1964-65 LINCOLN CONTINENTAL

CONVERTIBLE TOP
REPAIR & ADJUSTMENT
MANUAL
CONVERTIBLE TOP

OPERATION
AND
SCHEMATIC
DIAGRAMS

A PRODUCT OF

MOTOR COMPANY
TABLE OF CONTENTS
PAGE NO.
DESCRIPTION AND OPERATION 4
ELECTRICAL SYSTEM 5
HYDRAULIC SYSTEM 6
Deck Open Cycle 6
Top Up Cycle 6
Deck Close Cycle 8
Top Down Cycle 8
SCHEMATIC DIAGRAMS 10
TOP RETRACT CYCLE
Deck Lid Unlock IQ
Deck Lid Open ||
Upper Bock Panel Erect 12
Top Unlock 13
Top Retract I4
Deck Lid Close and Lock 15
TCP ERECT CYCLE
Deck Lid Unlock 16
Deck Lid Open 17
Top Erect . I8
Top Lock 19
Upper Back Panel Retract 20
Deck Lid Close and Lock 21
TOP UP LIMIT SWITCH - FRONT
TOP LOCK MOTOR

TOP UNLOCK LIMIT SWITCH TOP DOWN


DECK UNLOCK RELAY
LIMIT SWITCH
DECK OPEN RELAY
DECK CLOSED
LIMIT SWITCH
MAIN RELAY
PANEL

DECK CONTROL
SOLENOID

TOP CONTROL SWITCH

RELAY & CIRCUIT BREAKER (PASS. COMPT. SIDE)

TOP HYDRAULIC CYLINDERS CYLINDER


TOP & DECK
TOP UP LIMIT MOTOR
SWITCHI- REAR
DECK OPEN LIMIT
UPPER BACK SWITCH (1964)
PANEL LIMIT DECK OPEN LIMIT
SWITCH
SWITCH (1965)
UPPER BACK DECK HYDRAULIC
PANEL MOTOR CYLINDER
DECK LOCK MOTOR TOP CONTROL
SOLENOIDS

FIGURE 1 - 1965 Lincoln Continental Convertible Top and Deck


Electrical and Hydraulic Components

DESCRIPTION AND OPERATION


The convertible features automatic lowering of the top ossembly Into the lug
gage compartment. The deck lid completely conceals the top when it is in the
retracted position. The operation of the top is accomplished by electrically
powered mechanical and hydraulic linkage.
The top operation is divided into two cycles; the retract cycle in which the
top unlocks and lowers into the luggage compartment, and the erect cycle in
which the top is raised from the stacked position and locks to the windshield
header.
The car should be stopped and all side windows lowered before the top Is
operated. The ignition switch must be in the ACC or ON position, preferably
with the engine running. The transmission selector lever must be in either the
N or P position; then, actuate the top control switch.
To retract (lower the top), push the top control switch down and hold it until
the deck lid has fully opened. Then, make sure that nothing is stored in the
luggage compartment that could interfere with the top as it is lowered. Hold the
top control switch down again until the top retract cycle is completed.
To erect (raise the top), push the top control switch up to open the deck lid
and raise the top assembly into position. After the deck lid closes and locks,
release the top control switch.

The top can be stopped at any time in either cycle (retract or erect) simply by
releasing the top control switch. When the top control switch is released, the
solenoid valves, which are connected to the hydraulic pressure lines, close and
prevent further movement of the top assembly until the circuit is reactivated by
moving the top control switch. Do not attempt to manually force the top or deck
lid either up or down.

ELECTRICAL SYSTEM
The electrical system includes four reversible motors; the top lock motor that
drives two hook locking rods that lock and unlock the top to the windshield
header; the upper back panel motor that drives the upper back panel by a small
transmission; the deck lock motor that locks and unlocks the deck lid through
flexible drive cables; and the top-deck motor that drives a hydraulic pump which
supplies hydraulic fluid pressure to open and close the deck lid and the top
assembly.

