Você está na página 1de 32

Contractors Design Services Ltd.

2nd Floor Millers House,


Roydon Road, Stanstead Abbotts,
Ware, Herts. SG12 8HN
Tel. 01920 877077 Fax 01920 870011
Email enquiries@contractorsdesign.co.uk

Design Calculations
Client: F3 Architects
Project: 23 Denewood Road
Title: Façade Retention and Temporary Propping for Basement
Cal Ref: 17-142-01
Prepared: R Jose BSc(Hons) ACGI CEng MIStructE
Checked:

Revision Date Remarks


0 26.05.17 First Issue
A 23.10.17 Issued for discharge of planning conditions

Reference Documents:

• Structural Engineer’s Construction Method Statement Rev. 02 30th Nov 2016


• 23 Denewood Basement Design Philosophy Statement May 19, 2017
• Party Wall – Capping Beam and Propping Structural Calculations May 2017
• Report on a Ground Investigation at 23 Denewood Road Jan 2017
• Form Drg. Nos. A(PW)01 Rev P1, A(PW)02 Rev P1, L(PW)01 Rev P1, L(PW)02 Rev P1, L(PW)03 Rev P1
• BS 5628-1-2005 Code of Practice for Use of Masonry
• BS EN 1993-1-1 2005 Design of Steel Structures
• Concrete Society - CS030 Formwork A Guide to Good Practice 3rd Edition
• BS 5975-2008+A1-2011 Code of Practice for Temporary Works Procedures and The Permissible Stress
Design of Falsework
• BS 5950-1-2000 Corr.2 Structural Use of Steelwork in Building
• Ciria C579 Retention of Masonry Facades Best Practice Guide
• Hilti Profis

Design Brief:

To design for submission to planning authority a façade retention scheme to a 2-storey high wall front of property.

Key Assumptions:

(a) Allowable bearing pressure = 120kPa


(b) Masonry wall in good condition.
(c) Client’s CAD topographical drawings are to scale.
(d) All existing openings in masonry to have timber box frames fully braced during duration of the retention.
(e) Underpinning prior to façade retention.
(f) Accidental impact to structural members not considered. Hence, protective measures should be provided
to prevent accidental impact.

Summary:

Use 152UC23 rakers and post with twin 150x75 PFC’s back to back walers in front of façade. 15ø ties with waler
nuts to tie walers to façade with 150x75 PFC flat back on wall. Stability to be provided by C20/25 concrete
kentledge of 1.5m deep buried 0.5m to ground.
Significant Residual Risks:

All proprietary equipment to be used in accordance with manufacturer’s recommendations and to be installed by
competent persons.

Façade retention structure to be protected from vandals and accidental loading.


Calculation Sheet
Client: F3 Architects Sheet of Rev

Project: 23 Denewood Road Date: 26/05/2017

Contractors Design Services Ltd. Title: Façade Retention Compiled by: RJ


2nd Floor, Millers House,
Roydon Road, Checked by:
Stanstead Abbotts,
Herts. SG12 8HN Job Ref: 17-142-01 Drg Ref:
Tel. 01920 877077
Web: www.contractorsdesign.co.uk Email: enquiries@contractorsdesign.co.uk

Reference Calculations Output

INDEX
Page

Brief 01
Loadings 01
Masonry Wall Assessment 04
Design of Walers 05
Design of Tie Rods/Packers 05
Design of Rakers 10
Design of Kentledge 14
Design of Baseplate Connections 16
Design of Raker/Post Connection 23
Design of Post 28
Check Foundation 29
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 6
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077

STEEL BEAM ANALYSIS & DESIGN (EN1993-1-1:2005)


In accordance with EN1993-1-1:2005 incorporating Corrigenda February 2006 and April 2009 and the UK national
annex
TEDDS calculation version 3.0.13

