Você está na página 1de 3

Model FFU160HAX Code 51320300098.

E
115-127V 60 1~ GENERAL DATA
Application: MBP
Refrigerant: R134a
Compressor Cooling: Fan
Type: Hermetic reciprocating
Technology Type: On-Off
Expansion Device: Capillary Tube / Expansion Valve
Packing Quantity: 100
Displacement: 12.92 cm3
Horse power: 1/2 hp

Approvals:

MECHANICAL DATA ELECTRICAL DATA


Bore: 28 mm Motor Type: CSIR
Stroke: 21 mm Starting Torque: LST/HST
Oil Charge: 350ml Voltage working range at 60 Hz: 104-140 V
Maximum Recommended Refrigerant Charge: 700 g Maximum Motor Temperature: 130 °C
Oil Type Configuration: ESTER Start Winding Resistance: 4.51 Ω (± 10%) at 25°C
Oil Type Viscosity: ISO22 Run Winding Resistance: 1.09 Ω (± 10%) at 25°C
Weight: 10.94 kg

MOUNTING ACCESSORIES ELECTRICAL COMPONENTS


Description Code Component type Description Code
Anchorage: no - CSR / CSIR Box: No
Starting Device: Relay 213516051*
Overload Protector no - Motor Protection: MST 18AFK -5590 13554029
Bracket:
Start Capacitor: 378-454UF - 165V 13556535
Capacitor Bracket: no -
Washer: no -
Pin: no -
Cover: no -
Grommets: no -
Sleeves: no -
Clip: yes 13143000
Terminal: yes 219109055

EXTERNAL CHARACTERISTICS
Base Plate: UNI V2
Tray Holder: No
Height: mm
Internal
Material Shape
Diameter (mm)
Suction Connector 8.2 Copper Straight
Discharge Connector 8.2 Copper Straight
Process Connector 6.5 Copper Straight

mktembraco@embraco.com Date of printing: 14.01.2019


Model FFU160HAX Code 51320300098.E
RATED POINT DATA

Gas Flow Rate


Cooling Capacity (kcal/h) Power Consumption (W) Current Consumption (A) Efficiency (kcal/Wh)
(kg/h)

±5% ±5% ±5% ±5% ±7%

1 534 657 7.32 35.44 2.34


Test condition: ASHRAE, Fan, Return Gas 35°C, Subcooling 8.3K, Evaporating: 7.2°C, Condensing: 54°C, Ambient: 35°C

PERFORMANCE CURVE DATA 115V 60Hz

Condensing Evaporating Cooling Power Consumption Current Gas Flow Efficiency


Temperature (°C) Temperature (°C) Capacity (kcal/h) (W) Consumption (A) Rate (kg/h) (kcal/Wh)

±5% ±5% ±5% ±5% ±7%

0 1 168 478 6.07 26.77 2.44


-5 956 436 5.64 21.81 2.19
35°C -10 773 395 5.30 17.55 1.96
-15 613 356 5.07 13.87 1.72
-20 472 321 4.93 10.65 1.47

Condensing Evaporating Cooling Power Consumption Current Gas Flow Efficiency


Temperature (°C) Temperature (°C) Capacity (kcal/h) (W) Consumption (A) Rate (kg/h) (kcal/Wh)

±5% ±5% ±5% ±5% ±7%

0 1 146 525 6.20 26.26 2.18


-5 930 475 5.78 21.23 1.96
45°C -10 750 426 5.46 17.05 1.76
-15 601 381 5.23 13.60 1.58
-20 478 342 5.08 10.78 1.40

Condensing Evaporating Cooling Power Consumption Current Gas Flow Efficiency


Temperature (°C) Temperature (°C) Capacity (kcal/h) (W) Consumption (A) Rate (kg/h) (kcal/Wh)

±5% ±5% ±5% ±5% ±7%

0 1 127 574 6.52 25.83 1.96


55°C -5 900 513 6.04 20.54 1.75
-10 716 455 5.66 16.26 1.57
Test condition: ASHRAE, Fan, Return Gas 35°C, Subcooling 8.3K, Ambient: 35°C

mktembraco@embraco.com Date of printing: 14.01.2019


OPERATING ENVELOPE
Model FFU160HAX Code 51320300098.E

Operating Condition
Transient Condition
Superheating

NOTE: usage of compressors outside of intended working range cannot make use of the warranty, or should be consulted with Technical
support.

mktembraco@embraco.com Date of printing: 14.01.2019