Você está na página 1de 2

siemens.

com/perfect-places
#CreatingPerfectPlaces

that’s Ingenuity for life.


When building technology creates perfect places –

For every stage of life.

our aim is to create perfect places.


With our people and technology, our products and services,

you improve their lives.


Improve the places where they spend their lives and

People spend about 90 percent of their time indoors.


are binding only when they are expressly agreed upon in the concluded contract.
course of further development of the products. The requested performance features
specifically reflect those described, or which may undergo modification in the
contains general descriptions and/or performance features which may not always
Subject to changes and errors. The information given in this document only
BT_00157_EN (Status 05/2018)
siemens.com/cerberus-pace
Controlled Evacuation
Cerberus PACE
Public Address and

Planning Tool
Introducing Cerberus PACE System configuration in three steps with PACE-Design
For the convenient setup and management of all components, Cerberus PACE comes with the dedicated configuration software
PACE-Design. It provides an overview and control of all relevant functions. With PACE-Design, Cerberus PACE can be configured in a 3-step
process. No system restarts are required throughout this process.

Your benefits at a glance

B
1 2 3
Beyond EN 54-16 Multi-redundancy Real-time engineering
Regulatory compliance Maximum system System configuration
and much more thanks reliability with without restarts ensures
to state-of-the-art redundant components business continuity at all
technology up to complete double times
The sound of safety structure PACE PACE
Design Design
Cerberus PACE – Public Address and Controlled Evacuation

In commercial and public buildings, life safety must always be the highest
priority. Effectively moving people out of harm’s way in case of an emergency is
largely a matter of communication – which is why public address and voice
alarm (PA/VA) systems in these buildings aren’t just a useful tool for
announcements, entertainment or live moderation but an integral part of the
safety infrastructure.
Connect a PC or laptop running All network elements will be Configure the system and the
With Cerberus PACE, you can cover all your PA/VA needs with a single solution. It PACE-Design to the desired network automatically loaded into PACE-Design corresponding in- and outputs.
was designed with the specific convenience and emergency applications in Pro Sound Step-by-step Loop isolators switch (PACE-NET) via Ethernet. and appear immediately on the screen.
modern businesses and organizations in mind, from ambient music to public High-quality, low-latency modernization Failsafe loop isolators
speaking to guided evacuation. Thanks to its state-of-the-art modular and speaker output for Smooth system thanks to omission of
scalable system architecture, Cerberus PACE can be customized for optimum intelligibility implementation with error-prone capacitors
buildings of all types and sizes and offers unique benefits that will reliably and comfortable addressable end-of-line
ambience modules
ensure the safety and comfort of your employees, visitors and guests 24/7.

Multi-redundancy Step-by-step modernization


Maximum reliability is a key prerequisite for safety-critical systems including voice alarm systems. To ensure failure safety for all There is no need to start from scratch if you have an outdated or broken PA/VA system. Cerberus PACE offers step-by-step modernization,
applications, Cerberus PACE can incorporate all redundancy levels from individual backup components up to a complete double keeping legacy speaker line structures including speakers to achieve EN 54-16 compliance and modern functionality. The key is the
structure. Moreover, the network can be made redundant by expanding the EN 54-16 standard single loop network topology to a installation of smart end-of-line (EOL) modules that identify any faults. In this way, you can safeguard past investments and stretch the
double loop / double tree topology or combinations thereof. new ones out over time.