Load Envelope - Com bination 1


9.450

0.0
mm 700 3800 700
A 1 B 2 C 3 D

Bending Mom ent Envelope


kNm
-2.3 -2.3
0.0

14.742
14.7
mm 700 3800 700
A 1 B 2 C 3 D

Shear Force Envelope


kN
18.0
17.955
6.6

0.0

-6.6
-17.955
-18.0
mm 700 3800 700
A 1 B 2 C 3 D

Support conditions
Support A Vertically free
Rotationally free
Support B Vertically restrained
Rotationally free
Support C Vertically restrained
Rotationally free
Support D Vertically free
Rotationally free

Applied loading
Beam loads Notional - Permanent full UDL 0.7 kN/m
Wind - Variable full UDL 5.67 kN/m
Load combinations
Load combination 1 Support A Permanent 1.35
Variable 1.50
Span 1 Permanent 1.35
Variable 1.50
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 7
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077

Support B Permanent 1.35


Variable 1.50
Span 2 Permanent 1.35
Variable 1.50
Support C Permanent 1.35
Variable 1.50
Span 3 Permanent 1.35
Variable 1.50
Support D Permanent 1.35
Variable 1.50

Analysis results
Maximum moment; Mmax = 14.7 kNm; Mmin = -2.3 kNm
Maximum moment span 1; Ms1_max = 0 kNm; Ms1_min = -2.3 kNm
Maximum moment span 2; Ms2_max = 14.7 kNm; Ms2_min = -2.3 kNm
Maximum moment span 3; Ms3_max = 0 kNm; Ms3_min = -2.3 kNm
Maximum shear; Vmax = 18 kN; Vmin = -18 kN
Maximum shear span 1; Vs1_max = 0 kN; Vs1_min = -6.6 kN
Maximum shear span 2; Vs2_max = 18 kN; Vs2_min = -18 kN
Maximum shear span 3; Vs3_max = 6.6 kN; Vs3_min = 0 kN
Deflection; max = 7.1 mm; min = 3.9 mm
Deflection span 1; s1_max = 0 mm; s1_min = 3.9 mm
Deflection span 2; s2_max = 7.1 mm; s2_min = 0 mm
Deflection span 3; s3_max = 0 mm; s3_min = 3.9 mm
Maximum reaction at support A; RA_max = 0 kN; RA_min = 0 kN
Maximum reaction at support B; RB_max = 24.6 kN; RB_min = 24.6 kN
Unfactored permanent load reaction at support B; RB_Permanent = 1.8 kN
Unfactored variable load reaction at support B; RB_Variable = 14.7 kN
Maximum reaction at support C; RC_max = 24.6 kN; RC_min = 24.6 kN
Unfactored permanent load reaction at support C; RC_Permanent = 1.8 kN
Unfactored variable load reaction at support C; RC_Variable = 14.7 kN
Maximum reaction at support D; RD_max = 0 kN; RD_min = 0 kN
Section details
Section type; PFC 150x75x18 (BS4-1)
Steel grade; S275
EN 10025-2:2004 - Hot rolled products of structural steels
Nominal thickness of element; t = max(tf, tw) = 10.0 mm
Nominal yield strength; fy = 275 N/mm2
Nominal ultimate tensile strength; fu = 410 N/mm2
Modulus of elasticity; E = 210000 N/mm2
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 8
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077

10
150
5.5

10

75

Partial factors - Section 6.1


Resistance of cross-sections; M0 = 1.00
Resistance of members to instability; M1 = 1.00
Resistance of tensile members to fracture; M2 = 1.10

Lateral restraint
Span 1 has full lateral restraint
Span 2 has full lateral restraint
Span 3 has full lateral restraint
Cantilever tip is free
Cantilever support is continuous with lateral and torsional restraint
Effective length factors
Effective length factor in major axis; Ky = 1.000
Effective length factor in minor axis; Kz = 1.000
Effective length factor for torsion; KLT.A = 1.000;
KLT.B = 1.000;
KLT.C = 1.000;
KLT.D = 1.000;
Classification of cross sections - Section 5.5
= [235 N/mm2 / fy] = 0.92