There are 11 relays; the top control neutral relay is used as a safety device
in the control circuit. This relay is located on the mounting plate located behind
the right front fender splash shield. The control circuit cannot be energized
until the top control neutral relay contacts are closed. The circuit is complete
only when the neutral switch is closed. The circuit is closed when the trans
mission: selector lever is in P or N and the ignition switch is in the ACC or ON
positiorf. The control circuit to the top control switch is identical for both the
top retract cycle and top erect cycle. Current flows from the ignition switch,
through the top control neutral relay, the transmission neutral switch, and the
starter motor relay to ground. The top control neutral relay is energized, closing
the relay contacts, and current flows from the 10-ampere circuit breaker through
the top control switch.

The remaining 10 relays are used to energize the motors and the three solen
oids.

The electrical system is protected by five circuit breakers; a 50-ampere circuit


breaker in the power circuit, a 10-ampere circuit breaker in the top control cir
cuit and three individual 15-ampere circuit breakers, one for each motor feed
circuit. The 50-ampere circuit breaker and the 10-ampere circuit breaker are
located on the wiring and circuit breaker assembly which is located on the right
cowl side panel behind the kick pad.
HYDRAULIC SYSTEM

The deck lid and convertible top ossembly ore eoch operoted by two hydrouiic
cylinders, receiving pressure from one electricolly powered reversible motor
ond pump. The hydrouiic fluid pressure is controlled by three electricolly octi-
voted solenoid volves, two for the top ossembly, ond one for the deck lid.

DECK LID
HYDRAULIC CYLINDERS

PRESSURE

RETURN

DECK CONTROL
SOLENOID OPEN
FOR DECK OPEN CYCLE

DECK OPEN CYCLE

TOP AND DECK PUMP RESERVOIR

TOP AND DECK PUMP

DECK OPEN
CYCLE

TOP UP
CYCLE
TOP AND DECK MOTOR
NOTE MOTOR ROTATION CLOCKWISE
FOR THESE TWO CYCLES.

FOLDING TOP
HYDRAULIC CYLINDERS

TOP CONTROL
SOLENOIDS OPEN
FOR TOP UP CYCLE TOP UP CYCLE
(ERECT)

FIGURE 2 - Deck Open & Top Up Cycle


DECK OPEN CYCLE:
The deck open relay energizes the top and deck motor and pump assembly and
simultaneously opens the deck solenoid. Hydraulic fluid under pressure supplied
by the clockwise rotation of the pump is applied to the piston in the deck lid
lift cylinders through the hoses connected to the lower fittings of the cylinders.
As the fluid pressure forces the piston to travel upward in the cylinder it dis
places the fluid on the other side of the pistons and returns this fluid through
the hoses connected to the upper fittings of the cylinders bock to the pump and
reservoir.

The cycle can be stopped at any time by release of the control switch opening
the circuit to the deck open relay. The open circuit stops the pump motor and
automatically closes the deck solenoid.

TOP UP CYCLE: (ERECT)


The top up relay energizes the top and deck motor and pump assembly and
simultaneously opens the top solenoids. Hydraulic fluid under pressure supplied
by the clockwise rotation of the pump is directed through the upper top solenoid
and is applied to the piston in the top lift cylinders through the hoses connected
to the upper fittings of the cylinders. As the fluid pressure forces the piston to
travel downward in the cylinder it displaces the fluid on the other side of the
piston and returns this fluid through the hoses connected to the lower fittings
of the cylinders, back through the lower top solenoid to the pump and reservoir.

The cycle can be stopped at any time by release of the control switch opening
the circuit to the top up relay. The open circuit stops the pump motor and auto
matically closes the top solenoids.
HYDRAULIC SYSTEM

PRESSURE

RETURN

rtprv I in

DECK CONTROL
SOLENOID OPEN
FOR DECK CLOSE CYCLE

DECK CLOSE CYCLE

TOP AND DECK PUMP RESERVOIR

TOP AND DECK PUMP


DECK CLOSE
CYCLE
TOP DOWN TOP AND DECK MOTOR
CYCLE

NOTE:
MOTOR ROTATION FOLDING TOP
COUNTERCLOCKWISE FOR HYDRAULIC CYLINDERS
THESE TWO CYCLES.

