ROSA Detailed Report Page 1 of 3

Reverse Osmosis System Analysis for FILMTEC™ Membranes ROSA 9.1 ConfigDB u399339_282
Project: Enerau - Hydro Case: 1
NP, mft 10/25/2018

Project Information: Diary WWTP

Case-specific:

System Details

Feed Flow to Stage 1 159.10 m³/h Pass 1 Permeate Flow 55.37 m³/h Osmotic Pressure:
Raw Water Flow to System 79.10 m³/h Pass 1 Recovery 70.00 % Feed 5.64 bar
Feed Pressure 22.40 bar Feed Temperature 30.0 C Concentrate 17.51 bar
Flow Factor 0.85 Feed TDS 9017.06 mg/l Average 11.57 bar
Chem. Dose (100% H2SO4) 0.00 mg/l Number of Elements 120 Average NDP 4.12 bar
Total Active Area 4459.20 M² Average Pass 1 Flux 12.42 lmh Power 123.74 kW
Water Classification: Wastewater with Generic membrane filtration, SDI < 3 Specific Energy 2.23 kWh/m³

Feed Flow Feed Press Recirc Flow Conc Flow Conc Press Perm Flow Avg Flux Perm Press Boost Press Perm TDS
Stage Element #PV #Ele
(m³/h) (bar) (m³/h) (m³/h) (bar) (m³/h) (lmh) (bar) (bar) (mg/l)
1 XFRLE-400/34i 20 6 159.10 18.40 80.00 103.73 17.96 55.37 12.42 0.00 0.00 699.87

Pass Streams
(mg/l as Ion)
Adjusted Feed Concentrate Permeate
Name Feed
Initial After Recycles Stage 1 Stage 1 Total
NH4+ + NH3 0.00 0.00 0.00 0.00 0.00 0.00
K 0.00 0.00 0.00 0.00 0.00 0.00
Na 3217.05 3217.05 6723.89 10180.46 248.31 248.31
Mg 0.00 0.00 0.00 0.00 0.00 0.00
Ca 0.00 0.00 0.00 0.00 0.00 0.00
Sr 0.00 0.00 0.00 0.00 0.00 0.00
Ba 0.00 0.00 0.00 0.00 0.00 0.00
CO3 0.00 0.00 0.00 0.00 0.00 0.00
HCO3 0.00 0.00 0.00 0.00 0.00 0.00
NO3 250.00 250.00 447.38 639.31 87.82 87.82
Cl 2750.00 2750.00 5713.62 8632.68 245.03 245.03
F 0.00 0.00 0.00 0.00 0.00 0.00
SO4 2800.00 2800.00 5956.54 9072.68 118.71 118.71
SiO2 0.00 0.00 0.00 0.00 0.00 0.00
Boron 0.00 0.00 0.00 0.00 0.00 0.00
CO2 0.00 0.00 0.00 0.00 0.00 0.00
TDS 9017.06 9017.06 18841.43 28525.13 699.87 699.87
pH 7.00 7.00 7.00 7.00 7.00 7.00

*Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical Company
assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ
from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s use. FilmTec Corporation
and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer should be sued for alleged
infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/Enerau%2... 26/10/18
ROSA Detailed Report Page 2 of 3

Reverse Osmosis System Analysis for FILMTEC™ Membranes ROSA 9.1 ConfigDB u399339_282
Project: Enerau - Hydro Case: 1
NP, mft 10/25/2018

Design Warnings

-None-

Solubility Warnings

-None-

Stage Details

Stage 1 Element Recovery Perm Flow (m³/h) Perm TDS (mg/l) Feed Flow (m³/h) Feed TDS (mg/l) Feed Press (bar)
1 0.10 0.83 336.08 7.95 18841.43 18.40
2 0.09 0.63 477.94 7.13 20984.30 18.30
3 0.07 0.47 676.33 6.50 22968.04 18.22
4 0.06 0.36 942.51 6.03 24718.78 18.15
5 0.05 0.27 1278.77 5.67 26212.41 18.08
6 0.04 0.21 1674.50 5.40 27467.55 18.02

Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical Company
assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ
from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s use. FilmTec Corporation
and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer should be sued for alleged
infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/Enerau%2... 26/10/18
ROSA Detailed Report Page 3 of 3

Scaling Calculations

Raw Water Adjusted Feed Concentrate


pH 7.00 7.00 7.00
Langelier Saturation Index -16.56 -16.56 -15.66
Stiff & Davis Stability Index -17.05 -17.05 -16.58
Ionic Strength (Molal) 0.17 0.17 0.55
TDS (mg/l) 9017.06 9017.06 28525.13
HCO3 0.00 0.00 0.00
CO2 0.00 0.00 0.00
CO3 0.00 0.00 0.00
CaSO4 (% Saturation) 0.00 0.00 0.00
BaSO4 (% Saturation) 0.00 0.00 0.00
SrSO4 (% Saturation) 0.00 0.00 0.00
CaF2 (% Saturation) 0.00 0.00 0.00
SiO2 (% Saturation) 0.00 0.00 0.00
Mg(OH)2 (% Saturation) 0.00 0.00 0.00

To balance: 0.00 mg/l Na added to feed.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/Enerau%2... 26/10/18