Internal compression parts subject to bending - Table 5.2 (sheet 1 of 3)


Width of section; c = d = 106 mm
c / tw = 20.8 <= 72 ; Class 1

Outstand flanges - Table 5.2 (sheet 2 of 3)


Width of section; c = b - tw - r1 = 57.5 mm
c / tf = 6.2 <= 9 ; Class 1
Section is class 1
Check shear - Section 6.2.6
Height of web; hw = h - 2 tf = 130 mm
Shear area factor; = 1.000
hw / tw < 72 /
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 9
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077

Shear buckling resistance can be ignored


Design shear force; VEd = max(abs(Vmax), abs(Vmin)) = 18 kN
Shear area - cl 6.2.6(3); Av = A - 2 b tf + (tw + r1) tf = 952 mm2
Design shear resistance - cl 6.2.6(2); Vc,Rd = Vpl,Rd = Av (fy / [3]) / M0 = 151.1 kN
PASS - Design shear resistance exceeds design shear force
Check bending moment at span 2 major (y-y) axis - Section 6.2.5
Design bending moment; MEd = max(abs(Ms2_max), abs(Ms2_min)) = 14.7 kNm
Design bending resistance moment - eq 6.13; Mc,Rd = Mpl,Rd = W pl.y fy / M0 = 36.3 kNm
PASS - Design bending resistance moment exceeds design bending moment
Check vertical deflection - Section 7.2.1
Consider deflection due to variable loads
Limiting deflection;; lim = Ls2 / 360 = 10.6 mm
Maximum deflection span 2; = max(abs( max), abs( min)) = 7.128 mm
PASS - Maximum deflection does not exceed deflection limit
Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 11
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 24/05/2017

STEEL MEMBER DESIGN (EN1993) - RAKERS

STEEL MEMBER DESIGN (EN1993-1-1:2005)


In accordance with EN1993-1-1:2005 incorporating Corrigenda February 2006 and April 2009 and the UK national
annex
Tedds calculation version 4.2.00

Partial factors - Section 6.1


Resistance of cross-sections M0 =1
Resistance of members to instability M1 =1
Resistance of tensile members to fracture M2 = 1.1

Design section 1
Section details
Section type UC 152x152x23 (BS4-1)
Steel grade - EN 10025-2:2004 S275
Nominal thickness of element tnom = max(tf, tw) = 6.8 mm
Nominal yield strength fy = 275 N/mm2
Nominal ultimate tensile strength fu = 410 N/mm2
Modulus of elasticity E = 210000 N/mm2

UC 152x152x23 (BS4-1)
Section depth, h, 152.4 mm
Section breadth, b, 152.2 mm
Mass of section, Mass, 23 kg/m
Flange thickness, tf, 6.8 mm
Web thickness, tw, 5.8 mm
Root radius, r, 7.6 mm
Area of section, A, 2925 mm2
Radius of gyration about y-axis, iy, 65.372 mm
Radius of gyration about z-axis, iz, 36.979 mm
Elastic section modulus about y-axis, W el.y, 164016 mm3
Elastic section modulus about z-axis, W el.z, 52552 mm3
5.8 Plastic section modulus about y-axis, W pl.y, 181982 mm3
Plastic section modulus about z-axis, W pl.z, 80156 mm3
Second moment of area about y-axis, Iy, 12498039 mm4
Second moment of area about z-axis, Iz, 3999186 mm4

152.2

Analysis results
Design axial compression force NEd = 92 kN
Restraint spacing
Major axis lateral restraint Ly = 4300 mm
Minor axis lateral restraint Lz = 4300 mm
Torsional restraint LT = 4300 mm
Classification of cross sections - Section 5.5
= [235 N/mm2 / fy] = 0.92

Internal compression parts subject to compression - Table 5.2 (sheet 1 of 3)


Width of section c = d = 123.6 mm
c / tw = 21.3 = 23.1 <= 33 Class 1
Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 12
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 24/05/2017