TOP CONTROL
SOLENOIDS OPEN
FOR TOP DOWN CYCLE TOP DOWN CYCLE
(RETRACT)

FIGURE 3 - Deck Close & Top Down Cycle


DECK CLOSE CYCLE:
The deck close relay energizes the top and deck motor and pump assembly and
simultaneously opens the deck solenoid. Hydraulic fluid under pressure supplied
by counterclockwise rotation of the pump is applied to the piston in the deck
lift cylinders through the hoses connected to the upper fittings of the cylinders.
As the fluid pressure forces the piston to travel downward in the cylinder it dis
places the fluid on the other side of the piston and returns this fluid through the
hoses connected to the lower fittings of the cylinders back through the deck
solenoid to the pump and reservoir.
The cycle con be stopped at any time by release of the control switch opening
the circuit to the deck close relay. The open circuit stops the pump motor and
automotically closes the deck solenoid.

TOP DOWN CYCLE: (RETRACT)


The top down relay energizes the top and deck motor and pump assembly and
simultaneously opens the top solenoids. Hydraulic fluid under pressure supplied
by the counterclockwise rotation of the pump is directed through the lower top
solenoid and is applied to the piston in the top lift cylinders through the hoses
connected to the lower fittings of the cylinders. As the fluid pressure forces the
piston to travel upward in the cylinder it displaces the fluid on the other side of
the piston and returns this fluid through the hoses connected to the upper fittings
of the cylinders, bock through the upper top solenoid to the pump and reservoir.

The cycle con be stopped at any time by release of the control switch opening
the circuit to the top down relay. The open circuit stops the pump motor and auto
matically closes the top solenoids.
TOP RETRACT CYCLE

WIRING COLOR CODE CIRCUIT BREAKER PANEL


B - BLACK RELAY PANEL
R - RED
DECK UNLOCK RELAY
0-ORANGE
V - VIOLET
BL - BLUE UPPER BACK PANEL
BR - BROWN LIMIT SWITCH
B-Y - BLACK - YELLOW |
STRIPE
B-G - BLACK - GREEN STRIPE
R-BL - RED - BLUE STRIPE
R-Y - RED - YELLOW STRIPE
O-B - ORANGE - BLACK STRIPE
0-BR - ORANGE • BROWN STRIPE

TOP CONTROL SWITCH


'DECK LOCK MOTOR
PUSHED DOWN

'DECK OPEN LIMIT


TO BATTERY SWITCH
TERMINAL #1 for 1964
50-AMP
CIRCUIT BREAKER

FOR LUGGAGE COMPARTMENT LAMP

B-Y 10-AMP IIP


TO 1 CIRCUIT BREAKER,.. ^
JUNCTION
BLOCK
•0-a >>-R-
^ DOWN
TOP CONTROL
NEUTRAL RELAY BUS BAR UPPER BACK PANEL
TO ACCESSORY I BRi 1 LIMIT SWITCH
TERMINAL OF DECK LOCK MOTOR
IGNITION SWITCH

NEUTRAL I DECK
SWITCH If UNLOCK
RELAY
15-AMP
CIRCUIT
BREAKER DECK OPEN
STARTING MOTOR LIMIT SWITCH
RELAY

Fig. 4 - Deck Lid Unlock - Top Retract Cycle

DECK LID UNLOCK

With the top control switch in the top down position, current flows from the top
control switch, through the upper back panel limit switch, the deck open limit
switch, (#1 for 1964) and the deck unlock relay coil to ground. The deck un
lock relay coil is energized, closing the relay contacts which complete the
power circuit from the 50-ampere circuit breaker, through the 15-ampere circuit
to the deck lock motor. The motor is energized and the deck lid i s unlocked.
RELAY PAHEL CIRCUIT BREAKER
PANEL DECK CLOSED UPPER BACK PANEL
LIMIT SWITCH LIMIT SWITCH
WIRING COLOR CODE
V - VIOLET
B - BLACK
DECK
R -
RED SOLENOID
0 -
ORANGE
BL -
BLUE
y.V -
YELLOW - VIOLET
STRIPE
O-B - ORANGE • BLACK TOP AND DECK MOTOR
STRIPE
TOP CONTROL SWITCH
R-Y - RED - YELLOW
PUSHED DOWN
STRIPE DECK LOCK
DECK
O.BR - ORANGE • BROWN MOTOR
OPEN
STRIPE RELAY DECK
BL-R - BLUE . RED STRIPE UNLOCK DECK OPEN LIMIT SWITCH
R-BL-RED-BLUE STRIPE RELAY 11 for 1964
BL-G - BLUE -GREEN STRIPE

