Você está na página 1de 2

Data Sheet

BRW-DS-T-0747

900MHz Tower Mounted Amplifier DTA-09-DF-01

Main features

Compact, low weight


High linearity and low noise performance
Lightning protection
Improve base station sensitivity
High reliability
Simple installation

Electrical data
RX TX
Frequency 880~915MHz 925~960MHz
Gain 12±1dB;12±1.2dB@-40°C to +65°C -
Noise Figure 1.4dB Typical;1.8 dB @-40°C to +65°C -
Insertion loss 2.5dB @Bypass mode 0.55dB Typical, 0.6dB
2.7 dB@-40°C to +65°C 0.8 dB@-40°C to +65°C
Return loss -18dB Active / -15dB Bypass -18dB Active / Bypass
OIP3 ≥25dBm Typical -
Power handing - 200W CW MAX,1600W Peak
Intermodulation (3rd order) - -107dBm@BTS
Impedance 50  50 

System data

Operating voltage range DC 10~30V


Operating current @12V <180mA@12V
AISG compatibility AISG2.0

Environmental data

Operating temperature range -40°C to +65°C


Relative humidity 5%- 99%
Environmental standard IP67
Lightning protection 3kA 10/350us, 8kA 8/20 us, 20kA (Shield)
Operational ETS 300 019-1-4
Transportation ETS 300 019-1-2
Storage ETS 300 019-1-11
MTBF ≥1,000,000 hours
QP-TQ4TE-067/ 7.0

Rosenberger Hochfrequenztechnik GmbH & Co. KG Rosenberger (Shanghai) Technology Co., Ltd. Page
Tel.: +49 8684 18-0 Fax: +49 8684 18-499 Tel.: +86 21 69214567 Fax: +86 21 69212923
www.rosenberger.de email : info@rosenberger.de www.rosenbergerap.com email: info@rosenbergerap.com 1/2
Data Sheet
BRW-DS-T-0747

900MHz Tower Mounted Amplifier DTA-09-DF-01

Mechanical data
Connectors type 7-16 female
Housing Aluminum
Mounting Wall fixed and optional pole mounting bracket
Packing 1Pce in box

System Diagram and outline drawing

While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
QP-TQ4TE067/ 7.0

Draft Date Checker Approved Date Rev. Engineering Change Number Name Date
MC.G 26/Jun/18 CY.X Joson 26/Jun/18 1.0 CN2018-0963 MC.G 26/Jul/18

Rosenberger Hochfrequenztechnik GmbH & Co. KG Rosenberger (Shanghai) Technology Co., Ltd. Page
Tel.: +49 8684 18-0 Fax: +49 8684 18-499 Tel.: +86 21 69214567 Fax: +86 21 69212923
www.rosenberger.de email : info@rosenberger.de www.rosenbergerap.com email: info@rosenbergerap.com 2/2