Outstand flanges - Table 5.2 (sheet 2 of 3)


Width of section c = (b - tw - 2 r) / 2 = 65.6 mm
c / tf = 9.6 = 10.4 <= 14 Class 3
Section is class 3
Check compression - Section 6.2.4
Design compression force NEd = 92 kN
Design resistance of section - eq 6.10 Nc,Rd = Npl,Rd = A fy / M0 = 804.2 kN
NEd / Nc,Rd = 0.114
PASS - Design compression resistance exceeds design compression
Slenderness ratio for y-y axis flexural buckling - Section 6.3.1.3
Critical buckling length Lcr,y = Ly_s1 = 4300 mm
Critical buckling force Ncr,y = 2 E Iy / Lcr,y2 = 1401 kN
Slenderness ratio for buckling - eq 6.50 y = (A fy / Ncr,y) = 0.758

Check y-y axis flexural buckling resistance - Section 6.3.1.1


Buckling curve - Table 6.2 b
Imperfection factor - Table 6.1 y = 0.34
2
Buckling reduction determination factor y = 0.5 (1 + y ( y - 0.2) + y ) = 0.882
2 2
Buckling reduction factor - eq 6.49 y = min(1 / ( y + ( y - y )), 1) = 0.75
Design buckling resistance - eq 6.47 Nb,y,Rd = y A fy / M1 = 603.3 kN
NEd / Nb,y,Rd = 0.152
PASS - Design buckling resistance exceeds design compression
Slenderness ratio for z-z axis flexural buckling - Section 6.3.1.3
Critical buckling length Lcr,z = Lz_s1 = 4300 mm
Critical buckling force Ncr,z = 2 E Iz / Lcr,z2 = 448.3 kN
Slenderness ratio for buckling - eq 6.50 z = (A fy / Ncr,z) = 1.339

Check z-z axis flexural buckling resistance - Section 6.3.1.1


Buckling curve - Table 6.2 c
Imperfection factor - Table 6.1 z = 0.49
2
Buckling reduction determination factor z = 0.5 (1 + z ( z - 0.2) + z ) = 1.676
Buckling reduction factor - eq 6.49 = min(1 / ( + ( 2 - 2
z z z z )), 1) = 0.373
Design buckling resistance - eq 6.47 Nb,z,Rd = z A fy / M1 = 299.7 kN
NEd / Nb,z,Rd = 0.307
PASS - Design buckling resistance exceeds design compression
Check torsional and torsional-flexural buckling - Section 6.3.1.4
Torsional buckling length Lcr,T = LT_s1 = 4300 mm
Distance from shear centre to centroid in y axis y0 = 0.0 mm
Distance from shear centre to centroid in z axis z0 = 0.0 mm
Radius of gyration i0 = (iy2 + iz2) = 75.1 mm
Elastic critical torsional buckling force Ncr,T = 1 / i02 (G It + 2
E Iw / Lcr,T2) = 1084.8 kN
2
Torsion factor T = 1 - (y0 / i0) = 1
Elastic critical torsional-flexural buckling force
Ncr,TF = Ncr,y / (2 T) [1 + Ncr,T / Ncr,y - [(1 - Ncr,T / Ncr,y)2 + 4 (y0 / i0)2 Ncr,T / Ncr,y]] = 1084.8 kN
Elastic critical buckling force Ncr = min(Ncr,T, Ncr,TF) = 1084.8 kN
Slenderness ratio for torsional buckling - eq 6.52 T = [A fy / Ncr] = 0.861
Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 13
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 24/05/2017

Design resistance for torsional and torsional-flexural buckling - Section 6.3.1.1


Buckling curve - Table 6.2 c
Imperfection factor - Table 6.1 T = 0.49
Buckling reduction determination factor = 0.5 (1 + ( - 0.2) + 2) = 1.033
T T T T
2 2
Buckling reduction factor - eq 6.49 T = min(1 / ( T + ( T - T )), 1) = 0.624
Design buckling resistance - eq 6.47 Nb,T,Rd = T A fy / M1 = 501.8 kN
NEd / Nb,T,Rd = 0.183
PASS - Design buckling resistance exceeds design compression
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 17
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:

