ FPFM Fast Inter Trip (I/T #) Send
Trip Send 3. OHL/UG $$$$ 85S # Fast Inter Trip Send Relay Optd.
$$$$ INTRTRIP
Trip
SEND/NORMAL
1. OHL/UG $$$$ FPSM Fast Inter Trip (I/T #) Send 1,3. Not applicable as per OPDS, only delay intertrip is
OHL/UG applicable.
3. OHL/UG $$$$ 85S # Fast Inter Trip Send Relay Optd
30 $$$$ Second Main Inter NOTE: this group is kept upto HMI as per OCD
Trip Send requirement .
**** = Breaker Number
$$$$ = Feeder Destination

Table 02-9: Feeder 132/115/110/69 kV OHL & U/G Cable (As Applicable)

JUSTIFICATION

No. Source Alarm Received At ECC Status

HMI Alarm

OHL/UGF 15. Not applicable as per UGC feeder OPDS.


1 $$$$ Feeder Protection
15. OHL/UGF $$$$ Fast Lock Out Relays 94F # Optd.
First Main Operated
$$$$ LINE PROT.
Trip
OPERATE/NORMAL 15. Not applicable as per UGC feeder OPDS.
OHL/UGF
2 $$$$ Feeder Protection
15. OHL/UGF $$$$ Fast Lock Out Relays 94F # Optd.
Second Mainoperated
1. Not applicable as per UGC feeder OPDS.

OHL/UGF 3. Combined with DC supply fail as per OPDS


3 $$$$ Feeder Protection 1. OHL/UGF $$$$ FPFM VT Fuse Fail Alarm
First Main Faulty 3. OHL/UGF $$$$ FPFM Relay DC MCB’s Trip/OFF 6. Not applicable as per OPDS.
6. OHL/UGF $$$$ FPFM Protection Relay Under Test

$$$$ LINE PROT. 1. Not applicable as per OPDS.


Non Trip
FAULTY/ NORMAL 3. Combined with DC supply fail as per OPDS
6. Not applicable as per OPDS.
OHL/UGF Note: Line protection CT alarms, PROT Comm Failed,
4 $$$$ Feeder Protection Intertrip Faulty alarms are moved in this group and CT
Second Main Faulty 1. OHL/UGF $$$$ FPSM VT Fuse Fail Alarm alarms, PROT Comm Failed, Intertrip Faulty groups are not
3. OHL/UGF $$$$ FPSM Relay DC MCB’s Trip/OFF required as per CSD OCD meeting.
6. OHL/UGF $$$$ FPSM Protection Relay Under Test

1,3. Not applicable as per OPDS, only delay intertrip is


OHL/UGF applicable.
5 $$$$ First Main Inter 1. OHL/UGF $$$$ FPFM Fast Inter Trip (I/T #) Receive
Trip Receive 3. OHL/UGF $$$$ 85R # Fast Inter Trip Receive Relay Optd
$$$$ INTRTRIP RECEIVE
Trip
/NORMAL 1,3. Not applicable as per OPDS, only delay intertrip is
OHL/UGF applicable.
$$$$ Second Main Inter
6 1. OHL/UGF $$$$ FPFM Fast Inter Trip (I/T #) Receive
Trip
Receive 3. OHL/UGF $$$$ 85R # Fast Inter Trip Receive Relay optd

OHL/UGF 1,3,4. Not applicable as per OPDS, only delay intertrip is


7 $$$$ First Main Inter 1. OHL/UGF $$$$ FPSM Fast Inter Trip (I/T #) Send
3. OHL/UGF $$$$ 85S # Fast Inter Trip Send Relay Optd applicable.
Trip Send
4. OHL/UGF $$$$ 85S # Delay Inter Trip Send Relay Optd

$$$$ INTRTRIP
Trip
SEND/NORMAL
1,3,4. Not applicable as per OPDS, only delay intertrip is
OHL/UGF applicable.
8 $$$$ Second Main Inter Note: Intertrip send signals are kept upto HMI and this group
Trip Send is not required at PCC as per CSD OCD meeting.
1. OHL/UGF $$$$ FPSM Fast Inter Trip (I/T #) Send
3. OHL/UGF $$$$ 85S # Fast Inter Trip Send Relay Optd
4. OHL/UGF $$$$ 85S # Delay Inter Trip Send Relay Optd

5,7. Not applicable, no media converter for 115kV.


Note: Signals are moved to Prot Faulty group and this group
$$$$ PROT. COMM
9 5. OHL/UGF $$$$ FPFM Media Converter # faulty. is not required at PCC as per CSD OCD meeting.
FAILED/NORMAL
7. OHL/UGF $$$$ FPSM Media Converter # faulty.
OHL/UGF
$$$$ Main protection
(FPFM & FPSM)
Comm. Fail

Non Trip
OHL/UGF
$$$$ Main protection
3,4: Not applicable as per UGC feeder OPDS.
(FPFM & FPSM)
Note: Signals are moved to Prot Faulty group and this group
Comm. Fail
$$$$ INTER TRIP is not required at PCC as per CSD OCD meeting.
10
FAULTY/NORMAL
3. OHL/UGF $$$$ FPFM I/T # DC Supply fail.
4. OHL/UGF $$$$ FPSM I/T # DC Supply fail.
Non Trip 1-4: Not applicable as per UGC feeder OPDS.
1. OHL **** Auto re-closer # faulty
2. OHL **** Auto re-closer # DC Supply Fail
OHL **** Autorecloser 3. OHL **** Auto re-closer # MCB Trip/Off ****AUTOREC #
11
# Faulty 4. OHL **** Auto re-closer Relay # SAS Communication fail FAULTY/ NORMAL
(both channels)

1-4: Not applicable as per UGC feeder OPDS.

OHL **** Autorecloser 1. OHL **** Auto re-closer # Out ****AUTOREC #


12 2. OHL **** Auto re-closer # Blocked
# Blocked BLOCK/DEBLOCK
3. OHL **** Auto re-closer # Abnormal.
4. OHL **** Auto Re-closer # Unsuccessful
1. Not applicable as per UGC feeder OPDS.
OHL **** Autorecloser **** AUTO REC #
13 Non Trip
# Successful SUCCESSFUL/FAILED
1. OHL **** Auto re-closer # Successful
1. UGF $$$$ Cable Differential Relay Trip Trip 1,2: Not applicable as per UGC feeder OPDS.
UGF $$$$ Cable DIFF.
2. UGF $$$$ Lock Out Relay (86C#) Optd $$$$ CABLE DIFF
14 PROT
(Add and segregate all related sources by phase and stages as OPERATED/NORMAL
Operated
applicable)
1. UGF $$$$ Cable Diff. Prot. Relay Faulty.
2. UGF $$$$ Cable Diff. Prot. DC Supply Fail.
3. UGF $$$$ Cable Diff. Prot. MCB Trip/OFF
4. UGF $$$$ Cable Diff. Prot. CT supervision Aalrm.
UGF $$$$ Cable DIFF. 5. UGF $$$$ Cable Diff. Pro. CT supervision faulty $$$$ CABLE DIFF
15 Non Trip 1-8: Not applicable as per UGC feeder OPDS.
Faulty 6. UGF $$$$ Cable Diff. Pro. Function Block FAULTY/NORMAL
7. UGF $$$$ Cable Diff. Prot. Relay Under Test
8. UGF $$$$ Cable Diff. Prot. Relay SAS Communication Fail
(both channels)

UGF $$$$ Cable


$$$$ CABLE TH O/L
16 Thermal O/L Prot. 1. UGF $$$$ Cable thermal O/L Protection Trip Trip 1,2: Not applicable as per UGC feeder OPDS.
OPERATED/NORMAL
Operated 2. UGF $$$$ Lock Out Relay (86#) Optd
(Add and segregate all related sources by phase and stages as
applicable)
1-6: Not applicable as per UGC feeder OPDS.

1. UGF $$$$ Cable thermal O/L. Relay Faulty.


2. UGF $$$$ Cable thermal O/L. DC Supply Fail.
UGF $$$$ Thermal O/L $$$$ CABLE TH O/L
17 3. UGF $$$$ Cable thermal O/L MCB Trip Non Trip
Prot. Faulty FAULTY/NORMAL
4. UGF $$$$ Cable thermal O/L Block
5. UGF $$$$ Cable thermal O/L Relay Under Test
6. UGF $$$$ Cable thermal O/L Relay SAS Communication Fail
(both channels)
(Add all related sources as applicable)
**** = Breaker Number
$$$$ = Feeder Destination
Table 02-10: 33 kV Feeders/Incomers/Tie-Breakers Grouped Alarms
(As applicable in each area, it can be for each feeder individually or grouped alarms for all feeders)

1. **** FPFM Protection VT Fuse Fail


2. **** FPFM Protection Relay Faulty
****First Main 3. **** FPFM Protection DC supply Fail
1
Protection Faulty 4. **** FPFM Protection Relay DC MCB Trip/OFF
5. **** FPFM Protection Relay Under Test
6. **** FPFM Protection SAS Comm. Fail (both channels)
(Add and segregate all related sources as applicable) 33 kV FDR PROT
Non- Trip NA Since we have 13.8kV System
FAULTY/NORMAL
1. **** FPSM Protection VT Fuse Fail
2. **** FPSM Protection Relay Faulty
****Second Main 3. **** FPSM Protection DC supply Fail
2
Protection Faulty 4. **** FPSM Protection Relay DC MCB Trip/OFF
5. **** FPSM Protection Relay Under Test
6. **** FPSM Protection SAS Comm. Fail (both channels)
(Add and segregate all related sources as applicable)

1. **** FPFM Diff. Trip.


2. **** FPFM Dist. Aided Trip.
3. **** FPFM Dist. Z1. Trip.
4. **** FPFM DEF. Aided Trip.
5. **** FPFM Dist. Z2. Trip.
6. **** FPFM Dist. Z3. Trip.
7. **** FPFM Dist. Z4. Trip.
**** First Main 8. **** FPFM Dist. Z5. Trip.
3 9. **** FPFM Dist. SOTF. Trip.
Protection Operated
10. **** FPFM HS. SOTF. Trip.
11. **** FPFM DEF Delay Trip.
12. **** FPFM Back Up O/C Trip.
13. **** FPFM Back Up E/F Trip.
14. **** Trip Relays (94F #) Optd
15. **** Fast Lock Out Relays (86F#) Optd
16. **** Delay Lock Out Relays (86BU) Optd
(Add and segregate all related sources by phase and stages for each
fast and delay trip functions as applicable) 33 kV FDR PROT
Trip NA Since we have 13.8kV System
OPERATED/NORMAL
33 kV FDR PROT
Trip NA Since we have 13.8kV System
OPERATED/NORMAL
1. **** FPSM Diff. Trip.
2. ****FPSM Dist. Aided Trip
3. **** FPSM Dist. Z1. Trip
4. **** FPSM DEF. Aided Trip
5. **** FPSM Dist. Z2. Trip.
6. ****FPSM Dist. Z3. Trip.
7. **** FPSM Dist. Z4. Trip.
8. **** FPSM Dist. Z5. Trip.
**** Second Main 9. ****FPSM Dist. SOTF. Trip.
4
Protection Operated 10. ****FPSM HS. SOTF. Trip.
11. **** FPSM DEF Delay Trip.
12. **** FPSM Back Up O/C Trip
13. **** FPSM Back Up E/F Trip
14. **** Trip Relays (94F # ) Optd
15. **** Fast Lock Out Relays (86F#) Optd
16. **** Delay Lock Out Relays (86BU) Optd
(Add and segregate all related sources by phase and stages for each
fast and delay trip functions as applicable)

