TECHNICAL NEWS Date: 18 August 2009
SONY EMCS (Malaysia) Sdn. Bhd.
QA/CS Centre KL Tec
CS Engineering Dept.
Lot 4. Jalan P/1, Kawasan Perindustrian Bangi, Issued Checked Approved
43650 Bandar Baru Bangi, Selangor Darul Ehsan, Malaysia. 2009 2009
.08.1 .08.1
2009.0
QA/CS KL TVEG 8.19
8 8
Quality
QA/CS KL
CS
Engineering 12:3 Innovation 15:2 CS
08:17:
TVG-M09037
Engineering
Cause : Due to the usage of multi source panel, there is a big fluctuation on the ADC
Calibration result which current average data cannot be used.
Service Treatment :
To overcome this issue, technician needs to manually conduct the ADC Calibration process on
each customer set after change the panel or main board.
Note: After change the panel or main board, software update is required. Please refer to
Technical News TVG- M09030. After USB SW update only please follow the steps in next
page.
After panel and/or main board replacement is done & USB SW update is performed, please
perform the following steps.
Page 2
Step 1:
Perform “Factory Setting” and select “Shop Mode” from the initial setup menu.
Step 2:
Change to Component mode and turn off the OSD.
Step 3:
Enter the service mode.
Step 4:
Next, press “Previous Channel” on remote commander. Screen as below will appear:
Page 3
Step 5:
Then, press “8” + “0” + “7” on remote commander. Screen as below will appear:
Step 6:
By using DVD player, please input “color bar signal” through the component input.
Step 7:
Next, press “Item select- right key” on the remote commander as below.
The adjustment process will start automatically.
Step 9:
Then, press “8” + “1” + “5” on remote commander.
Please record down the number that appears on screen as shown below.
Step 11:
Change the “PC SACR” accordingly by using remote commander.
Page 6
Step 12:
Repeat step 9, 10 and 11 for SACG, SACB, SAGR, SAGG, and SAGB value.
Step 13:
Press “TV Standby” button on remote commander to save the data. Then turn on the TV &
perform “Factory Setting”.
Affected Models: