Você está na página 1de 5

ALLEGATO AL MOD.

ATTACHMENT TO FORM

Porto di visita Data della visita Pratica


Port of survey Date of survey File
Alexandria – EGYPT 19/11/2017 17 XE 171 01

Nome Nave NA/Q P-II Numero RINA


Name of ship RINA Number

Survey report for structure & LSA


The following recommendations were been found during my inspection on 19 November 2017 and to be
rectified.
A – Drawing and plan
The following Drawing and plans should be available on Platform
Punch Item Category Status
Operation manual (C) Closed
Technical procedure for underwater (C) Closed
survey
Under water survey scope of work from (C ) Closed
Abu qir
Structure arrangement of platform ( C) Closed
Jacket structure and relevant ( C) Closed
appurtenances above water line.
Jacket structure and relevant (C ) Closed
appurtenances below water line.
Jacket foundation plan ( C) Closed
Main deck and cellar deck Plan. ( C) Closed
Anodes plans ( C) Closed
MPI for Critical area (C ) Open
Previous Wall thickness measurements ( C) Closed
Annual service for safety and ( B) Closed
firefighting equipment.
Recommendation from last underwater (B) Open
inspection shall be implemented during

Form VISITE 2 – 02/2015 Questo allegato e’ composto di 5 pagina/e


This attachment consist of page(s)
next offshore campaign

B- Safety and firefighting Equipment


Miscellaneous recommendations:
Punch Item Category Status
Test to be carried out for safety net iwo ( B) Closed
helideck.
Self-closing device for Fire door iwo ( B) Closed
Accommodation to maintained.
Refracted tab for Life buoys to be ( B) Closed
renewed, damage ropes to be provided,
Expired MOB to be renewed, further
more names to be posted on life buoys.
Annual Service and hydrostatic tests of ( B) Closed
old portable Firefighting Extinguishers
to be carried out by approved Service
suppliers
Annual Service and 5 years hydrostatic ( B) Closed
tests of fixed Firefighting Extinguishers
(FM200) to be carried out by approved
Service suppliers.
Life Jackets without light and whistle. (B) Closed
Service report for life rafts and ( B) Closed
hydrostatic release to be provided.
Update Safety and fire plan to be ( B) Closed
provided on board, Verification of
Equipment on board to be carried out
according to safety and fire plan.
Annual test of breathing apparatus to be ( B) Closed
carried out by approved Service
suppliers.
Safety and Fire Symbols to be posted ( B) Closed
according to Fire and safety plan.
Radio Station license to be provided in ( B) Closed
order to check Communication
equipment.
Filters or air Masks for crew iwo ( B) Closed
accommodation and work station are
expired since 2016.
Protection glass iwo Fixed powder fire (B) Closed
extinguisher iwo helideck found
missing, to be provided.
Box for release fixed foam iwo helideck, ( B) Closed

Form VISITE 2 – 02/2015 Questo allegato e’ composto di 5 pagina/e


This attachment consist of page(s)
glass found damage, to be renewed.
Fixed powder fire extinguisher iwo ( B)
helideck North found out of
service, to be repaired.
Control valve iwo foam tank main deck ( B)
found inoperative and stuck, to be
repaired and tested.
Missing fire extinguishers iwo galley to (B)
be provided.

Refracted tab for Life buoys to be renewed, damage Life Jackets without light and whistle.
ropes to be provided, Expired MOB to be renewed,
further more names to be posted on life buoys.

Filters or air Masks for crew iwo accommodation and Protection glass iwo Fixed powder fire extinguisher
work station are expired since 2016. iwo helideck found missing, to be provided.

Form VISITE 2 – 02/2015 Questo allegato e’ composto di 5 pagina/e


This attachment consist of page(s)
Box for release fixed foam iwo helideck, glass found Self-closing device for Fire door iwo
damage, to be renewed. Accommodation and work stations to maintained.

Annual test of breathing apparatus to be carried out Control valve iwo foam tank main deck found
by approved Service suppliers. inoperative and stuck, to be repaired and tested.

C – Recommendation iwo Structure.


Punch Item Category Status
2 Handrail for ladder iwo boat landing
found damage, to be renewed. (C) Closed
Missing or wasted grill floor iwo boat
landing to be renewed. ( C) Closed

Form VISITE 2 – 02/2015 Questo allegato e’ composto di 5 pagina/e


This attachment consist of page(s)
2 Handrail for ladder iwo boat landing found Missing or wasted grill floor iwo boat landing to be
damage, to be renewed. renewed.

D – Recommendation iwo Under water Survey


Punch item Punch Category Status
Underwater Survey to be Wittiness (C) Closed
by RINA surveyor.
NDT to be Wittiness by RINA ( C) Closed
surveyor.
Thickness measurement to be ( C) Closed
Wittiness by RINA surveyor.

Note: The status of punch items in this report has been updated based on exchange
communications and emails between AQP&RINA not based on survey.
Data: 19/11/2017
Date

_____________________________________________
Nome e firma del Tecnico RINA SERVICES S.p.A.
RINA SERVICES S.p.A. Surveyor name and signature

Form VISITE 2 – 02/2015 Questo allegato e’ composto di 5 pagina/e


This attachment consist of page(s)