1. **** FPFM CH-1 Communication Fail


**** Main Protection 2. **** FPFM CH-2 Communication Fail
33 kV PROT.COMM
5 (FPFM & FPSM) 3. **** FPSM CH-1 Communication Fail Non trip NA Since we have 13.8kV System
FAILED/NORMAL
Comm. Fail 4. **** FPSM CH-2 Communication Fail
5. **** FPFM Media Converter # Faulty
6. **** FPFM Media Converter # DC Supply Fail.
7. **** FPSM Media Converter # Faulty.
8. **** FPSM Media Converter # DC Supply Fail. (Add and
segregate all related sources as applicable)
1. **** FPFM Communication Fail (both channels)
**** Main Protection 2. **** FPSM Communication Fail (both channels)
33 kV INTERTRIP
6 (FPFM & FPSM) 3. **** FPFM I/T # DC Supply fail. Non trip NA Since we have 13.8kV System
FAULTY/NORMAL
Intertrip. Fail 4. **** FPSM I/T # DC Supply fail.
(Add and segregate all related sources as applicable)

**** First Main Inter 1. **** FPFM Fast Inter trip ( I/T # ) Receive
7 NA Since we have 13.8kV System
Trip Receive 2. **** FPFM Delay Inter Trip ( I/T # ) Receive
3. **** 85R # Fast Inter Trip Receive Relay Optd
4. **** 85R # Delay Inter Trip Receive Relay Optd (Add and 33 kV INTRTRIP
Trip
segregate all related sources as applicable) RECEIVE/NORMAL

1. **** FPSM Fast Inter trip ( I/T # ) Receive


**** Second Main 2. **** FPSM Delay Inter trip ( I/T # ) Receive
8 3. **** 85R # Fast Inter Trip Receive Relay Optd. NA Since we have 13.8kV System
Intertrip Receive
4. **** 85R # /Delay Inter Trip Receive Relay Optd (Add and
segregate all related sources as applicable
**** First Main Intertrip 1. **** FPFM Fast Inter Trip ( I/T # ) Send
9 NA Since we have 13.8kV System
Send 2. **** FPFM Delay Inter Trip ( I/T # ) Send
3. **** 85S # Fast Inter Trip Send Relay Optd
4. **** 85S # Delay Inter Trip Send Relay Optd (Add and segregate
all related sources as applicable)

33 kV INTRTRIP SEND
Trip
/NORMAL

**** Second Main Inter


10 NA Since we have 13.8kV System
Trip Send
1. UGF **** FPSM Fast Inter Trip ( I/T # ) Send
2. UGF **** FPSM Delay Inter Trip ( I/T # ) Send
3. UGF **** 85S # Fast Inter Trip Send Relay Optd
4. UGF **** 85S # Delay Inter Trip Send Relay Optd (Add and
segregate all related sources as applicable)

1. **** Trip Circuit-1 Faulty


33 kV TRIP CKT FAULTY
11 **** Trip CKT Faulty 2. **** Trip Circuit -2 Faulty Non- Trip NA Since we have 13.8kV System
/NORMAL
3. **** Trip Circuit-1 DC Supply Fail
4. **** Trip Circuit-2 DC Supply Fail
(For all 33 kV (CAP, INC, BS, OGF& Aux. TRF)
Add and segregate all related sources as applicable )

1. **** BCU Faulty 33 kV BCU FAULTY


12 ****BCU Faulty Non- Trip NA Since we have 13.8kV System
2. **** BCU DC Control supply Fail /NORMAL
3. **** BCU DC supply fail
4. **** BCU DC MCB Trip/OFF.
5. **** BCU SAS Communication fail (both channels) (For all
33kV (CAP, INC, BS , OGF Aux. TRF) Add and segregate all
related sources by phase and stages for each function as applicable )

C.B **** SF6 GAS 1. **** SF6 GAS PRESS. LOW ST-1 Alarm 33kV SF6 GAS
13 Non trip NA Since we have 13.8kV System
Pressure Low ST-1 ((For all 33 kV (CAP, INC, BS, OGF & Auxl.TRF) add and ALARM/NORMAL
segregate all related sources by phase and stages for each function
as applicable )
1. **** SF6 GAS PRESS. LOW ST-2 Alarm.
C.B **** SF6 GAS 2. **** Locked Out. 33kV C.B LOCKEDOUT
14 Non trip NA Since we have 13.8kV System
Pressure Low ST-2 3. **** Spring Not Charge OPERATE /NORMAL
((For all 33 kV (CAP, INC, BS, OGF & Auxl.TRF) add and
segregate all related sources by phase and stages for each function as
applicable)

**** CBF Protection 1. **** CBF protection Trip 33kV CBF PROT
15 2. **** 86CBF Lock Out optd Trip NA Since we have 13.8kV System
Operated OPERATE/NORMAL
((For all 33 kV ( CAP, INC,BS OGF & Auxl.TRF) add and
segregate all related sources by phase and stages for each function
as applicable )

1. **** VT Fuse Failure Alarm


2. **** VT Main MCB Trip
BUS/OGF 33kV VT
16 3. **** VT branches MCB Trip Non- Trip NA Since we have 13.8kV System
**** VT Fail FAILED/NORMAL
4. **** VT Rack Out
(Add and segregate all related sources for bus and OG- feeders VTs
as applicable )

1. C.B **** Comp. Excessive running


2. C.B **** Pump/Compressor excessive number of starts
3. C.B **** Breaker Lockout Coil defective Alarm
4. C.B **** Operating Mechanism Fail
5. C.B **** Pump Block. 33kV BREAKER
17 C.B **** Abnormal. 6. C.B **** Motor Running Time Exceeded. Non Trip NA Since we have 13.8kV System
ABNORMAL/NORMAL
7. C.B **** Spring Charger Motor Lockout
8. C.B **** Abnormal Alarm
9. C.B **** Closing lockout Alarm.
10. C.B **** Hydraulic Press .Switch alarm
11. C.B **** Closing Spring Faulty.
12. C.B **** Spring Charger Motor Fail
13. C.B **** Compressor/Pump Motor Fail
14. C.B **** motor protection Alarm
15. C.B **** DS’s motor running time exceeded.
16. C.B **** ES’s motor running time exceeded. (Add all related
sources as applicable)

C.B ****GIS Gas 1. C.B ****/ #### GIS SF6 GAS Pressure Low stage1 33kV GIS SF6
18 Non Trip NA Since we have 13.8kV System
Pressure 2. C.B **** / #### GIS SF6 GAS Pressure High (Add all related ALARM/NORMAL
sources as applicable)
C.B **** GIS Gas 1. C.B **** / #### GIS SF6 GAS Pressure Low stage2. (Add all 33kV GIS SF6 -2
19 Non Trip NA Since we have 13.8kV System
Pressure related sources as applicable) ALARM/NORMAL

1. **** Auto Re-closer relay operation blocked


2. **** Auto Re-closer relay abnormal
**** Autorecloser ****AUTOREC
20 3. **** Auto Re-closer Unsuccessful Non- Trip NA Since we have 13.8kV System
Blocked BLOCK/DEBLOCK
4. **** Auto re-closer selector Out of service
5. **** Auto re-closer Relay SAS Communication Fail (both
channels)
(Add all related sources as applicable)

1. ****Auto Re-Closer Relay Faulty


**** Autorecloser 2. **** Auto Re-Closer DC Supply Fail **** AUTO REC
21 Non- Trip NA Since we have 13.8kV System
Faulty 3. **** Auto Re-Closer DC MCB Trip (Add all related sources as FAULTY/NORMAL
applicable)

OHL**** Auto Recloser **** AUTO REC


22 1. OHL **** Auto re-closer successful ( Add all related sources as Non Trip NA Since we have 13.8kV System
Successful SUCCESSFUL /FAILED
applicable)
1. **** Control Mode Selected to OFF.
2. **** Control Mode Selected to LOCAL.
**** Control Mode 3. **** Control Mode Selected to BCU.
23 **** REMOTE OFF / ON Non Trip NA Since we have 13.8kV System
Remote OFF 4. **** Control Mode Selected to SAS.
5. **** Control Mode Authority Set toSAS/ECC (Add all related
sources as applicable )

1. 33 kV Auxiliary Transformer # Protection Trip


AUX TRF # 2. 220 V Auxiliary Transformer # Protection relay (REF & 50N)
24 NA Since we have 13.8kV System
Protection Operated Trip
3. 33 kV Auxiliary Transformer # Trip Relays (94 #) Optd
4. 33 kV Auxiliary Transformer # Lock Out Relays (86
AUX T # PROT
#) Optd Trip
OPERATE/NORMAL
(Add all related sources by phase and stages for each function as
applicable )

1. 33 kV Auxiliary Transformer # Buchholz Stage-2


AUX TRF #
25 2. 33 kV Auxiliary Transformer # Winding temperature Stage-2 NA Since we have 13.8kV System
Buchholz ST-2
Trip
(Add all related from all mechanical protection trip signals sources
as applicable )
AUX TRF # 1. 33 kV Auxiliary Transformer # Protection relays Faulty AUX T # PROT
26 Non Trip NA Since we have 13.8kV System
Protection Faulty 2. 33 kV Auxiliary Transformer # Protection DC Supply Fail FAULTY/NORMAL
3. 33 kV Auxiliary Transformer # Protection Relays DC MCB Trip.
4. 33 kV Auxiliary Transformer # protection relays SAS
Communication fail (both channels)
(Add all related sources as applicable)

1. 33 kV RMU # O/C Protection Alarm


2. 33 kV RMU # Earth Leakage Alarm
3. 33 kV Auxiliary Transformer # oil Level High Alarm
AUX TRF # 4. 33 kV Auxiliary Transformer # oil Level Low Alarm AUX T # TRANS
27 5. 33 kV Auxiliary Transformer # Pressure Relief Alarm Non Trip NA Since we have 13.8kV System
Alarm ALARM/NORMAL
6. 33 kV Auxiliary Transformer # oil Temperature High Stage-1
Alarm
7. 33 kV Auxiliary Transformer # oil Temperature High stage-2
Alarm
8. 33 kV RMU # Faulty
(Add all related mechanical protection alarm signals sources as
applicable )

AUX TRF # AUX T # BUCHHOLZ ST-


28 1. 33 kV Auxiliary Transformer # Buchholz Stage-1 Alarm Non Trip NA Since we have 13.8kV System
Buchholz ST-1 1 ALARM/NORMAL
(Add all related sources as applicable)

AUX TRF #
AUX T # WDG TEMP ST1
29 Winding Temperature 1. 33 kV Auxiliary Transformer # Winding temperature Stage-1 Non Trip NA Since we have 13.8kV System
Alarm ALARM/NORMAL
High Stage-1
(Add all related sources as applicable )
**** = Breaker Number
Table 02-11: 13.8 kV Feeders/Incomers/Tie-Breakers Grouped Alarms
2. Not applicable, our all feeders are plain OG.
**** Protection Relay 13.8kV BCPU FAULTY
2 2. **** diff Relay Faulty ( in case of Consumer FDR) Non- Trip
Faulty /NORMAL

2. Not applicable, our all feeders are plain OG.


3. Not applicable, our all feeders are plain OG.
**** Protection Relay 2. **** diff. protection OPTD ( in case of Consumer FDR) 13.8kV PROT
3 3. **** Trip Relays (94# ) Optd Trip
Operated OPERATE/NORMAL