Specifier's comments:

1 Input data
Anchor type and size: HIT-HY 200-A + HIT-Z M16
Effective embedment depth: hef,opti = 108 mm (hef,limit = 192 mm)
Material: DIN EN ISO 4042
Approval No.: ETA 12/0006
Issued I Valid: 18/08/2016 | -
Proof: Design method ETAG BOND (EOTA TR 029)
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Baseplate: lx x ly x t = 350 mm x 350 mm x 12 mm; (Recommended plate thickness: not calculated
Profile: Advance UKC; (L x W x T x FT) = 152 mm x 152 mm x 7 mm x 7 mm
Base material: cracked concrete, C20/25, fc,cube = 25.00 N/mm2; h = 1500 mm, Temp. short/long: 0/0 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 18
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads 3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 21.475 8.200 8.200 0.000
2 21.475 8.200 8.200 0.000 x
Tension
3 21.475 8.200 8.200 0.000
4 21.475 8.200 8.200 0.000
max. concrete compressive strain: - [‰]
max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 85.900 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN] 1 2

3 Tension load (EOTA TR 029, Section 5.2.2)


Load [kN] Capacity [kN] Utilisation bN [%] Status
Steel failure* 21.475 64.000 34 OK
Combined pullout-concrete cone failure** 85.900 256.241 34 OK
Concrete cone failure** 85.900 87.515 99 OK
Splitting failure** N/A N/A N/A N/A
* most unfavourable anchor **anchor group (anchors in tension)

3.1 Steel failure


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
96.000 1.500 64.000 21.475

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] 2
t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
300304 82944 24.00 288 144 270
2 0
hef,Helix [mm] yc t Rk,cr [N/mm ] k y g,Np y g,Np
96 1.000 22.00 2.300 1.000 1.000
ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np
0 1.000 0 1.000 1.000 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
106.161 384.362 1.500 256.241 85.900

3.3 Concrete cone failure


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm]
341056 104976 162 324
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.200 40.405 1.500 87.515 85.900

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 19
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:

4 Shear load (EOTA TR 029, Section 5.2.3)


Load [kN] Capacity [kN] Utilisation bV [%] Status
Steel failure (without lever arm)* 8.200 38.400 22 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout failure** 32.800 175.030 19 OK
Concrete edge failure in direction y+** 16.400 129.098 13 OK
* most unfavourable anchor **anchor group (relevant anchors)

4.1 Steel failure (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
48.000 1.250 38.400 8.200

4.2 Pryout failure (concrete cone relevant)


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] k-factor k1
341056 104976 162 324 2.000 7.200
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
40.405 1.500 175.030 32.800

4.3 Concrete edge failure in direction y+


hef [mm] dnom [mm] k1 a b
108 16.0 1.700 0.063 0.057
c1 [mm] Ac,V [mm2] A0c,V [mm2]
270 433350 328050
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V
1.000 1.000 2.500 0 1.000 1.000
V0Rk,c [kN] gM,c VRd,c [kN] VSd [kN]
58.637 1.500 129.098 16.400

5 Combined tension and shear loads (EOTA TR 029, Section 5.2.4)

bN bV a Utilisation bN,V [%] Status


0.982 0.214 1.000 100 OK
(bN + bV) / 1.2 ≤ 1.0

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 15.907 [kN] dN = 0.176 [mm]
VSk = 6.074 [kN] dV = 0.243 [mm]
dNV = 0.300 [mm]
Long term loading:
NSk = 15.907 [kN] dN = 0.615 [mm]
VSk = 6.074 [kN] dV = 0.364 [mm]
dNV = 0.715 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 20
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:

7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility! 
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 21
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:

