CONVERTIBLE TOP
REPAIR & ADJUSTMENT
MANUAL
CONVERTIBLE TOP
OPERATION
AND
SCHEMATIC
DIAGRAMS
A PRODUCT OF
MOTOR COMPANY
TABLE OF CONTENTS
PAGE NO.
DESCRIPTION AND OPERATION 4
ELECTRICAL SYSTEM 5
HYDRAULIC SYSTEM 6
Deck Open Cycle 6
Top Up Cycle 6
Deck Close Cycle 8
Top Down Cycle 8
SCHEMATIC DIAGRAMS 10
TOP RETRACT CYCLE
Deck Lid Unlock IQ
Deck Lid Open ||
Upper Bock Panel Erect 12
Top Unlock 13
Top Retract I4
Deck Lid Close and Lock 15
TCP ERECT CYCLE
Deck Lid Unlock 16
Deck Lid Open 17
Top Erect . I8
Top Lock 19
Upper Back Panel Retract 20
Deck Lid Close and Lock 21
TOP UP LIMIT SWITCH - FRONT
TOP LOCK MOTOR
DECK CONTROL
SOLENOID
The top can be stopped at any time in either cycle (retract or erect) simply by
releasing the top control switch. When the top control switch is released, the
solenoid valves, which are connected to the hydraulic pressure lines, close and
prevent further movement of the top assembly until the circuit is reactivated by
moving the top control switch. Do not attempt to manually force the top or deck
lid either up or down.
ELECTRICAL SYSTEM
The electrical system includes four reversible motors; the top lock motor that
drives two hook locking rods that lock and unlock the top to the windshield
header; the upper back panel motor that drives the upper back panel by a small
transmission; the deck lock motor that locks and unlocks the deck lid through
flexible drive cables; and the top-deck motor that drives a hydraulic pump which
supplies hydraulic fluid pressure to open and close the deck lid and the top
assembly.
There are 11 relays; the top control neutral relay is used as a safety device
in the control circuit. This relay is located on the mounting plate located behind
the right front fender splash shield. The control circuit cannot be energized
until the top control neutral relay contacts are closed. The circuit is complete
only when the neutral switch is closed. The circuit is closed when the trans
mission: selector lever is in P or N and the ignition switch is in the ACC or ON
positiorf. The control circuit to the top control switch is identical for both the
top retract cycle and top erect cycle. Current flows from the ignition switch,
through the top control neutral relay, the transmission neutral switch, and the
starter motor relay to ground. The top control neutral relay is energized, closing
the relay contacts, and current flows from the 10-ampere circuit breaker through
the top control switch.
The remaining 10 relays are used to energize the motors and the three solen
oids.
The deck lid and convertible top ossembly ore eoch operoted by two hydrouiic
cylinders, receiving pressure from one electricolly powered reversible motor
ond pump. The hydrouiic fluid pressure is controlled by three electricolly octi-
voted solenoid volves, two for the top ossembly, ond one for the deck lid.
DECK LID
HYDRAULIC CYLINDERS
PRESSURE
RETURN
DECK CONTROL
SOLENOID OPEN
FOR DECK OPEN CYCLE
DECK OPEN
CYCLE
TOP UP
CYCLE
TOP AND DECK MOTOR
NOTE MOTOR ROTATION CLOCKWISE
FOR THESE TWO CYCLES.
FOLDING TOP
HYDRAULIC CYLINDERS
TOP CONTROL
SOLENOIDS OPEN
FOR TOP UP CYCLE TOP UP CYCLE
(ERECT)
The cycle can be stopped at any time by release of the control switch opening
the circuit to the deck open relay. The open circuit stops the pump motor and
automatically closes the deck solenoid.
The cycle can be stopped at any time by release of the control switch opening
the circuit to the top up relay. The open circuit stops the pump motor and auto
matically closes the top solenoids.
HYDRAULIC SYSTEM
PRESSURE
RETURN
rtprv I in
DECK CONTROL
SOLENOID OPEN
FOR DECK CLOSE CYCLE
NOTE:
MOTOR ROTATION FOLDING TOP
COUNTERCLOCKWISE FOR HYDRAULIC CYLINDERS
THESE TWO CYCLES.
TOP CONTROL
SOLENOIDS OPEN
FOR TOP DOWN CYCLE TOP DOWN CYCLE
(RETRACT)
The cycle con be stopped at any time by release of the control switch opening
the circuit to the top down relay. The open circuit stops the pump motor and auto
matically closes the top solenoids.