C.B **** SF6 GAS 1. **** SF6 GAS PRESS. LOW ST-1 Alarm 13.8kV SF6 GAS
5 ((For all 13.8 kV (CAP, INC, BS, OGF, Consumer FDR & Non- Trip 1. Not applicable, CB is vaccum type.
Pressure Low ST-1 ALARM/NORMAL
Auxl.TRF) Add and segregate all related sources by phase and
stages for each function as applicable )
1. **** SF6 GAS PRESS. LOW ST-2 Alarm.
C.B **** SF6 GAS 13.8kV C.B LOCKEDOUT 1,2: Not applicable, CB is vaccum type.
6 2. **** Locked Out. Non- Trip
Pressure Low ST-2 OPERATE /NORMAL

1. **** AC Supply Fail 1. Not applicable as per OPDS, AC MCB trip is considered.
9 **** AC Supply failure

1. 13.8 kV Remote End Push Button 13.8kV REMOTE TRIP


11 2. 13.8 kV Local End Auxiliary Relay Optd RECEIVE/NORMAL Not applicable as per OPDS.
Add and segregate all related sources by stages for each function as If Applicable
applicable

1. OHL **** Auto Re-close relay operation Blocked


OHL **** Autorecloser 2. OHL **** Auto Re-close relay abnormal **** AUTOREC
12 Non Trip Not applicable, our all feeders are plain OG.
Blocked 3. OHL **** Auto Re-closer selector Out BLOCK/DEBLOCK
4. OHL **** Auto Re-closer Un Successful (Add all related sources
as applicable)

1. OHL **** Auto Re-close Relay Faulty


2. OHL **** Auto Re-close MCB Trip/Off
OHL **** Autorecloser **** AUTO REC FAULTY
13 3. OHL **** Auto Reclose DC Supply Fail Non Trip Not applicable, our all feeders are plain OG.
Faulty /NORMAL
4. OHL **** Auto Reclose relay SAS Communication fail (both
channels)
(Add all related sources as applicable)

OHL **** Autorecloser **** AUTO REC


14 1. OHL # Auto re-closer successful Non Trip Not applicable, our all feeders are plain OG.
Successful SUCCESSFUL/ FAILED
( Add all related sources as applicable)

3. 13.8 kV Auxiliary Transformer #Winding Temperature Stage-2


AUX TRF # Trip 5. 13.8 kV AUX T # PROT
16 Trip 3,5. Not applicable as per SST LCP scheme.
Protection Operated Auxiliary Transformer # Trip Relays (94#) Optd OPERATE/NORMAL

2. Not applicable as per scheme


3. Not applicable as per scheme
AUX TRF # 2. 13.8 kV Auxiliary Transformer # Protection DC Supply Fail AUX T # PROT.
18 3. 13.8 kV Auxiliary Transformer # Protection Relay DC MCB Non Trip
Protection Faulty FAULTY/NORMAL
Trip.

1. 13.8 kV RMU # O/C Protection Alarm


AUX TRF # 2. 13.8 kV RMU # Earth Leakage Alarm AUX T # TRANS PROT.
19 8. 13.8 kV RMU # Faulty Non Trip RMU not available in SS
Alarm ALARM/NORMAL

Non Trip
AUX TRF #
AUX T # WDG TEMP ST1
21 Winding Temperature Not applicable as per SST scheme
ALARM/NORMAL
High Stage-1 1. 13.8 kV Auxiliary Transformer # Winding Temperature Stage-1
Alarm
**** = Breaker Number
# = Equipment Number
Table 02-12: 380/230: 132:115:110 kV & 230/69 kV Transformers (As Applicable)
380 kV

SGT # SET-1
1 1,2, 5: Not applicable as per OPDS.
Diff.Protection Faulty 1. SGT # SET-1 CT Supervision (95T-1) Alarm
2. SGT # SET-1 CT supervision (95T-1) Faulty
5. SGT # SET-1Diff. protection (87T-1) Under Test SGT or TR #
PROTECTION Non Trip
FAULTY/NORMAL

1,2, 5: Not applicable as per OPDS.


SGT # SET-2
2 Note: Transformer Protection CT alarms are added in this
Diff.2Protectio n Faulty 1. SGT # SET-2 CT Supervision (95T-2) Alarm
2. SGT # SET-2 CT supervision (95T-2) Faulty group as per OCD, CSD meeting.
5. SGT # SET-2Diff. protection (87T-2) Under Test

SGT or TR #
SGT #
4 BUCHHOLZST1 ALARM Non Trip Not applicable as per TFR LCP scheme.
Buchholz Stage-I
/NORMAL
2. SGT # OLTC Protective Relay # Stage-1 Alarm
Not applicable as per TFR LCP scheme.
Applicable in 380kV
SGT # Oil
8
Level Low Alarm
2. SGT # Main Tank -2 oil level low Alarm
Applicable in 380kV
Not applicable as per TFR LCP scheme.
SGT # Oil
9 2. SGT # Main Tank -2 oil level high Alarm
Level High Alarm

SGT # Pressure Relief Not applicable as per TFR LCP scheme.


10
Operated 3. SGT # Oil Chamber pressure Relief Device
SGT or TR #
TRANSFORMER Non Trip
ALARM/NORMAL

SGT # TRF
11 Gas Detector (Air Seal) 1. SGT # Main Tank GAS Detector -1 (Air Seal)Alarm Not applicable as per TFR LCP scheme.
Alarm 2. SGT # Main Tank GAS Detector -2 (Air Seal)Alarm
3. SGT # Buchholz for conservator Stage -1 Alarm
4. SGT # Buchholz for conservator Stage -2 Alarm (Add all related
sources as applicable)

SGT # Cooling System Not applicable, cooler system control mode in manual
13
Faulty 3. SGT # Cooler System Control mode in LOCAL considered.
2,3: No separate alamrs available as per scheme. OLTC
2. SGT # OLTC Motor Circuit Alarm motor drive failure considered. 11,12: AVC
3. SGT # OLTC Motor Supply Fail SGT or TR # TAP
SGT # Tap relay DC supply & control supply are same.
15 11. SGT # AVC Control Supply Fail. CHANGER Non- Trip
Changer Faulty
12. SGT # AVC Voltage Supply Fail FAULTY/NORMAL
18. SGT # OIL Filter Pump Zero oil flow
Note : Signal is shifted to AVC faulty / Tap changer Faulty
SGT or TR # group as per OCD CSD meeting. So this group is not
17 TAPCHANGER Non- Trip available.
INCOMPLETE/NORMAL

Not applicable as per TFR LCP scheme.


SGT# Fire Protection SGT or TR # FIRE PROT
21 1. SGT# Fire Protection Operated (Add all related sources as Non Trip
Operated OPERATE/NORMAL
applicable)
Not applicable as per TFR LCP scheme.
SGT# Fire Protection SGT or TR # FIRE PROT
22 1. SGT# Fire Protection Faulty Non Trip
Faulty FAULTY/NORMAL
(Add all related sources as applicable)
5. 64-1 (REF) relay for tertiary not available as per OPDS
5. SGT # Tertiary REF Protection (64-1)Trip SGT or TR #
SGT # SET -1 & SET- 2 17. SGT # Oil Chamber pressure Relief Device Trip (If Applicable 17. Not applicable as per TFR LCP scheme.
23 PROTECTION Trip
Protection Operated )
OPERATE/NORML

SGT or TR # TEE PROT Non- Trip


FAULTY/NORMAL
SGT # SET-1 TEE
26 3,5: Not applicable as per OPDS.
Protection Faulty 3. SGT # SET-1 CT Supervision (95TEE-1) Faulty
5. SGT # SET-1 TEE Protection Relay (87TEE-1) Under Test

3,5: Not applicable as per OPDS.


SGT #SET-2 TEE SGT or TR # TEE PROT Note: TEE Protection CT alarms are added in this group as
27 Non- Trip
Protection Faulty 3. SGT # SET-2 CT Supervision (95TEE-2) Faulty FAULTY/NORMAL per OCD, CSD meeting.
5. SGT # SET-2 TEE Protection Relay (87TEE-2) Under Test

SGT # (HV/LV) VT 6. SGT # LV VT fuse failed Alarm SGT or TR # VT


28 Non- Trip Not applicable as per LCC scheme.
Fail FAIL/NORMAL
LV 132/115/110 kV
SGT # LV
SGT or TR # LV PROT
29 SET-1 Cable Protection 5. SGT # SET-1 LV Cable Diff. protection 87C-1 Relay under Test. Non- Trip Not applicable as per OPDS.
FAULTY/NORMAL
Faulty

SGT # LV
30 SET-1 Cable Protection 4. SGT # SET-2 LV CT Supervision Relay 95-CT2 faulty 4,5: Not applicable as per OPDS.
Faulty 5. SGT # SET-2 LV Cable Diff. protection 87C-2 Relay under Test.
SGT or TR # LV PROT
Non- Trip
FAULTY/NORMAL Combined with relay Dc supply fail as per OPDS.
SGT # LV
31 Backup Protection
Faulty 2. SGT # LV ( 50P/51P) Relay DC MCB Trip/Off
SGT # LV
32 SET-1 Cable Protection 2. SGT # LV 94C-1 Trip Relay Optd.
Operated SGT or TR # LV
PROTECTION Trip Not applicable as per OPDS.
SGT # LV OPERATE/NORMAL
33 SET-2 Cable Protection 2. SGT #LV 94C-2 Trip Relay Optd
Operated
# = Equipment Number
Table 02-13: 132:115:110/33 kV or 132:115:110 /13.8 kV Transformers (As Applicable)
No. Source HMI Alarm Alarm Received At ECC Status JUSTIFICATION

GT # Main Transformer
3 Not applicable as per GT LCP scheme.
Oil Temperature High

3. GT # OLTC Oil Temperature High Stage-1 Alarm


4. GT # OLTC Oil Temperature High Stage-2 Alarm
GT or TR #
TRANSFORMER Non Trip
GT #
5 3. GT # Cooler System Control mode in LOCAL ALARM/NORMAL Not applicable as per GT LCP scheme.
Cooler Fail
4. GT # Fan MCB Trip/OFF
7. GT # Fans Stand By AC Power Supply Fail

GT # TRF Gas
6 Detector ( Air Seal) 2. SGT # Buchholz for conservator (Air Seal) Stage-1 Alarm Not applicable as per GT LCP scheme.
Alarm 3. GT # Main Conservator Tank Buchholz Stage-1 Alarm
4. GT # Main Conservator Tank Buchholz Stage-2 Alarm

GT # Winding Not applicable as per GT LCP scheme, it is two winding


GT or TR # WDG TEMP
8 Temperature High Stage- 3. GT #Tertiary Winding Temperature High Stage-I Alarm. Non Trip transformer.
ST1 ALARM/NORMAL
1
3. Combined with DC supply fail as per OPDS. 4,5:
Not applicable as per OPDS.
GT # SET-1 3. GT # SET-1 protection MCB Trip
10
Protection Faulty 4. GT # SET-1 CT supervision (95T-1) Alarm
5. GT # SET-1 protection Relay (87T-1) under Test. GTor TR # PROTECTION
Non- Trip
FAULTY/NORMAL
3. GT # SET-2 protection MCB Trip 3. Combined with DC supply fail as per OPDS. 4,5:
GT # SET-2 4. GT # SET-2 CT supervision (95T-2) Alarm Not applicable as per OPDS.
11
Protection Faulty 5. GT # SET-2 protection Relay (87T-2) under Test.