8 Installation data
Baseplate, steel: - Anchor type and size: HIT-HY 200-A + HIT-Z M16
Profile: Advance UKC; 152 x 152 x 7 x 7 mm Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 12 mm Hole depth in the base material: 172 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 208 mm
Drilling method: Hammer drilled
Cleaning: No cleaning of the drilled hole is required

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • No accessory required • Dispenser including cassette and mixer
• Properly sized drill bit • Torque wrench
y

175 175

45
3 4

175
260

x
175

1 2
45

45 260 45

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -130 -130 - - 1230 530
2 130 -130 - - 1230 530
3 -130 130 - - 1490 270
4 130 130 - - 1490 270

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 22
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 24
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 25/05/2017

BEAM END CONNECTION DESIGN (BS5950) - RAKER_POST

BEAM TO COLUMN - END PLATE CONNECTION


TEDDS calculation version 2.0.16
Section Details
Column UC 152x152x23 Gradecolumn = "S275"
Beam UC 152x152x23 Gradebeam = "S275"
Endplate - 490 x 152 x 10 Gradeendplate = "S275"
Bolts M16 (Grade 8.8)

Connection Details
number of bolt rows nbolts = 2
Bolt pitch pbolts = 400 mm
Bolt gauge gbolts = 90 mm
End plate end distance (top & bottom) e1endplate = 45 mm
End plate edge distance e2endplate = (dendplate - gbolts) / 2 = 31 mm
End plate length lendplate = pbolts (nbolts-1)+2 e1endplate = 490 mm
Weld leg length sweld = 6 mm
Beam end reaction Q = 85.9 kN
Check 1 - Essential detailing requirements
End plate thickness tendplate = 10 mm PASS
Bolt gauge gbolts = 90 mm PASS
End plate Length lendplate = 490 mm
End plate length for torsional requirements : PASS
Check 2 - Shear capacity of bolt group connecting end plate to supporting column
Shear capacity of top pair of bolts
pbsendplate = 460 N/mm2
Psbolts1 = min(Psbolts, 0.5 e1endplate tendplate pbsendplate) = 58.9 kN
Shear capacity of other bolts
Psbolts = 58.9 kN
Shear capacity of bolt group - sum of bolt capacities
Psboltssum = 2 Psbolts1 + 2 (nbolts - 1) Psbolts = 235.5 kN
Shear on bolt group Q = 85.9 kN
Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 25
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 25/05/2017

Utilisation factor Ucheck2 = Q / Psboltssum = 0.365


Shear capacity of bolt group to column : PASS
Check 3 - Shear and bearing capacity of end plate
for shear

pyendplate = 275 N/mm2


e1aendplate = e1endplate = 45 mm
Avendplate = 0.9 (2 e1aendplate + (nbolts - 1) pbolts) tendplate = 4410 mm2
Avnetendplate = Avendplate - nbolts Dhbolts tendplate = 4050 mm2
Effective net area coefficient
Keendplate = 1.20
Plain shear capacity of end plate
PvPendplate = min(0.6 pyendplate Avendplate, 0.7 Keendplate pyendplate Avnetendplate) = 727.7 kN
Av1endplate = (e1aendplate + (nbolts - 1) pbolts) tendplate = 4450 mm2
Ateffendplate = (e2endplate - 0.5 Dhbolts) tendplate = 220 mm2
Block shear capacity of end plate
PvBendplate = 0.6 pyendplate Av1endplate + 0.6 Keendplate pyendplate Ateffendplate = 777.8 kN
Shear capacity of the end plate Pvendplate = min (PvPendplate, PvBendplate) = 727.7 kN
Shear force on the end plate Q / 2 = 43.0 kN
Utilisation factor Ucheck3shear = Q / (2 Pvendplate) = 0.059
Shear capacity of end plate : PASS
for bearing
eendplate = e1endplate = 45 mm
bearing strength of the end plate
pbsendplate = 460 N/mm2
For top bolt,
bearing capacity of the end plate per bolt
Pbsendplate1 = min(dbolts tendplate pbsendplate, 0.5 eendplate tendplate pbsendplate) = 73.6 kN
For other bolts,
bearing capacity of the end plate per bolt
Pbsendplate = dbolts tendplate pbsendplate = 73.6 kN
Capacity of bolt group
Pbsendplatesum = 2 Pbsendplate1 + 2 (nbolts - 1) Pbsendplate = 294.4 kN
Bearing force on bolt group Q = 85.9 kN
Utilisation factor Ucheck3bearing = Q / Pbsendplatesum = 0.292
Bearing capacity of endplate : PASS
Check 4 - shear capacity of the beam web at the endplate