TOP RETRACT CYCLE
NEUTRAL I DECK
SWITCH If UNLOCK
RELAY
15-AMP
CIRCUIT
BREAKER DECK OPEN
STARTING MOTOR LIMIT SWITCH
RELAY
With the top control switch in the top down position, current flows from the top
control switch, through the upper back panel limit switch, the deck open limit
switch, (#1 for 1964) and the deck unlock relay coil to ground. The deck un
lock relay coil is energized, closing the relay contacts which complete the
power circuit from the 50-ampere circuit breaker, through the 15-ampere circuit
to the deck lock motor. The motor is energized and the deck lid i s unlocked.
RELAY PAHEL CIRCUIT BREAKER
PANEL DECK CLOSED UPPER BACK PANEL
LIMIT SWITCH LIMIT SWITCH
WIRING COLOR CODE
V - VIOLET
B - BLACK
DECK
R -
RED SOLENOID
0 -
ORANGE
BL -
BLUE
y.V -
YELLOW - VIOLET
STRIPE
O-B - ORANGE • BLACK TOP AND DECK MOTOR
STRIPE
TOP CONTROL SWITCH
R-Y - RED - YELLOW
PUSHED DOWN
STRIPE DECK LOCK
DECK
O.BR - ORANGE • BROWN MOTOR
OPEN
STRIPE RELAY DECK
BL-R - BLUE . RED STRIPE UNLOCK DECK OPEN LIMIT SWITCH
R-BL-RED-BLUE STRIPE RELAY 11 for 1964
BL-G - BLUE -GREEN STRIPE
TO BATTERY
TERMINAL
As soon OS the deck lid is unlocked, the deck closed limit switch contacts
are repositioned. The current now flows from the top control switch through the
upper bock panel limit switch, through the deck open limit switch, (# 1 for 1964)
through the deck closed limit switch and the deck open relay coil to ground.
This closes the deck open relay multiple contacts which complete the power
circuits from the 50-ampere circuit breaker to the top and deck motor and the
deck solenoid valve.
The deck solenoid valve is energized and the proper hydraulic lines are opened
to the deck lift cylinders. At the same time, the top and deck motor is energized
and the deck lid is opened. The deck locks continue to operate until the deck is
completely open.
WIRING COLOR CODE
CIRCUIT BREAKER
RELAY PANEL PANEL
V - VIOLET
UPPER BACK PANEL
R - RED
ERECT RELAY
BL-BLUE UPPER BACK PANEL
OR - GREY LIMIT SWITCH
BL-G-BLUE-GREEN
STRIPE
BL-0 - BLUE - ORANGE
STRIPE
BL-R - BLUE • RED
UPPER BACK
STRIPE
'PANEL MOTOR
BL-W - BLUE - WHITE
STRIPE
B-BL - BLACK • BLUE
STRIPE
TO JUNCTION BLOCK —O
DOWN
UPPER BACK 1
PANEL MOTOR'
DECK OPEN
LIMIT SWITCH
O I 0
When the deck lid is completely open, the plunger of the deck open limit switch
is depressed and the switch contacts are repositioned. The current now flows
from the top control switch, through the deck open limit switch (#1 for 1964)
the upper back panel limit switch, and the upper back panel erect relay coil to
ground. The upper back panel relay contacts close and the power circuit is
completed from the 50-ampere circuit breaker through the 15-ampere circuit break
er to the upper back panel motor. The motor is energized and the upper back
panel is erected.
CIRCUIT BREAKER PANEL
RELAY PANEL
15.AMP
CIRCUIT BREAKER ^-Y
TO BATTERY
TERMINAL ^
TOP
SO-AMP BUS BAR UNLOCK
CIRCUIT BREAKER RELAY
TOP UNLOCK
LIMIT SWITCH
TOP UNLOCK
As soon OS riie upper bock pone) is in the erect position, the upper bock panel
limit switch is actuated and the switch contacts are repositioned. The current
now flows from riie top control switch, through the top unlock limit switch, the
upper back panel limit switch and the top unlock relay coll to ground. The relay
contacts close and complete the power circuit from the 5(^ampere circuit breaker
through the 15-ampere circuit breaker to the top lock motor. The motor is ener
gized and the top is unlocked.