GT # Winding Not applicable as per GT LCP scheme, it is two winding


GT or TR#WDG TEMP transformer.
12 Temperature High Stage- 3. GT # Tertiary Winding Temperature High Stage-2 Trip Trip
ST2 OPERATE/NORMAL
2
Not applicable as per GT LCP scheme.

GT# Fire Protection GT or TR # FIRE PROT.


15 Non Trip
Operated OPERATE/NORMAL

1. GT# Fire Protection Operated (Add all related sources as


applicable)
Not applicable as per GT LCP scheme.
GT# Fire Protection GT or TR # FIRE PROT.
16 1. GT# Fire Protection Faulty Non Trip
Faulty FAULTY/NORMAL
(Add all related sources as applicable)
GT # Not applicable as per GT LCP scheme.
GTor TR# PROTECTION
19 Mechanical Protection 1. GT # Rapid Pressure Trip TRIP
OPERATED/NORMAL
Trip
2. GT # OLTC Motor Circuit Aarm
14. GT # OIL Filter Pump Faulty GTor TR# AVC Faulty
21 GT#Tap Changer Faulty 15. GT # Oil Filter Pump MCB Trip. Non Trip Not applicable as per GT MDU scheme.
FAILED/NORMAL
16. GT # Oil Filter pump Zero oil Flow

Not applicable as per LCC scheme.


GT# (HV/LV) GT or TR # VT
22 Non- Trip
VT Failed 1. GT # HV VT fuse failed Alarm FAILED/NORMAL

# = Equipment Number
Table 02-14: 33/13.8 kV Transformers
No. Source HMI Alarm Alarm Received at ECC Status JUSTIFICATION
T or TR # Transformer 2. T or TR # Tap changer oil level low Alarm.
2
Alarm T or TR# TRANSFORMER
Non Trip
T or TR # Control ALARM/NORMAL
3
Supply Fail 3. T or TR # Fans Supply MCB Off
1. T or TR # Transformer Winding Temperature High Stage -1 Non Trip
T or TR # WDG. Temp Tor TR#WDG. TEMP.ST1
4 Alarm.
High Stage-1 ALARM/NORMAL
(Add all related sources as applicable)
Trip
T or TR # WDG. Temp. T or TR# WDG.TEMP.
5 1. T or TR # winding temperature stage 2 Trip (Add all related
High Stage-2 ST2 OPERATE/NORMAL
sources as applicable)
1. T or TR # HV protection supply supervision Alarm.
2. T or TR # HV protection MCB TRIP/Off
T or TR # HV 3. T or TR # HV protection Relays Faulty.
6
Protection Supply Fail 4. T or TR # HV protection Relays under Test.
5. T or TR # HV protection Relays SAS Communication fail (both
channels) NOT APPLICABLE AS PER SOW
(Add all related sources as applicable)
T or TR# PROTECTION
Non Trip
FAULTY/NORMAL
NOT APPLICABLE AS PER SOW
T or TR# PROTECTION
Non Trip
FAULTY/NORMAL
1. T or TR # LV protection supply supervision Alarm.
2. T or TR # LV protection MCB Trip/Off
T or TR # LV 3. T or TR # LV protection Relays Faulty.
7
Protection Supply Fail 4. T or TR # LV protection Relays Under Test
5. T or TR # LV protection Relays SAS Communication fail (both
channels)
(Add all related sources as applicable)
T or TR # Fire 1. T or TR # Fire Protection Operated (Add all related sources as T or TR # FIRE PROT Non Trip
8
Protection Operated applicable) OPERATE/NORMAL
Non Trip

T or TR # Fire T or TR # FIRE PROT


9
Protection Faulty FAULTY/NORMAL
1. T or TR # Fire Protection Faulty (Add all related sources as
applicable)
NOT APPLICABLEAS PER PTS
T or TR # Diff. Protn. 1. T or TR # Differential protection (87T) Trip (Add and segregate
10
OPTD all related sources by phase and stages for each trip functions as
applicable)

T or TR # E/F REF.
11 1. T or TR # Restricted Earth Fault REF (64S) Trip (Add and
OPTD
segregate all related sources as applicable)

T or TR # HV
12 O/C & E/F Protection 1. T or TR # HV Over Current and Earth Fault Protection Trip
OPTD (Add and segregate all related sources by phase for each stage as
applicable) T or TR# PROTECTION
Trip
OPERATE/NORMAL
T or TR # Stand by E/F
13
Protection Optd 1. T or TR # Stand by Earth Fault Protection Trip (Add and
segregate all related sources as applicable)

T or TR # LV
14 O/C&E/F Protection 1. T or TR # LV Over Current and Earth Fault Protection Trip
Optd (Add and segregate all related sources by phase and Stages for each
functions as applicable)

T or TR # Buchholz
15
Stage-2 1. T or TR # Main Tank Buchholz Stage -2 Trip. (Segregate all
related sources as applicable)
# = Transformer Number
Table 02-15: Reactors
3. Combined with set-1 DC supply fail as per OPDS. 4.
Reactor # First Main 3. Reactor # SET-1 protection relay MCB Trip Not applicable as per OPDS.
1 4. Reactor # SET-1 protection Under Test.
Protection Faulty

3. Reactor # SET-2 protection Relay MCB Trip 3. Combined with set-1 DC supply fail as per OPDS. 4.
Reactor # Second Main Not applicable as per OPDS.
2 4. Reactor # SET-2 protection Relay under Test.
Protection Faulty
R # PORT
Non Trip
FAULTY/NORMAL
Reactor # SET-2 2. Reactor # SET-2 CT supervision relay (95CT-2) Faulty R # PORT Not applicable as per OPDS.
4 Non Trip
Protection Faulty FAULTY/NORMAL
3: Combined with Back up Protection (50N/51N) DC supply
fail. 4. Not
Reactor # Backup 3. Reactor # Backup Protection (O/C &E/F) Relay DC MCB Trip applicable as per OPDS.
5
protection Faulty 4. Reactor # Backup Protection (O/C &E/F) Relay Under Test

Not applicable as per reactor LCP drawing.

R # REACTOR
9 Reactor # Faulty Non Trip
ALARM/NORMAL

6. Reactor # Cooling System Fail

Not applicable as per reactor LCP drawing.


Reactor # Rapid R # PROT
14 Trip
Pressure OPERATE/NORMAL
1. Reactor # rapid pressure Trip

R # FIRE PROT. Non Trip


Reactor # Fire OPERATE/NORMAL
17
Protection Operated 1. Reactor # Fire Protection Operated (Add all related sources as
applicable) Not applicable as per reactor LCP drawing.
R # FIRE PROT. Non- Trip
Reactor # Fire FAULTY/NORMAL
18 1. Reactor # Fire Protection Faulty (Add all related sources as
Protection Faulty
applicable)
# = Reactor Number
Table 02-16: Bus with Bus Bar Protection 380/230/132/115/110/69kV (As Applicable)
3. B.B 1A CT Bus Wire Supervision Faulty
7. B.B 1A Bay Unit Error
8. B.B 1A Bay Unit DC Supply Fail
Bus Bar Zone-1A 9. B.B 1A Bay Unit Communication Fail (both channels) BUS-1A BUSBAR PROT
1 Non Trip Not applicable as per OPDS
Protection Faulty 10. B.B 1A Protection Relay Under Test. FAULTY/NORMAL

3. B.B 1B CT Bus Wire Supervision Faulty


7. B.B 1B Bay Unit Error
Bus Bar Zone-1B BUS-1B BUSBAR PROT
2 8. B.B 1B Bay Unit DC Supply Fail Non Trip Not applicable as per OPDS
Protection Faulty FAULTY/NORMAL
9. B.B 1B Bay Unit Communication Fail (both channels)
10. B.B 1B Protection Relay under Test.
3. B.B 2A CT Bus Wire Supervision Faulty
7. B.B 2A Bay Unit Error
Bus Bar Zone-2A 8. B.B 2A Bay Unit DC Supply Fail BUS-2A BUSBAR PROT
3 Non Trip Not applicable as per OPDS
Protection Faulty 9. B.B 2A Bay Unit Communication Fail (both channels) FAULTY/NORMAL
10. B.B 2A Protection Relay under test

3. B.B 2B CT Bus Wire Supervision Faulty


Bus Bar Zone-2B 7. B.B 2B Bay Unit Error BUS-2B BUSBAR PROT
5 8. B.B 2B Bay Unit DC Supply Fail Non Trip Not applicable as per OPDS
Protection Faulty FAULTY/NORMAL
9. B.B 2B Bay Unit Communication Fail (both channels)
10. B.B 2B Protection Relay under test.
(Add all related sources as applicable)
3. B.B check zone CT supervision Faulty
Bus Bar Protection BB CHK. ZONE PROT
6 7. B.B check zone Protection Relay under test. Non Trip Not applicable as per OPDS
Check Zone Faulty FAULTY/NORMAL

5. BB * Under Voltage Alarm


6. BB * VT Fuse Fail Alarm BB * VT
15 Bus Bar * VT Failed 7. BB * Under Voltage relay faulty Non Trip Not applicable as per LCC scheme
FAILED/NORMAL
8. BB * Under Voltage relay DC supply fail

1. Bus Bar * GIS SF6 Gas Pressure Low Stage1


Bus bar * Gas Pressure BUS * GIS SF6
16 2. Bus Bar * GIS Gas Pressure High (Add all related sources as Non Trip
Alarm ALARM/NORMAL
applicable) The same already considered with bus disconnector section
group in 380kV & BC section in 115kV.
Bus bar * Gas Pressure BUS * GIS SF6ST2
17 1. Bus Bar * GIS Gas Pressure Low Stage-2 (Add all related sources Non Trip
Low Stage-2 ALARM/NORMAL
as applicable)

1. Bus Bar * protection faulty


2. Bus Bar * CT Bus wire supervision Alarm.
3. Bus Bar * CT Bus wire supervision Faulty.
Mesh Corner Protection 4. Bus Bar * Interpose relay faulty MESH COR * PROT
18 Non Trip
Faulty 5. Bus Bar * DC Supply Fail FAULTY/NORMAL
6. Bus Bar * CT Bus wire shorting operated one for Each mesh
corner
Not Applicable as per PTS
7. Bus Bar * protection under test.
8. Bus Bar * protection SAS Communication fail (both channels)
(Add all related Sources as applicable)

Mesh Corner Protection MESH COR * PROT


19 Trip
Operated 1. Mesh corner protection one for each mesh corner Trip OPERATE/NORMAL
(Add and segregate all related sources by phase from each mesh
corner as applicable)
33 kV Single Bus bar type Substations

No. Source Alarm Received At ECC Status


HMI Alarm
1. Bus Bar * protection faulty
2. Bus Bar * CT Bus wire supervision Alarm.
3. Bus Bar * CT Bus wire supervision Faulty.
Bus Bar * Protection 4. Bus Bar * Interpose relay faulty BUSBAR * PROT
20 Non Trip Not Applicable as per PTS.
Faulty 5. Bus Bar * DC Supply fail FAULTY/NORMAL
6. Bus Bar * CT Bus wire shorting operated one for Each Mesh
zone
7. Bus Bar * protection under test.
8. Bus Bar * protection SAS Communication fail (both channels)
(Segregate all related sources as applicable)

Bus Bar * Prot. BUSBAR * PROT


21 Trip
Operated 1. Bus Bar * Protection one for each zone Trip. (Segregate all OPERATE/NORMAL
related sources by phase from each zone as applicable)

1. Bus Bar * VT Main MCB Trip/Off Not Applicable as per SOW


2. Bus Bar * VT branch MCB Trip/Off
3. Bus Bar * VT fuse failed Alarm BUS * VT
22 Bus * VT Failed Non Trip
4. Bus Bar * VT Isolator Open FAILED/NORMAL
5. Bus Bar * VT Isolator Incomplete
6. Bus Bar * VT racked out (if applicable ) (Segregate all related
sources as applicable)
13.8 kV Single Bus bar

BUS * STUCK CB PROT


FAULTY/NORMAL
13.8 kV Bus bar Stuck
or
23 Breaker / BB * Non Trip Not Applicable as per OPDS
BUS * BB PROT
Protection Faulty
FAULTY/NORMAL
4. Bus Bar * Stuck breaker/BB Protection relay under test (As applicable)

**** = Breaker Number


#Table
= Equipment Number General Alarms
02-17: Substation
380/ 230;132;115;110kV, 230 / 69 kV AND 132;115;110 / 33kV ; 13.8 kV SUBSTATIONS

DIESEL GEN. Not applicable.