TO BATTERY
TERMINAL

SO-AMP DECK CLOSED


CIRCUIT BREAKER LIMIT SWITCH
Y.V
DECK
OPEN
TOP CONTROL SWITCH RELAY
TOP AND
OV
DECK MOTOR
TO JUNCTION BLOCK
DOWN

UPPER BACK PANEL


LIMIT SWITCH
BUS BAR
DECK CONTROL
15. AMP SOLENOID VALVE
CIRCUIT BREAKER DECK
UNLOCK
RELAY
DECK LOCK MOTOR

DECK OPEN LIMIT


SWITCH
<f-^
o o

Fig. 5 - Deck Lid Open - Top Retract Cycle

DECK LID OPEN

As soon OS the deck lid is unlocked, the deck closed limit switch contacts
are repositioned. The current now flows from the top control switch through the
upper bock panel limit switch, through the deck open limit switch, (# 1 for 1964)
through the deck closed limit switch and the deck open relay coil to ground.
This closes the deck open relay multiple contacts which complete the power
circuits from the 50-ampere circuit breaker to the top and deck motor and the
deck solenoid valve.

The deck solenoid valve is energized and the proper hydraulic lines are opened
to the deck lift cylinders. At the same time, the top and deck motor is energized
and the deck lid is opened. The deck locks continue to operate until the deck is
completely open.
WIRING COLOR CODE
CIRCUIT BREAKER
RELAY PANEL PANEL
V - VIOLET
UPPER BACK PANEL
R - RED
ERECT RELAY
BL-BLUE UPPER BACK PANEL
OR - GREY LIMIT SWITCH
BL-G-BLUE-GREEN
STRIPE
BL-0 - BLUE - ORANGE
STRIPE
BL-R - BLUE • RED
UPPER BACK
STRIPE
'PANEL MOTOR
BL-W - BLUE - WHITE
STRIPE
B-BL - BLACK • BLUE
STRIPE

TOP CONTROL SWITCH


PUSHED DOWN DECK OPEN LIMIT
•SWITCH
n (or 1964

50*AMP 15-AMP CIRCUIT BL-W


CIRCUIT BREAKER BREAKER / r
UPPER/BACK
TO BATTERY BUS BAR PANEL ERECT
TERMINAL UP RELAY
TOP CONTROL SWITCH °

TO JUNCTION BLOCK —O
DOWN
UPPER BACK 1
PANEL MOTOR'

UPPER BACK PANEL


LIMIT SWITCH

DECK OPEN
LIMIT SWITCH
O I 0

Fig. 6 —Upper Back Panel Erect - Top Retract Cycle

UPPER BACK PANEL ERECT

When the deck lid is completely open, the plunger of the deck open limit switch
is depressed and the switch contacts are repositioned. The current now flows
from the top control switch, through the deck open limit switch (#1 for 1964)
the upper back panel limit switch, and the upper back panel erect relay coil to
ground. The upper back panel relay contacts close and the power circuit is
completed from the 50-ampere circuit breaker through the 15-ampere circuit break
er to the upper back panel motor. The motor is energized and the upper back
panel is erected.
CIRCUIT BREAKER PANEL
RELAY PANEL

TOP LOCK MOTOR TOP UNLOCK RELAY UPPER BACK PANEL


LIMIT SWITCH
TOP UNLOCK
LIMIT SWITCH" WIRING COLOR CODE
R-RED
V - VIOLET
BL - BLUE
B-Y - BLACK • YELLOW
STRIPE
Y-B - YELLOW • BLACK
TOP CONTROL SWITCH STRIPE
PUSHED DOWN BL-Y - BLUE - YELLOW
STRIPE
BL.G - BLUE . GREEN
STRIPE
BR-G - BROWN • GREEN
STRIPE

