Você está na página 1de 2

Diagnostic Audiometer AD226

- Efficient Hearing Examinations

Audiometry
Features Applications
precision band noise or white noise as stimulus as well
• 125Hz - 8000Hz The high quality of the AD226 makes it as masking with narrow band noise, is also
• -10dB to 120dBHL output particularly well suited for any stationary or incorporated. Upon test completion the test
portable application where diagnostic testing results can be recalled from memory of the
• Air and Bone Conduction of air and bone conduction thresholds is AD226 or transferred to a PC for database
• WN and NB masking performed. The time saving automatic test storage or printing.
• 5dB and 1dB attenuators function combined with the computer
interface makes the AD226 ideal for
ABLB / SISI / Stenger / Langenbeck
• Insert Phones (optional) As well as the pre-programmed ABLB and
• Pure, Warble and Pulsed tones modern healthcare environments. The Talk
SISI tests, the AD226 can perform the
Forward function makes it easy to work with
• Automatic Threshold test Stenger test for evaluating malingering.
the AD226, especially with sound cabin
• SISI and Bekesy tests The Langenbeck Tone in Noise test is also
installations. Full NOAH compatibility
included.
• Stenger and ABLB tests completes the picture.
• Tone in Noise test (Langenbeck) Automatic Testing Insert Phones
• Talk Forward EarTone 5A Insert Phones (optional) may
The AD226 incorporates a facility for
be supplied in addition to the standard
• USB/RS232 connection for PC performing threshold determination
TDH39 audiometric headset. These insert
• PC on-line monitoring available automatically. The test procedure is based on
phones provide very low cross hearing and
either the Hughson-Westlake method (up
• NOAH compatible effectively reduce the need for masking.
5dB, down 10dB) or the standard OSHA
• Printing options via PC Ambient noise is also attenuated.
procedure. Desired test frequencies may be
• Carrying case (optional) selected freely by the user. The Bekesy test,
featuring pure tone, pulsed tone, narrow

leading diagnostic solutions


Interconnections
AD226
Software for PC:
UPS400 Mains PrintView
Supply100-240V OtoAccess™ Database
NOAH Modules
IFC69 - serial / UCA40 USB

General Technical Specifications


Standards: Input: Tone, Warble Tone +5%, 5Hz (true sine Langenbeck (Tone in Noise).
Audiometer: EN 60645 -1, ANSI S3.6, Type 3 wave frequency modulation). Bekesy Test:
Safety: EN 60601-1, Class I, Type B. Masking stimulus: NB Noise / White Noise. Pure Tone or Narrow Band stimulation. Fixed
Outputs: Left, Right, Bone L+R, Insert Phones, frequency. Continuos and pulsed tone.
Medical CE-mark: Insert Masking. OSHA automatic pure tone test procedure.
Interacoustics A/S meets the requirements of the
Annex II of the Medical Device Directive 93/42/ Transducers: Display: Alpha-Numeric Display.
EEC. Approval of the quality system is made by TDH39 Audiometric Headset Patient Signal: Reed switch push button.
TÜV – identification no. 0123. EAR-Tone 5A Insert Phones (optional)
B71 Bone Conductor Examples of Compatible Windows® Software:
Audiometer Type: 3. Interacoustics OtoAccess™ database program and
Calibration: AC: ISO 389-1 (TDH39), ISO 389- Talk Forward: Built in talk forward microphone. diagnostic modules software.
2 (EARTone5A), BC: ISO 389-3. 0-110dB SPL continuously adjustable on PrintView for on-line PC monitoring and
Frequencies and Maximum Hearing Levels: operation panel. printing.
Tone Presentation: Manual or Reverse. NOAH hearing aid fitting software.
AC dBHL AC dBHL BC dBHL Single pulse.
Hz TDH39 EARTone5A B71 Multiple pulses 250-5000 msec. on/off. Construction: Plastic cabinet
125 90 95 Auto Threshold: Patient controlled Hughson Attenuator controls:
250 110 100 45 Westlake procedure according to ISO 8253 or Rotary switches (Push buttons optional)
500 120 120 65 OSHA procedure according to NIOSH.
750 120 120 70 Frequency Selection: 125Hz, 250Hz, 500 Hz, Power Supply: External UPS400 (included).
1000 120 120 70 750Hz, 1500Hz or 8kHz may freely be deselected 100 - 115 V or 230 V Please specify.
1500 120 120 70 if a quicker test routine is desired. Consumption: 40 VA
2000 120 120 75 Synchronous Masking: Locks channel 2
3000 120 120 80 attenuator to channel 1 attenuator. Dimensions (WxDxH): 30x23x9 cm/
4000 120 120 80

83000402 - 4 - 08/2007
Store Function: Internal memory for AC L/R and 12x9x4 inches.
6000 120 105 55 BC L/R. Weight: 1.3kg/2.9 lbs. (external power supply
8000 110 100 50 UPS400 + 0.8kg/1.8 lbs.)
Extended Range Function: If not selected, Tests:
the AC output will be limited to 20dB below SISI with auto score calculation. (5dB Air freight packing (WxDxH):
maximum output. included for familiarisation). 1 case: 73x36x17 cm /29x14x7 inches.
ABLB Gross weight: 5.2 kg/11.5 lbs.
Stenger (Binaural pure tone stimulation).

Included Parts: Optional Parts:


TDH39 Audiometric Headset 21925 Amplivox Audiocups, noise reducing
B71 Bone Conductor headset
APS3 Patient Response Button 50250 Peltor noise reducing headset (may be
UPS400 External Power Supply supplied at not extra cost) The lightweight carrying
200 AF12 Audiogram Charts EARTone5A Audiometric Insert Phones case ACC26 will hold the
3 Pens IFC69 (9 pins) serial computer cable AD226 as well as a noise
Dust Cover UCA40 USB computer cable
reducing headset and
Operation Manual CD Push buttons instead of rotary
audiogram charts etc.
Multilingual CE Instructions for Use ACC26 Carrying Case
OtoAccess™ Database and diagnostic modules
software

Interacoustics A/S Sales and Service in your area:


Phone: +45 6371 3555
Fax: +45 6371 3522
E-mail: info@interacoustics.com
Web: www.interacoustics.com
Mail: Interacoustics A/S,
DK-5610 Assens, Denmark

Você também pode gostar