1 Emergency Diesel Fault Non Trip
1. Diesel generator fault FAULTY/NORMAL

125 V
4 Battery/Battery Charger- Not applicable as per scheme.
1 Faulty 125V BATTERIES /
5. 125V Battery Monitoring Panel MCB Trip
CHARGERS Non Trip
11. 125V Battery Charger-1 Over Voltage Alarm
FAULTY/NORMAL
13. 125V Battery charger-1 Diod dropper system Failure
125V BATTERIES /
CHARGERS Non Trip
FAULTY/NORMAL

5. 125V Battery Monitoring Panel MCB Trip


125 V
11. 125V Battery Charger-2 Over Voltage Alarm
5 Battery/Battery Charger- Not applicable as per scheme.
13. 125V Battery charger-2 Diod dropper system Failure
2 Faulty
(Add all related sources as applicable)
Table 02-17: Substation General Alarms (Contd.)
Not applicable as per scheme

48 V Battery / Battery 48 V DC GROUND


6 1. 48 V battery Earth Fault Relay Trip Non Trip
Charger Earth Fault ALARM/NORMAL
2. 48 V Battery Charger Earth Fault Relay Alarm (Add all related
sources as applicable)
Not applicable as per scheme
48 V Battery / Battery 48V BATTERY
7 3. Battery High Impedance Alarm Non Trip
Charger Earth Faulty FAULTY/NORMAL
7. Battery Charger Over Voltage Alarm (Add all related sources as
applicable)
1. OLS # Battery Voltage Low Alarm Not applicable as per PTS.
2. OLS # Battery Voltage High Alarm OLS CHARGER
8 OLS Charger Faulty Non Trip
3. OLS# Battery High Impedance Alarm (Add all related sources as FAULTY/NORMAL
applicable)
Not applicable as per PTS.

PLC CHARGER
9 PLC Charger Faulty Non Trip
FAULTY/NORMAL
1. PLC 48V Battery Faulty
2. PLC Battery Charger Faulty
3. PLC Battery Charger AC Supply Faile (Add all related sources as
applicable)
Not applicable
ENTRANCE
10 ------------------ Non Trip
ALARM/NORMAL
1. Entrance alarm-1
Not applicable
INTRUDER
11 ------------------ Non Trip
1. Entrance alarm-2 ALARM/NORMAL

380kV
15 Isolator Switching 2. 380kV Isolator #### Intermediate Alarm
Incomplete
380kV SWITCHING 380kV ES/DS switching inomplete cobmined alarms
INCOMP Non Trip provided. Intermediate alarm not applicable as per LCC
380kV ALARM/NORMAL scheme.
16 Earth Switch Switching
Incomplete
2. 380kV Earth Switch #### Intermediate
132kV
17 Isolator Switching
132kV SWITCHING 380kV ES/DS switching inomplete cobmined alarms
Incomplete
INCOMP Non Trip provided. Intermediate alarm not applicable as per LCC
ALARM/NORMAL scheme.
2. 132kV Isolator #### Intermediate Alarm

132kV
18 Earth Switch Switching 2. 132kV Earth Switch #### Intermediate Alarm
Incomplete

1. 380kV System synchronizer Faulty


380kV System
2. 380kV System synchronizer DC supply Fail 380kV SYS.SYNCH
28 Synchronizer Unit Non Trip System synch panel not applicable as per OPDS.
3. 380kVSystem synchronizer DC MCB Trip/OFF FAULTY/NORMAL
Faulty
4. 380kV KV System synchronizer SAS Communication fail (both
channels)
(Add all related sources as applicable)

380kV System
380kV SYS.SYNCH.
29 Synchronizer In Non Trip System synch panel not applicable as per OPDS.
1. 380kV System Sync in Progress (Add all related sources as INPROGRESS/NORMAL
progress
applicable)

380kV System 380kV SYS.SYNCH


30 1. 380kV System Synch Fail Non Trip System synch panel not applicable as per OPDS.
Synchronizer Unit fail FAILED/SUCCESSFULL
2. 380kV System Synch Block
(Add all related sources as applicable)

1. 132kV System Synchronizer Faulty


132kV System 2. 132kV System Synchronizer DC supply Fail 132 kV SYS.
31 Synchronizer Unit 3. 132kV System Synchronizer DC MCB Trip SYNCHRONIZER Non Trip System synch panel not applicable as per OPDS.
Faulty 4. 132kV System Synchronizer SAS Communication fail (both FAULTY/NORMAL
channels)
(Add all related sources as applicable)

132kV System 132kV SYS.


32 Synchronizer in SYNCHRONIZER Non Trip System synch panel not applicable as per OPDS.
1. 380kV System Sync in Progress (Add all related sources as
Progress INPROGRESS/NORMAL
applicable)

132kV SYS.
132kV System 1. 132kV System synch Fail
33 SYNCHRONIZER Non Trip System synch panel not applicable as per OPDS.
Synchronizer Unit fail 2. 132kV System synch Block
FAILED/SUCCESSFULL
(Add all related sources as applicable)
1,2,3: Not applicable, part of SAS.

13. System synch panel not applicable as per OPDS.


14. System synch panel not applicable as per OPDS.
1. Common Annunciator panle # AC Supply Fail. AC/DC COMMON 15. Not applicable as per scheme
34 Alarm System Faulty 2. Common Annunciator panel # DC Supply Fail. SUPPLY Non Trip 25. Not applicable as per scheme
3. Common Annunciator # Faulty. FAILED/NORMAL 26. Not applicable as per PTS
13. 380kV System synchronizer Panel # AC Supply Fail
14. 132kV System synchronizer Panel # AC Supply Fail
1,2,3: Not applicable, part of SAS.

13. System synch panel not applicable as per OPDS.


14. System synch panel not applicable as per OPDS.
1. Common Annunciator panle # AC Supply Fail. AC/DC COMMON 15. Not applicable as per scheme
34 Alarm System Faulty 2. Common Annunciator panel # DC Supply Fail. SUPPLY Non Trip 25. Not applicable as per scheme
3. Common Annunciator # Faulty. FAILED/NORMAL 26. Not applicable as per PTS
13. 380kV System synchronizer Panel # AC Supply Fail
14. 132kV System synchronizer Panel # AC Supply Fail
15. Common BCU/IO Box Panel # AC supply Fail
25. PDMS Panel # AC/DC Supply Fail
26. Cable Tempt. Panel # AC/DC supply Fail

380kV On Line Partail 1. 380kV Partial Discharge Ethernet switch # faulty


2. 380kV Partial Discharge Sensor # faulty. 380kV P.DISCHARGE As per vendor (QUALITROL), one alram "Partial Discharge
37 Discharge Watch Non Trip
3. 380kV Partial Discharge System Dard disc capacity over flow. FAULTY / NORMAL system fail" available. The same already considered in SPL.
System
4. 380kV Partial Discharge monitoring system faulty
5. 380kV Partial Discharge System DC Supply fail.
6. 380kV Partial Discharge system faulty.
7. 380kV Partial Discharge system Communication fail (both
channels)
(Add all related sources as applicable)
1. 132kV Partial Discharge Ethernet switch # faulty.
132kV On Line Partail 2. 132kV Partial Discharge Sensor # faulty.
132kV P.DISCHARGE
38 Discharge Watch 7. 132kV Partial Discharge system Communication fail (both Non Trip Not applicable as per vendor scheme.
FAULTY / NORMAL
System channels)
(Add all related sources as applicable)
AUTOMATIC SWITCHING
Panel not available as per SOW
1. ASE Instruction control time out
ASE Automatic AUTO SWITCHING.
39 2. ASE Block Non Trip
Switching Failed FAILED/NORMAL
3. ASE fail
Add all related sources as applicable)
Panel not available as per SOW

1. ASE relay Faulty


ASE Automatic 2. ASE Processor watchdogs AUTO SWITCHING
40 Switching Equipment 3. ASE DC Supply Fail EQUIP Non Trip
Faulty 4. ASE Input discrepancy FAULTY/NORMAL
5. ASE Automatic switching Equipment out of service
6. ASE Automatic switching Equipment Relay # SAS
Communication Fail (both channels)
(Add all related sources as applicable)
Panel not available as per SOW
ASE Auto SW. EQ. AUTO SW.EQ. REMOTE
41 1. Auto Sw. Eq. Selected to Local (Add all related sources as Non Trip
Remote Off OFF/ON
applicable)
AUTO CHANGEOVER SWTCHING EQUIPMENT (ACSE) ALARMS
ACSE panel not available.
42 ACSE Remote OFF 1. ACSE Selected to Local ACSE REMOTE OFF/ON Non Trip
2. ACSE Station Authority SAS/ECC
ACSE panel not available.
1. ACSE Instruction control time out.
ACSE -Auto 2. ACSE Fail AUTOCHANGEOVER
43 3. ACSE Block Non Trip
Changeover Failed FAILED/NORMAL
4. ACSE discrepancy alarm.
(Add all related sources as applicable)
1. ACSE not ready. ACSE panel not available.
ACSE/TOP Auto ACSE/TOP
44 2. TOP not ready. Non Trip
Changeover Faulty NOT READY/READY
(Add all related sources as applicable)
ACSE panel not available.
1. ACSE not ready. ACSE/TOP
45 ACSE/TOP Not Ready 2. TOP not ready. Non Trip
NOT READY/READY
(Add all related sources as applicable)
Under Frequency /Under Voltage Alarms

Section # Under
UNDERFREQ RLY
46 Frequency Protection 3. SEC # Under Frequency Relay # MCB Trip/Off Non Trip Combined with DC supply fail as per OPDS
FAULTY/NORMAL
Faulty

Under Voltage # UNDER VOLT RLY


48 Non Trip Combined with DC supply fail as per OPDS
Protection Faulty FAULTY/NORMAL
3. Under Voltage Relay # MCB Trip/Off

FCCS ALARMS

4. PT Fuse supervision OPTD or Failure / PT MCB trip.


5. FCCS sequence Failed Not applicable as per OPDS.
50 FCCS Failed FCCS FAILED/NORMAL Non Trip
6. FCCS Sync. Fail.

ABTS ALARMS

52 ABTS Failed ABTS FAILED/NORMAL Non Trip Not applicable as per OPDS.

5. ABTS VT Fuse Fail


1. ABTS selected to LOCAL ABTS REMOTE OFF/ ON
53 ABTS Remote Non Trip Not applicable as per OPDS.
2. ABTS station authority SAS/CRCC (Add all related sources as (as applicable)
applicable)
FAULT RECORDER ALARMS