1 2 3
Single loop 1 Standard EN 54-16 with B-wiring 2 Standard EN 54-16 with A/B-wiring

network PN PN

PC PC
B
Double loop PN
B
a

network PC
3 EN 54-16 with A/B-wiring, 4 EN 54-16 with A/B-wiring,
redundant audio matrix redundant audio matrix and switch

PN PN PN
Third-party Cerberus PACE Cerberus PACE
PC PC PC PC PA/VA system
B B
a a

Double tree 5 EN 54-16 with A/B-wiring,


network PN
PN
redundant cabinet

PN PN
PC
6 EN 54-16 with A/B-wiring,
redundant cabinet and network Old or defective PA/VA system
PC PC EN 54-16 compliance State-of-the-art PA/VA topology
PN PN
B
The initial situation usually involves a In the first modernization stage, the new In the final step, the tree structure of the
PN PN a third-party PA/VA system that was built central audio components are implemented speaker lines is replaced with the more
PC PC in compliance with outdated standards and end-of-line (EOL) modules added to the resilient stub structure including the
and is possibly malfunctioning. existing speaker lines. corresponding speakers.
B
PN Ethernet switch
a Digital audio matrix
PC
Increased redundancy with double loop or double tree
Cerberus PACE system overview

Ethernet switch 100 m Ethernet switch


Fire protection system
Speaker line structure options
100 m e.g. Cerberus PRO
incl. FOI adapter incl. FOI adapter
100 m
PN2005 PN2005
Ethernet switch
incl. FOI adapter Desk call
Stub
PACE-Design PN2005 station B-wiring B
PT2001 Input/output EOL
Digital audio module FDCIO222
Legend
100 m matrix
PC2003 PACE-NET

Power RS485 BUS A/B-wiring a


Network EOL
System state amplifier Input/Output extension RS232
control panel
indicator PV2003 digital PCIO2001
Media 24 V DC line
PT2004
converter Fibre optic Digital audio Analog audio line
B
Alarm control PN2007 connection matrix Switching line EOL
panel PC2001 Phanton power
PT2005
Fault contact
Output extension
C-NET
DC/DC 150 m relay PCO2001
converter
PCA2011
Tree
DC/DC Ground fault EOL
Ground fault Desk call station Desk call converter monitoring
monitoring interface PT2008 station PT2008 DC/DC Ground fault PCA2011 PCA2001
EOL
PCA2001 converter monitoring
PCA2011 PCA2001 Digital audio 500 m
Repeater
Digital audio matrix
(CAT5) EOL
matrix PC2003
PNA2007
PC2001 Desk call station
Desk station (analog) PT2009
500 m interface PTO2007
EOL
Remote EOL
Power control panel
amplifier PT2006
PV2003

Power Power
Fire brigade
Power Loop
supply supply supply Automatic volume
PP2003 PP2003 call station PP2003 controle module
PT2002 PCA2008
Battery Battery
Battery PA2007 PA2007 Loop Isolator
Automatic volume
PA2007 control microphone
PCA2007

550 m or 10 km (depending on FOI adapter)

Base components Network and power components


Call stations Network switches

- Alerting and business call


station
- Fully featured network
system component
- Gooseneck microphone Ethernet switch (1x 8/2) FOI adapter FOI adapter FOI adapter Ethernet switch (2x 4/2) Media converter (1x 1/1)
- Microphone and line PN2005 PNA2002 PNA2003 PNA2004 PN2001 PN2007
monitoring - Network switch with 8 - Switch FO module - Switch FO module - Fiber optic interface multi - Double switch with 8 - 1 Ethernet port and
- Redundant cable connection Ethernet and 2 modular - Fiber optic interface single - Fiber optic interface multi mode adapter needed to Ethernet (2x 4 ports) and 1 modular FO port
Desk call station - Integrated 2 GB memory Desk call station Desk call station Desk call station Desk call station Desk call station FO ports (optional ring mode mode connect to PN2001 LC 2 FO ports Order no.: S54451-B44-A1
(19 buttons) PT2001 card for texts extension extension (Kaba) (RS485, 8+1) PT2009 extension (RS485, 8) (analog, 3+1) PT2008 topology) - Up to 10 km - Up to 550 m connector - No spanning tree
Order no.: S54451-B6-A1 - 2 analog mic/line inputs (24 buttons) PTO2001 PTO2002 - Business call station for PTO2006 - Business call station for Order no.: S54451-B5-A1 - LC connector - LC connector Order no.: S54451-B39-A1 Order no.: S54451-B4-A1
- Integrated loudspeaker - Max. 4 extensions per Order no.: S54451-B8-A1 non-alarm applications only - For external housing or non-alarm applications only Order no.: S54451-B38-A1 Order no.: S54451-B41-A1
- 2-row text display (no call station (EN 54-16 certificate pending) custom applications (no EN 54-16)
customer information) Order no.: S54451-B7-A1 - 2x RS485 interface / 500 m - EN 54-16 certificate - Gooseneck microphone
- 19 freely configurable keys - Gooseneck microphone pending - Includes interface needed
- Power supply: 24 VDC / - Microphone and line Order no.: S54451-B51-A1 to connect to PC2001 or
200 mA monitoring PC2003
- 8 freely configurable keys Order no.: S54451-B32-A1 Power supply Power amplifiers
- PTO2008 needed to connect
to PC2001 or PC2003
Order no.: S54451-B33-A1