15.AMP
CIRCUIT BREAKER ^-Y
TO BATTERY
TERMINAL ^
TOP
SO-AMP BUS BAR UNLOCK
CIRCUIT BREAKER RELAY

TOP CONTROL SWITCH TOP LOCK C


MOTOR t
TO JUNCTION BLOCK-
UPPER BACK PANEL
LIMIT SWITCH
o I o
dt BR-G

TOP UNLOCK
LIMIT SWITCH

Fig. 7 - Top Unlock - Top Retract Cycle

TOP UNLOCK

As soon OS riie upper bock pone) is in the erect position, the upper bock panel
limit switch is actuated and the switch contacts are repositioned. The current
now flows from riie top control switch, through the top unlock limit switch, the
upper back panel limit switch and the top unlock relay coll to ground. The relay
contacts close and complete the power circuit from the 5(^ampere circuit breaker
through the 15-ampere circuit breaker to the top lock motor. The motor is ener
gized and the top is unlocked.
WIRING COLOR CODE TOP UNLOCK LIMIT SWITCH
R - RED CIRCUIT BREAKER PANEL
Y - YELLOW RELAY PANEL,
W - WHITE
V - VIOLET
BL - BLUE
W.BL - WHITE - BLUE
TOP DOWN
STRIPE RELAY
Y-W - YELLOW - WHITE
STRIPE
V-W - VIOLET - WHITE
STRIPE

TOP CONTROL SWITCH TOP AND DECK MOTOR


PUSHED DOWN

TOP SOLENOIDS

TOP DOWN LIMIT SWITCH

TO BATTERY
TER^NAL BL BL
P P ra-
dhCZl
50-AMP BUS BAR
CIRCUIT BREAKER Y-W TOP
DOWN
RELAY

W-BL
TOP CONTROL SWITCH O UP

TO JUNCTION BLOCK DOWN


R

TOP SOLENOID (2) TOP AND DECK


TOP UNLOCK MOTOR
LIMIT SWITCH
O I O
V-W
-O rv
TOP DOWN
LIMIT SWITCH
O O

Fig. 8 —Top Retract —Top Retract Cycle

TOP RETRACT

When the top is unlocked, the top unlock limit switch is actuated and the
switch contacts are repositioned. The current now flows from the top unlock
limit switch, through the top down limit switch, and the top down relay coil to
ground. This closes the relay multiple contacts and completes the power cir
cuits to the top and deck motor and the top solenoid valves. The two top solen
oid valves are energized and the proper hydraulic lines are opened to the control
cylinders. At the some time, the top and deck motor is energized and the top is
lowered into the luggage compartment.
CIRCUIT BREAKER
RELAY PANEL^.^ «
WIRING COLOR CODE PANEL
DECK CLOSE RELAY
Y - YELLOW
V - VIOLET
R- RED kvr^^C>^.^ DECK LOCK
BL - BLUE V15W^=^ (A RELAY
B-G - BLACK . GREEN nM^PV.
STRIPE
Y-R - YELLOW • RED %iK3mw DECK CONTROL
STRIPE SOLENOID VALVE
V.R - VIOLET - RED
STRIPE / ^
V-W - VIOLET - WHITE /
STRIPE / DECK CLOSED
BL-G - BLUE . GREEN / LIMIT SWITCH
r.BL - yell55'-1lue top coktrol switch
PUSHED DOWN TOP AND DECK MOTOR
STRIPE
BL-R - BLUE - RED TOP DOWN
LIMIT SWITCH
DECK LOCK MOTOR
STRIPE

TO BATTERY
TERMINAL

50-AMP BUS BAR


DECK
CIRCUIT BREAKER
CLOSE
RELAY
15-AMP
CIRCUIT
BREAKER
TOP CONTROL SWITCH

TO JUNCTION BLOCK
V DOWN p DECK
LOCK
RELAY

DECK CLOSED
LIMIT SWITCH
TOP DOWN
LIMIT SWITCH
O I O
DECK LOCK TOP AND DECK A DECK CONTROL
MOTOR MOTOR V SOLENOID VALVE

Fig. 9 - Deck Lid Close and Lock - Top Retract Cycle

DECK LID CLOSE AND LOCK

When the top is stowed in the luggage compartment, the top down limit switch
Is actuated and the switch contacts are repositioned. The current now flows
from the top control switch, through the top down limit switch, the deck closed
limit switch, and the deck close relay coil to ground. The relay contacts are
closed and the power circuit is complete from the 50-ompere circuit breaker to
the top and deck motor and the deck control solenoid volve.

The deck control solenoid Is energized and hydraulic lines are opened to the
the deck control cylinders. The top and deck motor is also energized and the
deck lid is closed. This action is interrupted when the deck lid depresses the
plunger on the deck closed limit switch.

