Escolar Documentos
Profissional Documentos
Cultura Documentos
RE
EXAM GUIDE
Building Systems
Overview 2
Knowledge / Skills
Sample Multiple-Choice Questions
3
7
Sample Multiple-Choice Answers 17
Mechanical & Electrical Plan Vignette 18
Sample Passing Solution 20
Sample Failing Solution 21
References 22
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
OVERVIEW
Knowledge/
Skills
3. PLUMBING
(10-15 percent of scored items)
4. HVAC
(18-23 percent of scored items)
5. ELECTRICAL
(10-15 percent of scored items)
6. LIGHTING
(15-20 percent of scored items)
7. SPECIALTIES
(18-23 percent of scored items)
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
KNOWLEDGE / SKILLS
Knowledge/
Skills
Sample Multiple- The division has been broken down into a listing of knowledge and skills directly related to each major content area.
Choice Questions
Mechanical &
Electrical Plan Vignette 1. CODES & REGULATIONS 4. Construction Details
(6-9 percent of scored items) Utilize sustainable and environmental design details and
References recognize their effect on constructability, aesthetics, and
A. Incorporate building codes, specialty codes, and technical properties.
other regulatory requirements in the design of mechanical, 5. Sustainable Design
electrical, plumbing, conveying, and other specialty systems. Utilize sustainable design principles in building design as it
1. Government and Regulatory Requirements and relates to basic engineering systems.
Permit Processes
6. Alternative Energy Systems and New Technologies
Interpret codes, protocols, and procedures of government
Evaluate sustainable strategies to utilize alternative energy
regulations to determine their impact on building design,
systems and evolving technologies in building design.
and construction.
7. Adaptive Reuse of Buildings and/or Materials
2. ENVIRONMENTAL ISSUES Evaluate sustainable strategies for adaptive reuse of
(9-11 percent of scored items) components, systems and/or materials in building design.
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
KNOWLEDGE / SKILLS
Knowledge/
Skills
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
KNOWLEDGE / SKILLS
Knowledge/
Skills
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
KNOWLEDGE / SKILLS
Knowledge/
Skills
Sample Multiple- 4. Construction Details and Constructability D. FIRE DETECTION AND SUPPRESSION
Choice Questions Utilize communications and security system details and Evaluate, select, and design fire detection and
recognize their effect on constructability, aesthetics, and suppression systems.
Mechanical & technical properties.
Electrical Plan Vignette 1. Building Design
C. CONVEYING SYSTEMS Apply basic engineering principles and technologies for fire
References Evaluate, select, and design elevators, escalators, moving detection and suppression systems in building design.
walkways, and other conveying systems.
2. Building Systems and their Integration
1. Building Design Evaluate and determine fire detection and suppression system
Apply basic engineering principles and technologies for parameters most appropriate for building design.
conveying systems in building design.
3. Implications of Design Decisions
2. Building Systems and their Integration Analyze and evaluate the implications of fire detection and
Evaluate and determine conveying system parameters most suppression system design decisions in relation project goals.
appropriate for building design.
4. Construction Details and Constructability
3. Implications of Design Decisions Utilize fire detection and suppression system details and
Analyze and evaluate the implications of conveying system recognize their effect on constructability, aesthetics, and
design decisions in relation to project goals. technical properties.
4. Construction Details and Constructability
Utilize conveying system details and recognize their effect on
constructability, aesthetics, and technical properties.
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 1. An office area has an average continuous lighting load of 4. In the single-line diagram of a typical electrical
Choice Questions 1,000 watts. What is the energy cost of providing lighting distribution system (below), which is the branch circuit?
to this area for a 12-hour day, based on a unit cost of 8 oA
Mechanical & cents per kilowatt-hour? oB
Electrical Plan Vignette
oC
References oD
dollars
dollars
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 7. Which of the following can be used most effectively to 10. The following graphs show monthly energy consumption
Choice Questions limit low-frequency sounds in an HVAC system? in kWh for four “all-electric” buildings located at
o Turning vanes 36° north latitude. If all four buildings have the same floor
Mechanical & o Duct lining area, which graph shows the building that will probably
Electrical Plan Vignette
o Mufflers benefit most from an energy-conserving retrofit that
References o Dampers emphasizes reduction of lighting energy?
