Você está na página 1de 4

Individual footing’s bearing capacity check of proposed two storied RCC

building of Arien Knit Composite Ltd.


Footing points of proposed footings (Grid K, L and M) of two storied building.
Footings of grid K will be combined with Grid J footings (one storied steel shed).

Soil bearing capacity consideration


From soil test report of Bore hole-6 and Bore hole-11 where the proposed building will
be constructed at 5 to 10 ft depth average allowable bearing capacity for square
footing=0.545 tsf (FOS=3.0)=1.318 ksf (FOS=2.5).

After Soil improvement / compaction of below each footing , allowable bearing capacity
will be =1.318 *1.4=1.83 ksf (FOS=2.5).
Proposed footings adequacy check. (Loads are taken from Finite Model considering all
possible loads)
Proposed Footing
WSD Required
SL
load footing Length width Area Comment
No
(kip) size (sft) (ft) (ft) (sft)

1 150 82 9.50 9.50 90.25 OK


2 125 68 9.50 9.50 90.25 OK
3 143 78 9.50 9.50 90.25 OK
4 147 80 9.50 9.50 90.25 OK
5 162 89 9.50 9.50 90.25 OK
6 109 60 8.00 8.00 64 OK
7 99 54 8.00 8.00 64 OK
8 71 39 6.50 6.50 42.25 OK
9 58 32 6.50 6.50 42.25 OK
10 69 38 6.50 6.50 42.25 OK
11 69 38 6.50 6.50 42.25 OK
12 73 40 6.50 6.50 42.25 OK
13 48 26 5.75 5.75 33.06 OK
14 42 23 5.75 5.75 33.06 OK
15 146 80 11.00 7.50 82.5 OK
16 127 69 11.00 7.50 82.5 OK
17 139 76 11.00 7.50 82.5 OK
18 140 77 11.00 7.50 82.5 OK
19 150 82 11.00 7.50 82.5 OK
20 96 52 9.84 5.90 58.06 OK
21 92 50 9.84 5.90 58.06 OK

This short report consists of only bearing capacity of soil to bear the service load of
proposed two storied building. Proposed foundations’ thickness and reinforcement will
be finalized later.