WIRING COLOR CODE TOP UNLOCK LIMIT SWITCH
R - RED CIRCUIT BREAKER PANEL
Y - YELLOW RELAY PANEL,
W - WHITE
V - VIOLET
BL - BLUE
W.BL - WHITE - BLUE
TOP DOWN
STRIPE RELAY
Y-W - YELLOW - WHITE
STRIPE
V-W - VIOLET - WHITE
STRIPE
TOP SOLENOIDS
TO BATTERY
TER^NAL BL BL
P P ra-
dhCZl
50-AMP BUS BAR
CIRCUIT BREAKER Y-W TOP
DOWN
RELAY
W-BL
TOP CONTROL SWITCH O UP
TOP RETRACT
When the top is unlocked, the top unlock limit switch is actuated and the
switch contacts are repositioned. The current now flows from the top unlock
limit switch, through the top down limit switch, and the top down relay coil to
ground. This closes the relay multiple contacts and completes the power cir
cuits to the top and deck motor and the top solenoid valves. The two top solen
oid valves are energized and the proper hydraulic lines are opened to the control
cylinders. At the some time, the top and deck motor is energized and the top is
lowered into the luggage compartment.
CIRCUIT BREAKER
RELAY PANEL^.^ «
WIRING COLOR CODE PANEL
DECK CLOSE RELAY
Y - YELLOW
V - VIOLET
R- RED kvr^^C>^.^ DECK LOCK
BL - BLUE V15W^=^ (A RELAY
B-G - BLACK . GREEN nM^PV.
STRIPE
Y-R - YELLOW • RED %iK3mw DECK CONTROL
STRIPE SOLENOID VALVE
V.R - VIOLET - RED
STRIPE / ^
V-W - VIOLET - WHITE /
STRIPE / DECK CLOSED
BL-G - BLUE . GREEN / LIMIT SWITCH
r.BL - yell55'-1lue top coktrol switch
PUSHED DOWN TOP AND DECK MOTOR
STRIPE
BL-R - BLUE - RED TOP DOWN
LIMIT SWITCH
DECK LOCK MOTOR
STRIPE
TO BATTERY
TERMINAL
TO JUNCTION BLOCK
V DOWN p DECK
LOCK
RELAY
DECK CLOSED
LIMIT SWITCH
TOP DOWN
LIMIT SWITCH
O I O
DECK LOCK TOP AND DECK A DECK CONTROL
MOTOR MOTOR V SOLENOID VALVE
When the top is stowed in the luggage compartment, the top down limit switch
Is actuated and the switch contacts are repositioned. The current now flows
from the top control switch, through the top down limit switch, the deck closed
limit switch, and the deck close relay coil to ground. The relay contacts are
closed and the power circuit is complete from the 50-ompere circuit breaker to
the top and deck motor and the deck control solenoid volve.
The deck control solenoid Is energized and hydraulic lines are opened to the
the deck control cylinders. The top and deck motor is also energized and the
deck lid is closed. This action is interrupted when the deck lid depresses the
plunger on the deck closed limit switch.
At the same time the deck lid is closing, the deck lock motor is energized.
This is accomplished by the current flowing from the top down limit switch
through the deck lock relay coil to ground. This closes the relay contacts and
completes the power circuit to the deck lock motor. The deck lock motor Is
energized until the top control switch is released.
TOP ERECT CYCLE
WIRING COLOR CODE CIRCUIT BREAKER
B - BLACK RELAY PANEL PANEL
Y - YELLOW
0 - ORANGE DECK UNLOCK RELAY
R-RED
TOP DOWN
V - VIOLET
LIMIT SWITCH
BL - BLUE
BR - BROWN
TOP LOCK MOTOR
B.G - BLACK • GREEN
STRIPE
R-Y - RED - YELLOW
STRIPE
0-B - ORANGE - BLACK
STRIPE DECK OPEN LIMIT
BL-G - BLUE - GREEN TOP CONTROL SWITCH SWITCH #2
STRIPE PUSHED UP (1964)
R.BL - RED • BLUE
STRIPE
DECK OPEN LIMIT
TO BATTERY b
TERMINAL •
50-AMP BUS BAR DECK OPEN LIMIT
CIRCUIT BREAKER SWITCH
BR
o—
_LeO>_R:BL_ DECK
UNLOCK
B-G DOWN 15-AMP CIRCUIT f RELAY
TOP CONTROL BREAKER
TO ACCESSORY NEUTRAL RELAY DECK LOCK
TERMINAL OF MOTOR
IGNITION SWITCH
0-BR 0-B
NEUTRAL R-BL
SWITCH
STARTING MOTOR
RELAY
With the top control switch in the top up position, current flows from the top
control switch, through the top down limit switch, the deck open limit switch
(#2 for 1964) and the deck unlock relay coil to ground. The relay is energized,
the contacts are closed, and the power circuit is completed to the deck lock
motor. The motor is energized and the luggage compartment is unlocked.