At the same time the deck lid is closing, the deck lock motor is energized.
This is accomplished by the current flowing from the top down limit switch
through the deck lock relay coil to ground. This closes the relay contacts and
completes the power circuit to the deck lock motor. The deck lock motor Is
energized until the top control switch is released.
TOP ERECT CYCLE
WIRING COLOR CODE CIRCUIT BREAKER
B - BLACK RELAY PANEL PANEL
Y - YELLOW
0 - ORANGE DECK UNLOCK RELAY
R-RED
TOP DOWN
V - VIOLET
LIMIT SWITCH
BL - BLUE
BR - BROWN
TOP LOCK MOTOR
B.G - BLACK • GREEN
STRIPE
R-Y - RED - YELLOW
STRIPE
0-B - ORANGE - BLACK
STRIPE DECK OPEN LIMIT
BL-G - BLUE - GREEN TOP CONTROL SWITCH SWITCH #2
STRIPE PUSHED UP (1964)
R.BL - RED • BLUE
STRIPE
DECK OPEN LIMIT

TO BATTERY b
TERMINAL •
50-AMP BUS BAR DECK OPEN LIMIT
CIRCUIT BREAKER SWITCH
BR

BL.G TOP DOWN


FOR LUGGAGE COMPARTMENT LAMP
LIMIT SWITCH
BL 10-AMP
TO UP
CIRCUIT BREAKER
JUNCTION by
BLOCK i BL-G

o—
_LeO>_R:BL_ DECK
UNLOCK
B-G DOWN 15-AMP CIRCUIT f RELAY
TOP CONTROL BREAKER
TO ACCESSORY NEUTRAL RELAY DECK LOCK
TERMINAL OF MOTOR
IGNITION SWITCH
0-BR 0-B

NEUTRAL R-BL
SWITCH

STARTING MOTOR
RELAY

Fig. 10 —Deck Lid Unlock —Top Erect Cycle

DECK LID UNLOCK

With the top control switch in the top up position, current flows from the top
control switch, through the top down limit switch, the deck open limit switch
(#2 for 1964) and the deck unlock relay coil to ground. The relay is energized,
the contacts are closed, and the power circuit is completed to the deck lock
motor. The motor is energized and the luggage compartment is unlocked.
CIRCUIT BREAKER PANEL
DECK UNLOCK RELAY DECK OPEN RELAY
WIRING COLOR CODE RELAY PANEL
R-RED .DECK CLOSED LIMIT SWITCH
Y - YELLOW
V - VIOLET
BR - BROWN DECK LOCK MOTOR
R-Y - RED - YELLOW
STRIPE
DECK CONTROL
0.B - ORANGE • BLACK STRIPE
SOLENOID VALVE
Y-V - YELLOW - VIOLET STRIPE
BL.R - BLUE • RED STRIPE
BL-G - BLUE • GREEN STRIPE
R.BL - RED • BLUE STRIPE TOP AND DECK MOTOR
O-BR - ORANGE • BROWN
TOP CONTROL SWITCH
STRIPE
PUSHED UP
DECK OPEN LIMIT SWITCH f2
(1964)
TOP DOWN
LIMIT SWITCH
DECK OPEN LIMIT
SWITCH -1965

QLJ-P
Y.V
BL.R BL.R

DECK CLOSED
J, LIMIT SWITCH
DECK DECK CONTROL
TO BATTERY
TERMINAL •-
OPEN SOLENOID VALVE
RELAY
SO-AMP BUS BAR
CIRCUIT BREAKER
TOP AND DECK
MOTOR

