Refer to:
– Block diagram: see Figure 297. on page 478
– Front view: see Figure 298. on page 479
The GETH-AG access card is placed in the access area and can be equipped with up to 4 “Optical
Transceiver modules at 1.25 Gb/s" providing Gigabit Ethernet Interfaces to allows LAN to LAN
connection. For the description of the optical module refer to paragraph 4.3.6 "SFP optical modules" (p.
532).
On the GETH-AG access card only the physical interface and some control functions are implemented,
so it must be used in conjunction with the ETHERNET or GIGABIT ETHERNET port where the signal is
processed in order to be transported in a SDH VCx. Refer to paragraph 3.8.5.2 on page 187 for details
on ethernet architecture in 1660SM.
Note: Not used if the “Gigabit Ethernet Access” is used in conjunction with the “Ethernet Port” (ETH-
MB.
INPUT side
The four Gigabit Ethernet flows coming from the “Optical Transceiver “ (DATA#1...DATA#4) are sent to
a block that performs the following functionality according to IEEE 802.3:
– Physical Coding Sublayer (PCS);allows to couple the Gigabit Media Independent Interface (GMII)
and the Physical Media Attachment (PMA).
The functions performed are:
• Serializer/de-serializer
• 8B/10B coding; 8 data bits are coded in a 10 data bits
– Auto-negotiation; negotiation of common data service functions with the device on the other end of
the link.
– Gigabit Media Independent Interface (GMII)
Subsequently the four 1.25 Gb/s Ethernet flows are sent towards the relevant “Ethernet port" or “Gigabit
Ethernet port" where the signals will be processed and mapped onto SDH-VC
A VCX0 is present on the board to deliver a 125 MHz clock.
OUTPUT side
The complementary operation described in the “Input side" are performed.
Control section
The RIBUS I/F block is present to read/write inventory data as code, serial number, construction data
implemented on the Remote Inventory and also send programming info to the “Alarms & Remote
Inventory Management" block.
On the front cover plate a red/green led is available giving fail alarm indication for the access card.
The presence of the Optical Transceiver modules is detected by the RIBUS I/F block by means of the
SI1...SI4 signals.
or
#3
+3.3 Vdc GMI Interface
SI2 Autonegotiation #4
INPUT OPTICAL RI2
MODULE
LOS *2
Line #2 LASER FAIL
1000BASE-SX 3.3 Vdc
LASER SD
1000BASE-LX
2.5 Vdc DC/DC
CONGI
FROM
OUTPUT 1000BASE-ZX DATA #2 Converters 48/60 V
1,8Vdc
1000BASE-SX
CONFIGURATION
Line #3 LOS
*3
1000BASE-LX LASER FAIL
1000BASE-ZX LASER SD
OUTPUT
DATA #3
(*)
(*)
RESET
SI1
SI2
SI3
SI4
CMISS
TO/FROM
REMOTE MATRIXE
INVENTORY RIBUS RIBUS
FAIL I/F
LEGENDA:
OUTPUT
(1)
INPUT
(2)
(4)
(5)