CIRCUIT BREAKER PANEL
DECK UNLOCK RELAY DECK OPEN RELAY
WIRING COLOR CODE RELAY PANEL
R-RED .DECK CLOSED LIMIT SWITCH
Y - YELLOW
V - VIOLET
BR - BROWN DECK LOCK MOTOR
R-Y - RED - YELLOW
STRIPE
DECK CONTROL
0.B - ORANGE • BLACK STRIPE
SOLENOID VALVE
Y-V - YELLOW - VIOLET STRIPE
BL.R - BLUE • RED STRIPE
BL-G - BLUE • GREEN STRIPE
R.BL - RED • BLUE STRIPE TOP AND DECK MOTOR
O-BR - ORANGE • BROWN
TOP CONTROL SWITCH
STRIPE
PUSHED UP
DECK OPEN LIMIT SWITCH f2
(1964)
TOP DOWN
LIMIT SWITCH
DECK OPEN LIMIT
SWITCH -1965
QLJ-P
Y.V
BL.R BL.R
DECK CLOSED
J, LIMIT SWITCH
DECK DECK CONTROL
TO BATTERY
TERMINAL •-
OPEN SOLENOID VALVE
RELAY
SO-AMP BUS BAR
CIRCUIT BREAKER
TOP AND DECK
MOTOR
DECK LOCK
MOTOR
oo 1I oo 5}?
DECK OPEN LIMIT TOP DOWN
SWITCH LIMIT SWITCH
BR
(f •^) 0
As soon OS the deck lid is unlocked, the deck closed limit switch contacts ore
repositioned. Now the current flows from the top down limit switch, through the
deck open limit switch, (#2 for 1964) through the deck closed limit switch,
and the deck open relay coil to ground. The relay multiple contacts close and
the power circuits to the deck control solenoid valve and the top and deck motor
ore completed. The deck control solenoid valve is energized and the hydraulic
lines are opened to the deck hydraulic control cylinders. The top and deck motor
is energized and the deck lid is opened. The deck lock motors continue to run
until the deck is completely open.
WIRING COLOR CODE CIRCUIT BREAKER
RELAY PANEL PANEL
R-RED
G - GREEN
TOP UP
Y - YELLOW RELAY
V - VIOLET
BL- BLUE
W-R - WHITE - RED TOP AND DECK MOTOR
STRIPE
W-BL - WHITE - BLUE
STRIPE
BR-W - BROWN - WHITE
STRIPE
UP
TOP CONTROL SWITCH
o-v
TOP CONTROL
TO JUNCTION BLOCK —CD o
SOLENOID VALVES
DOWN
TOP ERECT
When the deck lid is completely opened, the deck open limit switch plunger is
depressed and the switch contacts are repositioned. The current now flows from
the top control switch, through the top up limit switch rear, the deck open limit
switch, (#2 for 1964) and the top up relay coil to ground. The relay multiple
contacts are closed and the power circuits ore completed to the top and deck
motor and the two top control solenoid valves. The two top control solenoid
valves, when energized, open the hydraulic lines to the top hydraulic control
cylinders; at the same time the top and deck motor is energized and the top is
erected.
WIRING COLOR CODE TOP UP LIMIT SWITCH FRONT
0 - ORANGE
RELAY PANEL
V- VIOLET
Y- YELLOW TOP LOCK MOTOR
BL > BLUE
B-R - BLACK - RED STRIPE
R.B RED - BLACK STRIPE
R-G - RED - GREEN STRIPE
UPPER BACK PANEL
BL.G - BLUE • GREEN STRIPE
LIMIT SWITCH
BL-Y - BLUE - YELLOW STRIPE
TOP
BL BL-G LOCK
B.R RELAY
TO JUNCTION BLOCK
TOP LOCK
MOTOR
R-G
TOP UP LIMIT
p
SWITCH FRONT
UPPER BACK PANEL
o o
LIMIT SWITCH
TOP LOCK
As the top approaches the full up position, and the package tray seats in posi
tion, the top up limit switch rear is depressed, opening the circuit to the top up
relay. This stops the top motor and pump assembly. At the same time the top
comes in contact with the windshield header, the contacts of the top up limit
switch front are closed. The current now flows from the top control switch,
through the top up limit switch front, upper bock panel limit switch, and the top
lock relay coil to ground. The relay contacts close and the power circuit is
completed to the top lock motor. The motor is energized and the top is locked
into position. The lock motor remains energized until the upper back panel is
retracted.
