Genelec 1030A
Monitoring Speaker
Genelec 1030A Monitoring Speaker

may cause acoustical cancellation problems


System Crossover
around the crossover frequency.
The bi-amplified GENELEC 1030A is a two The active crossover network consists of two Sufficient cooling for the amplifier must
way active monitoring speaker designed parallel bandpass filters. Acoustically, the be ensured if the speaker is installed in a
to produce high SPL output, low coloration filters are complementary and the slopes are restricted space such as a cabinet or inte-
and broad bandwidth in a small cabinet size. 24 - 32 dB/octave. The crossover frequency grated into a wall structure. The minimum
The 1030A is ideal for applications where is 3.5 kHz. The active crossover controls clearance for the amplifier is 10 centimeters
space is at premium such as Near Field (‘treble tilt’, ‘bass tilt’ and ‘bass roll-off’) allow (4") to any object. The space adjacent to the
monitoring, mobile vans, broadcast and TV this speaker to be exactly matched to any amplifier must either be ventilated or suf-
control rooms, surround sound systems and room environment. ficiently large to dissipate heat so that the
budget and home studios. Designed as an ambient temperature does not rise above 35
active speaker, the 1030A contains drivers, Amplifiers degrees Celsius (95°F).
power amplifiers, active crossover filters and The amplifier unit is mounted to the rear of Before connecting up, ensure that the
protection circuitry. The Directivity Control the speaker enclosure on quick release vibra- mains switch is off (see figure 4). Check
Waveguide™ (DCW™) technology used tion isolators, to ensure rattle free operation that the mains voltage selector is correctly
provides excellent frequency balance even and long term reliability. The bass and treble set (Models sold in Europe have a fixed 230
in difficult acoustic environments. amplifier produce respectively 80 W and V setting). Audio input is via a 10 kOhm bal-
50 W of short term power. The peak output anced XLR connector, but unbalanced leads
Drivers sound pressure level of the 1030A exceeds may be used as long as pin 3 is grounded
The low frequencies are reproduced by a 170 115 dB at 1 m. The unit incorporates special to pin 1 of the XLR (see figure 3). Once the
mm (6 1/2”) bass driver loaded in a 6.5 liters circuitry for driver overload protection. Vari- connection has been made, the speakers are
vented cabinet. The -3 dB point lies at 52 Hz able input sensitivity allows for accurate level ready to be switched on.
and the frequency response extends down to matching to console output section.
47 Hz (-6 dB). Setting the input sensitivity
The high frequency driver is a 19 mm Installation The input sensitivity of the speakers can be
(3/4”) metal dome. Uniform dispersion con- Each 1030A monitor is supplied with a matched to the output of the mixing console,
trol is achieved with the innovative DCW mains cable and an operating manual. or other source, by adjusting the input sensi-
Technology pioneered by Genelec, which After unpacking, place the speaker so that tivity control on the rear panel (see figure 4).
also provides perfect phase and delay uni- its acoustical axis (see figure 2) is aimed A small screwdriver is needed for the adjust-
formity at the crossover frequency. towards the listening position. Do not place ment. The manufacturer’s default setting for
Both drivers are magnetically shielded. the speaker in a horizontal position as this this control is -6 dBu (fully clockwise) which
Speaker Mounting Treble tilt Bass tilt Bass roll-off
Position
Flat anechoic response None None None
Free standing in a None -2 dB None
damped room
Free standing in a None -4 dB -2 dB
reverberant room
Near field or console None -4 dB -4 dB
bridge

Table 1. Suggested tone control settings in some typical situations

Cable

RCA Screen XLR


(Source) (Speaker)

Figure 1. Amplifier panel layout of the 1030A Figure 2. Location of the acoustic axis Figure 3. RCA to XLR cable

gives an SPL of 100 dB @1m with -6 dBu Console top mounting expose the unit to water or moisture. Do
input level. not place any objects filled with liquid,
If the 1030A’s are used for near field monitor- such as vases on the speaker or near it.
Setting tone controls ing, avoid mounting them on the meter bridge 4. Note that the amplifier is not
The response of the system may also have of the console. Instead position the speakers completely disconnected from the AC
to be adjusted to match the acoustic envi- slightly behind the console by using floor mains service unless the mains power
ronment. The adjustment is done by setting stands or wall mounts. This prevents the cord is removed from the amplifier or the
the three tone control switch groups ‘treble first reflections from the console surface from mains outlet.
tilt’, ‘bass tilt’ and ‘bass roll-off ’ on the rear coloring the sound.
panel of the amplifier. The factory settings WARNING!
for these controls are ‘All Off ’ to give a flat Maintenance This equipment is capable of producing
anechoic response. See Table 1 for sug- No user serviceable parts are to be found sound pressure levels in excess of 85 dB,
gested tone control settings. Figure 5 shows within the amplifier unit. Any maintenance which may cause permanent hearing
the effect of the controls on the anechoic or repair of the 1030A unit should only be damage.
response. Always start adjustment by setting undertaken by qualified service personnel.
all switches to ‘OFF’ position. Then set only Accessories
one switch to the ’ON’ position to select the Safety considerations Order code
response curve needed. If more than one Although the 1030A has been designed Protective grille 1030-409
switch is set to ‘ON’ (within one switch group) in accordance with international safety Wall mount 1030-404-V/H*
the attenuation value is not accurate. standards, to ensure safe operation and to Floor stand 1030-405-V/H*
maintain the instrument under safe operating
Vertical / horizontal mounting conditions, the following warnings and cau- *State the desired speaker orientation
The speakers are normally delivered set tions must be observed: V=vertical or H=horizontal when ordering
up for vertical mounting. Horizontal mount- 1. Servicing and adjustment must only these accessories.
ing should be avoided due to the increased be performed by qualified service
likelihood of early reflections that degrade personnel. The amplifier’s rear panel must Guarantee
the the direct sound. If horizontal mounting not be opened. This product is supplied with one year guar-
is needed the DCW plate may be rotated so 2. Do not use this product with an antee against manufacturing faults or defects
that the Genelec logo remains horizontal by unearthed mains cable as this may lead to that might alter the performance of the 1030A
removing the four corner screws of the DCW personal injury. unit. Refer to supplier for full sales and guar-
and carefully lifting and turning the DCW. 3. To prevent fire or electric shock, do not antee terms.
1030A Operating Manual