pybeam = 275 N/mm2


Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 26
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 25/05/2017

Weld to full internal profile of beam


Avbeam = Dbeam tbeam = 884 mm2
Shear capacity of beam web
Pvbeam = 0.6 pybeam Avbeam = 145.8 kN
Shear force on beam Q = 85.9 kN
Utilisation factor Ucheck4shear = Q / Pvbeam = 0.589
Shear capacity of beam web : PASS
Check 5 - capacity of the fillet welds connecting the end plate to the beam web
Effective throat size of weld aweld = sweld 0.7 = 4.2 mm

Effective length of weld lweld = 4 (Bbeam/ 2 - tbeam/ 2 - rbeam- sweld) + 2 (dbeam + 2 rbeam) = 516.0 mm
Design strength of weld pweld = 220 N/mm2
Capacity of fillet welds Pweld = pweld lweld aweld = 476.8 kN
Utilisation factor Ucheck5weld = Q / Pweld = 0.180
Capacity of fillet weld : PASS
Check 6 - Local shear and bearing capacity of column flange
for shear
etbeama = etbeam = -50 mm
Avcolumn = (pbolts + (nbolts - 1) pbolts + etbeama) Tcolumn = 5100 mm2
Avnetcolumn = Avcolumn - nbolts Dhbolts Tcolumn = 4855 mm2

pycolumn = 275 N/mm2


Effective net area coefficient
Kecolumn = 1.20
Pvcolumn = min(0.6 pycolumn Avcolumn, 0.7 Kecolumn pycolumn Avnetcolumn) = 841.5 kN
Shear load on column Q / 2 = 43.0 kN
Utilisation factor Ucheck6shear = Q / (2 Pvcolumn) = 0.051
Local shear capacity of column flange: PASS
for bearing
pbscolumn = 460 N/mm2
Pbscolumn = dbolts Tcolumn pbscolumn = 50.0 kN
Q / (2 nbolts) = 21.5 kN
Utilisation factor Ucheck6bearing = Q / (2 nbolts Pbscolumn) = 0.429
Local bearing capacity of column flange : PASS

SUMMARY OF RESULTS
Check 2 - Shear capacity of bolt group connecting end plate to supporting column
Shear utilisation factor Ucheck2 = 0.365 PASS
Check 3 - Capacity of end plate
Shear utilisation factor Ucheck3shear = 0.059 PASS
Bearing utilisation factor Ucheck3bearing = 0.292 PASS
Check 4 - Shear capacity of the beam web at the endplate
Shear utilisation factor Ucheck4shear = 0.589 PASS
Check 5 - Capacity of the fillet welds connecting the end plate to the beam web
Project Job Ref.

23 Denewood – Façade Retention 17-142-01


Section Sheet no./rev.
Contractors Deign Servces
F3 Architects 27
6 Millers House Roydon Rd
Stanstead SG12 8HN Calc. by Date Chk'd by Date App'd by Date

01920 877077 RJ 25/05/2017

Shear utilisation factor Ucheck5weld = 0.180 PASS


Check 6 - Local shear and bearing capacity of column flange
Shear utilisation factor Ucheck6shear = 0.051 PASS
Bearing utilisation factor Ucheck6bearing = 0.429 PASS

Hence, use
4 No. M16 gr. 8.8 bolts @ 90 & 400 c/c with 150 x 550 x 10 end plate