Table 1 Information about the UPBA0 and UPBA2 boards

Physical Logical Back Description Installed Software


Board Board Board

UPBA0 ENSFU USIA1 Lead in and process Operating system: Novell


signaling messages. SUSE Linux Enterprise
Server 10 SP3 for x86_32
Version software: ENS-FE
application software

UPBA2/UPBA6 USRSU USIA1  Implement the Operating system: Novell


subscriber data SUSE Linux Enterprise
query and Server 10 SP3 for x86_32
routing Version software: USCDB
functions. application software
 Store the
subscriber data
and implement
the functions
such as adding,
deleting,
updating, and
querying data
based on the
service
processing
requirements of
the DRU.

USDID USIA1  Implement the Operating system: Novell


subscriber data SUSE Linux Enterprise
query and Server 10 SP3 for x86_32
routing Version software: USCDB
functions. application software
 Store the
subscriber data
and implement
the functions
such as adding,
deleting,
updating, and
querying data
based on the
service
processing
requirements of
the DRU.
 Provide the
integrated data
services.
Table 1 Information about the UPBA0 and UPBA2 boards

Physical Logical Back Description Installed Software


Board Board Board

 Implement the
provisioning
gateway.

OMU USIA7 Implement the OM Operating system: Novell


subsystem SUSE Linux Enterprise
(embedded with the Server 10 SP3 for x86_32
software management Version software: OMU
center). application software

UPBA6 USPID3 USI2  Provides Operating system: Novell


integrated data SUSE Linux Enterprise
services. Server 10 SP3 for x86_64
 Functions as the Database: PT database
service Version software: USCDB
provisioning application software
gateway.
Board Configuration Rules

Rules for Configuring the Basic Subrack


The logical boards OMU, USRSU, USPID3, and ENSFU are installed in the basic subrack. The
OMU boards are installed in slots 0 and 2; the USRSU boards are installed in slots 4, 5, 8, and 9;
the USPID3 boards are installed in slots 10 and 12; the ENSFU boards are installed in slots 1, 3,
11, and 13. Figure 1 shows the board configuration of the basic subrack.
Figure 1 Board configuration of the basic subrack

Rules for Configuring the Logical Boards


Table 2 describes the rules for configuring the logical boards.
Table 2 Rules for configuring the logical boards

Logical Board Configuration Principle

OMU Each site is configured with two OMU boards.

ENSFU If the FE and BE are deployed in the same subrack, the ENSFU boards are
permanently installed in slots 1, 3, 11, and 13. If the FE and BE are
deployed in different subracks, the ENSFU boards are installed from the
left of the SWU boards to the right.

USRSU The USRSU boards are permanently installed in slots 4, 5, 8, and 9.

USPID3 Each site is configured with two USPID3 boards.

Rules for Configuring the SWU/SWI Boards


Table 3 describes the rules for configuring the SWU/SWI boards.

Table 3 Rules for configuring the SWU/SWI boards

Board Networking Type Integrated Deployment

SWU/SWI IP networking  Basic subrack: SWUA0/SWUB0 (front board) +


SWIA0 (back board)
 Expansion subrack: SWUA0/SWUB0 (front
board) + SWIA0 (back board)
Parent topic: Board
Figure 1 Cabinet configuration of the ENS

Configuration of Cabinets and Internal Components

Figure 1 provides the configuration of the cabinet and major internal components.
Table 1 Configuration of the cabinet and major internal components

Cabinet and Internal Component Quantity

Cabinet 1

PDB 1

OSTA 2.0 subrack 1

KVMS (Optional) 1

LAN switch 2
Configuration of OSTA 2.0 Boards

Table 2 lists the configuration of the OSTA 2.0 boards shown in Figure 1.

Table 2 Configuration of the OSTA 2.0 boards

Board Type Front Board or Back Board Quantity

OMU Front board 2

USRSU Front board 2

USPID3 Front board 2

SWUA0 Front board 2

ENSFU Front board 2

USI2 Back board 2

USIA7 Back board 2

USIA1 Back board 4

SWIA0 Back board 2


Parent topic: Hardware Description