Power supply (19", 320 Ah) Power supply (wall-mounted, 40 Ah) Power amplifier Power amplifier Power amplifier
Control panels PP2003
- Output: 400 W @ 24 VDC
PP2004
- Output: 125 W @ 24 VDC
PV2007
- Power supply: 230 VAC and 24 VDC
PV2001
- Power supply: 230 VAC and 24 VDC
PV2003
- Power supply: 230 VAC and 24 VDC
- 24 V outputs to amplifiers: 6x 30 A - Wall-mounted remote power supply (no fans or moving parts) (no fans or moving parts) (no fans or moving parts)
- 24 V output other: 2x 10 A and charger - 1x 250 W output power - 2x 250 W or 1x 500 W (in bridge - 4x 150 W or 2x 300 W (in bridge
- Monitoring: input/output, battery - Monitoring: input/output, battery Order no.: S54451-B34-A1 mode 100 V only) output power mode 100 V only) output power
- Max. battery capacity: 24 V / 320 Ah - Max. battery capacity: 24 V / 40 Ah Order no.: S54451-B15-A1 Order no.: S54451-B17-A1
Order no.: S54451-B61-A1 Order no.: S54451-B62-A1

System state indicator (door) System state indicator (19") Alarm control panel (19") Remote control panel Fire brigade call station
PT2007
- Display: operation, fault, voice
PT2004
- Display: operation, fault, voice
PT2005
- Trigger keys: voice alarm, reset,
PT2006
- For non-alarm applications only
(AT) PT2002 Batteries
alarm - Monitored microphone
alarm mute (no EN 54-16)
Order no.: S54451-B11-A1 - Memory for 6 text messages
- For external housing or custom Order no.: S54451-B12-A1 - Zone regulation in UP version
- Network connection via
applications - Programmable functions for the
2x Cat5
Order no.: S54451-B14-A1 respective zone: volume control,
- Power supply: 24 VDC /
preset selection, selection of
260 mA
audio input source (CD, tuner) Battery (12 V, 40 Ah) Battery (12 V, 65 Ah) Battery (12 V, 100 Ah) Battery (12 V, 150 Ah) Battery tray (19")
Order no.: S54451-B9-A1
Order no.: S54451-B13-A1 PA2006 PA2007 PA2008 PA2009 PHA2007
Order no.: S54451-B68-A1 Order no.: S54451-B69-A1 Order no.: S54451-B70-A1 Order no.: S54451-B71-A1 Order no.: S54451-B42-A1

Digital audio matrix


Shared properties: Accessories
8 digital inputs and outputs
Digital audio matrix (4/4/4) Digital audio matrix (0/4/4) Digital audio matrix (4/4/16)
1 interface (RS-232 or RS-485) PC2001 PC2002 PC2003
Slot for 2GB microSD flash card - Zone amplification (4 zones)
- 4 analog audio inputs and outputs
- Zone amplification (4 zones)
- 4 analog audio outputs
- Zone and bulk amplification Power supply Call station Audio file storage
Digital signal processing (DSP) (16 zones)
- 8 analog measuring inputs (no audio Inputs) - 4 analog audio inputs and outputs
Fault relay - Power supply: 24 VDC / 370 mA - 8 analog measuring inputs - Power supply: 24 VDC / 500 mA
Order no.: S54451-B1-A1 - Power supply: 24 VDC / 370 mA (with pilot tone 5 A)
Order no.: S54451-B2-A1 Order no.: S54451-B3-A1