TOP LOCK LIMIT SWITCH
TOP UP LIMIT
SWITCH FRONT (REF.)
TOP LOCK MOTOR (REF.)
UPPER BACK PANEL
LIMIT SWITCH
WIRING COLOR CODE
Y - YELLOW
0 - ORANGE
V - VIOLET
BL - BLUE UPPER BACK
R.W - RED • WHITE STRIPE PANEL MOTOR
W-R - WHITE • RED STRIPE
R-B - RED • BLACK STRIPE
G-W - GREEN • WHITE STRIPE
TOP CONTROL SWITCH
B.R - BLACK • RED STRIPE
PUSHED UP UPPER BACK PANEL
R-G - RED • GREEN STRIPE
RELAY PANEL
RETRACT RELAY
W-BL - WHITE • BLUE STRIPE
BL-0 - BLUE • ORANGE STRIPE CIRCUIT BREAKER
BL-Y - BLUE - YELLOW STRIPE PANEL
BL-G - BLUE • GREEN STRIPE BL TOP LOCK RELAY
15-AMP
TO BATTERY
TERMINAL CIRCUIT BREAKER
BL-G
BL BL-0 W-R UPPER BACK PANEL
± RETRACT RELAY
50-AMP BUS BAR 15-AMP CIRCUIT TOP LOCK RELAY
CIRCUIT BREAKER BL-Y BREAKER
TOP UP LIMIT
UP SWITCH FRONT
TOP CONTROL SWITCH .D—
ov DOWN
TO JUNCTION BLOCK-O
TOP LOCK
UPPER BACK PANEL o
MOTOR
LIMIT SWITCH
TOP LOCK o
LIMIT SWITCH
G-W ^ UPPER BACK
)>—(J—& PANEL MOTOR
During the top locking action, the top lock limit switch is actuated and the
switch contacts are closed. This permits the current to flow from the top con
trol switch, through the top lock limit switch, the upper bock panel limit switch,
and the upper back panel retract relay coil to ground. The relay contacts close,
completing the power circuit to the upper back panel motor, and the upper back
panel is retracted. The top lock motor remains energized until the upper back
panel is fully retracted.
CIRCUIT BREAKER
WIRING COLOR CODE PANEL UPPER BACK PANEL
DECK CLOSE
V - VIOLET LIMIT SWITCH
RELAY PANEL RELAY
Y - YELLOW
BL - BLUE DECK LOCK
V.R - VIOLET - RED RELAY
STRIPE
Y-R - YELLOW - RED DECK CONTROL
STRIPE SOLENOID VALVE
R-BL - RED • BLUE
STRIPE
Y-BL - YELLOW - BLUE
STRIPE
B-G - BLACK • GREEN
STRIPE
BL-G- BLUE - GREEN TOP CONTROL SWITCH
STRIPE PUSHED UP
TOP AND DECK MOTOR
DECK CLOSED LIMIT SWITCH
TOP CONTROL
DECK LOCK MOTOR SOLENOID VALVES
DECK CLOSE
TO BATTERY .RELAY
TERMINAL BL
BL BL BL
BL B-G
UP Y DECK CLOSED
TOP CONTROL SWITCH LIMIT SWITCH 15-AMP
CIRCUIT DECK LOCK RELAY
V-R BREAKER Y-R
CD-V-or
TO JUNCTION BLOCK —CZl •CZl
DOWN
-^TV CD R-BL
Y-BL
BL-G
O UPPER BACK PANEL
TOP AND DECK
„ LIMIT SWITCH
DECK MOTOR LOCK MOTOR
DECK CONTROL
SOLENOID VALVE
As soon OS the upper bock panel Is retracted, the upper back panel limit switch
is actuated and the switch contacts are repositioned. This stops the top lock
motor and the upper back panel motor. The current now flows from the top con
trol switch, through the upper bock panel limit switch, the deck closed limit
switch, and the deck close relay coil to ground. The deck close relay multiple
contacts close and the power circuits ore complete to the deck control solenoid
valve and the top and deck motor. The deck control solenoid valve and the top
and deck motor ore energized, closing the deck lid. Current also flows through
the upper bock panel limit switch, through the deck lock relay coil to ground.
The relay is energized, closing the circuit to the deck lock motor. As the deck
lid reaches the closed position, the deck closed limit switch is depressed and
the deck close circuit is broken. The deck lock circuit will continue to be en
ergized, and the locks will ratchet until the top control switch is released.
Official Licensed Product
MP62
RE . / P R O D U C T IONS,! NC.