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 12. When found in a building’s indoor air, carbon monoxide,
Choice Questions radon, formaldehyde, and nicotine are all classified as
o ventilation components
Mechanical & o hydrocarbon-fuel emissions
Electrical Plan Vignette
o building-materials emissions
References o indoor-air contaminants
o I and II only
o I and III only
o II and III only
o I, II, and III
o o
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple-
Choice Questions
Mechanical &
Electrical Plan Vignette
References
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 19. Which of the following is the term for the persistence of
Choice Questions sound reflected from surfaces of enclosed spaces?
o Creep
Mechanical & o Dampening
Electrical Plan Vignette
o Frequency
References o Reverberation
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 21. When a jurisdiction is governed by national, state, and 23. Which of the following HVAC systems would have the
Choice Questions local building codes, and provisions in at least two of these highest operating cost for a large office building?
codes conflict, which code takes precedence? o Single-zone, constant volume
Mechanical & o The local code o Variable air volume
Electrical Plan Vignette
o The state [provincial] code o Double-duct, constant volume
References o The national code o Constant volume reheat
o The most stringent or restrictive code
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 29. On a given site, which of the following would NOT be
Choice Questions relevant to life-cycle costing?
o Design fees
Mechanical & o Land costs
Electrical Plan Vignette
o Salvage value
References o Repair costs
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple-
Choice Questions 32. The sun is lowest in the sky in the northern hemisphere on
the day of the
Mechanical & o vernal equinox
Electrical Plan Vignette
o summer solstice
References o autumnal equinox
o winter solstice
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Mechanical &
Electrical Plan Vignette BAR
LAV. LAV. LAV. SINK
W.C.
TUB W.C.
References
LAV.
TUB W.C.
WALL
GRADE FLOOR
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
Sample Multiple- 39. The psychrometric chart plots which of the following 42. Which of the following terms are used in describing heat
Choice Questions factors? Check the two that apply. flow? Check the four that apply.
o A. Relative humidity o A. Convection
Mechanical & o B. Air motion o B. Conduction
Electrical Plan Vignette
o C. Mean radiant temperature o C. Suction
References o D. Air temperature o D. Radiation
o E. Convection current o E. Enthalpy
o F. Surface temperature o F. Conveyance
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
SAMPLE MULTIPLE-CHOICE ANSWERS
QUESTIONS Go to page 17 for answers.
Knowledge/
Skills
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
MECHANICAL & ELECTRICAL PLAN VIGNETTE
Knowledge/
Skills
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
MECHANICAL & ELECTRICAL PLAN VIGNETTE
Knowledge/
Skills
Sample Multiple- Comply with the following requirements to develop the HVAC System LIGHTING DIAGRAMS
Choice Questions reflected ceiling plan: The space is served by the supply and
return risers within the shaft indicated on
Mechanical & Suspended Ceiling System the floor plan. The HVAC system should
Electrical Plan Vignette
1. Provide a 2 ft X 4 ft grid with lay-in acoustical tiles provide for uniform air distribution with
References in all spaces. an economical duct layout conforming to
the following restrictions:
2. All ceiling heights are 9 ft above the finished floor. 1. Provide a minimum of one supply
diffuser and one return-air grille in
3. Typical walls terminate 6 inches above the finished ceiling; each space. An acceptable air
bearing walls and fire-rated walls extend to the bottom of distribution pattern includes one
the floor deck above. supply diffuser and one return-air
grille for every 144 ft² of floor area
Lighting System (or portion thereof) in each space. RECESSED FLUORESCENT RECESSED FLUORESCENT
Lighting layouts should be efficient and should minimize FIXTURE (2’X4’) END FIXTURE (2’X4’) SIDE
overlighting and underlighting. 2. Connect each supply diffuser to (Grid Units in Feet) (Grid Units in Feet)
1. For all spaces, use only recessed fluorescent fixtures to the rigid supply duct system with
provide uniform light distribution with a light level of flexible duct.
approximately 50 footcandles measured at desk level u Do not exceed 10 ft for
(3 ft above the finished floor). flexible duct lengths.
2. In addition to the fluorescent fixtures required above, 3. Return-air grilles are open to the
provide recessed accent light fixtures. ceiling space, which serves as a
u Locate the accent light fixtures along the west wall return-air plenum.
of the Architect’s Office so that the direct light level u Connect the plenum to the
on the wall at a height of 5 ft above the floor is 80 return riser with rigid duct.
footcandles.
u Space the accent light fixtures so that the light RECESSED FLUORESCENT RECESSED ACCENT FIXTURE
4. Protect duct openings in fire-rated
level between the fixtures at 5 ft above the floor is FIXTURE (2’X2’) (Grid Units in Feet)
walls with fire dampers.
