4.2.

12 ISA - Gigabit Ethernet access Card


• Acronym and code: GETH-AG (3AL 80411 AA--)
• Slot position: 2 to 9 - 13 to 20
• Relevant port cards:
– ETH-MB see 4.1.28 on page 427 and Table 16. on page 77.
– ISA ES16 see 4.1.27 on page 421 and Table 18. on page 79.

Refer to:
– Block diagram: see Figure 297. on page 478
– Front view: see Figure 298. on page 479

The GETH-AG access card is placed in the access area and can be equipped with up to 4 “Optical
Transceiver modules at 1.25 Gb/s" providing Gigabit Ethernet Interfaces to allows LAN to LAN
connection. For the description of the optical module refer to paragraph 4.3.6 "SFP optical modules" (p.
532).
On the GETH-AG access card only the physical interface and some control functions are implemented,
so it must be used in conjunction with the ETHERNET or GIGABIT ETHERNET port where the signal is
processed in order to be transported in a SDH VCx. Refer to paragraph 3.8.5.2 on page 187 for details
on ethernet architecture in 1660SM.

Note: Not used if the “Gigabit Ethernet Access” is used in conjunction with the “Ethernet Port” (ETH-
MB.
INPUT side
The four Gigabit Ethernet flows coming from the “Optical Transceiver “ (DATA#1...DATA#4) are sent to
a block that performs the following functionality according to IEEE 802.3:
– Physical Coding Sublayer (PCS);allows to couple the Gigabit Media Independent Interface (GMII)
and the Physical Media Attachment (PMA).
The functions performed are:
• Serializer/de-serializer
• 8B/10B coding; 8 data bits are coded in a 10 data bits
– Auto-negotiation; negotiation of common data service functions with the device on the other end of
the link.
– Gigabit Media Independent Interface (GMII)
Subsequently the four 1.25 Gb/s Ethernet flows are sent towards the relevant “Ethernet port" or “Gigabit
Ethernet port" where the signals will be processed and mapped onto SDH-VC
A VCX0 is present on the board to deliver a 125 MHz clock.
OUTPUT side
The complementary operation described in the “Input side" are performed.

Control section
The RIBUS I/F block is present to read/write inventory data as code, serial number, construction data
implemented on the Remote Inventory and also send programming info to the “Alarms & Remote
Inventory Management" block.
On the front cover plate a red/green led is available giving fail alarm indication for the access card.
The presence of the Optical Transceiver modules is detected by the RIBUS I/F block by means of the
SI1...SI4 signals.

Alarms & Remote inventory Management


This block manage the alarms and commands receive/sent by/to the Optical Transceiver modules (LOS,
LASER FAIL, LASER SHUTDOWN). Also the Optical Transceiver modules Remote inventory data are
read through the RI1.....RI4 signals (for example the laser type). Further all this data are sent via ISFB
bus to the relevant port card and than to the Shelf Controller on the MATRIX card where are processed.

Technical Handbook Alcatel-Lucent 1660SM Rel. 5.5


Units Description 8DG15642AAAA Edition 07 477/746
The Alarms & Remote Inventory Management block is configurated by the RIBUS I/F; an external
configuration interface is also available on the board, but the use is for Alcatel-Lucent personnel only.

Figure 297. Gigabit Ethernet Access card -Block Diagram

+3.3 Vdc 125 MHz


125 MHz
SI1 OSC.
INPUT OPTICAL RI1
MODULE
LOS *1
Line #1 1000BASE-SX LASER FAIL
LASER SD Reset
1000BASE-LX
OUTPUT 1000BASE-ZX

ETHERNET PORT 10/100 Mb/s

GIGABIT ETHERNET PORT


DATA #1 #1
PCS sublayer

4X 1.2 Gbit/s to/from


( Serializer/Deserializer #2
8B/10B Coding/Decoding)

or
#3
+3.3 Vdc GMI Interface
SI2 Autonegotiation #4
INPUT OPTICAL RI2
MODULE
LOS *2
Line #2 LASER FAIL
1000BASE-SX 3.3 Vdc
LASER SD
1000BASE-LX
2.5 Vdc DC/DC

CONGI
FROM
OUTPUT 1000BASE-ZX DATA #2 Converters 48/60 V
1,8Vdc

Internal use only


+3.3 Vdc
SERIAL EXT.
OPTICAL SI3 CONFIGURAT. CONF.
INPUT MODULE RI3 PROM INT:

1000BASE-SX
CONFIGURATION
Line #3 LOS
*3
1000BASE-LX LASER FAIL
1000BASE-ZX LASER SD
OUTPUT
DATA #3
(*)

ETHERNET PORT 10/100 Mb/s

GIGABIT ETHERNET PORT


*1
+3.3 Vdc *2
SI4 *3 Alarms & ISFB
INPUT to/from
OPTICAL RI4 Remote Inventory
or
MODULE *4
Line #4 1000BASE-SX LOS RI1 Management
*4
LASER FAIL RI2
1000BASE-LX LASER SD RI3
OUTPUT 1000BASE-ZX RI4
DATA #4
CONFIGURATION

(*)
RESET
SI1
SI2

SI3
SI4

CMISS

TO/FROM
REMOTE MATRIXE
INVENTORY RIBUS RIBUS
FAIL I/F

+3.3 Vdc (Vs) F


+3.3 Vdc (Vs) FROM CONGI

ISA- GIGABIT ETHERNET ACCESS

Alcatel-Lucent 1660SM Rel. 5.5 Technical Handbook


478/746 8DG15642AAAA Edition 07 Units Description
Figure 298. ISA - Gigabit Ethernet access card - Front view
Acronym: GETH-AG

LEGENDA:

– (1) to (4) Gigabit Ethernet channels

Note: The cavities must be equipped with Eth-


ernet Optical Modules (refer to 4.3.6 on
page 532). Only two upper cavities can
be equipped when GETH-AG is used in
conjunction with ETH-MB unit.

OUTPUT

(1)
INPUT

(2)

– (5) Bicolor LED:


(3) • Red LED = Local unit alarm (INT)
• Green LED = In-Service unit

(4)

(5)

Technical Handbook Alcatel-Lucent 1660SM Rel. 5.5


Units Description 8DG15642AAAA Edition 07 479/746