TOP CONTROL SWITCH


R.Y
15.AMP
TO JUNCTION BLOCK CIRCUIT
BREAKER
DECK
UNLOCK
RELAY

DECK LOCK
MOTOR

oo 1I oo 5}?
DECK OPEN LIMIT TOP DOWN
SWITCH LIMIT SWITCH
BR
(f •^) 0

Fig. 11 - Deck Lid Open - Top Erect Cycle

DECK LID OPEN

As soon OS the deck lid is unlocked, the deck closed limit switch contacts ore
repositioned. Now the current flows from the top down limit switch, through the
deck open limit switch, (#2 for 1964) through the deck closed limit switch,
and the deck open relay coil to ground. The relay multiple contacts close and
the power circuits to the deck control solenoid valve and the top and deck motor
ore completed. The deck control solenoid valve is energized and the hydraulic
lines are opened to the deck hydraulic control cylinders. The top and deck motor
is energized and the deck lid is opened. The deck lock motors continue to run
until the deck is completely open.
WIRING COLOR CODE CIRCUIT BREAKER
RELAY PANEL PANEL
R-RED
G - GREEN
TOP UP
Y - YELLOW RELAY
V - VIOLET
BL- BLUE
W-R - WHITE - RED TOP AND DECK MOTOR
STRIPE
W-BL - WHITE - BLUE
STRIPE
BR-W - BROWN - WHITE
STRIPE

DECK OPEN LIMIT


SWITCH «2
TOP CONTROL SWITCH
(1964)
PUSHED UP

TOP CONTROL SOLENOID VALVES

TOP UP LIMIT SWITCH REAR


DECK OPEN
LIMIT SWITCH
(1965)
RELAY
TO BATTERY
TERMINAL
—o ^ n n
BL
50-AMP BUS BAR
CIRCUIT BREAKER

UP
TOP CONTROL SWITCH
o-v
TOP CONTROL
TO JUNCTION BLOCK —CD o
SOLENOID VALVES
DOWN

TOP AND DECK


TOP UP LIMIT t DECK OPEN LIMIT MOTOR
SWITCH REAR SWITCH
L-qJ_£) (f «
BR-W

Fig. 12 —Top Erect - Top Erect Cycle

TOP ERECT

When the deck lid is completely opened, the deck open limit switch plunger is
depressed and the switch contacts are repositioned. The current now flows from
the top control switch, through the top up limit switch rear, the deck open limit
switch, (#2 for 1964) and the top up relay coil to ground. The relay multiple
contacts are closed and the power circuits ore completed to the top and deck
motor and the two top control solenoid valves. The two top control solenoid
valves, when energized, open the hydraulic lines to the top hydraulic control
cylinders; at the same time the top and deck motor is energized and the top is
erected.
WIRING COLOR CODE TOP UP LIMIT SWITCH FRONT
0 - ORANGE
RELAY PANEL
V- VIOLET
Y- YELLOW TOP LOCK MOTOR
BL > BLUE
B-R - BLACK - RED STRIPE
R.B RED - BLACK STRIPE
R-G - RED - GREEN STRIPE
UPPER BACK PANEL
BL.G - BLUE • GREEN STRIPE
LIMIT SWITCH
BL-Y - BLUE - YELLOW STRIPE

TOP CONTROL SWITCH


PUSHED UP
CIRCUIT BREAKER
PANEL TOP LOCK RELAY
TOP UP LIMIT
SWITCH REAR (REF.)

TOP
BL BL-G LOCK
B.R RELAY

TO BATTERY BL-Y R-B


Sk IQ] O- cn
TERMINAL
50-AMP BUS BAR IS-AMP CIRCUIT
CIRCUIT BREAKER BREAKER

TOP CONTROL SWITCH

TO JUNCTION BLOCK
TOP LOCK
MOTOR

R-G

TOP UP LIMIT
p
SWITCH FRONT
UPPER BACK PANEL
o o
LIMIT SWITCH

Fig. 13 - Top Lock —Top Erect Cycle

TOP LOCK

As the top approaches the full up position, and the package tray seats in posi
tion, the top up limit switch rear is depressed, opening the circuit to the top up
relay. This stops the top motor and pump assembly. At the same time the top
comes in contact with the windshield header, the contacts of the top up limit
switch front are closed. The current now flows from the top control switch,
through the top up limit switch front, upper bock panel limit switch, and the top
lock relay coil to ground. The relay contacts close and the power circuit is
completed to the top lock motor. The motor is energized and the top is locked
into position. The lock motor remains energized until the upper back panel is
retracted.
TOP LOCK LIMIT SWITCH