(Grid Units in Feet) Distribution is the same all
80 footcandles.
Distribution is the same for sides around fixture
u The accent light fixtures should not be considered in 5. Flexible ducts fit through joist webs. and ends of fixture
determining the uniform light distribution levels.
u The recessed fluorescent fixtures should not be 6. Rigid ducts fit under beams, in spaces
considered in determining the accent light levels. between joists, and in a zone that extends 2 ft on either
side of beams and bearing walls in plan view.
u Rigid ducts do not fit through joists or between the
bottom of joists and the ceiling. July2014
October ARE® 4.0
2014ARE® 4.0 19
Building
Systems
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Procedural Tips
u F amiliarize yourself with the
Overview
MECHANICAL & ELECTRICAL PLAN VIGNETTE - Sample Passing Solution contents of each layer by turning
the layers on and off.
Knowledge/
Skills u here are three ways to realign a
T
ceiling grid.
Sample Multiple- w Use the move,adjust tool
Choice Questions and click anywhere within
Recessed accent the grid to shift the cells
Mechanical & within the perimeter of the
lighting is used
Electrical Plan Vignette grid rectangle.
where required
Rigid return duct by program. w Use the move,adjust tool
References only needs to and click on an edge of the
penetrate wall grid rectangle to increase or
as shown.
decrease the length or width
of the entire grid rectangle.
w Use the move group tool
and click on any part of the
grid to move the entire grid
rectangle elsewhere.
Correct use of fire
dampers in rated wall.
Correct separation u he rotate tool in this vignette
T
of supply diffusers works without the wand. To
and return-air grilles rotate an element:
shown throughout. w Click on the rotate icon.
w Click on the element you
want to rotate. If it is
Rigid ducts that rotatable, it will rotate 90
run perpendicular degrees every time you click
to joists must on it.
be within 2’-0”
of beam or
u he rotate tool will change the
T
bearing wall.
orientation of the ceiling grid.
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Tools You Might
Overview Find Useful
MECHANICAL & ELECTRICAL PLAN VIGNETTE - Sample Failing Solution u oom to help you lay out the
Z
ceiling grid
Knowledge/
Skills u F ull-screen cursor to help you line
up elements
Sample Multiple- Rigid duct is
Choice Questions shown greater
than 2’-0” from
Mechanical & steel beam.
Electrical Plan Vignette
Flex duct
References
connection
missing.
Single flex duct
cannot supply two
diffusers.
Lighting is spaced
too far apart.
The rigid duct runs perpendicular to the joists farther than is not connected by flex duct as required. In the Drafting
two feet from the beam along the north wall. The Conference Studio, the flex duct is also used to connect two supply
Room only has one supply diffuser and one return-air grille diffusers in a series which is prohibited by the program. The
when two of each are required by the area calculation given lights are spaced too far apart in some locations to achieve
in the program. The one supply diffuser provided in the the required lighting levels.
Reception/Secretary area sits directly under the rigid duct but
October 2014 ARE® 4.0 21
Building
Systems
95 MC Questions
+
BUILDING SYSTEMS
1 Vignette
Overview
REFERENCES
Knowledge/
The following references are presented to assist candidates in preparation for the examination. This list represents texts that
Skills
have content covered in this division of the examination. This is not intended to be an exhaustive list of all possible reference
Sample Multiple- materials for the subject area. NCARB makes no guarantee that the various references are currently in print.
Choice Questions
Mechanical & Architectural Graphic Standards Mechanical & Electrical Equipment for Buildings
Electrical Plan Vignette The American Institute of Architects Walter T. Grondzik, Alison G. Kwok, Ben Stein, and John S.
John Wiley & Sons, latest edition Reynolds, Editors
References
John Wiley & Sons, latest edition
ASHRAE Fundamentals Handbook
www.ashrae.org Mechanical and Electrical Systems in Buildings
2009 Richard R. Janis and William K. Y. Tao
Prentice Hall, latest edition
Heating, Cooling, Lighting: Sustainable Design
Methods for Architects
Norbert Lechner
John Wiley & Sons, latest edition