AUDIO PRECISION 1030anec LEVEL(dBr) vs FREQ(Hz) 14 JAN 94 12:34:40 AUDIO PRECISION 1030anec LEVEL(dBr) vs FREQ(Hz) 14 JAN 94 12:09:56

100 100

95 95
0
15 TREBLE TILT
90 90

BASS TILT
85 85

80 80
30
45
75 75

BASS ROLL-OFF
70 70

65 100 65

60 95 60

55 90 55

50

20 100 1k 10k 20k 20 100 1k 10k 20k

Figure 4. The upper curve group shows the horizontal directivity Figure 5. The curves show the effect of the bass tilt, treble tilt and
characteristics of the 1030A in vertical configuration measured at 1 m. bass roll-off controls on the free field response.
The lower curve is a 1/3 octave band power response, measured in an
IEC approved reverberation chamber.

SYSTEM SPECIFICATIONS CROSSOVER SECTION AMPLIFIER SECTION

Lower cut-off frequency, -3 dB: < 52 Hz Input connector XLR female: Bass amplifier short term output power with a
Upper cut-off frequency, -3 dB: > 20 kHz pin 1 gnd 4 Ohm load:
pin 2 + 80 W
Free field frequency response of system: pin 3 -
55 Hz - 18 kHz (± 2.5 dB) Treble amplifier short term output power with an
Input impedance: 10 kOhm balanced 8 Ohm load:
Maximum short term sine wave acoustic output on 50 W
axis in half space, averaged from 100 Hz to 3 kHz: Input level for 100 dB SPL output @ 1m:
@ 1m > 105 dB SPL variable from +6 to -6 dBu Long term output power is limited by driver unit
@ 0.5m > 111 dB SPL protection circuitry.
Input level for maximum short term sine wave output
Maximum long term RMS acoustic output in same of 105 dB SPL @ 1m: Amplifier system distortion at
conditions with IEC weighted noise (limited by variable from +11 to -1 dBu nominal output:
driver unit protection circuit): THD < 0.08%
@ 1m > 99 dB SPL Subsonic filter below 50 Hz : 18 dB/octave SMPTE-IM < 0.08%
@ 0.5m > 105 dB SPL CCIF-IM < 0.08%
Ultrasonic filter above 25 kHz: 12 dB/octave DIM 100 < 0.08%
Maximum peak acoustic output per pair above
console top, @ 1 m from the engineer with music Crossover frequency, Bass/Treble: 3.5 kHz Signal to Noise ratio, referred to full output:
material: > 115 dB Bass > 95 dB
Crossover acoustical slopes: Treble > 95 dB
Self generated noise level in free field @ 1m 24 - 32 dB/octave
on axis: < 10 dB (A-weighted) Mains voltage: 230, 100/200 or 115/230V
Treble tilt control operating range in 2 dB steps: according to region
Harmonic distortion at 90 dB SPL @ 1m on axis: from +2 to -4 dB & MUTE
Freq: 60...150 Hz < 3%
Voltage operating range: ±10%
> 150 Hz < 0.5% Bass roll-off control operating range in 2 dB steps:
from 0 to -8 dB @ 50 Hz
Power consumption:
Drivers: Bass 170 mm (6 1/2") cone
Idle 10 VA
Treble 19 mm (3/4") metal dome Bass tilt control operating range in 2 dB steps:
Full output 100 VA
Both drivers are magnetically shielded. from 0 to -6 dB @ 100 Hz
& MUTE
Weight: 7,6 kg (17 lb)
Dimensions: The 'CAL' position is with all tone controls set to 'off'
Height 312 mm (12 1/4") and the input sensitivity control to maximum (fully
Width 200 mm ( 7 7/8") clockwise).
Depth 240 mm (9 7/16")

Genelec Document D1030AR001 Copyright Genelec Oy 3.2003. All data subject to change without prior notice www.genelec.com
International enquiries: In the U.S. please contact: In China please contact:
Genelec, Olvitie 5 Genelec, Inc., 7 Tech Circle Genelec China Representative Office
FIN-74100, Iisalmi, Finland Natick, MA 01760, USA Soho New Town, 88 Jianguo Road
Phone +358 17 83881 Phone +1 508 652 0900 D-1504, Chaoyang District
Fax +358 17 812 267 Fax +1 508 652 0909 Beijing 100022, China
Email genelec@genelec.com Email genelec.usa@genelec.com Phone +86 10 8580 2180
Fax +86 10 8580 2181

Você também pode gostar