2. 380kV F.R Memory full


3. 380kV F.R Out of paper
4. 380kV F.R Paper low
380kV Fault Recorder
57 5. 380kV F.R Processor watchdogs
Faulty
6. 380kV F.R Printer faulty
7. 380kV F.R Supply supervision OPTD
8. 380kV F.R Out of service
FAULT RECORDER
Non Trip Not applicable as per FR scheme.
FAULTY/NORMAL
2. 132kV F.R Memory full
3. 132kV F.R Out of paper
4. 132kV F.R Paper low
132kV Fault Recorder
58 5. 132kV F.R Processor watchdogs
Faulty
6. 132kV F.R Printer faulty
7. 132kV F.R Supply supervision
8. 132kV F.R Out of service

Table 02-18: FSC - Fixed Series Compensation


NOT APPLICABLE AS PER PTS
1. Move - Accum Energy Trip
2. Capacitor Overload Trip
3. Capacitor High Unbalance Trip
FSC # Capacitor Bank 4. Fault to Platform Prot. Trip FSC # CAP. BANK PROT.
1 Trip
Prot. 5. Spark Gap - sustained current Trip OPERATE /NORMAL
6. FSC # Bank lock out Relay Trip
7. Move - faulty unit detected
( Add all related sources by phases and stages for each function as
applicable)
NOT APPLICABLE AS PER PTS
FSC # BY FSC #
1. BPD # Pole Disagreement
2 Passed/BANK DS/ES BYPASSEDSWITCHING Non Trip
(Add all related sources by phases and stages for each function as
Switching INCOMPLETE/NORMAL
applicable)
NOT APPLICABLE AS PER PTS

1. Interface CBL- 125 VDC MCB Fail


2. Interface CBL- 24 VDC Power Supply Fail
FSC # CB # 3. Prot. CBL - 125 VDC MCB Fail FSC # AC/DC SUPPLY
3 4. Prot. CBL - 24 VDC Power Supply Fail Non Trip
AC/DC Supply FAILED /NORMAL
5. Prot. CBL - 48 VDC Power Supply Fail
6. Signal Transmitter Power Supply Fail
7. BPCB # Loss of Heating and AC Supply Fail ( Add all related
sources by phases for each function as applicable)
NOT APPLICABLE AS PER PTS
1. Sub Harmonic Resonance alarm
4 FSC # FERRORES 2. Sub Harmonic Resonance
3. Sub Harmonic Resonance Prot. FSC # FERRORESO
Non Trip
( Add all related sources by phases for each function as applicable ALARM /NORMAL
NOT APPLICABLE AS PER PTS
FSC # CB #
5 1. Signal Transmitting Channel Fail
Intertrip
( Add all related sources by phases for each function as applicable)
NOT APPLICABLE AS PER PTS

FSC # LP Main SS & 1. Delayed By Pass Command From Main Station FSC # INTERTRIP
6 Trip
LP Remote SS 2. Delayed By Pass Command From Remote End RECEIVED /NORMAL
3. Fast By Pass Command From Main Station
4. Fast By Pass Command From Remote End ( Add all related
sources by phases for each function as applicable)
FSC NOT APPLICABLE AS PER PTS
FSC # CB #
7 1. Direct Transfer Trip Command to Line C.B ( Add all related # INTERTRIP SEND/NOR Trip
Intertrip
sources by phases for each function as applicable) MAL
NOT APPLICABLE AS PER PTS

1. Capacitor Unbalance Protection OPTD


FSC # Capacitor Bank FSC # CAP. BANK PROT.
8 2. Protection System - Parallel System Fail Non Trip
Prot. FAULTY /NORMAL
3. Protection System Parallel System SAS Communication fail
(both channels)
( Add all related sources by phases for each function as applicable)
Table 02-18: FSC - FIXED SERIES COMPENSATION (Contd.)
NOT APPLICABLE AS PER PTS

1. Spark Gap - PH R - Self Ignition Trip


2. Protection System - Laser Power Fault
3. Excessive Internal Fault Current
4. By Pass CB - Max Line Current
5. Spark Gap Protection FSC # SYSTEM
9 FSC # System Non Trip
6. Mov.–Exs. Energy. Absorption Rate ABNORMAL / Normal
7. Mov.-Accum Energy
8. Protection– Temperature Measurement Failed
9. Capacitor - Overload Trip Counter
10. Protection System - Field Bus Fail
11. Capacitor Overload Alarm
12. SP Forced Trigger Failure
13. Forced Trigger Link Fail
( Add all related sources by phases for each function as applicable)
1. BPCB # failed to Close FSC # CBF OPERATE Trip NOT APPLICABLE AS PER PTS
10 FSC # CBF
(Segregate all related sources and function as applicable) /NORMAL
**** CLOSE FAILURE Non Trip NOT APPLICABLE AS PER PTS
(C.B #) Close Failure 1. Close Failure protection supervision. PROT. OPERATE
11
Protection Operated ( For Series Compensation Breakers as required) ( Add all related /NORMAL
sources as applicable)
1. Line Current Supervision **** LINE CURRENT Non Trip NOT APPLICABLE AS PER PTS
(C.B #) Line Current SUPERVISION
12 (For Series Compensation Breakers) (Add all related sources as
Supervision Operated OPERATE/ NORMAL
applicable)
**** = Breaker Number#### = Isolator Number# = Equipment Number
Table 02-19: 132/110/33/13.8 kV (as applicable) Shunt Capacitor Bank Alarms

33/13.8 kV
1 Capacitor Bank # SET-1
Protection Operated 10. SET-1 94-1 Trip relay Optd
CAP. BANK # PROT
Trip Not applicable as per OPDS
OPERATED/NORMAL
33 / 13.8 KV
2 Capacitor Bank # SET-2
10. SET-2 94-2 Tript relay Optd
Protection Operated

Table 02-19: 132/110/33/13.8 kV (as applicable) Shunt Capacitor Bank Alarms (Contd.)

33/13.8 kV
Capacitor 3. SET-1 Protection Relay MCB Trip/OFF
5
Bank # Protection SET- 4. SET-1 Protection VT Fuse Failure
1 Faulty CAP. BANK # PROT
Non Trip Not applicable as per OPDS
FAULTY/NORMAL
33/13.8 kV
6 Capacitor Bank # 3. SET-2 Protection Relay MCB Trip/OFF
Protection SET-2 Faulty 4. SET-2 Protection VT Fuse Failure

33/13.8 kV
7 Capacitor Bank ACCS 3. ACCS DC SupplyFailure.
AC/DC Supply Fail 4. ACCS AC Supply Failure

CAPA. BANKS AC/DC


Non Trip Not applicable as per OPDS
SUPPLY FAIL/NORMAL
CAPA. BANKS AC/DC
Non Trip Not applicable as per OPDS
SUPPLY FAIL/NORMAL
33/13.8 kV
Capacitor
8
Bank # Protection
AC/DC Supply Fail

1. Protection Panel # AC Supply Failure


4. Protection Panel # DC MCB Trip

33/13.8 kV ACCS
9 3. ACCS Relay # Control DC Supply Fail Non Trip Not applicable as per OPDS
ACCS Faulty FAULTY /NORMAL

# = Capacitor Bank Number


Table 02-20: Grounding Transformer Alarms
JUSTIFICATION
No. Source Alarm Received At ECC Status
HMI Alarm

Ground Transformer 1. Ground Transformer # Phase Over current (O/C)


1
# O/C Prot. Optd Protection Trip
(Add and segregate all related sources by phase for each function as
applicable)

Ground Transformer #
2
REF Prot. Optd 1. Ground Transformer # REF 64-1 Protection Trip
(Add and segregate all related sources for each function as
applicable) GRNDTRAFO # PROT
Trip
OPERATED/NORMAL

Ground Transformer #
3
Neutral O/C Prot. OPTD
1. Ground Transformer #Neutral O/C Protection Operated
(Add and segregate all related sources as applicable)
Ground Transformer # 1. Ground Transformer # Lock Out Relays OPTD (Add and
4
Lock Out Relay segregate all related sources as applicable)

st
Ground Transformer 1. Ground Transformer # Buchholz (2 Stage)
5
# Buchholz STG -2 2. Ground Transformer # Winding Temperature (2st Stage)
(Add all related sources as applicable
NOT APPLICABLE AS PER PTS
NOT APPLICABLE AS PER PTS

GRND TRAFO #
Ground Transformer
6 BUCHHOLZ STG-1 Non Trip
# Buchholz Stage-1
ALARM /NORMAL
1. Ground Transformer # Buchholz Gas (1st Stage) (Add all related
sources as applicable)

GRND TRAFO #
Ground Transformer #
7 WINDING TEMP. STG-1 Non Trip
Winding Temp. Stage -1
st ALARM /NORMAL
1. Ground Transformer # winding temperature (1 Stage)
(Add all related sources as applicable)

Ground Transformer #
8
Pressure Relief Deviece
1. Ground Transformer # Pressure Relief Device Trip
(Add all related sources as applicable)
GRND TRAFO #
Non Trip
ALARM/NORMAL
Ground Transformer #
9 Oil Level 1. Ground Transformer # Oil Level Low
/Temperature alarm 2. Ground Transformer # Oil Level High
3. Ground Transformer # Oil Temperature High (1st Stage)
(Add all related sources as applicable)

1. Ground Transformer # Over Current (O/C) Protection Relay


Faulty
2. Ground Transformer # Over Current (O/C) Relay DC Supply
Ground Transformer # Fail GRND TRAFO # PROT
10 Non Trip NOT APPLICABLE AS PER PTS
Prot. Faulty 3. Ground Transformer # REF (64-1) Protection Faulty FAULTY/NORMAL
4. Ground Transformer # REF (64-1) Relay DC Supply Fail
5. Ground Transformer # Over Current (O/C) Relay SAS
Communication faulty
6. Ground Transformer # # REF (64-1) Relay SAS
Communication faulty
(Add all related sources as applicable)
# = Grounding Transformer Number
Table 02-21: Static VAR Compensator (SVC)

SVC BB VT
SVC BB VT FAILED/NORMAL
3 Non- Trip Not applicable as per SOW.
Fail Should be segregated for
1. SVC BB VT Fuse Failure Alarm each BB as applicable
1. TCR # cooling system trip from PLC -1
2. TCR # cooling system trip from PLC -2
3. TCR # cooling system temperature high trip.
4. TCR # cooling system main flow low trip.
5. TCR # cooling system pressure high trip.
6. TCR # cooling system conductivity high trip.
TCR # 7. TCR # cooling system main flow high trip. TCR # COOLING
6 Cooling System Control 8. TCR # cooling system low level trip. SYSTEM Trip Not applicable as per SOW.
Panel. 9. TCR # cooling system Thyristor flow trip. FAULTY/NORMAL
10. TCR # cooling system SAS Communication Fail (both channels)
(Add all related sources signals for each function as applicable)

2. TCR # thermal over Load protection (49 #) trip.


3. TCR # back up protection over current (50/51) trip.
4. TCR # back up protection earth fault (50N) trip.
TCR # 5. TCR # negative phase sequence protection (46Q) trip. TCR # PROTECTION
7 Trip Not applicable as per SOW.
Protection Panel 6. TCR # neutral current unbalance protection trip. OPERATE/NORMAL
7. TCR # Backup O/V protection trip
9. TCR # trip relay (94 #) Optd.