TOP UP LIMIT
SWITCH FRONT (REF.)
TOP LOCK MOTOR (REF.)
UPPER BACK PANEL
LIMIT SWITCH
WIRING COLOR CODE
Y - YELLOW
0 - ORANGE
V - VIOLET
BL - BLUE UPPER BACK
R.W - RED • WHITE STRIPE PANEL MOTOR
W-R - WHITE • RED STRIPE
R-B - RED • BLACK STRIPE
G-W - GREEN • WHITE STRIPE
TOP CONTROL SWITCH
B.R - BLACK • RED STRIPE
PUSHED UP UPPER BACK PANEL
R-G - RED • GREEN STRIPE
RELAY PANEL
RETRACT RELAY
W-BL - WHITE • BLUE STRIPE
BL-0 - BLUE • ORANGE STRIPE CIRCUIT BREAKER
BL-Y - BLUE - YELLOW STRIPE PANEL
BL-G - BLUE • GREEN STRIPE BL TOP LOCK RELAY

15-AMP
TO BATTERY
TERMINAL CIRCUIT BREAKER
BL-G
BL BL-0 W-R UPPER BACK PANEL
± RETRACT RELAY
50-AMP BUS BAR 15-AMP CIRCUIT TOP LOCK RELAY
CIRCUIT BREAKER BL-Y BREAKER

TOP UP LIMIT
UP SWITCH FRONT
TOP CONTROL SWITCH .D—

ov DOWN
TO JUNCTION BLOCK-O

TOP LOCK
UPPER BACK PANEL o
MOTOR
LIMIT SWITCH
TOP LOCK o
LIMIT SWITCH
G-W ^ UPPER BACK
)>—(J—& PANEL MOTOR

Fig. 14 - Upper Back Panel Retract —Top Erect Cycle

UPPER BACK PANEL RETRACT

During the top locking action, the top lock limit switch is actuated and the
switch contacts are closed. This permits the current to flow from the top con
trol switch, through the top lock limit switch, the upper bock panel limit switch,
and the upper back panel retract relay coil to ground. The relay contacts close,
completing the power circuit to the upper back panel motor, and the upper back
panel is retracted. The top lock motor remains energized until the upper back
panel is fully retracted.
CIRCUIT BREAKER
WIRING COLOR CODE PANEL UPPER BACK PANEL
DECK CLOSE
V - VIOLET LIMIT SWITCH
RELAY PANEL RELAY
Y - YELLOW
BL - BLUE DECK LOCK
V.R - VIOLET - RED RELAY
STRIPE
Y-R - YELLOW - RED DECK CONTROL
STRIPE SOLENOID VALVE
R-BL - RED • BLUE
STRIPE
Y-BL - YELLOW - BLUE
STRIPE
B-G - BLACK • GREEN
STRIPE
BL-G- BLUE - GREEN TOP CONTROL SWITCH
STRIPE PUSHED UP
TOP AND DECK MOTOR
DECK CLOSED LIMIT SWITCH

TOP CONTROL
DECK LOCK MOTOR SOLENOID VALVES

DECK CLOSE
TO BATTERY .RELAY
TERMINAL BL
BL BL BL

50-AMP BUS BAR


CIRCUIT BREAKER

BL B-G

UP Y DECK CLOSED
TOP CONTROL SWITCH LIMIT SWITCH 15-AMP
CIRCUIT DECK LOCK RELAY
V-R BREAKER Y-R
CD-V-or
TO JUNCTION BLOCK —CZl •CZl

DOWN
-^TV CD R-BL

Y-BL
BL-G
O UPPER BACK PANEL
TOP AND DECK
„ LIMIT SWITCH
DECK MOTOR LOCK MOTOR

DECK CONTROL
SOLENOID VALVE

Fig. 15 - Deck Lid Close and Lock - Top Erect Cycle

DECK LID CLOSE AND LOCK

As soon OS the upper bock panel Is retracted, the upper back panel limit switch
is actuated and the switch contacts are repositioned. This stops the top lock
motor and the upper back panel motor. The current now flows from the top con
trol switch, through the upper bock panel limit switch, the deck closed limit
switch, and the deck close relay coil to ground. The deck close relay multiple
contacts close and the power circuits ore complete to the deck control solenoid
valve and the top and deck motor. The deck control solenoid valve and the top
and deck motor ore energized, closing the deck lid. Current also flows through
the upper bock panel limit switch, through the deck lock relay coil to ground.
The relay is energized, closing the circuit to the deck lock motor. As the deck
lid reaches the closed position, the deck closed limit switch is depressed and
the deck close circuit is broken. The deck lock circuit will continue to be en
ergized, and the locks will ratchet until the top control switch is released.