Ground fault monitoring DC/DC converter Desk call station interface Gooseneck microphone Mounting kit DCS 2 GB SD card (industrial)
(24 V) PCA2001 (24 V / 50 W) PCA2011 (8+1) PTO2008 DCS PTO2004 (19” / 5 HU) PTO2005 PCA2002

Cabinets - Monitoring of 24 V lines for


ground fault, e.g. in case of
remote call stations
- DC/DC converter for galvanic
isolation of the 24 V line
Order no.: S54451-B65-A1
- Needed to connect PT2009
to PC2001 or PC2003
Order no.: S54451-B58-A1
Order no.: S54451-B49-A1 Order no.: S54451-B50-A1 Order no.: S54451-B58-A1

Order no.: S54451-B19-A1

Available ERA Rittal


options Automatic volume control Input/output Network
60x60 80x80 80x80

PH2012 PH2010 PH2006


Fixed frame 26 HU 26 HU 24 HU
small Order no.: S54451-C20-A1 Order no.: S54451-C50-A1 Order no.: S54451-C40-A1

Automatic volume control Automatic volume control Input/output extension digital (16) Output extension relay (8) Repeater (CAT5)
microphone PCA2007 module PCA2008 PCIO2001 PCO2001 PNA2007
PH2011 PH2009 PH2005
Fixed frame 43 HU 43 HU 42 HU - Supplied with phantom - Connection via audio input 4 - 16 additional digital inputs and outputs - 8 additional relay outputs - Extend the length of one Ethernet
Order no.: S54451-C21-A1 Order no.: S54451-C52-A1 Order no.: S54451-C42-A1 power via PCA2008 - Use with PC2001 and PC2003 - 8 analog inputs - Connection via RS232 connection from 100 m to 200 m
large Order no.: S54451-B25-A1 - Can connect up to 4 PCA2007 - Connection via RS485 - Use with PC2001, PC2002 and PC2003 - 100 MBit/s Ethernet network
Order no.: S54451-B26-A1 - Use with PC2001, PC2002 and PC2003 - Relay contact: Max. 7 A expansion (more than 100 m)
Order no.: S54451-B28-A1 Order no.: S54451-B27-A1 - 4x Ethernet port
PH2008 PH2004 - 1x FO fiber: multimode, 1310 nm
Swivel frame 23 HU 24 HU (SC connector)
Order no.: S54451-C51-A1 Order no.: S54451-C41-A1 - 24 V input
small Order no.: S54451-B52-A1
End-of-line (EOL) module Loop isolators
PH2007 PH2003 - Active loop isolator
Swivel frame 40 HU 40 HU device for speaker lines
large Order no.: S54451-C53-A1 Order no.: S54451-C43-A1 - Opens speaker line loop
in case of short circuit
- Up to 80 loop isolators
EOL3 (active) PCA2004 Loop isolator (100 V) per speaker line loop Loop isolator LED Loop isolator box
PH2013 Cabinet (swivel frame small) Cabinet (swivel frame large) - Active end-of-line device for speaker PCA2005 - Only PC2003 supports PCA2012 PCA2013
13 HU lines Order no.: S54451-B53-A1 loop isolators Order no.: S54451-B55-A1 Order no.: S54451-B54-A1
Wall mount Order no.: S54451-C29-A1 - Up to 16 modules per amplifier
- Use with PC2001, PC2002 and PC2003
Order no.: S54451-B22-A1
Legend: HU = Height Unit

Você também pode gostar