2. TCR # Backup protections relay Faulty


3. TCR # Main protection DC system1 MCB trip
4. TCR # Main protection DC system2 MCB trip
6. TCR # Backup protection DC supply Fail
7. TCR # Backup protection DC system1 MCB trip
TCR # TCR # PROTECTION
8 8. TCR # Backup protection DC system 2 MCB trip Non Trip Not applicable as per SOW.
Protection Panel FAULTY/NORMAL
9. TCR # Main protection Under Test.
10. TCR # Backup protection Under Test.
11. TCR # main protections relay clock synchronization error.
12. TCR # Backup protections relay clock synchronization error.
13. TCR # Backup Protections SAS Communication Fail (both
channels)
1. SVC Control -1 TCR # Closed loop control (CLC) general trip.
2. SVC Control - 2 TCR # Closed loop control (CLC) general trip.
SVC Controller 3. System - 1 TCR # VBE minimum Thyristor level reached trip. SVC CONTROLLER
9 4. System -2 TCR # VBE minimum Thyristor level reached trip. Trip Not applicable as per SOW.
Operated OPERATE/NORMAL
5. System -1 TCR # Trip Due to enduring DC current.
6. System -2 TCR # Trip due to enduring DC current.
7. System -1 TCR # Trip due to junction temperature high
8. System -2 TCR # Trip due to junction temperature high
9. System -1 TCR # Trip due to VBE rack fault detection hard
fault.
10. System -2 TCR # Trip due to VBE rack fault detection hard
fault.
(Add and segregate all related sources from trip signals for each
function as applicable)

1. TSC # cooling system trip from PLC -1


2. TSC # cooling system trip from PLC -2
3. TSC # cooling system temperature high trip.
4. TSC # cooling system main flow low trip.
TSC # COOLING
TSC # Cooling System 5. TSC # cooling system pressure high trip.
10 SYSTEM Trip Not applicable as per SOW.
Control Panel. 6. TSC # cooling system conductivity high trip.
FAULTY/NORMAL
7. TSC # cooling system main flow high trip.
8. TSC # cooling system low level trip.
9. TSC # cooling system thyristor flow trip.
10. TCR # cooling system SAS Communication Fail (both channels)
(Add all related sources from trip signals for each function as
applicable)

1. TSC # differential protection (87 # ) trip


2. TSC # thermal over Load protection (49 #) trip.
3. TSC # back up protection over current (50/51) trip.
4. TSC # back up protection earth fault (50N) trip
TSC # PROTECTION
11 TSC # Protection Panel 5. TSC # negative phase sequence protection (46Q) trip. Trip Not applicable as per SOW.
OPERATE/NORMAL
6. TSC # Backup O/V protection trip
7. TSC # # neutral current unbalance (60C) protection trip
8. TSC # # lockout relays (86 #) Optd.
9. TSC # # trip relay (94 #) Optd.
(Add all related sources from trip signals for TSC by phase and
stages for each function as applicable)
1. Filter # diff. protection (87) trip.
2. Filter # backup overcurrent protection (50/51) trip.
3. Filter # thermal overload protection (49) trip.
FILTER # PROTECTION
12 Filter # Protection Panel 4. Filter # backup negative sequence protection (46Q) trip. Trip Not applicable as per SOW.
OPERATE/NRMAL
5. Filter # backup protection relay capacitor unbalance (60C) trip.
6. Filter # Backup O/V protection trip
7. Filter # lockout relays (86 #) Optd.
8. Filter # trip relay (94 #) Optd.
(Add all related sources from trip signals for filter by phase and
stages for each function as applicable)

1. TCR# UPS battery low voltage.


2. TCR# UPS Faulty.
3. TCR # cooling system alarm from PLC
4. TCR # cooling system DC supplies # failure.
5. TCR # cooling system AC supplies # failure.
TCR # Cooling System 6. TCR # cooling system primary pump thermal protection faulty. TCR# COOLING SYSTEM
13 7. TCR # cooling system primary pump AC MCB trip. Non Trip Not applicable as per SOW.
Control Panel. ALARM/NORMAL
8. TCR # cooling system fan thermal protection fault.
9. TCR # cooling system fan MCB trip.
10. TCR # cooling system flow low alarm.
11. TCR # cooling system conductivity high alarm.
12. TCR # cooling system main circuit pressure high alarm.
13. TCR # cooling system main circuit pressure low alarm.
14. TCR # cooling system main flow high alarm.
15. TCR # cooling system thyristor flow alarm.
16. TCR # cooling system outdoor temperature low alarm.
(Add all related sources from each alarm function for TCR cooling
system alarm as applicable)
1. TSC # main protections relay unbalance alarm.
2. TSC # Thyristor thermal protection.
3. TSC # voltage divider System faulty phase RY.
4. TSC # voltage divider System faulty phase YB.
5. TSC # voltage divider System faulty phase BR.
TSC # 6. TSC # backup protection capacitor unbalance (60 TSC # PROTECTION
14 Non trip Not applicable as per SOW.
protection panel C) alarm ALARM/NORMAL
(Add all related sources from each alarm function of TSC #
protection by stages and phase for function as applicable)
1. TSC # UPS battery low voltage.
2. TSC # UPS Faulty
3. TSC # cooling system alarm from PLC
4. TSC #cooling systems DC supply # failure alarm.
5. TSC #cooling systems AC supply # failure.
6. TSC # cooling system primary pump thermal protection faulty.
7. TSC # cooling system primary pump AC MCB trip.
8. TSC # cooling system fan thermal protection fault.
9. TSC # cooling system fan MCB trip.
10. TSC # cooling system flow low alarm.
11. TSC # cooling system conductivity high alarm.
12. TSC # cooling system main circuit pressure high alarm.
13. TSC # cooling system main circuit pressure low alarm.
14. TSC # cooling system main flow high alarm.
TSC # COOLING
TSC # Cooling System 15. TSC # cooling system Thyristor flow alarm.
15 16. TSC # cooling system outdoor temperature low alarm. SYSTEM Non trip Not applicable as per SOW.
Control Panel.
(Add all related sources from each alarm function for TSC cooling ALARM/NORMAL
system as applicable

1. TSC # Main protections relay Fauly.


2. TSC # Backup protections relay Fauly.
3. TSC # Main Protection DC system 1 MCB trip.
4. TSC # Main Protection DC system 2 MCB trip.
5. TSC # Backup Protection DC system 1 MCB trip.
6. TSC # Backup Protection DC system 2 MCB trip.
7. TSC #Main protection DC Supplyfail.
8. TSC #Backup protections DC Supply fail.
9. TSC # Main protection DC under Test.
TSC # PROT.
16 TSC # protection panel 10. TSC # Backup protection DC under Test. Non trip Not applicable as per SOW.
11. TSC # main protections relay clock synchronization error. FAULTY/NORMAL
12. TSC # Backup protections relay clock synchronization error.
13. TSC # Main protection SAS Communication Fail
14. TSC # Backup protection SAS Communication Fail
(Add all related sources for function as applicable)
1. Filter # main protection faulty.
2. Filter # main protection DC system 1 MCB trip
3. Filter # main protection DC system 2 MCB trip
4. Filter # main protection DC supply Fail.
5. Filter # main protection under test
6. Filter # main protection relay clock synchronization error.
7. Filter # main protection SAS Communication Fail
8. Filter # backup protection faulty.
9. Filter # back up protection DC system 1 MCB trip Filter # PROT.
17 Filter # Protection Panel 10. Filter # back up protection DC system 2 MCB trip Non Trip Not applicable as per SOW.
FAULTY/NORMAL
11. Filter # back up protection DC supply Fail
12. Filter # back up protection under test
13. Filter # back up protection relay clock synchronization error.
14. Filter # Back up protection SAS Communication Fail
(Add all related sources for function as applicable)

SVC AC/DC 1. Protection panel # AC MCB trip. AC/DC SUPP. Non Trip
supply 2. Protection panel # DC Supply Fail. FAILED/NORMAL
3. control panel# DC MCB trip Should be segregated for
4. Binary interface panles # 24V DC supply failure each bay
5. Protection interface panles # 24V DC supply failure (TSC, TCR, Filtr, HV
6. Binary interface panels # DC power supply failure Linl, Aux.TRF. Earting
7. TCR # Dis-Connector motor MCB trip TRF,…etc)
18 8. TSC # Dis-Connector motor MCB trip Not applicable as per SOW.
9. TCR # Dis-Connector power supply MCB trip.
10. TSC # Dis-Connector power supply MCB trip.
11. Earthing switch # motor MCB trip.
12. Voltage Stabilizer alarms
(Add all related sources for each function as applicable)

**** Control Mode 1. **** Control Mode Selected to OFF. **** REMOTE OFF / ON Non Trip Not applicable as per SOW.
Remote OFF 2. **** Control Mode Selected to LOCAL. Should be segregated for
3. **** Control Mode Selected to BCU. each C.B/Isolator /Load
4. **** Control Mode Selected to SAS. break switch as applicable
19
5. **** Control Mode Authority Set toSAS/ECC (Add all related
sources as applicable)

Note: Auxilary Transformer, Ground Transformer and any other equipment shoud be as related tables
Table 02-22: Command and Back Indications (As Applicable)
*** (FPFM) LINE IN/OUT kept upto HMI as per CSD OCD requirement
4 I
Protection (applicable as per area)
*** (FPSM) LINE IN/OUT kept upto HMI as per CSD OCD requirement
5 I
Protection (applicable as per area)
*** (SET1) SGT/GT IN/OUT kept upto HMI as per CSD OCD requirement
6 I
Protection (applicable as per area)
*** (SET2) SGT/GT IN/OUT kept upto HMI as per CSD OCD requirement
7 I
Protection (applicable as per area)
*** AUTO REC IN/OUT Not applicable for 115kV UG, 380kV already provided
8 C-I
(FPFM) (applicable as per area)
*** AUTO REC IN/OUT Not applicable for 115kV UG, 380kV already provided
9 C-I
(FPSM) (applicable as per area)
IN/OUT Not applicable.
10 *** REV. Power I
(applicable as per area)
11 *** Remote LOCAL/REMOTE (as applicable per area) I REMOTE OFF alarm provided.
380 kV System Not applicable as per PTS
12 I
Synchronizer LOCAL/REMOTE (as applicable per area)
Not applicable as per PTS
230/132/115/110/69/33
13 I
kV System Synchronizer
LOCAL/REMOTE
380kV System Not applicable as per PTS
14 C-I
Syncronizer IN/OUT
Not applicable as per PTS
230/132/115/110/69/33
15 C-I
kV System Synchronizer
IN/OUT
16 System Synchronizer Emergency Stop (as applicable per area) I Not applicable as per PTS
17 System Synchronizer In Progress (as applicable per area) I Not applicable as per PTS
**** Closing Via ON Not applicable as per PTS
18 C
System Synchronizer Command and indication should be configured as single.
IN/OUT Not applicable as per PTS
19 *** P.W. PROT I
(applicable as per area)
ON Indiaction provided, comman not applicable as per OPDS
21 *** TOP Command should be configured as double and indication should be C-I
configured as single.
ABTS IN/OUT provided, comman not applicable as per
23 ***ABTS C-I OPDS.
ON/OFF
Table 02-22: Command and Back Indications (As Applicable) (Contd.)

