Williams Micropile Remedial Repair Underpinning Brackets
Williams
Williams Form Engineering Corp. offers underpinning Fastening
brackets for compression foundation remediation, ten- Hex Nut
sion/compression foundation remediation and floorslab
remediation applications. Compression foundation reme-
diation and tension/compression foundation remediation
brackets are offered in three sizes ranging from 20 kip
to 63 kip capacities where the bracket is attached to a
grouted micropile casing in medium stiff soils (N>4). The
Adjustment
unbraced length of micropile is minimum 5’; so per sec- Support
tion 1810.2.1 of IBC, a casing length of min 6’ is required Strap Bracket
to resist buckling and bending stresses. Brackets can be Seat
used in soft soils (N<4), however, the capacity may be
reduced as the unbraced length of the micropile would
be greatly increased in weaker soils. Please consult with Williams
a professional engineer to determine allowable working Grade 75
All-Thread
design load. Rebar

Compression Underpinning Bracket (C)


• Supports and raises existing foundations via connection to grouted micropile casing.
Bracket Sleeve Bracket Seat Bracket Casing
Bracket Bracket
Number Capacity Wall Bearing Wall Standard Yield
OD OD
Thickness Area Thickness Length Stress
20 kips 3-1/2” 1/4” 90 in² 2-7/8” 0.216” 6’ 65 KSI
WMS-MPB-20-C
(88.9 kN) (88.9 mm) (6.35 mm) (580 cm²) (73 mm) (5.49 mm) (1.83 m) (448 Mpa)
40 kips 5-9/16” 3/8” 90 in² 4-1/2” 0.438” 6’ 65 KSI
WMS-MPB-40-C
(178 kN) (141 mm) (9.53 mm) (580 cm²) (114 mm) (11.13 mm) (1.83 m) (448 Mpa)
63 kips 6-5/8” 0.432” 90 in² 5-9/16” 0.258” 6’ 36 KSI
WMS-MPB-63-C
(280 kN) (168 mm) (10.97 mm) (580 cm²) (141 mm) (6.55 mm) (1.83 m) (248 Mpa)

Tension/Compression Underpinning Bracket (TC)


• Supports and raises existing foundations via connection to grouted micropile casing.
• In tension, bracket requires a postive connection to the foundation through four 1” diameter concrete anchors bolts
designed to have adequate shear capacity from seismic and wind loads. To complete the tension load path, the
bracket must be positively connected to the micopile casing by field welding the bracket sleeve to the mircropile cas-
ing or by attaching shear bolts from the bracket sleeve through the micropile casing.
Bracket Sleeve Bracket Seat Bracket Casing
Bracket Bracket
Number Capacity Wall Bearing Wall Standard Yield
OD OD
Thickness Area Thickness Length Stress
20 kips 3-1/2” 1/4” 90 in² 2-7/8” 0.216” 6’ 65 KSI
WMS-MPB-20-TC
(88.9 kN) (88.9 mm) (6.35 mm) (580 cm²) (73 mm) (5.49 mm) (1.83 m) (448 Mpa)
40 kips 5-9/16” 3/8” 90 in² 4-1/2” 0.438” 6’ 65 KSI
WMS-MPB-40-TC
(178 kN) (141 mm) (9.53 mm) (580 cm²) (114 mm) (11.13 mm) (1.83 m) (448 Mpa)
63 kips 6-5/8” 0.432” 90 in² 5-9/16” 0.258” 6’ 36 KSI
WMS-MPB-63-TC
(280 kN) (168 mm) (10.97 mm) (580 cm²) (141 mm) (6.55 mm) (1.83 m) (0.25 Mpa)

See Williams’ “Ground Engineering Systems” for more information on corrosion protection and micropile reinforcing.

2
Floor Slab Underpinning Bracket (FS)
• Capacity of 11.7 Kips to support and raise existing slab-on grade concrete supported by grouted micropile.
• Bracket should be installed through a 10” diameter hole in the existing floor slab.
• Casing should be set at a sufficient height above the bracket sleeve such that the fastening nuts and support strap
are below the finished floor elevation after the slab has been raised.
• The spacing of the floor slab micropiles shall be the lesser of the slab punching shear capacity and the flexural
strength of the floor slab to span between the piles or the bracket capacity. Consult with a professional engineer to
determine the maximum spacing of the micropiles.
• Excavation under slab required.
Bracket Sleeve Bracket Seat Bracket Casing
Bracket Bracket
Number Capacity Wall Bearing Wall Standard Yield
OD OD
Thickness Area Thickness Length Stress
11.7 kips 3-1/2” 1/4” 40 in² 2-7/8” 0.216” 6’ 65 KSI
WMS-MPB-11.7-FS
(52 kN) (88.9 mm) (6.35 mm) (258 cm²) (73 mm) (5.49 mm) (1.83 m) (448 Mpa)

Compression Bracket Tension/Compression Bracket Floor Slab Bracket

Floor
Slab
Bracket

Compression Tension/
Bracket Compression
Bracket

Field Weld
After Final
Adjustment

Steel
Casing

Micropile
Reinforcing
Element

3
Please see web site for most current information
Web: www.williamsform.com
E-mail: williams@williamsform.com

Corporate Headquarters
8165 Graphic Dr.
Belmont, MI 49306
Ph: (616) 866-0815
Fax: (616) 866-1890
251 Rooney Road 2600 Vulcan Dr. 7601 North Columbia
Golden, CO 80401 Lithia Springs, GA 30122 Portland, OR 97203
Phone: (303) 216-9300 Phone: (770) 949-8300 Phone: (503) 285-4548
Fax: (303-216-9400 Fax: (770) 949-2377 Fax: (503) 285-6858
103 Kestrel Dr. 6440 Flanders Dr. 25232 74th Ave. South
Collegeville, PA 19426 San Diego, CA 92121 Kent, WA 98032
Phone: (610) 489-0624 Phone: (858) 320-0330 Phone: (253) 854-2268
Fax: (610) 489-0629 Fax: (858) 320-0360 Fax: (253) 854-2318

FORM HARDWARE & ROCK BOLT (Canada) LTD.


670 Industrial Road Laval, PQ Vernon, BC
London, ON, N5V 1V1 Ph: (450) 962-2679 Ph: (250) 306-0737
Ph: (519) 659-9444 Fax: (450) 962-2680 Fax: (519) 659-3623
Fax: (519) 659-5880
We have representation in the following organizations:

Você também pode gostar