No. Alarm Received At ECC Type


Text
Indication kept aupto HMI as per CSD, OCD meeting.
### BB Prot. (segregate
23 I
by SET-1/2 )
IN/OUT (as applicable per area and (segregate by SET-1/2 )

### BB Prot. (segregate


24 I
by SET-1/2 )
IN/OUT (as applicable per area and (segregate by SET-1/2 )
25 ### Auto SWEQ IN/OUT (as applicable per area) C-I AUTO REC IN/OUT Provided for 380kV
26 BB CHK Prot. IN/OUT (as applicable per area) I Provided
27 ACSE IN/OUT C-I Not applicable as per PTS.
IN/OUT indication provided, command not applicable as per OPDS.
28 ABTS C- I
IN/OUT
29 ABTS REST C- I Not applicable as per PTS.
RESRT/ALARM (as applicable per area)
Indiaction provided, however command not applicable as per OPDS.
30 TOP C-I Note: Kept upto HMI as per CSD OCD comments.
IN/OUT
31 +++ AVC AUTO/MANUAL C-I Provided
FOLLOWER/INDEPENDENT Provided
32 +++ AVC C-I
(applicable per area)
OFF/ON Remote OFF/ON alarm provided.
33 +++ AVC REMOTE I
should be configured as single point
ON/OFF Provided
34 +++ INDEPENDENT Inaication should be configure as single point Command should be C-I
configure as double
ON/OFF Provided
35 +++ MASTER Indication should be configure as single point Command should be C-I
configure as double
ON/OFF Provided
36 +++ FOLLOWER Indication should be configure as single point Command should be C-I
configure as double
37 +++ TAP RAISE/LOWER C-I Provided
+++ UNDER FREQ IN/OUT indication provided, command not applicable as per OPDS.
38 RLY (as applicable by C-I
stage or relay) IN/OUT (as applicable per area)
IN/OUT indication provided, command not applicable as per OPDS.
+++ UNDER Voltage
39 RLY (as applicable by C-I
stage or relay)
IN/OUT (as applicable per area)
40 ACCS AUTO /MANUAL C-I AUTO/MANUAL provided, command not applicable.
41 ACCS IN/OUT (as applicable per area) C-I
OFF/ON Provided
42 ACCS Remote I
should be configured as single point
43 xxx SVC START/STOP (as applicable per area) C-I Not applicable as per PTS.
xxx SVC Reference Not applicable as per PTS.
44 C-I
Voltage RAISE/LOWER (as applicable per area)
Xxx SVC Emergency Not applicable as per PTS.
45 I
Stop EMERGENCY STOP (as applicable per area)
Table 02-22: Command and Back Indications (As Applicable) (Contd.)

No. Alarm Received At ECC Type


Text
46 xxx SVC Cooling START/STOP I Not Applicable Not applicable as per PTS.
47 yyy TCR START/STOP I Not Applicable Not applicable as per PTS.
Not applicable as per PTS.
48 yyy TCR Mode Select I Not Applicable
MVAR/KV
49 13.8kV C.B Rack IN/OUT I Not Available Provided.
50 FCCS FCCS Ready I Not Applicable Provided.
51 FCCS In Progress I Not Applicable Provided.
52 FCCS IN/OUT C-I Not Applicable Provided.
53 FCCS LOCAL / REMOTE I Not Applicable Provided.
*** (FPFM) Cap. Bank Provided.
54 IN/OUT (as applicable as per area) I Available
Protection
*** (FPSM) Cap. Bank Provided.
55 I Available
Protection IN/OUT (as applicable as per area)
56 Dummy ON/OFF ON/OFF (as applicable as per area) C-I Not Applicable Not applicable.
*** = C.B No
+++
Table=02-23:
Transformer
AnalogNo. xxx = SVC
Measure and No.
Value Acquisition at Local Control Panel and ECC
No Data Source MW MVAR Frequency TAP Volts
1 11 - 34.5 kV Feeder √ √ - - -
- -

69 - 380 kV
2 √ -
Feeder


√ -
√ (HV&LV
3 Power Transformer √ (HV& LV - (Position
Side) )
Side)
Static VAR √ √ (Ref
4 √ -
Compensator (SVC) - (Percent) Voltage)
5 Capacitor Bank - √ - - √
Thyristor Controlled √ √
6 √ -
Reactor(TCR) - (Percent) (High Side)
7 Shunt Reactor - √ - - -
- √
(Each Section)

8 Bus Bar - √

-
TCR & SVC not applicable in SS. Remaining all are provided.

Table 02-24: SAS Alarms (As per voltage levels)


NOTE- ALL SAS SIGNALS HAS TO BE FOLLOWED AS
PER ALSTOM SAS STANTERDISATION INPUT

1. SCADA Gateway 1 Faulty


2. Gateway DIP (Device Interface Processor) # faulty
1 GW1 Faulty 3. Media Converter # faulty (RS232-FO)
4. Modem # faulty
(USB license , Windows stop , Any Application stop running , HD
capacity full , HD remove,
any internal faulty, P.S faulty, disconnect from network)
(Add all related sources as applicable) ** SAS GATEWAY
Non Trip
FAULTY/NORMAL
** SAS GATEWAY
Non Trip
FAULTY/NORMAL

1. SCADA Gateway 2 Faulty


2 GW2 Faulty 2. Gateway DIP (Device Interface Processor) # faulty
3. Media Converter # faulty (RS232-FO)
4. Modem # faulty
USB license , Windows stop , Any Application stop running, HD
capacity full, HD remove, any internal faulty, P.S faulty, disconnect
from network (Add all related sources as applicable)

1. Main Server Faulty


3 Main Server Faulty 2. Main server DIP (Device Interface Processor) # faulty
USB license , Windows stop , Any Application stop running , HD
capacity full , HD remove , any internal faulty, P.S faulty,
disconnect from network (Add all related sources as applicable)

** SAS STATION PC
Non-Trip
FAULTY/NORMAL

1. Redundant Server Faulty


4 Redunt. Server Faulty
2. Redundant server DIP (Device Interface Processor) # faulty
USB license , Windows stop , Any Application stop running , HD
capacity full , HD remove , any internal faulty, P.S faulty,
disconnect from network
(Add all related sources as applicable)
NOTE- ALL SAS SIGNALS HAS TO BE FOLLOWED AS
PER ALSTOM SAS STANTERDISATION INPUT
1. Operator Work Station-1 Faulty
5 OWS1 Faulty 2. USB license , Windows stop , Any Application stop running ,
HD capacity full , HD remove , any internal faulty, P.S faulty, server
disconnect from network
(Add all related sources as applicable) ** SAS OPERATION PC
Non Trip
FAULTY/NORMAL

1. Operator Work Station – 2 Faulty


2. USB license , Windows stop , Any Application stop running ,
6 OWS2 Faulty
HD capacity full , HD remove, any internal faulty, P.S faulty, server
disconnect from network
3. Large screen Faulty
(Add all related sources as applicable)
1. Engineering Work Station Faulty
2. USB license , Windows stop , Any Application stop running , **SAS ENGINEERING PC
7 EWS Faulty HD capacity full , HD remove , any internal faulty, P.S faulty; Non- Trip
FAULTY/NORMAL
disconnect from network
(Add all related sources as applicable)
1. LAN Switch # Faulty.
2. LAN Switch # DC1&2 Suppply fail.
3. PRP RED BOX Switch Faulty ** SAS SWITCHES
8 SAS Switch Falty 4. Router Faulty (If Applicable) Non- Trip
FAULTY/NORMAL
5. Including Internal P.S faulty (P.S 1, 2).
6. Switch internal faulty (exchanging) (Add all related sources as
applicable)

1. GPS Server-1 Faulty.


2. GPS Server-1 DC Supply fail
9 GPS1 Faulty 3. Antenna 1 failer
4. GPS-1 Sync. Fail
5. IRIGB port failure, GPS stop running. (Add all related sources
as applicable) ** SAS GPS
Non- Trip
FAULTY/NORMAL
1. GPS Server 2 Faulty.
2. GPS Server-2 DC Supply fail
10 GPS2 Faulty 3. Antenna 2 fail
4. GPS-2 Sync. Fail
5. IRIGB port failure, GPS stop running. (Add all related sources
as applicable)
NOTE- ALL SAS SIGNALS HAS TO BE FOLLOWED AS
1. SAS Panel # MCB DC supply Fail PER ALSTIOM SAS STANTERDISATION INPUT
2. SAS Panel # DC Supply Fail
SAS PNL AC / 3. SAS Panel # MCB AC supply Fail ** SAS AC/DC SUP
11 Non-Trip
DC Fail 4. SAS Inverter -1 Faulty FAILED NORMAL
5. SAS Inverter 2 Faulty
(Add all related sources as applicable)

1. ** Common BCU/IO Box # Control supply fail


2. ** Common BCU/IO Box # MCB TRIP
3. ** Common BCU/IO Box # DC Supply Fail
4. ** Common BCU/IO Box faulty
** Common BCU # 5. Any fiber optic cable or Ethernet cable between switches and ** COMMON BCU
12 Non Trip
Faulty Common BCU- ( I/O box ) – (Channel A or Channel B) ( general FAULTY/NORMAL
alarm devise )
Note ; Common BCU/ IO Box alarms used as
separate alarm for each voltage level
(Add all related sources as applicable)
Non-Trip
SAS Fiber COMM 1. All sources related to fibers, including any fiber optic cable ** SAS FIBER COMM
13
Faulty between switches and station network (Upper level). FAULTY /NORMAL
(Add all related sources as applicable).

1. **Any fiber optic cable or Ethernet cable between switches and ** SAS BCU COMM
14 ** SAS BCU COMM Non Trip
BCU devices (Channel A or Channel B (Lower level). FAULTY /Normal
2. Alarms used as separate alarm for each voltage level
1. All sources related to fibers, including any fiber optic cable
** SAS PROTECTION/
** SAS PROTECTION between switches and protection devices (Channel A or Channel B
15 COMM Non Trip
/ COMM FAULTY (Lower level).
(Add all related sources as applicable) FAULTY /Normal
2. Alarms used as separate alarm for each voltage level
1. Any fiber optic cable or Ethernet cable between switches and Non Trip
** SAS BCPU COMM BCPU devices (lower level). ** SAS BCPU COMM
16
FAULTY (Channel A or Channel B) FAULTY /Normal
2. alarms used as separate alarm for each voltage level
**SAS CUBICLES
SAS Cubicles
17 TEMPERATURE Non Trip
Temperature
1. Add all sources related to SAS Cubicles Temperature HIGH/NORMAL
1. When Any Authorizes User Log in SAS System in Substaion NOTE- ALL SAS SIGNALS HAS TO BE FOLLOWED AS
PER ALSTOM SAS STANTERDISATION INPUT
SAS User Log In The through HMI 1 &2 Then Alarm to Be Send to ECC exept viewer SAS User Log In Alarm /
18 user account. Non Trip
System Normal
2. When any Unauthorized user try to log in to HMI 1 and HMI 2
send alarm to SCADA

1. All sources related to any internal faulty for Encryption module SAS Encryption Module
19 SAS Encryption Module faulty. Non Trip
FAULTY /Normal
2. Power supply module Encryption module
** In case of substation 380/132/13.8 and 380kV have separate gateway than 132kV. All SAS signals will be repeated by voltage level.
-SAS
TablePRINTER FAULTY/NORMAL
02-26: AMR/AMI & Revenue should be provided
Meter Panels Alarmsup to HMI
5. AMR/AMI Limit of Step Changed.
AMR/ AMI 6. AMR/AMI Control out Put changed.
AMR /REVENUE METER
1 /Revenue Meter Panels 7. AMR/AMI Filing of Meter Memory. Non-Trip Not applicable as per scheme.
8. AMR/AMI Password Failure. FAULTY/NORMAL
Alarm
9. AMR/AMI meter communication Failure.

Você também pode gostar